Tender For Provision Of Shifting Of 125 Kva Dg Sets From 2Ud ( We ) Det Of 60 Weu To Newly Constructed At 60 Weu New Location Alongwith ( Pcc Plinth And Rcc Shed ) And Additional / Alternator To Bathroom Bldg No P-302 At Bikaner Mil Stn Under Ge ( N , bikaner-Rajasthan

Military Engineer Services-MES has published Tender For Provision Of Shifting Of 125 Kva Dg Sets From 2Ud ( We ) Det Of 60 Weu To Newly Constructed At 60 Weu New Location Alongwith ( Pcc Plinth And Rcc Shed ) And Additional / Alternator To Bathroom Bldg No P-302 At Bikaner Mil Stn Under Ge ( N . Submission Date for this Tender is 24-04-2024. Diesel Generators Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43091031
Corrigendum : Tender For Provision Of Shifting Of 125 Kva Dg Sets From 2Ud ( We ) Det Of 60 Weu To Newly Constructed At 60 Weu New Location Alongwith ( Pcc Plinth And Rcc Shed ) And Additional / Alternator To Bathroom Bldg No P-302 At Bikaner Mil Stn Under Ge ( N
Open Tender
Indian
Rajasthan
bikaner
24-04-2024

Tender Details

Provision Of Shifting Of 125 Kva Dg Sets From 2Ud ( We ) Det Of 60 Weu To Newly Constructed At 60 Weu New Location Alongwith ( Pcc Plinth And Rcc Shed ) And Additional / Alternator To Bathroom Bldg No P-302 At Bikaner Mil Stn Under Ge ( N ) Bikaner

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work : Provn of shifting of 125 KVA DG sets from 2UD (WE) Det of 60 WEU to newly constructed at 60 WEU new location alongwith (PCC plinth and RCC shed) and Addn/Altn to bathroom Bldg No P-302 at Bikaner Mil Stn under GE (N) Bikaner
Sl. No. Item Description
1Demolition of unreinforced cement concrete of any description and in any position (not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
2Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
3Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
4Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
5Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
6Surface dressing not exc 15cm deep in soft/loose soil complete all as specified and as directed.
7Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
8Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
9Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
10M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
11M&L for PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
12M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
13M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in columns, pillars, piers, posts, struts and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
14M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
15M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
16Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & as directed.
17Formwork to sides of pillars, posts, beam, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed.
18Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.
19S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour single piece extruded PVC profile reinforced with MS square tube, fixing in opening as per specifications complete all as specified and as directed.
20S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with plain colour single piece extruded PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour single piece extruded PVC profile for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed..
21S&F butt hinges of size 100mm stainless steel (ISI marked) complete all as specified and as directed.
22S&F 150 mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified and as directed.
23S&F extruded aluminium alloy handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified and as directed.
24S&F 250mm long mild steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified & as directed.
25S&F in repairs stainless steel drapery rod of 25mm inner dia & 1.6mm wall thickness (in lengths as directed) with & including stainless steel sockets & decorative finial at both ends and pair of stainless steel brackets & stops fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
26M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
27All as per serial item No. 26.00 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders complete all as specified & as directed.
28M&L for 100mm thick PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) as in floor and paving, surface finished fair & even (PCC shall be laid in panels as directed) including necessary formwork complete all as specified and as directed.
29M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.
30S&F plastic dividing strips, 3mm thick and width of strip 38mm for making panels in concrete complete all as specified and as directed.
31M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm including dismantling old stone slabs complete all as specified & as directed. Note :The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
32M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
33M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 450mm x 300mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
34M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as inplinth protection surface finishedeven and smooth without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall belaid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
35M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
36M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed.
37M&L for rendering 5mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces, finished even & smooth without using extra cement, complete all as specified and directed.
38M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
39M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
40M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed.
41M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed.
42M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty on walls complete all as specified & as directed.
43M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty on ceiling complete all as specified & as directed.
44M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
45S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, fixed in repair complete all as specified & as directed.
46M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
47M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, including taking up or down existing unserviceable steel water tubing and connections of 15mm bore complete all as specified and as directed.
48M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, including taking up or down existing unserviceable steel water tubing and connections of 20mm bore complete all as specified and as directed.
49M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing and making good, cutting not exc 10 cm girth in brick walls, complete all as specified & as directed.
50S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
51S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including32 mm dia PVC flush pipeconnected to water closet with inlet, ball valve, float and handle complete all as specified & as directed. Make : Cat Part No. ‘B1010102’ of ‘Cera’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
52S&F in repair vitreous china wash hand basin, white, oval of size 560mm x 400mmx205mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, complete all as specified & as directed. Make : Cat Part No. ‘S2030102’ of ‘Cera’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
53S&F in repairs vitreous china urinal, size 375x390x590mm including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60mm long brass screws, pointing around urinal back in cement, fixed automatic flushing cistern with bracket, flush pipe, grating and union for discharge pipe complete all as specified and as directed. Make : Cat Part No. ‘S4020112’ of ‘Cera’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
54S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.
55S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes, complete all as specified & as directed. Make : Cat Part No. ‘G4902A1’ of ‘Parryware’ / Cat Part No. ‘F1003104’ of ‘Cera’ / Cat Part No. ‘CQT-23011B’ of ‘Jaquar’ / Cat Part No. ‘9202’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
56S&F in repairs wall mixer, non telephonic type, brass, chromium plated,fancy type, with capstan head handles with lettered "hot" and "cold", screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection,complete all as specified as directed. Make : Cat Part No. ‘G4916A1’ of ‘Parryware’ / Cat Part No. ‘F1020403’ of ‘Cera’ / Cat Part No. ‘CQT-23281UPR’ of ‘Jaquar’ / Cat Part No. ‘9275’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
57S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed. Make : Cat Part No. ‘G4906A1’ of ‘Parryware’ / Cat Part No. ‘F1005152’ of ‘Cera’ / Cat Part No. ‘CON-107KN’ of ‘Jaquar’ / Cat Part No. ‘9208’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
58S&F in repair 15mm bore Angle valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed. Make : Cat Part No. ‘G4907A1’ of ‘Parryware’ / Cat Part No. ‘F1018201’ of ‘Cera’ / Cat Part No. "CON-059KN’ of ‘Jaquar’ / Cat Part No. ‘9210’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
59S&F in repair urinal spreader of cast copper alloy fancy type CP screwed for 15mm iron pipe or PVC connection and fixedcomplete all as specified & as directed.
60S&F in repairs Shower rose, round type, brass, chromium plated, Fancy type, 150mm dia (minimum) with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe of 15mm bore or union complete all as specified and as directed. Make : Cat Part No. ‘T9809A1’ of ‘Parryware’ / Cat Part No. ‘F7010211SS’ of ‘Cera’ / Cat Part No. ‘BOS-87’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
61S&F in repairs tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and as directed. Make : Cat Part No F5002103 of make : Cera or equivalent in makes mentioned in Appendix "B" here-in-after)
62S&F in repairs Towel ring round brass chromium plated with round flange (Cat Part No F5015115CH of make – Cera or equivalent in makes mentioned in Appendix "B" here-in-after) fixed on wall with PVC rawl plug & cadmium plated brass screws complete all as specified & as directed.
63S&F in repairs soap dish holder brass chromium plated fixed on wall with PVC rawl plug & cadmium plated brass screws complete all as specified & as directed. Make :- Cat Part No F5012116CH of make – Cera or equivalent in makes mentioned in Appendix "B" here-in-after.
64S&F in repairs stainless steel Peg Set of Six of standard size (not less than 300mm long) fixed to wall with two rawl plugs and chromium plated brass screws complete all as specified & as directed. Make :- Cat Part No BEA-30 of make – Prayag or equivalent in makes mentioned in Appendix "B" here-in-after.
65S&F in repairs Corner glass 300mmx300mm with 5.5mm thick glasss and stainless steel clip and stainless steel railing all round shelf with brass screws complete all as specified and as directed. Make : Cat Part No F5005103 of Cera or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
66S&F 5mm thick looking mirror of selected quality with and including stainless steel spacers any size complete all as specified & as directed.
67S&F in repairs Grating 75mm dia stainless steel with and without hole having minimum weight 75gm complete all as specified and as directed.
68Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
69M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etcall as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.
70All as per serial item No. 69.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
71All as per serial item No. 69.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
72All as per serial item No. 69.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
73S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.
74S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.
75S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
76S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.
77S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
78S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
79S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp,correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make : Model “LDL-10-WW” of M/S Crompton/Wipro Cat Part No. LL20-111-XXX-65NE3 / Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH of Havells/or equivalent in makes mentioned in Appendix "B" here-in-after.
80S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Philips, Cat Part No. LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix "B"
81NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
82S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, complete all as specified and as directed.
83S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, SPN, 4 way, suitable for MCB, fitted complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type. Note : Cost of cutting/leaving forming chases for sinking for DBand making good in CM 1:4 shall deemed to be included in quoted rate of this item.
84S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
85S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve,with over load and short circuit protection, complete all as specified and as directed.
86Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1.5 sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed.
87Supply, installation & testing electric Geyser (water storage type) of capacity 25 litre, vertical mounting type, glass lined inner tank, rust proof outer body, 2 KW heating element, suitable for 230V Single Phase 50 Hz AC supply, 5 Star rating, energy efficient, 8 Kg/sqcm pressure withstanding capacity, Class I, ISI marked, with & including Thermostat with Thermal Cutout, heating indicator, Multi functional valve (acts as pressure release valve, non-return valve, expansion valve and vacuum release valve), fixed all as per manufacturer’s instructions, fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original, complete, all as specified & directed.
88M&L for Earthing to equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
89M&L for sub main wiring with two runs of 10 sqmm (nominal area) size main cable & one run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI markedcables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :-(i) 02 runs of 10 sqmm size main cable, 01 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
90Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 240 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
91M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
92Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.
93Taking out old existing underground LT XLPE cable insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade and laying after disconnection from existing LT panel and properly connected to new panel complete all as specified and directed.
94Laying only, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 70 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
95Material and labour for dismantling of all existing connection and accessories of DG set installed at SI unit and shifting and installation with connection and testing at new location, including preparation of foundation for DG set with prior approval of foundation drawing by GE complete all as specified and directed. Note : (i) Tool and machinery required for dismantling and reconnection/ installation shal be deemed to be included in quoted rates. (ii) Machinery required for lifting of DG set safety, transportation and re-installation shall be deemed to be included in quoted rates. (iii) No extra cost will be paid by the department in case of any damage and broken parts of DG Sets. (iv) Minor items required for fixing and installation shall be deemed to be included in the quoted rates. (v) Cost of foundation is deemed to be included in unit rate quoted.
96M&L for dismantling and shifting of AMF Panel/ LT Panel with connected UG cables installed at existing location and installed at new location, panel should be monthed on angle iron from and legs (vertical height of legs not less than 30cm except in PCC) made from angle of existing size, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer legs grouted in PCC 1:3:6 type B2 (using 40mm graded stone aggregate) complete including all connections with foundation complete all as specified and directed. Note : Cost of foundation, tool and plant required for dismantling and installation is deemed to be included in quoted rates.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy