Tender For Electrification Of Polling Stations Within The Jurisdiction Of Electric Division Iv Khanyar For Upcoming Parliamentary Election 2024, Ganderbal-Jammu And Kashmir

Power Development Department has published Tender For Electrification Of Polling Stations Within The Jurisdiction Of Electric Division Iv Khanyar For Upcoming Parliamentary Election 2024. Submission Date for this Tender is 20-04-2024. Electrification Work Tenders in Ganderbal Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43101718
Corrigendum : Tender For Electrification Of Polling Stations Within The Jurisdiction Of Electric Division Iv Khanyar For Upcoming Parliamentary Election 2024
Open Tender
Indian
Jammu And Kashmir
Ganderbal
20-04-2024

Tender Details

Tender For Electrification Of Polling Stations Within The Jurisdiction Of Electric Division Iv Khanyar For Upcoming Parliamentary Election 2024

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Apr-2024 1ST EXTENSION Date 20-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 10000.0 /-
Tender Value
INR 5 Lakhs /-

BOQ Items

Name of Work: Electrification of polling stations within the jurisdiction of Electric Division IV Khanyar for upcoming parliamentary election 2024
Sl. No. Item Description
1Providing & fixing of fresh lighting point (5-6 amp) exposed,using double locked PVCchannel 25x2 mmthick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 2x1.5 mm sq. pvc insulated copper wire (P+N) complete with P/F of switch 5/6 amps F/Tto be fitted on Gang Box, rowel plugs & screws etc. complete Point.
2Wiring for circuit/ submain wiring a with the following sizes of FRLS PVC insulated copper conductor, single core cable 2 x 1.5 sq. mm inSurfacethrough PVC channel ( Excluding the cost of channel)
3Wiring for heating pointwith the following sizes of FRLS PVC insulated copper conductor, single core cable 2 x 2.5 sq. mm inSurface/recessedpvc conduit as required.
4Supplying and Fixing 25 mm Double Locked PVC Channel 2 mm thick
5Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required 3 pin 5/6 A socket outlet
6Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required 15 A switch socket combine with box type
7Supplying and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breakerSingle pole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breakerdoublepole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10Supply and fixing of accessories LED Lamp 9/10 watt
11Supply and fixing of accessories Pendant Holder
12Providing and fixing 32A rating of Two pole side operated manual Changeover Switch in cubicle panel, making connections, etc. as required..
13Supply and laying of following size of 2-core Aluminium Cable unarmoured PVCsheathed / XLPE power cable 10 mmsq of 1.1 KV grade
14Supply and laying of following size of 2-core Aluminium Cable unarmoured PVCsheathed / XLPE power cable 16 mmsq of 1.1 KV grade
15Supplying and making end termination with and aluminium lugs for size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable 10 mmsq of 1.1 KV grade as required.
16Supplying and making end termination with and aluminium lugs for size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable .16 mmsq of 1.1 KV grade as required
17Providing, installation, testing and commissioning of LED Street lightluminaire along with holding arm with clamps and nuts and bolts as per following specification:- 1. Input voltage : 150 V to 270 V 2. LDE lamp efficiency : Min 95 to 110 lumens/watt3. Power factor : >0.904. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture
18P/F of MCB boxes (pvc) with strip    2 way
19Hire chages for 2.8 KVA Genset including carriage/transportation charges
20Providing of fuel of Genset Petrol