Military Engineer Services-MES has published Tender For Repair To Window Type And Split Type Ac Installed At 12 Wing Af Station Chandigarh. Submission Date for this Tender is 22-04-2024. AMC of Air Condition Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

43090977
Corrigendum : Tender For Repair To Window Type And Split Type Ac Installed At 12 Wing Af Station Chandigarh
Open Tender
Indian
Chandigarh
Chandigarh
22-04-2024

Tender Details

Tender For Repair To Window Type And Split Type Ac Installed At 12 Wing Af Station Chandigarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 35320.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO WINDOW TYPE AND SPLIT TYPE AC INSTALLED AT 12 WING AF STN CHANDIGARH
Sl. No. Item Description
1REPAIR TO WINDOW TYPE AIR CONDITIONER 1.5/ 2.0 TON OF ANY MAKE AND TYPE
2Dismantling & taking out unserviceable sealed unit from existing window type AC 1.5 ton capacity, Supply and fixreciprocating/rotary type company new compressor suitable for make Carrier/ Voltas/ Emersion/ Videocon including cleaning of condenser/ cooling coil, charging of compressor oil, testing, including replacement of new bushes, washers, mounting rubbers, nuts & boltscomplete all as specified and directed.
3Dismantling & taking out unserviceable sealed unit from existing window type AC 2 ton capacity, Supply and fixreciprocating/rotary type company new compressor suitable for make Carrier/ Voltas/ Emersion/ Videocon including cleaning of condenser/ cooling coil, charging of compressor oil, testing, including replacement of new bushes, washers, mounting rubbers, nuts & boltscomplete all as specified and directed.
4Dismantling and taking out window type air conditioner of capacity 1.5/ 2.0 Ton of any make/ type from its original location, carrying out maintenance/ overhauling cleaning with vacuum cleaner and greasing,including cleaning of condensers/ cooling coil, cleaning of air filter with caustic soda and water mixture & checking of connections complete servicing replacement of minor unserviceable parts such as rubber bushes, washers, mountingpad, rubbers, nuts & bolts, clips etc. and re-fixing the same aftertesting complete all as specified and directed. Notes: (a) Spare parts (other than minor) including gas shall be measured and paid for separately under respective item of Schedule of Works. (b) The work under this item shall be executed on emergency basis to avoid inconvenience to the users as directed by Engineer-in-Charge. In this connection condition 8 of IAFW-2249 also refers.
5Supply & refilling refrigerant R-22 after testing, rectification of leakage in the system with brazing/ welding complete all as specified and directed
6Supply & fix liquid line strainer in repairs complete all as specified and directed
7Supply & fixing thermostatic switch for air conditioner in repair complete all as specified and directed. Make: Indfoss/ Denfoss.
8Supply & fix PVC condenser fan blade in repair matching with existing type & mode complete all as specified and directed.
9Supply & fix blower drum in repair matching with existing type & model complete all as specified and directed.
10Supply and fix in repair fan motor 1/5 HP single Phase 230 volts complete with base, nuts, bolts & washers to match with existing type and model complete all as specified and directed. Make: AUE/ Cool Home/ Universal/ Crompton.
11Supply & fix in replacement air filter as per existing superior quality (Window type AC 1.5/ 2.0 ton) complete as specified & directed.
12Supply and fix in replacement condenser coil 4-row fins type in repair as per existing type & model complete all as specified & directed.
13Supply and fix in repair wiring kit as per original specifications with bronze thimbles and code marking complete all as specified & directed.
14Supply and fix in repair cooling coil as per existing type and model complete all as specified and directed.
15Supply only electronic type remote control suitable for 1.5 TR window type AC as per existing. Make: LG/ Videocon/ Voltas
16Supply and fix in replacement panel circuit board electronic for split AC 1.5/ 2.0 ton complete all as specified and directed.
17Supply and fix front grill of window type AC of capacity 1.5 Ton complete with knobs, PVC filter etc. all as per sample including taking down old unserviceable grill complete all as specified and directed.
18REPAIRS TO SPLIT TYPE AIR CONDITIONERS 1.5/ 2.0 TR CAPACITY ANY MAKE AND MODEL
19Dismantling and taking out unserviceable sealed unit from existing split type AC 1.5 ton capacity of make LG/ Emulsion Climate/ Tecumseh/ Carrier/ Videocon and supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/ cooling coil, charging of compressor oil, refrigerant as per existing, including replacement of new bushes, washers, mounting rubbers, nuts & bolts and & testing complete all as specified & directed.
20Dismantling & taking out unserviceable sealed unit from existing split type AC 2.0 ton capacity of make LG/ Emulsion Climate/ Tecumseh/ Carrier/ Videocon and supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/ cooling coil, charging of compressor oil, refrigerant R-22 including replacement of new Bushes, washers, mounting rubbers, nuts & bolts and testing complete all as specified & directed.
21Dismantling & taking out split type air conditioner of capacity 2.0/ 1.5 Ton of any make/ type from its original location, carrying out maintenance/ overhauling, greasing after cleaningthoroughly with vacuum cleaner, checking of connections, replacement of minor unserviceable parts such as rubber bushes, washers, mounting rubbers, nuts & bolts, clips etc. and testing, complete all as specified and directed. Note: Spare parts required for replacement shall be measured and paid for separately.
22Supply and fix in repair contactor single phase 230 volts AC 40 Amps coil range 208/ 240 volts complete all as specified and directed. Make: USHA/ SIEMENS/ L&T.
23Supply and fix in repair capacitor 4 MFD, AC 230 volts dry type complete all as specified and directed. Make: EPCOS/ BAJAJ/ USHA/ UNISTON.
24Supply & fix in repairs fan motor 1/8 HP single Phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit of make Carrier complete all as specified and directed.
25Supply & fix in repairs blower motor 1/20 HP single phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit of make Carrier complete all as specified and directed.
26Supply only remote control electronic type suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed. Make: LG/ Videocon/ Voltas.
27Supply and fix in repairs panel circuit board electronic for split AC 1.5/ 2.0 ton complete all as specified and directed.
28Supply and fix in repairs Tee valve of size 5/8? and 3/8? complete all as specified and directed.
29Supply and fix, Tee valve of size 3/8? and 1/4? in replacement complete all as specified and directed
30Supply and fix in replacement wiring kit as per original specification with bronze thimbles and code marking complete all as specified & directed.
31MISCELLANEOUS ITEMS FOR REPAIR TO WINDOW TYPE AND SPLIT TYPE ACS
32Supply and fix in repairs running capacitor 36 MFD, AC 230 volts grade complete all as specified and directed. Make: EPCOS/ USHA/ UNISTAR/ SIEMENS.
33Supply and fix in repairs running capacitor 45 MFD, AC 230 volts grade complete all as specified and directed. Make: EPCOS/ USHA/ UNISTAR/ SIEMENS.
34Supply and fix in repairs starting capacitor 100-120MFD complete all as specified and directed. Make: KELTRON/ TESLA/ SIEMENS/ SPEED.
35Supply and fix in repairs starting relay box type (suitable for off sizes split type ACs) complete all as specified and directed. Make: SHRIRAM/ RENUTROL/ HI-TECH.
36Supply and fix in repairs copper tubing size 5/8? including gas welding and making leak proof complete all as specified and directed.
37Supply and fix in repairs copper tubing size 3/8? including gas welding and making leak proof complete all as specified and directed
38Material and labour for black foam 4mm thick and 50mm wide for insulation, suction and discharge line complete all as specified and directed.
39Supply and fix in repairs thermostatic switch of split type air conditioner 1.5/ 2.0 TR complete all as specified and directed. Make: Indfoss/ Denfoss.
40Supply and fix in repairs metal plug top 15 Amps, 3 pin 230 volts grade complete all as specified and directed. Make: Anchor/ SSK/ Kalinga/ Havells.
41S&F sheet metal enclosure single pole and neutral with 2 pin and earth plug and socket complete with 1 No. single pole 20 Amps 240 volts MCB complete including necessary fixing arrangement and connecting all incoming and outgoing electric connection complete all as specified as directed. Make: INDOASIAN/ HAVELLS/ HPL/ POLICAB/ STANDARD/ ANCHOR BY PANASONIC.
42Attending complaints of non functional air conditioner of any make/ model/ type and making them serviceable within 48 Hrs after taking the complaint from the office complete all as specified and directed. Note: Items/ spare parts required to attend the complaint shall be measured and paid for separately under respective item.
43Supply & refilling refrigerant R-132, R-134 after testing and rectification of leakage in the system with brazing/ welding complete all as specified and directed.
44REPAIRS TO VOLTAGE STABILIZERS ANY MAKE AND MODEL
45Taking down unserviceable/ burnt voltage stabilizer of capacity 5KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed.
46Taking down unserviceable/ burnt voltage stabilizer of capacity 4KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed.