Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-04-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-04-2024 |
| 2 | 09-04-2024 | Revised BOQ | BOQ | 20-04-2024 |
| 3 | 09-04-2024 | Date Corrigendum | Date | 20-04-2024 |
| Sl. No. | Item Description |
| 1 | M&L for dismantling of centrifugal/ submersible pump motor of capacity 7.5 to 10 HP, 3 Phase, 415 volts, vertical or horizontal any type, including taking down from foundation/ base frame by disconnecting suction/ delivery line & coupling, opening, required grinding, welding, machining, lathing alignment, grasing, etc andreplacement of worn out spare parts& cable connections, re-assembling of pump set, re-installation & re-commissioning at its original location & testing complete all as specified and as directed.Note : Unserviceable parts required for replacement shall be measured & paid separately as \"Supply only\" under here-in-after.Note:- Crane for taking up & lowering of submersible motor & submersible pump set while repairing/rewinding will be arranged by the contractor and the rent for the same is included in the item rate. |
| 2 | Supply only following spare parts for submersible pump of capacity 10 HP for replacement under serial item No. 1.00 here-in-before as per existing make, complete all as specified & as directed. Note :- Spare Parts shall be of size, type & make as used / recommended by the Original Equipment Manufacturer (OEM). |
| 3 | GM Bush |
| 4 | Rotor sleeve |
| 5 | Water seal |
| 6 | Thrust bearing |
| 7 | Thrust plate |
| 8 | Coupling Stainless Steel |
| 9 | Key for coupling |
| 10 | Seal bush |
| 11 | Supply only following spare parts for centrifugal pump of capacity 7.5 HP for replacement under serial item No. 1.00 here-in-before as per existing make, complete all as specified & as directed. Note :- Spare Parts shall be of size, type & make as used / recommended by the Original Equipment Manufacturer (OEM). |
| 12 | Gland Bush |
| 13 | Gland Cap CI with nut bolt |
| 14 | Ball bearing for 7.5 HP.Make - SKF. NBC. |
| 15 | Shaft sleeve Bronze |
| 16 | Shaft sleeve nut bronze |
| 17 | Set of gasket |
| 18 | Bearing housing DE |
| 19 | Bearing housing NDE |
| 20 | Cast iron Impellor |
| 21 | Flexible Tyres cupling |
| 22 | Motor terminal plate |
| 23 | M&L for dismantling of centrifugal/submersible pump motor of capacity 1.0 to 5 HP, 3 Phase, 415 volts, vertical or horizontal any type, including taking down from foundation/ base frame by disconnecting suction/ delivery line & coupling, opening, required grinding, welding, machining, lathing alignment, grasing, etc andreplacement of worn out spare parts& cable connections, re-assembling of pump set, re-installation & recommissioning at its original location & testing complete all as specified and as directed.Note : Unserviceable parts required for replacement shall be measured & paid separately as \"Supply only\" under here-in-after.Note:- Crane for taking up & lowering of submersible motor & submersible pump set while repairing/rewinding will be arranged by the contractor and the rent for the same is included in the item rate. |
| 24 | Supply only following spare parts for submersible pump of capacity 5 HP for replacement under serial item No. 4.00 here-in-before as per existing make, complete all as specified & as directed. Note :- Spare Parts shall be of size, type & make as used / recommended by the Original Equipment Manufacturer (OEM). |
| 25 | S/S Impeller. |
| 26 | S/S Pump shaft (single stage) |
| 27 | Hook bolt (Upper & lower) |
| 28 | S/S neck ring |
| 29 | Key for pump shaft (Each stage) |
| 30 | Distance sleeve |
| 31 | Suction chamber |
| 32 | M&L for opening of submersible motor of capacity 10 HP, 3 Phase, 415 volts, vertical or horizontal any type, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with new solid copper conductor (winding wire) of sixze as used by manufacturer / existing size, complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire: CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEENote : Rate including required tools and Transportation Charges. |
| 33 | M&L for opening of submersible motor of capacity 7.5 HP, 3 Phase, 415 volts, vertical or horizontal any type, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with new solid copper conductor (winding wire) of sixze as used by manufacturer / existing size, complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire: CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEENote : Rate including required tools and Transportation Charges. |
| 34 | Supply only the following spare parts for submersible motor of capacity 7.5 HP to 10 HP against serial item No. 6.00 to 7.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the motor only after prior inspection & approval of AGE E/M. |
| 35 | Bearing with Existing size |
| 36 | Rotor sleeve |
| 37 | Water seal(KSB only) |
| 38 | Cable seal |
| 39 | M&L for opening of submersible motor of capacity 1 HP to 5 HP, 3 Phase, 415 volts, vertical or horizontal any type, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with new solid copper conductor (winding wire) of sixze as used by manufacturer / existing size, complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire: CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEENote : Rate including required tools and Transportation Charges. |
| 40 | Supply only the following spare parts for submersible motor of capacity 1.0 HP to 5 HP against serial item No. 9.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE E/M. |
| 41 | Bearing with Existing size |
| 42 | Rotor sleeve |
| 43 | Water seal(KSB only) |
| 44 | Cable seal |
| 45 | M&L for taking down defective induction motor of capacity 1.0 HP to 5 HP, 03 Phase, 415 Volt, 50 Hz from the foundation, disconnecting the electric connections, coupling pully and transporting to workshop for repair, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with new solid copper conductor (winding wire) as existing size and gause complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire: CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEE |
| 46 | M&L for galvanized steel water tubing medium grade of 150mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 150mm bore complete all as specified and as directed. |
| 47 | M&L for galvanized steel water tubing medium grade of 100mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 100mm bore complete all as specified and as directed. |
| 48 | M&L for galvanized steel water tubing medium grade of 80mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 80mm bore complete all as specified and as directed. |
| 49 | M&L for galvanized steel water tubing medium grade of 65mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 65mm bore complete all as specified and as directed. |
| 50 | M&L for galvanized steel water tubing medium grade of 50mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 50mm bore complete all as specified and as directed. |
| 51 | M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 40mm bore complete all as specified and as directed. |
| 52 | M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 25mm bore complete all as specified and as directed. |
| 53 | M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings,laid in trenches, including taking up or down unserviceable steel water tubing and connections of 20mm bore complete all as specified and as directed. |
| 54 | S&F 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 20mm bore, complete, all as specified & directed. |
| 55 | S&F 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 25mm bore, complete, all as specified & directed. |
| 56 | S&F 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 50mm bore, complete, all as specified & directed. |
| 57 | Supply and fixing in replacement of Hydrocyclone filter with 2 solid flange size of 75mm dia and capacity of 30 m³/hour for head control unit in drip irrigation system IS 14743:1999 with all connected accessories complete all as specified and directed.Make :- Sourabh shaktiman |
| 58 | Supply and fixingin replacementof mild steel disc filter with 2 solid flange size of 90mm dia and capacity of 30 m³/hour for head control unit in drip irrigation system IS 14743:1999 with all connected accessories complete all as specified and directed. Make :- Sourabh shaktiman |
| 59 | Supply and fixingin replacementof mild steel disc filter with 2 solid flange size of 75mm dia and capacity of 30 m³/hour for head control unit in drip irrigation system IS 14743:1999 with all connected accessories complete all as specified and directed. Make :- Sourabh shaktiman |
| 60 | Supply and fixingin replacementof mild steel disc filter with 2 solid flange size of 50mm dia and capacity of 30 m³/hour for head control unit in drip irrigation system IS 14743:1999 with all connected accessories complete all as specified and directed. Make :- Sourabh shaktiman |
| 61 | Supply and fixing in replacement of PP manifold of size 75mm for Filter Unit of Drip and Pop-up system with connected accessories all complete as specified and directed. |
| 62 | Supply and fixingin replacement of Ventury with Ferttigation Manifold assemble size of 50 to 75mm for head control unit IS : 14483:1997 with all acessories complete all as specified and directed. Brand : Saurabh Shaktiman |
| 63 | Supply and fixingin replacement of Air relese valve (PVC) size of 50mm dia for head control unit in dirip irrigation system complete all as specified and directed. |
| 64 | Supply and fixingin replacement of pressure relese valve (PVC) size of 50mm dia for head control unit in dirip irrigation system complete all as specified and directed. |
| 65 | Supply and fixing in replacement of pressure gauge (glycerine) capacity of 0-7 kg/cm² size of 63mm dia for head control unit in dirip irrigation system complete all as specified and directed. |
| 66 | Supply and fixing in replacement of screen filter (plastic) with 2 solid flange size of 75 mm dia and capacity of 30 m³/hr for head control unit in drip irrigation system IS : 12785:1994complete complete all as specified and directed. Brand - Saurabh Shaktiman |
| 67 | Supply and fixing in replacement of PP control valve size of 75mm for controlling water in storage tank for drip irrigation system complete all as per directed. |
| 68 | Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer) conceal ed pipes SDR 7.4 (PN16)IS : 15801 UV stabilized and antimi crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches size of 90mm dia for main distribution line in drip irrigation system and including all connected accessories .(ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent,clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/Kisan/Tirupati/Kanha Plastics Pvt Ltd (Brand - KPT)/ Supreme/ SFMC (Savour Fair Manufacturing Co Pvt Ltd). |
| 69 | Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer) conceal ed pipes SDR 7.4 (PN16)IS : 15801 UV stabilized and antimi crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches size of 75mm dia for main distribution line in drip irrigation system and including all connected accessories .(ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent,clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/Kisan/Tirupati/Kanha Plastics Pvt Ltd (Brand - KPT)/ Supreme/ SFMC (Savour Fair Manufacturing Co Pvt Ltd). |
| 70 | Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer) conceal ed pipes SDR 7.4 (PN16)IS : 15801 UV stabilized and antimi crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches size of 63mm dia for main distribution line in drip irrigation system and including all connected accessories .(ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent,clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/Kisan/Tirupati/Kanha Plastics Pvt Ltd (Brand - KPT)/ Supreme/ SFMC (Savour Fair Manufacturing Co Pvt Ltd). |
| 71 | Supply and fixing in replacement of PVC pipe (6 Kg/cm²) IS ; 4985:2000 size of 90mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent, clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/kisan/Tirupati or eaquivalent. |
| 72 | Supply and fixing in replacement of PVC pipe (6 Kg/cm²) IS ; 4985:2000 size of 75mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent, clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/Kisan/Tirupati or eaquivalent. |
| 73 | Supply and fixing in replacement of PVC pipe (6 Kg/cm²) IS ; 4985:2000 size of 63mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent, clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/Kisan/Tirupati or eaquivalent. |
| 74 | Supply and fixing in replacement of PVC pipe (6 Kg/cm²) IS ; 4985:2000 size of 50mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket, Bend, Elbow, Tee, Reducer, connector, Solvent, clamps etc) complete all as specified and directed. Make :- Finolex/supreme/Prince/Kisan/Tirupati or eaquivalent. |
| 75 | Supply and fixing in replacement of Plain lateral 2.5 kg/cm², class II size of 32mm dia, for water distribution line in dirip irrigation system and including all connected accessories (ie Socket, Bend, Elbow,Tee, Reducer, connector, suitable size Grommat Joiner 16mm take off, End cap, etc) complete all as specified and directed. (For Trees)Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 76 | Supply and fixing in replacement of Plain lateral 2.5 kg/cm², class II size of 16mm dia, online for water distribution line in drip irrigation system including all connected accessories (i.e Grommat, Lateral cock, End cap for connection in UPVC/Plain lateral pipe etc) (For trees) complete all as specified and directed. (For Tree) Make :- Finolex/supreme/Prince/Kisan/Tirupati or eaquivalent. |
| 77 | Supply and fixing in replacement of Emitting pipe of dia 16mm, discharge 2 LPH, dripper spacing 30cm, 2,5 kg/cm², IS:13488, including all connected accessories (ie Socket, Bend, Elbow, Tee,connector, suitable size Grommat, Joiner etc.(for hedge) complete all as specified and directed. (For Hedges) Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 78 | Supply and fixing in replacement of PVC Control valve size of 75x63mm dia for head control unitsub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent |
| 79 | Supply and fixing in replacement of PVC Control valve size of 63x32mm dia for head control unitsub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent |
| 80 | Supply and fixing in replacement of PVC Control valve size of 75mm dia for head control unitsub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed.Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent |
| 81 | Supply and fixing in replacement of PVC Control valve size of 63mm dia for head control unitsub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed.Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent |
| 82 | Supply and fixing in replacement of PVC Control valve size of 32mm dia for head control unitsub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent |
| 83 | Supply and fixing in replacement of PPR/PVC Control valve size of 90mm dia for head control unitsub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed.Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent |
| 84 | Supply and fixing in replacement of Flush valve size of 75x63mm dia for sub distribution line in dirip irrigation system complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 85 | Supply and fixing in replacement of service saddle of 75x32mm dia including MT and FT for water distribution line in dirip irrigation system complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 86 | Supply and fixing in replacement of service saddle of 63x32mm dia including MT and FT for water distribution line in dirip irrigation system complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 87 | Supply and fixing in replacement of push type male threaded adopter size of 32mm dia for water distribution line in dirip irrigation system complete all as specified and directed. (For Hedges)Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 88 | Supply and fixing in replacement of PP control valve (Th. End) size of 32mm dia for sub distribution line in dirip irrigation system complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 89 | Supply and fixing in replacement of Dripper cap 8 LPH for dirip irrigation system and connected accessories complete all as specified and directed. Make :- Finolex/supreme/ Prince/Kisan/Tirupati or eaquivalent. |
| 90 | Supply and fixing in replacement of Pop-Up Impact sprinkler of heavy duty Plastic, adjustable to full-circle or Part circle with diffuser screw for fine drop lets and throw control, inlet size 3/4\", having radious of throw up to 12 mtrs at pressure 4 Kg/cm² omplete all as specified and directed. Make Aquaturf. |
| 91 | Supply and fixing in replacement of Swing joint full three way adjustability including neight for Pop-Up Impact Sprinkler, bush with connected accessories, durable polyethylene construction for 3/4\" size complete all as specified and directed. Make Aquaturf |
| 92 | Supply and fixing in replacement of PVC End cap size of 63mm dia for water distribution line in Pop-Up irrigation system and all including complete accessories complete all as specified and directed. |
| 93 | Supply and fixing in replacement of Robust top cover with nonslippery grip Plastic heavy duty extended bottom keeps the valve box stable and firmly set in the soil with Green Topand black base Size 10\" rectangular shape at Pop-up distribution line and including all connected accessories complete all as specified and directed. |
| 94 | S&F in replacement of Foam jet fountain Nozzle of gun metal chromium plated of size inner dia 38mm upper dia 35mm & height 150mm, fixed in repairs, complete all as specified and as directed.Make : Aquascape / Royal / Creative / Novatech or other equivalent make as approved by GE. |
| 95 | Supply and fixing in replacement of Geyser Jet fountain Nozzle of gun metal chromium plated of size inner dia 50mm, outer dia 78mm & height 150mm, fixed in repairs, complete all as specified and as directed.Make : Aquascape / Royal / Creative / Novatech or other equivalent make as approved by GE. |
| 96 | Supply and fixing in replacement of Geyser Jet fountain Nozzle of gun metal chromium plated of size inner dia 65mm, outer dia 150mm & height 225mm, fixed in repairs, complete all as specified and as directed. Make : Aquascape / Royal / Creative / Novatech or other equivalent make as approved by GE. |
| 97 | Supply and fixing in replacement of Angular valve of gun metal chromium plated of size inner dia 20mm, outer dia 25mm, height 65mm or (as per Exiting size), fixed in repairs, complete all as specified and as directed.Make : Aquascape / Royal / Creative / Novatech or other equivalent make as approved by GE. |
| 98 | Supply and fixing in replacement of Geyser Jet fountain Nozzle of Brass of size inner dia 25 mm, outer dia 150 mm & height 225mm, fixed in repairs, complete all as specified and as directed. Make : Aquascape / Royal / Creative / Novatech or other equivalent make as approved by GE. |
| 99 | Supply and fixing in replacement of LED base water proof programmable colour changing lights as per site requirement, Number of LED-96 Nos, gun metal ring with chromium plated/aluminum powder coated housing for operative voltage - 18 Volt DC, 6Watt / 9Watt, Colour - RGB, colour programmable, size 200mm dia and 30mm height minimum including necessary electrical work, fixed, complete all as specified & as directed.Make : Model 06R/108R, FM-5MM BODY-ABS/PVC of Creative or equivalent in Philips / Bajaj / Crompton Greaves / Raj / Aroma / Aquascape / Royal / Novatech or other equivalent make as approved by GE. Notes:- (i) All LED light/luminare shall meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II / Section 13.(ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80.(iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :-(a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. |
| 100 | Supply and fixing in replacement and testing micro processing DMX controller for changing colour of colour changing lights changing fast slow or fading of colour with operating voltage 18 Volt DC, 5 Amps as per site requirement, fixed in repairs, complete all as specified and as directed.Make : Creative / Aroma / Aquascape / Royal /Novatech or other equivalent make as approved by GE. |
| 101 | Supply and fixing in replacement of submersible flat cable of size 10 sqmm, 3 Core, multistranded copper conductor, PVC insulated and sheathed copper screen protected, 1100 Volts grade, fixed in repairs, complete all as specified and as directed. |
| 102 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 103 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 104 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 105 | Supply, laying, jointing and testing LT XLPE insulated screened,bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 6 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 106 | M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed.Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.(ii) For the purpose of payment, only punned thickness shall be measured. |
| 107 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed. |
| 108 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 109 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 110 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. |
| 111 | Supply and fixing in replacement of MCCB, 4 Pole, 40 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed. |
| 112 | Supply and fixing in replacement of MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed. |
| 113 | Supply and fixing in replacement of MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed. |
| 114 | Supply and fixing in replacement of MCCB, 4 Pole, 160 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed. |
| 115 | Supply and fixing in replacement of mild steel clamps made of flat iron 40x6mm in two halves for tapping through 100mm bore GI/CI/DI water pipe line including made to shape, drilling and welding of 25mm GI socket and necessary rubber insertion, nut, bolts & washers complete all as specified and as directed. |
| 116 | S&F in replacement of Star delta starter 7.5 to10 HP Sumbersible/centrifugal pump set as per existing capacity and features complete all as specified and as directed. |
| 117 | S&F in replacement of Star delta starter 1 to 5 HP Sumbersible/centrifugal pump set as per existing capacity and features complete all as specified and as directed. |
| 118 | S&F in replacement of MS/GI pipe heavy duty for pumping set section line discharge water line including with necessary fitting cutting thrding welding etc and replacement of worn outMS net bots washer & sockets Flange etc 100mm bore heavy duty class \"C\"including complete painting with two coat of paint over complete all as specified and as directed by Engineer-in-Charge. |
| 119 | S&F in replacement of MS/GI pipe heavy duty for pumping set section line discharge water line including with necessary fitting cutting thrding welding etc and replacement of worn outMS net bots washer & sockets Flange etc 80mm bore heavy duty class \"C\"including complete painting with two coat of paint over complete all as specified and as directed by Engineer-in-Charge. |
| 120 | Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT Panel board (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 2mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 40mmx40mmx5mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiringwith PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following:- |
| 121 | Description of serial item No. 86.00 Contd…(a) MCCB, 4 Pole, 100 Amps, rupturing capacity 36 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic release - 01 No. (Incoming).(b) MCCB, 4 Pole, 63 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic release - 05 Nos (Outgoing).(c)MCB 63 Amp rating, SPN, rupturing capacity 10 kA, ‘C’ Series - 02 No (Outgoing)(d) Digital Volt meter, Digital Amp meter with built in selector switch including necessary CTs (set of three) - 1 Set.(e) Neon Indicator lamps Set RYB, “LED” type (set of three) - 03 Set(f) Fully automatic Star delta starter with no voltage release single phase preventer, short circuit and earth fault release suitable for motot capacity 10HP(g) Suitable place for fixing of micro processing DMX controller. |
| 122 | Notes for serial item No. 86.00 Contd :- (i)Vertical height of legs of LT panel base frame shall be not less than 45cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from AGE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of AGE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.(vi) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box.(vii) Rates quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. |
| 123 | Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT Panel board (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiringwith PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following:- (a) MCCB, 4 Pole, 40 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal - Magnetic setting - 01 No. (Incoming).(b) MCCB, 3 Pole, 25 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal - Magnetic setting - 03 Nos (Outgoing).(c) Digital Volt meter 0.500 volts with selector switch - 1 No.(d) Digital Amp meter 0-50 Amp with selector switch - 2 Nos.(e)Neon Indicator lamps Set RYB, “LED” type (set of three) - 03 Set |
| 124 | Notes for serial item No. 87.00 Contd :- (i)Vertical height of legs of LT panel base frame shall be not less than 45cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from AGE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of AGE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.(vi) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box.(vii) Rates quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. |
| 125 | Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder Pillar box (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars 100 Amp rating in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiringwith PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following:- (For Fountain) |
| 126 | Description of serial item No. 88.00 Contd…(a) MCCB, 4 Pole, 40 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic setting - 01 No. (Incoming).(b) MCCB, 3 Pole, 25 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic setting - 02 Nos (Outgoing). (For 7.5 HP Pump)(c)MCCB, 3 Pole, 16 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic setting - 02 Nos (Outgoing). (For 5 HP Pump)(d) Digital Volt meter 0.500 volts with selector switch - 1 No.(e) Digital Amp meter 0-50 Amp with selector switch - 2 Nos.(f)Neon Indicator lamps Set RYB, “LED” type (set of three) - 03 Set(g)Single phase preventer suitable for 5 HP/7.5 HP submersible pump set each.(h)DOL Motor starter in sheet steel enclosure, suitable for 7.5 HP electric Motor, 3 phase, 415 volt, 50 Hz – 01 No.(j)DOL Motor starter in sheet steel enclosure, suitable for 5 HP electric Motor, 3 phase, 415 volt, 50 Hz – 01 No. (k) Space for fixing of DMX Controller with 18 Volt transformer for changing colour of lights microprocessing controller - 02 Nos. |
| 127 | Notes for serial item No. 88.00 Contd :- (i)Vertical height of legs of LT panel base frame shall be not less than 45cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from AGE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of AGE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.(vi) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box.(vii) Rates quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. |
| 128 | Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder Pillar box (KIOSK), outdoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars 100 Amp rating in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiringwith PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following:- (a) MCCB, 4 Pole, 25 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic setting - 01 No. (Incoming).(b) MCCB, 3 Pole, 16 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, Thermal Magnetic setting - 03 Nos (Outgoing). (c) Digital Volt meter 0.500 volts with selector switch - 1 No.(d) Digital Amp meter 0-50 Amp with selector switch - 2 Nos.(e)Neon Indicator lamps Set RYB, “LED” type (set of three) - 03 Set |
| 129 | Notes for serial item No. 89.00 Contd :- (i)Vertical height of legs of LT panel base frame shall be not less than 45cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from AGE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of AGE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.(vi) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box.(vii) Rates quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. |
| 130 | Disconnecting & taking down the existing unserviceable HDPE water tank and Supply and fixing 2000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. |
| 131 | Supply and fixing in replacement of cast iron body Foot valve heavy duty class ‘PN-1.6’ of 25 to 80mm bore, ISI marked with IS 14846, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 100mm bore, complete all as specified & directed. |
| 132 | Cleaning and repair of sump of arboriculter upto capacity 10,000 Gallons (01 Gallon = 4.54 litre) by desludging/ scraping the bottom, sides, upper bottom and walls (Internal) with the help of scrapper/wire iron brush, removing all scale, dirt/mud, caked earth, slit and deposited materials including other foreign deposited materials including dewatering the left over water and taking them out complete and painting ofone coat by liquidbleaching powder all as directed. |
| 133 | Supply and fix in replacement of Emitters or drippers for irrigaion system for single plant with connected accessories all complete as specified and directed. |
| 134 | M&L for Earthing to equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 25x4mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 5 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50mincluding dismantling & taking out old existing unserviceable earthing complete all as specified and as directed.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail