}

Bids Are Invited For Make Switchgear 1 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 9 0 0 2 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 0 0 0 3 L&T Make U, South Andamans-Andaman And Nicobar Islands

Airports Authority Of India has published Bids Are Invited For Make Switchgear 1 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 9 0 0 2 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 0 0 0 3 L&T Make U. Submission Date for this Tender is 24-04-2024. Fuses Tenders in South Andamans Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

43100638
Bids Are Invited For Make Switchgear 1 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 9 0 0 2 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 0 0 0 3 L&T Make U
Open Tender
Indian
Andaman And Nicobar Islands
South Andamans
24-04-2024

Tender Details

Bids Are Invited For Make Switchgear 1 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 9 0 0 2 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 0 0 0 3 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 20 N F D 1 2 4 1 0 4 L&T Make U-Power Omega Air Circut Breaker Having Catalogue Reference No. Uw 1 08 N F D 0 1 4 1 0 5 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 160A Cat Ref. No. Cm92109oon1og ( Type - Dn2-250D ) 6 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 25Ka, 63A Cat Ref. No. Cm91712oojoog ( Type - Dn0-100C ) 7 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 100A Cat Ref. No. Cm92108ool1og ( Type - Dn2-250D ) 8 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 400A Cat Ref. No. Cm98403ooroog ( Type - Dn3b-400D ) 9 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 25Ka, 40A Ref. No. Cm91712oogoog ( Type - Dn0-100C ) 10 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 25Ka, 100A Ref. No. Cm91712ookoog ( Type - Dn0-100C ) 11 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type 4 Pole, 25Ka, 40A Type - Dn0-100C Cat- Cm91712oofoog 12 L&T Make D Sine Mccb With Thermal -Magnetic Release Having Specification And Type 4 Pole, 50Ka, 200A Type- Dn2-250N Cat- Cm92106oon1og 13 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type 3 Pole, 25Ka, 63A Type - Dn0-100C Cat- Cm91612oohoog 14 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type 4 Pole, 36Ka, 250A Cat Ref. No. Cm92109oop1og Type - Dn2-250D 15 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 25Ka, 160A Cat. Ref. No. Cm90642oono Type - Dn1-250C 16 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 400A Cat. Ref. No. Cm98403ooroog Type - Dn3b-400D 17 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 400A Cat. Ref. No. Cm94105oor1og Type - Dn3-400D 18 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 320A Type - Dn3b-400D Cat- Cm98403ooqoog 19 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type 4 Pole, 36Ka, 200A Cat. Ref. No. Cm92109oop1og Type -Dn2-250D 20 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 36Ka, 160A Cat. Ref. No. Dz1f0160dxd1a Type - Dz1-160D 21 L&T Make D Sine Mccb With Thermal - Magnetic Release Having Specification And Type. 4 Pole, 50Ka, 125A ( Type - Dz1-160 N ) , Cat- Dz1f0125nxd1a 22 Rccb ( Residual Current Circut Breakers ) 2 Pole, 40A, Sensitivity - 100Ma, Ip 20, Cat. Ref No. Aurad204010 23 Rccb ( Residual Current Circut Breakers ) 2 Pole, 25A, Sensitivity - 100Ma, Ip 20, Cat. Ref. No. Aurad202510 24 Rccb ( Residual Current Circut Breakers ) 2 Pole, 63A, Sensitivity - 100Ma, Ip 20, Cat. Ref. No. Aurad206310 25 Rccb ( Residual Current Circut Breakers ) 4 Pole, 25A, Sensitivity - 100Ma, Ip 20, Cat. Ref. No. Aurad402510 26 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 1 Pole, 6A 27 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 2 Pole, 6A 28 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 1 Pole, 10A 29 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 2 Pole, 16A 30 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 4 Pole, 16A 31 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 -2 Pole, 20A 32 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 4 Pole, 20A 33 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 2 Pole, 32A 34 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 4 Pole, 32A 35 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 4 Pole, 40A 36 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 4 Pole, 63A 37 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 - 2 Pole, 25A 38 Mcb - B Curve, 15Ka, Conforms To Is / Iec 60898, Iec 60947 -1 Pole, 20A 39 Mcb - C Curve, 10Ka, Conforms To Is / Iec 60898, Iec 60947 - 1 Pole, 2A 40 Mcb - C Curve, 10Ka, Conforms To Is / Iec 60898, Iec 60947 - 2 Pole, 2A 41 Mcb - C Curve, 10Ka, Conforms To Is / Iec 60898, Iec 60947 - 3 Pole, 2A 42 Spds ( Surge Protection Devices ) , Conforms To Iec 61643-11, Type 2 40Ka - Configuration 3P+N, Cat Ref. No. Ausp023pn40 43 L&T Make 3 Pole Power Contactors Conforms To Is Oriec 60947-4-1 & Iec 60947-4-1 Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mx 0 Nc & No Inbult Type 22E Cat- Cs94020 44 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx A1 Addon-22E Mini Power Contactor With Relay 45 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx 9 ( 1 No ) 46 L&T Make 3 Pole Power Contactors Conforms To Isor Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx 18 No. Of Inbult Addon 1No 47 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx 25, No. Of Inbult Addon -Nil 48 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx 50 49 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx 70 50 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mnx 95, 2 No +2 Nc, Cat Ref. No. Cs94136 51 L&T Make 3 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mx 9 No. Of Inbult Addon 1Nc 52 L&T Make 4 Pole Power Contactors Conforms To Is Or Iec 60947-4-1 & Iec 60947-4-1, Coil Supply 240V Ac, 50Hz, Rated Insulation Voltage Ui 690V By 1000V Of Type - Mcx 23, ( No. Of Inbult Addon - 1No ) Cat. Ref. No. Cs97018 53 Hrc Fuse - 63A Cylindrical Fuse Links Type Hf Suitable For Type Fn 63 Or Fnx 63 S-D-F & For Hc 63 Fuse Base, Cat Ref No. Sf90159 54 Hrc Fuse - 200A Din Type Fuse Links Type Hn Suitable For Type Fn 250 By 315 Or Fnx 250 By315 S-D-F & For Hb 250 Fuse Base 55 Hrc Fuse - 100A Bolted Fuse Links Type Hg And Hq, Centre Tag, 2 Holes, Suitable For Type Fn 200 S-D-F Cat Ref. No. St30775 56 Hrc Fuse - 200A Bolted Fuse Links Type Hg And Hq, Centre Tag, 2 Holes, Suitable For Type Fn 200 By 250 S-D-F Cat Ref. No. St30779 Supply Of Critical Electrical Spares Of Larsen And Toubro Total Quantity : 152

Key Value

Document Fees
Refer document
EMD
INR 42213.0 /-
Tender Value
INR 21.10 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail