Public Works Department-PWD has published Tender For Construction Of Circuit House At Sarli, Under Sarli Circle, Kurung Kumey. Submission Date for this Tender is 08-04-2024. Building Work Tenders in Kurung Kumey Arunachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SH:-Building Portion=1.00 Job |
2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
3 | Providing & injecting Chemical emulsion for pre-constructional antitermite treatment and creating a chemical barrier under and around the column, pillars, Walls, trenches, basement, excavation, top surface of plinth, filling, junction of Wall and floor along the external perimater of building, expansion joints., surrounding of pipes and conduits etc. complete. (plinth area of the building at ground floor only shall be measured.) |
4 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
5 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
6 | SH : CONCRETE WORK Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundation and plinth |
7 | SH : RCC WORK Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
8 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
9 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement a) M20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
10 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
11 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
12 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
13 | b) Columns, pillars etc.. |
14 | c) Lintels, beams, girders, bressumers and cantilevers etc. |
15 | d) Suspended floor |
16 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel. |
17 | SH : BRICK WORK Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
18 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
19 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
20 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
21 | WOOD WORK Providing approved best available local wood (Class-B II) work in frames of doors, windows clerestory windows and other framed fixed in position. |
22 | Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12 mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer. a) 40mm thick i/c anodized alluminum butt hinges with necessary screws |
23 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round barswith roundheaded boltsand nuts or by screws. b) Ornamental grill |
24 | Steel Work Provinding and Fixing stainless steel (Grade 304) railing made of Hollow tubes, channel, plates etc. including welding, grinding ……………………….. (for payment purpose only weight with of stainless steel member shall be considered excluding fixing accessories such as nut, bolt, fastener etc. |
25 | Steel Work welded in build up section / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structureral steel etc. as separately. A) in stringers, treads, landing etc. of stria cases, included use of chequered plate wherever required, all complete. Qnty from sheet No.14 |
26 | ALUMINIUM FITTINGS Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) 4.3 With float glass panes of 8mm thickness |
27 | FLOORING Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. c) 75mm thick |
28 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor. b) 21 mm thick |
29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete b) Size of Tile 600x600 mm |
30 | FINISHING 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
31 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall. |
32 | 6 mm cement plaster to ceiling 1:3 (1 cement: 3 fine sand) |
33 | White glazed tiles 5mm thick in skirting, riser of step and dado in 12mm thick cement plaster 1:3 pointed with white cement slurry. |
34 | Providing and fixing Iron T-hinges bright finished or and black enamelled with necessary screws etc complete. a) 300x115x2.24mm |
35 | Providing and fixing MS handles with necessary screws etc complete a) 125 mm |
36 | Providing and fixing MS Hooks and Eyes e)100mm |
37 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
38 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
39 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
40 | White washing with limeon new work. (2 or more coats) to give an even shade. |
41 | White Washing with whiting on new work (Three or more coats) to give even shade |
42 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
43 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
44 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work |
45 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
46 | DRAINAGE Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
47 | MISCELLANEOUS Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
48 | WATER SUPPLY Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). b) 20mm nominal bore |
49 | Providing and fixing brass bib cock of approved quality. b) 20mm nominal bore |
50 | Providing and fixing brass stop cock of approved quality. b) 20mm nominal bore |
51 | SANITARY INSTALLATION Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-leve lflushing cistern with fittings and brackets 40mm white porcelain in enamel led flush band, 20 mm over flow pipe with specials and mosquito proof coupling of approved municipal design complete including cutting and making goodt he walls and floors where required. a) WC pan with white plastic seat and lid. |
52 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, includingcutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality |
53 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm |
54 | TOILET REQUISITES Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
55 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
56 | Providing & fixing CP bars towels rail complete with CP brass brackets fixed to wooden cleat with CP brass screws ( heavy quality). a) 750 x 20mm |
57 | Providing and fixing sand cast iron cast/iron (spun) soil, waste and vent pipes. a) 100mm dia. |
58 | Providing and fixing sand cast iron heel rest sanitary bend. a) 100mm dia. |
59 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. A) 100x100x100 mm |
60 | Polyethylene water tank storage with cover and suitable locking arrangement (2000 ltr Capacity) |
61 | Septic Tank=1.00 Job |
62 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) Hard Soil |
63 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
64 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
65 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
66 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 :3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
67 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild Steel. |
68 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
69 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement : 5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg), cement concrete 1 : 4 : 8. |
70 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy