}

Tender For Repair And Renovation Of 2 Nos E Type Quarters At Chc Gurandi In The District Of Gajapati (Civil, Electrical Installation And Ph)., paralakhemundi-Odisha

Road And Building Department-RBD has published Tender For Repair And Renovation Of 2 Nos E Type Quarters At Chc Gurandi In The District Of Gajapati (Civil, Electrical Installation And Ph).. Submission Date for this Tender is 10-06-2024. Electrical Maintenance Tenders in paralakhemundi Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

43101600
Tender For Repair And Renovation Of 2 Nos E Type Quarters At Chc Gurandi In The District Of Gajapati (Civil, Electrical Installation And Ph).
National Competitive Bid
Indian
Odisha
paralakhemundi
10-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair And Renovation Of 2 Nos E Type Quarters At Chc Gurandi In The District Of Gajapati ( Civil, Electrical Installation And Ph ) .

Key Value

Document Fees
INR 6000 /-
EMD
INR 12500.0 /-
Tender Value
INR 12.40 Lakhs /-

Attachment

FileName File Description File Size
8a6f50cc-fa8c-4919-830f-d9ba3ec9ca84.html Tender Notice 0 KB
BOQ_500867.xls Tender Document 0 KB
DTCN9.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Tendernotice_2.pdf Tender Document 0 KB
Tendernotice_3.pdf Tender Document 0 KB
Tendernotice_4.pdf Tender Document 0 KB
Tendernotice_5.pdf Tender Document 0 KB
Tendernotice_6.pdf Tender Document 0 KB
Tendernotice_7.pdf Tender Document 0 KB

BOQ Items

Name of Work:Repair and renovation of 2 Nos E type Quarters at CHC Gurandi in the District of Gajapati(Civil, E.I & PH).
Sl. No. Item Description
12 Nos E type Quarter Dismantling 2.50 cm thick grading concrete from roof slabincluding cleaning the roof surface and lowering andremoving the debris with 50.00m lead including cost ofall and required to complete the work in all respect as per drawing and technical specification anddirection of Engineer-in-Charge.
2Providing 4.00 cm thick grading concrete(1:2:4) using 12 mm and down grade size HG Chips on new works including all cost of all and complete finished and required to complete the work in all respect as per drawing and technical specification anddirection of Engineer-in-Charge.
3Removing old cement/lime plasterfrom walls including racking out joints 12mm deep and removing the debris with in 50m leadincluding cost of all labour, Labour CESS and T&P. etc required to complete the work in all respect, as per direction of Engineer-in-charge.
4Providing 6mm. thick cement plaster in cement mortar (1:4)to RCC surfaces finished smooth including closed deep chipping and slurry treatment using good quality screened and washed river sand, including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, labour CESS,T&P, and scaffolding as requiredto completethe workin all respectas per the Direction of the Engineer-in-charge .
5Providing 12 mm thick cement plaster with cement mortar (1:6) with screened and washed sharp river sand for mortar and finished smooth to the rough surface of walls after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, Labour CESS,T&P, and scaffolding as requiredto completethe workin all respectas per the Direction of the Engineer-in-charge .
6Providing 16 mm thick cement plaster with cement mortar (1:6) with screened and washed sharp river sand for mortar and finished smooth to the rough surface of walls after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, Labour CESS,T&P, and scaffolding as requiredto completethe workin all respectas per the Direction of the Engineer-in-charge .
7Supplying, fitting & fixing of MS Window grills, grill gates and Doors made of ISI marked MS angle, M.S Flat or M.S square bars (10mm) and all fittings and fixtures of approved design and specification including cost, conveyance, fabrication of all materials, cost of all labour, labour CESS and T&P. etc. required to complete the work in all respect as per direction of Engineer-in-Charge.
8Dismantling and removing old tile flooring including removing the base course including stacking the usuful materials for re-use and removing the debris with 50.00m lead including cost of all and complete finished in all respect .etc. required to complete the work in all respect as per direction of Engineer-in-Charge.
9Supplying, fitting and fixing Colour vitrified tile 60x60cm8 to 10 mm thick in floorsof approved makeconfirming to IS : 13755 with application oSupplying, fitting and fixing vitrified tile 60x60cm colour printed 8 to 10 mm thick in floorsof approved makeconfirming to IS : 13755 over 20 mm thick CM 1:4and filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work.
10Supplying, fitting and fixing Colour vitrified tile 60x60cm8 to 10 mm thick in Dados of approved makeconfirming to IS : 13755 with application oSupplying, fitting and fixing vitrified tile 60x60cm colour printed 8 to 10 mm thick in floorsof approved makeconfirming to IS : 13755over 12 mm thick CM 1:3 and filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work.
11Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
12Wall painting 2coats with weather coat of approved shade on outer wall surface over a coat of cement primerto give an even shade including cost of brushes and putty including cost of paint scrapping, cleaning rubbing, scaffolding including all costs of labour etc. complete as per direction of E.I.C.
13Painting two coat with Plastic Emulsion Paint over a coat of primer to make in even finished surfaces in all floors and heights to wall surface o approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.
14Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge)..
15Supplying fitting and fixing Fibre Reinforced Polymer FRP composite doorFrame with hinge as per approved section with glass fibre reinforced plastic moulded skins and a special sandwiched core, so as to impart monolithic composite structure as per approved technology (DST) to satisfy IS: 14856 door testing performance criteria including all complete, make duly approved by Engineer-in-charge)..
16Supplying fitting and fixing Fibre Reinforced Polymer FRP composite door shutteras per approved section with glass fibre reinforced plastic moulded skins and a special sandwiched core, so as to impart monolithic composite structure as per approved technology (DST) to satisfy IS: 14856 door testing performance criteria including all complete, make duly approved by Engineer-in-charge.
17Supplying, diluting & preparing chemical emulsion like imidaclosed 30.5% SC or other chemicals approved by central insecticides Board or as directed by manufacture and spraying the mixture uniformly by sprayer as Pre- Constructional Anti Termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall treanches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding of pipes and conduits etc. at the rate of 7.5liters per sqm on vertical surface and 5.0liters per sqm on horizontal surface, 50% of the emulsion to be filled in the holes made in treanches at 150mm centre to centre (or as directed directed by the manufacture) including the cost of all material, cost of all labour, conveyance, loading, unloading, T&P, etc all complete as per the direction of Engineer-in-charge. (Approved rate for MPH building Sl no-1)
181 No Medical Officer Qtr. Dismantling 2.50 cm thick grading concrete from roof slabincluding cleaning the roof surface and lowering andremoving the debris with 50.00m lead including cost ofall and required to complete the work in all respect as per drawing and technical specification anddirection of Engineer-in-Charge.
19Providing and laying cement concrete (1:2:4)using 12mm size black hard granite crusher brokenchips and screened and washed sharp river sand of approved quality from approved quarryas per approved design including hoisting, lowering, laying and compacting to proper thickness, watering and curing for the required period, finished smooth , providing grooves or beads where necessaryincluding cost, conveyance, royalty of all materials with labour, labour CESS , and T&P etc. required to complete the workin all respect including dewatering if required as per direction of the Engineer-in-Charge.
20Providing 4.00 cm thick grading concrete(1:2:4) using 12 mm and down grade size HG Chips on new works including all cost of all and complete finished and required to complete the work in all respect as per drawing and technical specification anddirection of Engineer-in-Charge.
21Removing old cement/lime plasterfrom walls including racking out joints 12mm deep and removing the debris with in 50m leadincluding cost of all labour, Labour CESS and T&P. etc required to complete the work in all respect, as per direction of Engineer-in-charge.
22Providing 6mm. thick cement plaster in cement mortar (1:4)to RCC surfaces finished smooth including closed deep chipping and slurry treatment using good quality screened and washed river sand, including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, labour CESS,T&P, and scaffolding as requiredto completethe workin all respectas per the Direction of the Engineer-in-charge .
23Providing 12 mm thick cement plaster with cement mortar (1:6) with screened and washed sharp river sand for mortar and finished smooth to the rough surface of walls after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, Labour CESS,T&P, and scaffolding as requiredto completethe workin all respectas per the Direction of the Engineer-in-charge .
24Providing 16 mm thick cement plaster with cement mortar (1:6) with screened and washed sharp river sand for mortar and finished smooth to the rough surface of walls after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials, cost of all labour, Labour CESS,T&P, and scaffolding as requiredto completethe workin all respectas per the Direction of the Engineer-in-charge .
25Supplying, fitting & fixing of MS Doors made of ISI marked MS angle, M.S Flat or M.S square bars (10mm) and all fittings and fixtures of approved design and specification including cost, conveyance, fabrication of all materials, cost of all labour, labour CESS and T&P. etc. required to complete the work in all respect as per direction of Engineer-in-Charge.
26Supplying, fitting & fixing of MS Window grills made of ISI marked MS angle, M.S Flat or M.S square bars (10mm) and all fittings and fixtures of approved design and specification including cost, conveyance, fabrication of all materials, cost of all labour, labour CESS and T&P. etc. required to complete the work in all respect as per direction of Engineer-in-Charge.
27Dismantling and removing old tile flooring including removing the base course including stacking the usuful materials for re-use and removing the debris with 50.00m lead including cost of all and complete finished in all respect as per direction of Engineer-in-Charge.
28Dismantling and removing old tiled cladding from walls including racking out the joints 12mm deep including stacking the usuful materials for reuse and removing the debris with 50.00m lead including cost of all and complete finished in all respect as per direction of Engineer-in-Charge
29Supplying, fitting and fixing Colour vitrified tile 60x60cm8 to 10 mm thick in floorsof approved makeconfirming to IS : 13755 with application oSupplying, fitting and fixing vitrified tile 60x60cm colour printed 8 to 10 mm thick in floorsof approved makeconfirming to IS : 13755 over 20 mm thick CM 1:4and filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work.
30Supplying, fitting and fixing Glazed vitrified tile 60x60cm8 to 10 mm thick in Dados of approved makeconfirming to IS : 13755 with application oSupplying, fitting and fixing vitrified tile 60x60cm colour printed 8 to 10 mm thick in floorsof approved makeconfirming to IS : 13755over 12 mm thick CM 1:3 and filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work.
31Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
32Wall painting 2coats with weather coat of approved shade on outer wall surface over a coat of cement primerto give an even shade including cost of brushes and putty including cost of paint scrapping, cleaning rubbing, scaffolding including all costs of labour etc. complete as per direction of E.I.C.
33Painting two coat with Plastic Emulsion Paint over a coat of primer to make in even finished surfaces in all floors and heights to wall surface o approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.
34Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge)..
35Providing and laying factory made 80mm thick cement concrete interlocking paver blocks of m-30 grade made by block making machine with strong vibratory compaction of approved size and shape laid over compacted bed of course sand layer including filling sand in the interstices / joints including cost of all materials , labour and T&P required for the work etc. complete in all respect s per direction of Engineer in charge..
36E.I. Work Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard) Group-A-L.P-30F.P6 C.B.P-
37Group-B L.P-38F.P-28 C.B.P-
38Group-C L.P-28F.P-20C.B.P-1
39Supply and fixing of 3 pin 6Amp plugwith 6Amp switch on existing board (Modulartype )
40Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
41Supply and fixing of Modularmetal box on surface or in recess with suitable size of Modular coverin front including providing and fixing of 6pin 6Amp& 16Amp socket outlet and16Amp Modular switches connection(make-Anchor/ Legrand /Roma)
42Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard) 1 X 1.5sqmm
432 X 2.5sq.mm +1 X 1.5sqmm
442 X 4sq.mm +1 X 1.5sqmm.
45Supply and fixing of following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic covr for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB / RCCB / Isolator) 12 WAY DOUBLE DOOR
46Supply and fixing of 5Amp to 32A rating 240V "B/C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S) Single pole (SP)
47Double pole (DP)
48Supply and fixing Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required Standard earthingas per Govt. spcn.
49Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required
50Supply and fixing of different type of fitting with lamp 20 watt LED T-5fitting( Make-Bajaj/ Philips /Crompton)
51S/F of 09Watt LED Square/Round surface mountfitting (Make-Havells/Philips/C&S/Crompton)
52Bulk head in die cast aluminium housing & frosted glass
53Supply and fixing of fan (make-Usha/Orient/V-Guard/Khaitan/Havells/Crompton/Almonard) 9" Metal exhaust fan
54S/F of 1200mm High speed Ceiling fan, Heavy Duty,durable, copper winding,Aluminium blade(ISI mark) Crompton /Khaitan /Orient /Polycab /Bajaj
55Supply and fixing of Modularfan regulator, cll bell push, TV Socket Outlet(Cona/ Anchor/ Usha/Bajaj) Electronics step type Regulator (Modular type)
56P.H. Work Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge. Ground Floor25mm dia PVC ASTM pipe (sch-80)
5732mm dia PVC ASTM pipe (sch-80)
58Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. 250mmthick wall Ground Floor
59Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. Ground Floor
60Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. (Fixtures make of Brass / G.M / C.P fittings are to be pre-approved by the E.I.C) 15mm dia CP Long body bib cock (Plaza/Aquatic/Amber)
6115mm dia CP angle stop cock(Plaza/Aquatic/Amber)
6215mm dia CP long neck pillar cock(Plaza/Aquatic/Amber)
63Two-way Bib cock(Plaza/Aquatic/Amber)
64Health Faucet(Plaza/Aquatic/Amber)
65Sink Cock (Plaza/Aquatic/Amber)
6615mm dia CP revolving shower with arm(Plaza deluxe make)
6725mm dia brass or gun metal fullway valve (Shakti Make)
6832mm dia brass or gun metal fullway valve (Shakti Make)
6915mm dia CP Extension Piece
7015mm dia CP Flange
71125mm dia. CP grating
72Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 1000Ltr Roto-moulded water storage tank (Syntax Make) on the roof of Ground Floor
73Supplying all materials, labour, T&P and fitting and fixing10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bendSlimline white(Hindware / Parryware Make)
74Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe (Ashirbad /Sentinity/Supreeme)
75110mm U-PVC door tee
76110mm U-PVC Plain tee
77110mm U-PVC door bend
78110mm U-PVC plain bend
79110mm dia U-PVC "P" trap
80110mm dia U-PVC Plain Shoe Bend
81110mm dia U-PVC offset with out ear
82110mm dia U-PVC cowl
83Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge.250mm to 375mmthick wall
84Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
85Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware / Nycer make)
86Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal(Parrywaremake)
87Supplying all materials, labour, T&P and fixing wash kitchen sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make)
88Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete withCP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail
89CP Towel ring
90Supplying all materials ,labour ,T&P andfixing CP Soap Holder complete with CP brass bracketsfixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge. CP soap holder
91Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm glass shelf with CP/NP guard rails
92Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Mirror(Bevellededge) 600mmx450mm
93Supplying fitting and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of MS tube of 19 gauge thickness and size of 19mmx19mm for stile & 15mmx15mm for top and bolt rails set with PVC door frame(Choukatha)of size 50mmx47mm is made out of 5cm thick sheet properly joined with solvent cement adhesive as per section view with MS square tube of 19mm of 19mm gauge to be inserted inside to give extra structural strength the price is inclusive of all cost of all materials labour,T&P etc.complete in all respect as per direction of the Engineer-in-charge.
94Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete
95Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
96Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
97Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. 1.40m dia x 2.00m deep soakway pit
98Supplying submerssible pump with sqirrel cage induction type submersible type submerssible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034 - 2002 with following specifications 1H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm
99DOL Control panel
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail