Tender For Repair Replacement Of Street Light Fittings Security Light Fittings, High Mast Flood Light Fittings And Allied Work 750 Su Under Age Em Ge Af2 Jodhpur Repair Maint Of Old Rusted Pipeline Motors Pumps, Ro Plant Water Purifier And Cleaning O, jodhpur-Rajasthan

Military Engineer Services-MES has published Tender For Repair Replacement Of Street Light Fittings Security Light Fittings, High Mast Flood Light Fittings And Allied Work 750 Su Under Age Em Ge Af2 Jodhpur Repair Maint Of Old Rusted Pipeline Motors Pumps, Ro Plant Water Purifier And Cleaning O. Submission Date for this Tender is 02-05-2024. Halogen Light Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43098608
Corrigendum : Tender For Repair Replacement Of Street Light Fittings Security Light Fittings, High Mast Flood Light Fittings And Allied Work 750 Su Under Age Em Ge Af2 Jodhpur Repair Maint Of Old Rusted Pipeline Motors Pumps, Ro Plant Water Purifier And Cleaning O
Open Tender
Indian
Rajasthan
jodhpur
02-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Replacement Of Street Light Fittings Security Light Fittings, High Mast Flood Light Fittings And Allied Work 750 Su Under Age Em Ge Af2 Jodhpur Repair Maint Of Old Rusted Pipeline Motors Pumps, Ro Plant Water Purifier And Cleaning Of Oht Tank

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Apr-2024 Corrigendum 01 BOQ 25-04-2024
2 16-Apr-2024 Corrigendum02 Date 25-04-2024
3 16-Apr-2024 Corrigendum 01 BOQ 25-04-2024
4 25-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
da674059-47a9-47bb-84af-29f656ca964d.html Tender Notice 0 KB
BOQ_726679.xls Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : Repair/replacement of street light fitting security light fittings, high mast flood light fittings and allied work at 750 SU under AGE E/M, GE(AF) No2 Jodhpur, Repair/maint of old rusted pipeline, motors/pumps, RO plant, water purifier and cleaning of OHT tank & UG sump and allied works at AF Stn Mandore, Repair/replacement of DG sets, AmF Panels, Earthings and certain E/M eqpts and plants including misc E/M repairs to installations at AF Stn Jodhpur & Repair/maint of LT cable, LT panels, MCCBs and GI earthing/Chemical earthing pits, surge protection devices , lightening arrestors and allied works at Mandore under AGE E/M GE (AF) No2 Jodhpur
Sl. No. Item Description
1Excavation in trenches n.exc 1.5 Mtr wide and n.exc 1.5 Mtr in depth in hard/dense soil and getting out complete all as directed.
2Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n.exc 25cm complete all as directed.
3Removal of excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
4M&L sand cushioning / filling for underground cable protection, filling under floors ,consolidated and compacted with clean dry sand complete all as specified and as directed.
5M & L stone Slab40 to 50 mm thick rough dressed jodhpur stone patties/ slab cover in trenches for protection of cable 25 to 30 CM wide and thickness not less than 50 mm in length lay dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning.
6Supplying and fixing in replacementof under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with standed aluminium conductor 4 core 16 sqmm laid in trenches/ duct/ pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge.
7All as per itme No 6.00 above but 3.5 core 25 Sqmm
8All as per itme No 6.00above but 3.5 core 35 Sqmm
9All as per itme No 6.00 above but 3.5 core 240 Sqmm
10S&F in replacement LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 25-50 Sqmm 3.5 core all as directed.
11S&F in replacement LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 70-120 Sqmm 3.5 core all as directed.
12S&F in replacementLT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 150-185 Sqmm 3.5 core all as directed.
13Supply & jointing in replacementcable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrinkable type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95Sqmm including taking out old unserviceable jointing kit complete all as specified and as directed.
14Supply & jointing in replacementcable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrinkable type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95Sqmm including taking out old unserviceable jointing kit complete all as specified and as directed.
15Supply & jointing in replacement cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95Sqmm including taking out old unserviceable jointing kit complete all as specified and as directed.
16M&L for detecting of fault in 11KV (E) HT Cable 3 core of any size laid in trenches/ducts with the help of elecronic fault locating machine comprising of surge generator pulse, echo fault locator with high frequency distance calculator etc, exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as specified and as directed by Eng- in Charge.Note: (i) The quoted rate shall deemed to include for the cost of excavation, earthwork as required. (ii) Cable & jointing kit if replaced shall be measured and paid separately under relevant items in the Schedule.
17Supply and fixing MCCB in replacement of 100 Amps, 3 pole, 415 volts, 50 HZ, rupturing capacity 16KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
18Supply and fix MCCB in replacement with thermal magnetic release adustable type DU 160, 160A, 36KA, 415 Volts 3 pole all as specified & directed.
19Supply and fix MCCB in replacement with thermal magnetic release adustable type DN2-250D, 250A, 415 Volts 4 pole 36KA all as specified & directed.
20Supply and fix MCCB in replacement with thermal magnetic release adustable type DN3-400D, 400A, 415 Volts 4 pole 36KA all as specified & directed.
21M & L in repairGI tubing Lightgrade 50mm incl all accessories for protection cable complete all as specified and directed in engr-in-chage
22PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregates as in foundation of poles etc filling and mess concrete complete all as specified.
23PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in foundation of poles etc filling and mess concrete complete all as specified.
24Checking ofearth registance of 80 earthing (copper earth pits/ chemical earth pits/GI earth pits)and E-N voltage monthly with calibrated earth tester meter and multimeter including recharging of earthing with chemical ,maintaing of earth testing record and rectification of blockage earth pits ,rectification of earthing related fault also complete all as specified and as directed by engr in charge. Note:- (a) Chemical required for recharging of earthing shall be paid separtely. (b) Measurment of one month shall be treated as one job.
25S&F in replacement galvanized iron strip of size 32 x6 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed.
26S&F in replacementcopper strip of size 32 x6 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed.
27S&F in replacementcopper strip of size 20 x3.15 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed.
28M&L for carrying out brazing to existing earthing strip joint in between earthpit to test point after removing the nut bolt ,scraping the strip,preparing the hole and fixnew copper bolt and nut the surface all as specified by Engr-in-charge Note - length of brazing 75mm minimum for jointing of strip.
29Material and labourin repairs for electric Welding of existing GI strip of any size, any height (on roof/ on wall) at various places complete all as specified and directed by Engr in Charge.
30M& Lin repairs for porcelin insulater fixing on wall for supporting the copper strip at distance 45 cm including nut bolt drilling hole etc complete all as specified and directed by Engineer-in-charge.
31M & Lin repairs for GI funnel and wire mesh for earth pits complete all as specified & directed by Engr in Charge.
32Material and labour for Test point terminal block in repairs as made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified & directed by Engr in Charge.
33Taking down old broken and damaged earth pit chamber and M & L for construction ofnew earth pit chamber of size 600 X 600 X 300 mm of PCC 1:2:4 Type B-1including colour of earth pit chamber red/green/yellow/whiteall as specified and directed by Engineer-in-charge.
34M & L for PCC 1:2:4 with 20 mm grade aggregate including demolation of existing foundation all as specified and as directed by Engineer in charge.
35Material and labour in repairs for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32 x 6mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No 3 of SSR- 2009 (Part-1)
36Material & Labourin repairs for Chemical Earthing complete withcopper earth plate electrode 90cm x 60cm x 5mm thickness burried directly in ground (earth pit not less than 2.5mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl copper strip 32x6mm by means of nuts & bolts, check nuts and washers of brass made of copper and connected to test point and earth dolly al as shown in electrical plate no 3 SSR part I 2009 ans specified or indicating including providing charcoal dust 100 kgs ,common salt 150 kgs ,magnisum sulphate 200 kgs and all around the plate 15CM depthand wide upto 650mm height in continuous layer ,balance pit will be filled with vegaetable soil upto groundlevel including excavation and earth work in any type of soil PCC (1:3;6) type C1 in chamber ,precast concrete (1:2:4) type B1,reinforced with welded steel wire fabric orXPMweightnot less than 4 Kg/Sqm with cast iron frame ,funnel with wire mesh 40 mm bore light grade GI watering pipe all asspecified and testing on completion.(Note:-theearth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately)
37Supply, and fixing in repair of wall mounted sounder with strobe lights, back plate, control module complete all as specified and as directed..
38Supply and fixing in repairs addressable manual call point resattable typecomplete allasspecified and directed.
39Supply and fixing in repairs fire alarm sounders/sirens electronic type horizantal two stage continous normal operation atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 m with sound output variation of + 5 db 2000 m rangecomplete allasspecified and directed.
40Supply and laying in repairof GI pipes medium grade with fitting laid in trenches/wall /ground surfacecomplete for the 20 mmsizes for eathing pits water connectioncomplete all as specified and as directed.
41Material and labour of topup of potassium nitrate (commerical name Kalmi Shora) in the earthing chambers for improvement existingof earthing registance vlaue complete all as specified and as directed.
42Material and labour of topup of common saltin the earthing chambers for improvement existingof earthing registance vlaue complete all as specified and as directed.
43Material and labourof 20-25 mm thick Kota stone earth pit cover of size 2 ft X 2 ft complete all as specified and as directed.
44Material and labour in repair of bib tap 20 mm dia standered of PTMT any colour high pressure screwed for iron pipecomplete all as specified and as directed.
45S&Fand testing in replacement of energy efficient LED street light fitting of 60 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protection complete all as specified and as directed.
46S&Fand testing in replacement of energy efficient LED street light fitting of 70/72 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protection complete all as specified and as directed.
47S&Fand testing in replacement of energy efficient LED street light fitting of 90 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protectioncomplete all as specified and as directed.
48S&Fand testing in replacement of energy efficient LED street light fitting of 120 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protectioncomplete all as specified and as directed.
49S&Fand testing in replacement of energy efficient LED Flood light fitting of 150 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protectionofcomplete all as specified and directed .
50S&Fand testing of energy efficient LED Flood light fitting of 200 watt pole mounting comprising a diecast aluminium houing with heat resistant toughened glass with frame IP 66 protectionof complete all as specified and directed .
51M&L for disconnecting electric connection and dismantling U/S LED driver form led light fittings and fixed new driver50/ 60 watt complete all as specified and as directed.
52M&L for disconnecting electric connection and dismantling U/S LED driver form led light fittings and fixed new driver 70/72 watt complete all as specified and as directed.
53M&L for disconnecting electric connection and dismantling U/S LED driver form led light fittings and fixed new driver 90/100 watt complete all as specified and as directed.
54M&L for repair of mechanism of highmast and rewinding of three phase high mast tower motor 440 volt AC 1HP 1425 RPM if burnt and incl dismantling form highmast transportation to workshop for rewinding with existing size of super enamlled copper wire replacing of gear,bearing bush ,greashing varnishing etc for running of rope at satisfactory level and reinstalation complete all as specified and as directed.
55M & L for PVC insulated copper conductor4 sqmm 10 core complete all as specified and as directed.
56Supply and fixing in replacement of high mast panel with complete copper wiring ,ML contractor 4 pole AC3 18Amp 9 KW -03 Nos,Timer 32 Amp, TPN MCB 63 Amp with complete busbar and including taking down old panel complete all as specified and as directed by Engineer-in-Charge.
57Supply and fixing MCCB in replacement of 63 Amps, 3/4 pole, 415 volts, 50 HZ, rupturing capacity 16KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
58Supply and fixing MCCB in replacement of 160Amps, 3/4 pole, 415 volts, 50 HZ, rupturing capacity 36KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
59S & F in repair GI Bracket for mounting street light fittings made out of light grade 32mm GI pipe and have angle of 120 degree incl fixing arrangement complete all as specified and as directed by engr-in-charge.
60Supply and fix single core PVC insulated FR cable with multi stranded copper conductor 1.5 sq mm cross sectional area 3 core ,1100 volts grade all as specified and as directed.
61Supply and fixing in replacement of automatic street light switch using Nature switch for automatic switching of street light based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor , MCB and support terminals should be encloused in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC juction box (sintex make) conorming to IP 54. The contactor, MCB and copper circuit should suitable enough to take 3 phase load of 5 KW, contactor rating 25-32 Amps per phase, MCB SP rating of 32 Amps (03 Nos)
62M/L for Repairs to out door LTpanel including taking down for repair as follows :-( a )Supply and fixing of MS sheet 16 SWG( 1.6mm ) and fabrication of back side cover of LT panel including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of coats of synthetic enamel paint over a coat of red oxide.(b ) Supply and fixing of hinges , tee type stove enamelled black medium weight , cold rolled and mild steel 30 mm size and fixed door shutters .( c ) Supply and fixing of locking arrangement with MS sliding door bolts hasp and suitable for use with pad lock of size 200 mm.( d ) Mild steel work conforming to Fe-410-0 or Fe-310-0 as in angle iron frame work , cut to size including bending and welding angles as necessary and re -fixing of MS sheet of panel including a shop coat of red oxide primer.
63M&Lin replacement HERITAGE LED Post Ideal to lit up parks, garden ways and heritage sites 20 Wattscomplete all as directed by Engr-in -Charge Make :Crompton cat pat no -LPTH-20-CDL or eqult Havells/Bajaj/Surya
64M&L in replacementof Inverted Tripod type LED bollard light 10 watt with soft light disturbutioncomplete all as directed by Engr-in -Charge Make :Crompton cat pat no -LBLSN-10-CDL or eqult Havells/Bajaj/Surya
65Supply and fixing in Replacement DigitalAmmeter and Voltmeter set with connected wiringcomplete all as directed by Engr-In-Charge
66Supply and fixing of copper thimbles using crimping tool for electrical connections with cable and connecting with suitable size of nuts / bolts and washers of size 120 sqmm to 185 sqmm LT cable size.
67Supply and fixing of copper thimbles using crimping tool for electrical connections with cable and connecting with suitable size of nuts / bolts and washers of size 25 sqmm to 95 sqmm LT cable size.
68Supplying and fixing in replacement of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in duct/ pipe including all electrical connection with required lugs and nuts, bolts complete incl taking down old cable all as specified and directed by Engr-in-Charge.
69M&LGI tubing Lightgrade 50 mm incl all accessories for protection cable complete all as specified and directed in engr-in-chage
70S & F in replacement Change over main switch, on load, four poles, 100 Amps, 415 Volts, with enclosure, fixed in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
71Material and labour for paintingabove the coppingupto 1.5 mtr in alternatively black and white strips of 30 cm each & rest of the portion with two coats of silver/aluminium paint on steel tubular LT pole of any height after scrapping/removing the existing paint and the preparation the surface of steel tubular pole LT including painting of the channel cross arms, nut, bolts & washer, street light bracket and clamps complete all as specified and directed
72S & F in repairs Mild steel work in framed work such as grills, Gates, Framed guard bars, gratings, ladders, Cable trays, Fencing etc., with ends of bars soldered/welded and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O incl two coats of mettallic paint over a coat of mettallc primer incl taking down old rusted steel work as directed.
73Supplying and fixing in replacement of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with standed aluminium conductor 2 core 10 sqmm laid in trenches/ duct/ pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge.
74S & F double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II ) for protection of underground cable .Outer dia of pipe 50 mm with all fitting laid in trenches/road/nallah or fixed along wall ,poles or laid under floor (including cutting floor /Road and making good to match with existing adjointing surface etc for cable protection all as specifiedand as directed.
75S&F in replcementFRP junction box for street light central with linked door control incl 6 amp MCB SP with aluminium bus bar-04 nosfor controling street light/garden lightcomplete as directed by Engr-in-Charge.
76Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete.
77Material and labour for substation yard spreading levelling with 20 mm graded coarse aggregate /gravells laid approximately 75 mm thick layer near VCB/Transformer /2/4 pole structure and plateform etc complete all as specified and as directed.
78Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
79Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, pier holes, for foundations of poles, struts, stays etc. or layingunderground cable and water supply pipe lines etc.in hard/dense soil/rocks,& getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
80Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil/\ complete all as specified and directed by Engineer-in-charge.
81Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
82Taking up or down 15mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately.
83All as per Srl item No 82 above but 20 mm dia bore.
84All as per Srl item No 82 above but 25 mm dia bore.
85All as per Srl item No 82 above but 40 mm dia bore.
86All as per Srl item No 82 above but 50 mm dia bore.
87All as per Srl item No 82 above but 80 mm dia bore.
88All as per Srl item No 82 above but 100 mm dia bore.
89S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
90All as per Srl item No 89 above but 20 mm dia bore.
91All as per Srl item No 89 above but 25 mm dia bore.
92All as per Srl item No 89 above but 40 mm dia bore.
93S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge.
94All as per Srl item No 93 above but 80 mm dia bore.
95Supplying, laying, jointing, commissioning and testing 100mm bore centrifugally cast (Spun)ductile iron pressure pipe with spigot and socketed ends class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties suitable for rubber gasket jointing / tyton joints with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i)DI fittings shall be measured and paid separately under respective items (ii)Pipes shall be laid in trenches already excavated for taking out old GI pipe line. Extra excavation / earthwork shall not be paid.
96S&F in replacement gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
97All as per Srl item No 96 above but 25 mm dia bore.
98All as per Srl item No 96 above but 40 mm dia bore.
99All as per Srl item No 96 above but 50 mm dia bore.
100Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80 mm bore, ISI marked with IS 14846 : 2000, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete, all as specified & directed.
101All as per Srl item No 21 above but 100 mm dia bore.
102S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 80mm bore pipe, ISI marked, conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete, all as specified & directed.
103All as per Srl item No 102 above but 100 mm dia bore.
104Supply and fix Foot Valve conforming to IS 4038, 80 mm (4”) dia complete all as specified and directed by Engineer-in-charge.
105All as per Srl item No 104 above but 100 mm dia bore.
106Supplying & fixing DI fittings confirming to IS-9523-2000 suitable for spigot & socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc),tee pieces, single branch, "Y" junction, double branch, cross collar, caps and plugsetc. suitable for spigot and socketed pipes upto 150 mm bore, complete, all as specified and directed by Engineer-in-charge.
107M&L for Construction of brick masonry valve pit, in repair, of internal size 60cm x 60cm x 60cm including necessary excavation and earth work in soft/loose soil, brick work,plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thickfixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock ,complete all as specified and directed by Engineer - in - Charge Note :- (i)Brick wall shall be 23 cm thickbuilt incement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit. (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation.
108All as per Srl item No 107 above but internal size 90cm x 90cm x 90cm
109All as per Srl item No 107 above but internal size 150cm x 150cm x 90cm
110M&L for "D" Joint suitable for DI /CI/GIpipe sizes 50 mm dia bore including excavation work and other fittings as required including testing at site complete all as specified and directed by the Engineer-in-Charge.
111All as per Srl item No 110 above but 80 mm dia bore.
112All as per Srl item No 110 above but 100 mm dia bore.
113M & L for cleaning of RCC underground sump of capacity 50000 Gallons at AF Stn Mandore , dewatering the sump with water lifting pump , de-scaling internal surfaces of underground sumps with wire brush , removing the deposited mud from inside the sump , washing with bleaching powder & flush water two times and dewatering, applying two coats of lime wash inside the sump including writing capacity of tank , date of cleaning with synthetic enamel paint of white tint over black base (size of letter 5 mm thick and 15 cm in height) complete all as specified and as directed.
114M & L for cleaning of RCC underground sump of capacity 50000 Gallons atBalsamand site AF Stn Mandore , dewatering the sump with water lifting pump , de-scaling internal surfaces of underground sumps with wire brush , removing the deposited mud from inside the sump , washing with bleaching powder & flush water two times and dewatering, applying two coats of lime wash inside the sump including writing capacity of tank , date of cleaning with synthetic enamel paint of white tint over black base (size of letter 5 mm thick and 15 cm in height) complete all as specified and as directed.
115M & L for cleaning of RCC OHT capacity 50000 Gallons at AF Stn Mandore by descaling internal surfaces of OHT with wire brush , removing the deposited mud from inside tank , washing with bleaching powder & flush water two times and dewatering including writing capacity of tank , date of cleaning with synthetic enamel paint of tint white over black case (size of letter 10mm thick and 20 cm in height) complete all as specified and as directed
116Cleaning of SWT pumping outcomplete/flushing out dirty water mud sludge dirt etc from inside the SWT by mud pump/bucket (Manually), cleaning in side walls, top & bottom surface of the SWT scraping, with wire brush, removing mud and sludge etc from tank to a distance upto 50 mtrs and depositing all as directed by Engr-in-Charge at site washing the SWT/pipes with bleaching powder solution and finally applying cement coat with 2% of potassiumpermanganate solution for disinfection all as directed by Engr-in-Charge including making with black paint of static water tank cleaned on dt of following capacity/depth :-
117SWT of capacity 50000 Ltrs at Near OHTAF station Mandore.
118SWT of capacity 50000 Ltrs at Near MT sectionbldg AF station Mandore.
119SWT of capacity 50000 Ltrs at Near Arnoc Bldg bldg AF station Mandore.
120Comprehensive maintenance servicing and testing of RO plant of 1000 Ltrs/hr capacity including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set &dosing unit for supply qualitative water at permissible level of TDS as and when directed by Engr-in- charge.
121Supply & fix sediment filter/pre filter Jambo 2011 as per existing make and modelfor 1000 ltrs RO Plant.
122S&F RO Membrane for 1000 ltrs RO Plant complete all as specified and as directed.
123M&L Carbon media for 1000 ltrs RO plant.
124M&L Resin media for 1000 ltrs RO plant .
125M&L Sand suitable for RO plant.
126S&F Automatic control panel microprocessor based with on line TDS meter complete.Make- Hitech or equivalent.
127S&F Vessel FRP 13.5". Make- Pentair or equivalent.
128S&F Multi port valve in / out of size 1.5".
129S&F superior quality PVC/CPVC/UPVCheavy duty pipe size 25 mm.
130M&Lantiscalant chemical for RO Plant.
131S&F pre filter housing of 1000 ltrs of RO plant as per existing make and model all as specified and as directed.
132S&F FloatyvalveAuto cut system in existing control panelfor 1000 ltrs RO Plant complete all as specified and as directed.
133S&F solonoid valve for 1000 ltrs RO Plant complete all as specified and as directed.
134Comprehensive maintenance servicing and testing of water purifier AG 600 DFincluding washing, cleaning offilter, disinfection processcomplete all as specified and directed by Engr-in- charge.
135M&Lpre filter candle204 as per existing make and modelfor water purifier complete all as specified and as directed.
136Supply and fix pressure gauge air water meter of pressure range 0-10 kg/sqcm complete all as specified and as directed.
137Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
138M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
139M&L for complete removal of existing paint of pipeline of dia 80mm to 150mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
140M&L for taking out of Monoblock motor 20/30 HP Capacity installed as motor from foundation after disconnecting electrical connections, dismantling motor and rewinding the same with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, reassembling and fixing the same in its original position including replacement of unserviceable nut-bolts, washer, lugs, terminal plate and making proper electrical connection complete all as specified and directed by Engineer-in-charge. Make of winding wire : - Devidayal / Chetak Note : - (i) Bearing if required for replacement shall be paid separately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account.
141All as per serial item No. 137here-in-above but monoblock pump set of capacity 7.5 /10HP
142Supply only CI impeller suitable for monoblock pump set of capacity 20/30 HP motor complete all as specified and directed by Engineer-in-charge. Make: Kirloskar
143All as per serial item No 139 here-in-above but of capacity 7.5 /10 HP Motor
144Supply only stainless steel Bush suitable for monoblock pump set of capacity20/ 30 HP motor complete all as specified and directed by Engineer-in-charge.
145.All as per serial item No 141 here-in-above but capacity with 7.5 /10HP Motor
146M&L for rewinding of Monoblock motor set of capacity 20/30 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge Make of winding wire : - Devidayal / Chetak
147.M&L for rewinding of Monoblock motor set of capacity 7.5 /10HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge Make of winding wire : - Devidayal / Chetak
148Supply only ball bearing suitable for monoblock pump set of capacity 30 /20 HP motor complete all as specified and directed by Engineer-in-charge. Make: NBC / SKF / TATA
149All as per serial item No 67 here-in-above but capacity 7.5/10 HP Motor
150Supply and fix DOL starter for 2 HP submersible motor complete all as specified and as directed by Engineer–in-charge.Make -Havells model No-IHSDOAHB*A
151Supply and fix Fully automatic star delta starter for 7.5/10 HPmotor complete all as specified and as directed by Engineer–in-charge.Make -Havells model No-IHPASDQD*A
152S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
153S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase, as suitable range, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
154M & L to carry out laser calibration of underground horizantal BPI tank capacity :15 KL tolerance (+-)75 ltr ,which include the following in the scope of job. (a)Method to be used :API MPMS 2.2E/IS 2007 & IS 2166 method for measurment and calibration of U/G tanks. (b) Internal circumference and internal diameter with laser (along horizontal and vertical axis) and along external diagonals will be recorded at positions around the inside and outside of the tanks and also along the dip line with accurate calibrated laser distance meter with ablity to measure maxima and minimum distance over a transverse sweep .these reading along all the strakes /courses will be used to determine 2 mean diameter horozintal and vertical complete all as specified and as directed. (c) End shape will also be measured .tank tilt with lasers will be measured. (d) internal deadwoods will be deducted. (e) All data will be analyzed for correction of sphereradius anomalies ,liqid head stress ,dataum height ,varying internal diameters,calibration table will be made at interval of 5 mm throughout.softcopy in excel formet woll be providing foruploding of data and complete satisfaction by engr-in charge.
155M & L to carry out cleaning of 15 KL BPItank internal surfaces of the tank including labor,cost of raw material like gasket nut bolts ,disconnected of pipeline and refitted complete satisfaction by engr-in charge.
156M & L for Rimdol 400 fill with drinking water 400 PPM complete all as specified and as directed by engr in charge.
157Periodical maintenance and inspection/checking of following size /capacity of DG sets and ensuring smooth functioning of DG sets and replacements of unsv parts of DG sets of following capacities : - Note:- Spare parts required shall be measured and paid separately .
15840 KVA DG SET
159160 KVA DG SET
160320 KVA DG SET
161Supply and fixing in Replacement bypass filter element with O ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and modelfor the following capacities of DG Sets :-
16240 KVA DG SET
163160 KVA DG SET
164320 KVA DG SET
165Supply and fixing in Replacementluberication oil filter element with "O" ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and modelfor following capacities of DG Sets:-
16640 KVA DG SET
167160 KVA DG SET
168320 KVA DG SET
169Supply and fixing in ReplacementAir filter elementinner and outer as required at site with "O" ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets:-
17040 KVA DG SET
171160 KVA DG SET
172320 KVA DG SET
173Supply and fixing in Replacementfuel filter element with "O" ring ofKirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets:-
17440 KVA DG SET
175160 KVA DG SET
176320 KVA DG SET
177Supply and fixing in Replacementfan belt of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for the following capacities of DG Sets:-
17840 KVA DG SET
179160 KVA DG SET
180320 KVA DG SET
181Supply and fixing in Replacement distilled water to be filled in batteries ,complete all as specified and directed by Engineer-in-charge.
182Supply and fixing in Replacementignition switch with key in repair for DG sets of any capacities, complete all as specified anddirected by Engineer-in-charge.
183Material & Labour for replacement of battery cable of size 40 sqmm PVC insulated multi stranded copper conductor singlecore cable with necessary lugs, complete all as specified anddirected by Engineer-in-charge.
184Supply and filling in Replacementtop up coolent for DG set radiator
185Supply and fixing in Replacement Water temperature gauge for 320 KVA DG set complete all as specified and as directed.
186Supply and fixing in Replacement oil pressure gauge assembly for 40 KVADG set complete all as specified and as directed.
187Supply and fixing in Replacement oil temperature gauge for 320 KVA DG set complete all as specified and as directed.
188Supply and fixing in Replacement cable for Techno meter for 320 KVA DG set complete all as specified and as directed.
189Supply and fixing in Replacement Techno meter assembly for 320 KVA DG set complete all as specified and as directed.
190Supply and fixing in Replacement flexible braided hydraulic hose 5/8" dia x 600 mm length includingsuitable check nuts & washers, complete all as specified anddirected by Engineer-in-charge.
191Supply and fixing in Replacement RPM metre with cable (0-3000 RPM),, complete all as specified anddirected by Engineer-in-Charge.
192Supply and filling in Replacement lube oil SAE 15 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling, complete all as specified anddirected by Engineer-in-charge. Make : Castrol/Power Supreme
193Supply and fixing in Replacement battery terminal heavy duty as per sample made of brass with bolts and washers all as required at site,, complete all as specified anddirected by Engineer-in-Charge.
194Supply and fixing in Replacement complete 12 V180 AMPH maintenance free battery and initial charging complete including inbuilt charger including required electrolyte /distilled water etc and fixingas required at site to the concerned DG Set, complete all as specified anddirected by Engineer-in-charge.
195Supply and fixing in Replacement of self starter assembly for DG set of 40 KVA 12 volts DC including, complete fixing and testing, complete all as specified anddirected by Engineer-in-charge. Make:-Lucas-TVS
196Supply and fixing in Replacement Rubber hose set for DG set radiator by replacing the unserviceablehose set ,for40 KVA DG setcomplete all as specified as directed by Engineer-in-charge.
197Supply and fixing in Replacement PLC system for DG sets of 40 KVA capacities , complete all as specified as directed by Engineer-in-charge.
198Supply and fixing in Replacementof turbo charger,320complete all as specified as directed by Engineer-in-charge. Make:- Holest or equivalent as approved.
199Material and labour for dismantling of radiator from engine taking it to work shop repair of leakage pipes, cleaning the radiator with cleaning agents, re-assembling to the engine completely to entingsatisfaction of Engineer-in-Charge
200Inspection/checking of AMF panelof DG set of capacity 40 KVA to 320 KVA installed at various installations of any make and shape and rectify the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry outmaintenance , complete all as specified as directed by Engineer-in-charge.Note:- Spare parts required shall be measured and paid separately .
201Supply and fixing in Replacement 4 Pole power contactor with AC coil 160 Amps, 3 phase 415 volt 50 HZ suitable for AMF panelscomplete all as specified as directed by Engr-in-Charge Make:-Havells model No-IHPAC065500
202Supply and fixing in Replacement engine start relay 12 volt DC suitable for AMF panels Complete all as specified as directed by Engr-in-Charge Make:- Eagle Man/PIC
203Supply and fixing in Replacement frequency meter 45 to 55 HZ AC 415 volt of size Sqmm suitable for AMF panelscomplete all as specified as directed by Engineer-in-Charge. Make:- AE/Premier.
204Supply and fixing in Replacement selector switch for volt/ampere metre 415 volt four stage suitable for AMF panels Complete all as specified as directed by Engr-in-Charge Make:- L&T/CONCORD/KAYCEE/C&S
205Supply and fixing in Replacement cranking relay 12/24 volts DC 8/11 stage suitable for AMF panelscomplete all as specified as directed by Engineer-in-Charge. Make:- Eagle Man or equivalent as approved
206Supply and fixing in Replacement indicator lamp assembly LED type with red/green/blue for phases R,Y,B suitable for AMF panels complete all as specified as directed by Engineer-in-Charge.
207Supply and fixing MCCB in replacement of 100 Amps, 3 pole, 415 volts, 50 HZ, rupturing capacity 16KA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed.
208Supply and fix MCCB in replacement with thermal magnetic release adustable type DN2-250D, 250A, 415 Volts 4 pole 36KA all as specified & directed.
209Supply and fix MCCB in replacement with thermal magnetic release adustable type DN3-400D, 400A, 415 Volts 4 pole 36KA all as specified & directed.
210S & F Change over main switch, on load, four poles, 630 Amps, 415 Volts, 36 KA ,50 Hz, with enclosure, fixed in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make: Havells model No-IHCNF00250
211M/L for Repairs to out door LTpanel including taking down for repair as follows :-( a )Supply and fixing of MS sheet 16 SWG( 1.6mm ) and fabrication of back side cover of LT panel including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of coats of synthetic enamel paint over a coat of red oxide.(b ) Supply and fixing of hinges , tee type stove enamelled black medium weight , cold rolled and mild steel 30 mm size and fixed door shutters ( c ) Supply and fixing of locking arrangement with MS sliding door bolts hasp and suitable for use with pad lock of size 200 mm( d ) Mild steel work conforming to Fe-410-0 or Fe-310-0 as in angle iron frame work , cut to size including bending and welding angles as necessary and re -fixing of MS sheet of panel including a shop coat of red oxide prime
212Supply and fixing of copper thimbles using crimping tool for electrical connections with cable and connecting with suitable size of nuts / bolts and washers of size 120 sqmm to 185 sqmm LT cable size.
213Supply and fixing of copper thimbles using crimping tool for electrical connections with cable and connecting with suitable size of nuts / bolts and washers of size 25 sqmm to 95 sqmm LT cable size.
214Supply and fixing in replacementof under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with standed aluminium conductor 4 core 16 sqmm laid in trenches/ duct/ pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge.
215All as per itme No 194 above but 3.5 core 25 Sqmm
216All as per itme No 194 above but 3.5 core 240 Sqmm
217All as per itme No 194 above but 3.5 core 300 Sqmm
218Material and labour in repair for earthing complete with copperplate electrode 60cmx60cmx3.15mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 20 x 3 mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and directed.
219S&F copper strip of size 20 x3 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed.
220Suppyling, installing, testing and commissioning in replacement of outdoor type factory made ,CRCA sheet ,thickness 3.15mm,platform mounted LT panel board to accommodate the following items and built upon angle iron frame suitable size compatmentalized design work ,dully powder coated with gray paint and suitable size of cable glands chromium plated and copper busbars TPN,400 Amps,415V,50Hz complete as following:- (i) MCCB 200 Amps,4 pole,36 Ka -01 (incoming) (ii) MCCB 100 Amps,4 pole,25 Ka -02 (outgoing) (iii) Voltmeter 0-500 V digital type with selector switch - 1 No. (iv) Amp meter 0-200 A digital type with selector switch -1 No. (v) fully automatic star delta starter suitable for 12 HP -02 (vi) Indicating lamp LED RYB set of three with colour coding -1 No.