Tender For Repair/Main Of Internal Elect Flame Proof Lights, High Bay Lights, At Technical Area Repair/ Maint Of Security Lights And Garden Lights, Solar Lights Tanaji, Ayudh Vihar, Nsb Nofra Under Ge (Nw) Mankhurd, mankhurd-Maharashtra

Military Engineer Services-MES has published Tender For Repair/Main Of Internal Elect Flame Proof Lights, High Bay Lights, At Technical Area Repair/ Maint Of Security Lights And Garden Lights, Solar Lights Tanaji, Ayudh Vihar, Nsb Nofra Under Ge (Nw) Mankhurd. Submission Date for this Tender is 30-04-2024. Tube Light Tenders in mankhurd Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43085476
Corrigendum : Tender For Repair/Main Of Internal Elect Flame Proof Lights, High Bay Lights, At Technical Area Repair/ Maint Of Security Lights And Garden Lights, Solar Lights Tanaji, Ayudh Vihar, Nsb Nofra Under Ge (Nw) Mankhurd
Open Tender
Indian
Maharashtra
mankhurd
30-04-2024

Tender Details

Repair/Main Of Internal Elect Flame Proof Lights, High Bay Lights, At Technical Area Repair/ Maint Of Security Lights And Garden Lights, Solar Lights Tanaji, Ayudh Vihar, Nsb Nofra Under Ge (Nw) Mankhurd

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Apr-2024 AMENDMENT Other 23-04-2024
2 23-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-04-2024
3 29-Apr-2024 ADDITION OF MAKES Other 30-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING FITTINGS & FIXTURES, FLAME PROOF LIGHTS, HIGH BAY LIGHTS, LIGHTNING PROTECTION AT TECHNICAL AREA AT MANKHURD. REPAIR/ MAINTENANCE OF SECURITY LIGHTS AND GARDEN LIGHTS, SOLAR LIGHTS AT CIVILIAN DEFENCE COLONY TANAJI AYUDH VIHAR, NSB NOFRA INCLUDING REPAIR/ MAINTENANCE OF DEFECTIVE AND BURNOUT LIGHTING ARRESTERS LIGHTING CONDUCTORS AND EARTHING OF BUILDING UNDER GE (NW) MANKHURD
Sl. No. Item Description
1M & L forpoint wiring with PVCinsulated unsheathed 1100 Volts grade single core FRLS multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories andearth continuity FRLS multistranded copper conductorcable size connected to common earth and earth dolly including 2 mm thick pressedsteel terminal boxes concealed in wall covered withlaminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screws including taking down u/s wiring, fittings, switch, sockets etc all as specified for the following: Note:- All points to be made in Hangers/Sheds, hight up to 10 Meters only. (a)For one light, fan, call bell, point controlled by one switch.
2(b)For one socket point controlled by one switch on same board
3(c)For one5 Amp independent socket point controlled by one switch.
4All as per item No 1 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi stranded 1100 volt grade cable as continuous earth lead.
5M&L circuit wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5sqmm drawn in MS Steel conduitwith 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable wiring complete. Note : 1. M S Conduit/ PVC Conduitwill be measured and paid separately. 2. wiring in shed upto height of 6 mtr. 3. Three run of 1,5 Sqmm wire will be measured & paid as one unit. Make: Apar/ Polycab/ KEI
6M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5sqmm drawn in MS Steel conduitwith 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduitwill be measured and paid separately. 2.wiring in shed upto height of 6 mtr.3. Three run of 2.5 Sqmm wire will be measured & paid as one unit. Make: Apar/ Polycab/ KEI
7M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4Sqmm drawn in MS Steel conduitwith 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete.Note : 1. M S Conduitwill be measured and paid separately. 2.wiring in shed upto height of 6 mtr.3. Three run of 4 Sqmm wire will be measured & paid as one unit. Make: Apar/ Polycab/ KEI
8S&F in repairs rigidmetallic medium20 mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position all as directed by Engineer-in-Charge.
9M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5sqmm drawn in Existing surface/recessed MS Steel conduit/PVC Conduitwith 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduitwill be measured and paid separately if required on ground. 2.wiring in shed upto height of 6 mtr.3. Three run of 1,5 Sqmm wire will be measured & paid as one unit. Make: Apar/ Polycab/ KEI
10M&L sub main wiring in repais with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5sqmm drawn in Existing surface/recessed MS Steel conduit/PVC Conduitwith 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. Additional M S Conduit/ PVC Conduitwill be measured and paid separately if required . 2.wiring in shed upto height of 6 mtr.3. Three run of 2.5 Sqmm wire will be measured & paid as one unit. Make: Apar/ Polycab/ KEI
11M & L for Opening switch mounting plate, rectifying the defects in fittings and fixtures by tightening loose connections or taking down of unserviceable/burnt Piano Switches, fan regulators, 5 Amps Sockets, 15 Amps Sockets, 5 Amps Switch socket Commbination, 15 Amps Switch Socket combination, Fan Regulators. Note :- (i) The representative of the contrcator (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No) shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period (ii) Replacement of defective parts/items will be measured and paid as supply and fix under respective items herein below. (iii) The work shall be executed in buildings of Bureau of Sailors, INS Tanaji, NAD Depot, WED & Saw mill.
12M & L for taking down of Light fittings such as 1 X 40 W, 1 X 20, 1x10 Watts tube light fittings, CFL light/LED fittings for repairs & refixing the same after carrying out repairs . Note :- (i) The representative of the contrcator (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period (ii) Tube Rod, CFL lamps, Choke & Starter required to be replaced shall be paid under respective item of this schedule as Supply & fixing. (iii) Minor spares such as holders, connectors, wires are deemed to be inclusive of the quoted rate. (iv) The work shall be executed in buildings of Bureau of Sailors, INS Tanaji, NAD Depot, WED & Saw mill.
13M & L for opening ofMCB DB /MCCB DB front door & replacing of burnt wires & tesing comple after carrying out repairs . Note :- (i) The representative of the Contractor (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period (ii) MCCB & MCB required to be replaced shall be paid under respective item of this schedule as Supply & fixing. (iii) Minor spares such as connectors, wires, lugs are deemed to be inclusive of the quoted rate. (iii) The work shall be executed in buildings of Bureau of Sailors, INS Tanaji, NAD Depot, WED & Saw mill.
14M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of damaged cable Glands, burnt cable lugs, bus bar link, connectors, damaged insulators, burnt copper cables, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed by Engg-in Charge
15Supply & Fix in repairs switch piano single poleflush type 5A,240 V one way complete.
16Supply & Fix in repairs Bell push flush type 5 amp, 250 Volts complete.
17Supply & Fix in repairs switch socket combination 2 in 1 ,5Amps multipurpose flush type complete
18Supply & Fix in repairs switch socket combination 2 in 1,3 pin, 5 and 15 Amps flush type universal.
19Supply & Fix in repairs Ceiling rose surface bakelite three terminal, 240 V complete.
20S&F,in replacement, electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete conforming/ ISI Marked all as specified.
21Supply and fix in repairs bell ding dong AC 230 V single pole.
22S & F in repairs Modular Socket 6 A, 2/3 Pin Combined,inclusive of modular cover plate & box as per combination of pointsMake - Anchor/ Roma/ Havells
23S& F in repairs Modular Socket 6/16 A, 2/3 Pin Combined inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells
24S & F in repairs Modular Switch single pole 1 Way 6 Amps inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells
25S & F in repairs Modular Switch single pole 1 Way 16 Amps inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells
26S&F in repairs ULTRON LED polycarbonate T8 tube 20 Watt with in built driver with metal heat sink, Single/ double sided connection, 230 volts including fixing arrangements and taking down old unserviceable tube rod complete all specified and directed. Make-:Crompton / Havells /Bajaj/Jaquar/Wipro
27S&F in Repairs/ReplacementSurface and wall mounted batten suitable for LED tube 20-22 watts, 230 volts,including fixing mounting blocks 2 Nos, 1.5 sqmm 3 core PVC insulated copper conductor cable including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro
28Supply and fix in repairs decorative recessed type LED light fitting 35/36 watt (size 2"x2") 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro
29Supply & fix in repairs recess & surface LED 1 ft x 4 ft panel ceiling light fitting 40 Watt (SPAN) with high brightness SMD LED as light source and including driver unit, including provision of 3 core copper flexible cable size 1.5 Sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro
30Supply & fix in repairs LED Highbay light fittings 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro Note : Fittings shall will be installed in Hangers/Sheds, height up to 10 Meters only and directed by Engr-in-Charge.
31Supply & fix in repairs very high efficiency round LED Highbay light fittings 150 Watt in PDC housing, IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro Note : Fittings shall will be installed in Hangers/Sheds, hight up to 10 Meters only and directed by Engr-in-Charge.
32S&F in repair of building Security lightfitting made up of pressure die cast alluminium body with mid power 60 Watt LED(PINNACLE PLUS) as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make-:Crompton /Bajaj/Jaquar/Wipro
33M & L in repairs for GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 40mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
34Supply & Fix in repairs MCCB DB TPN 4 Way double door prewired suitable for Triple Pole 125 A incomer MCCBwith the following acessories including taking down u/s DB - a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link Make -Indoasaian/Legrand/ABB/Schnider
35Supply & Fix in repairs MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Indoasaian/Legrand/ABB/Schnider
36Supply & Fix in repairs MCB DB SPN 4 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Indoasaian/Legrand/ABB/Schnider
37Supply & Fix in repairs MCB DB SPN 8 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Indoasaian/Legrand/ABB/Schnider
38Supply & Fix in repairs MCB DB SPN 12 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Indoasaian/Legrand/ABB/Schnider
39Supply & Fix in repairs TPN DB 4 way 415 volts Double door, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Indoasaian/Legrand/ABB/Schnider
40S&F in repairs single pole and neutral enclosure with a two pin and earthand metal cladplug socket complete with one single pole MCB 20 Amp 240 Volts including taking down old u/s complete all as specified and directed. Make - Indoasain/Legrand/L&T
41M&L in repairs for MCB SP, 240 volt, 5 to 32 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ ABB/Schnider/L&T
42M&L in repairs for MCB SPN, 240 volt, 40 to 63 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ABB/Schnider/L&T
43M&L in repairs for MCB TPN, 240 volt, 40 to 100 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ABB/Schnider/L&T
44S&F in repairs GI strip size 25 x 4 mmall as directed including welding brazing and taking down of old copper strips as required at site
45Taking down old unserviceable High bay, Mid Bay, Flame Proof light fittings from walls/Builings/Sheds/Ceilingheight up to 10 Meter for repairs and replacement ofburnt/worn out accessories and refixing the same in existing position including testing of fittings after repair, testing of connected wiring complete all as directed by Engineer in charge . Note :- (a) T & P, Ladder for any height etc are deemed to be included in the quoted rate. (iii) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contrcat period and the defect shall be rectified on the same day (iii)A penal recovery of Rs 500 Per Day Per Complaint for not attening the compalint will be recovered
46Supply and Fix in repairs CIMFR certified LED flame proof tube light fitting 1 X 16/20 Watts, with driver & LED tube rod, IP 65 protection, including connecting up with three core flexible multi strand copper conductor of size 1.5 Sqmm with flexible metal conduit, including fabrication and fixing of red oxide coated brackets made out of MS angles/MS flat for fixing the fitting up to one meter below permenent ceiling, including anchor fastners, nut bolts, hooks, chain etc including taking down old u/s fitting Make : Crompton/ Shyam Switch Gear /Bajaj / Sudhir Note : (a) Fittings shall will be installed in Hangers/Sheds, hight up to 6 Meters only and directed by Engr-in-Charge.(b) T & P, Ladder for any height etc are deemed to be included in the quoted rate.
47Supply and Fix in repairs CIMFR certified LED flame proof tube light fitting 2 X 16/20 Watts, with driver & LED tube rod, IP 65 protection, including connecting up with three core flexible multi strand copper conductor of 1.5 Sqmm, with flexible metal conduit, including including fabricating red oxide coated brackets made out of MS angles/MS flat for fixing the fitting up to one meter below permenent ceiling, including anchor fastners, nut, bolts, hooks, chain etc including taking down old u/s fitting. The Fitting Shall Conform toMake : Crompton/ Shyam Switch Gear /Bajaj / Sudhir Note : (a) Fittings shall will be installed in Hangers/Sheds, hight up to 6 Meters only and directed by Engr-in-Charge.(b) T & P, Ladder for any height etc are deemed to be included in the quoted rate.
48Supply and Fix in repairs CIMFR certified LED flame proof well glass light fitting 60 watts , with driver & LED, IP 65 protection, including connecting up with three core flexible multi strand copper conductor of 1.5 Sqmm, with flexible metal conduit, including including fabricating red oxide coated brackets made out of MS angles/MS flat for fixing the fitting up to one meter below permenent ceiling, including anchor fastners, nut, bolts, hooks, chainetc including taking down old u/s fitting. The Fitting Shall Conform toMake : Crompton/ Shyam Switch Gear /Bajaj / Sudhir Note : (a) Fittings shall will be installed in Hangers/Sheds, hight up to 6 Meters only and directed by Engr-in-Charge.(b) T & P, Ladder for any height etc are deemed to be included in the quoted rate.
49S&F in repairs flame proof WP rotory type, 10/16A, single pole 250V switch with cable termination box in LM6. Make : Shyam switch gear/Sudhir
50S&Fix in replacement Flameproof wall mounted outdoor type double door LT Panel made out of 3 mm thick CRCA Sheet, the panel shall be provided with flame proof MCB DB made out of Cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade, with 1 No cable entry for incoming cable and three Nos cable entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 3 Nos MCB SP6 Amps for out going connections IP 65 protection as per IS 2147/1962. The panel shall be powder coated, front openable and locakable with key and shall be fabricated from CPRI approved sample manufacturer including taking down old u/s Panel complete all as specified and directed. Make- Sudhir /Flexpro /Baliga /crompton greeves/ Shyam Switch Gear Note - The contractor shall submit the Layout Drawing of Panel and got approved by GE before the panel fabrication
51Supply & fix in repairs UPVC panel trunking of size 25 mm X 25mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 2525 or Equivalent from Presto Plast/Finolex
52Supply & fix in repairs UPVC panel trunking of size 45 mm X 45mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 4545or Equivalent from Presto Plast/Finolex
53Supply & fix in repairs UPVC panel trunking of size 100 mm X 100mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 100100or Equivalent from Presto Plast/Finolex
54Supply & fix in repairs UPVC panel trunking of size 300 mm X 100mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 100100or Equivalent from Presto Plast/Finolex
55M & L For Taking down of LT XLPEinsulated, armoured heavy duty 1100 volt grade electric cable with aluminium conductorof size 2 Core 10 Sqmm to 3.5 Core 35 Sqmm from wall/Roof/steel Structures of buildings/Storgae Sheds etc and refixing the same in position after replacing of Saddles & Spacers all as directed by Enginner incharge including replacing of cable glands, lugs & making all connections complete as required at site and as directed by Engr-in-Charge. Make - KEI/ Polycab/ Gloster/ Havells
56M & L for Taking down and Refixing the aluminium/copper strip of any size from any position / location ofsheds/ buildings of height up to 30 meter &laid as roof conductor, down conductor, earth contunity conductoor same after straightning the conductor/removal of bends, including replacing the old strips, insulators with new one and saddles all as directed at site Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter. ii) The raete is deemed to be inclusive for providing Procealin insulator, screws, Plugs iii) PCC Block required shall be measure and paid under respective items iv) Span of PCC Block support shall be kept at 70 cm. v) Span of insulation support (without block) shall be fixed at 30 cm space.
57S&F aluminium earth strip as roof/down/earth contunity conductors of size 25x3mm with saddles, Parcelain, insulators, stainless steel screws, washer etc at any position / locationofsheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note -i)The quoted rate is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter. ii) The rate is deemed to be inclusive of Procealin insulator, screws, Plugs etc.
58S&F air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary terminal base plate of thickness not less than 4 mm, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge
59M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick shheet for fixing the block complete all as specified and directed.
60M&L for pre-cast cement concreate block of size 0.15M x0.15M x0.15M for fixing of Aluminium striptype C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the coccrete block on terrace of bldgs of height up to 30 meter all as directed at site Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.
61Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including allfittings for fixing complete as required and directed by Engineer-in-Charge.
62M&L for painting on wall with synthetic enameledpaint of black colour of 200 x 150 mm size and writing work for earth test result with date & year all as specified and directed at site by Engineer-in-Charge.
63Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
64Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed.
65Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
66M & L for sand cushioning by spreading in trenches fine crush sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
67Supply and laying in repairs un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Make: MEHTAB /NATIONAL TILES
68Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Note :- Serviceable cable cover obtained here-in-after shall be reused.
69Dismantling only in repairs of PCC foundation / pole coping from ground level all as per specified.
70M & L in repairs for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
71Supply and Laying in repairs or fixing or passing through pipe, XLPE insulated ISI marked, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required includingdisconnection/taking down of existing cable all as specified. Make: Polycab/ Havell"s/ KEI/ Gloster
72-Ditto- all as per item No 71 above here-in-before but 10 Sqmm 4 Core complete all as specified & directed. Make: Polycab/ Havell"s/ KEI/ Gloster/ Universal
73M & L for earthing in repairs complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materils
74S & F in repairs copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
75M & L in repairs for reinforced cement concretenominal mix M-20(using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed.(Note - Reinforcement and form work will be measured and paid separately).
76M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 12 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
77M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippusincluding cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
78M & L in repairs for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.
79Dismantling only in repairs of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
80Supply, Fixing in reparis / replacement and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make: Bajaj
81Preparingsurfaces in repairs of steel tubular swaged pole LT with scraping out old paint by emmery paper, wire brush complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint background and stripping with black and yellow synthetic enamel paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market
82M & L in repairs for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black synthetic enamel paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height all as directed by Engineer in Charge. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market
83Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel
84Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel
85Supply & Fixing LT, Air Circuit Breaker, operational voltage 660 Volts, insulation voltage 1000 Volts, AC, 50 cycles, 3 phase, 4 pole, Manual draw out type, rated current rating 630 amps and of breaking capacity 50 KA with quick make, quick break with manual operating mechanism complete with Triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating "Trip Healthy Circuit" ancillary switch etc complete over load release 400 to 600 Amps complete all as specified and directed. Make - Legrand/ L&T/ Schneider/ABB/C&S/Siemens
86M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing wateringfinish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top", including removal of surplase soil all as directed.
87M&L for taking down old unsv and supply & lay 3Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts,all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS/ BENLO
88Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and remove the carbon after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LEDwill be measured and paid separately on respectiveitemof Sch "A"here-in-after].
89Supply and fix in repairs flood lightluminaire with polycarbonate optics pressure die cast housing IP 66 ingress protection, 4 KV in-built and 10 KV external SPD, having efficiency not less than or equal to 150 lm/watt, CCT 5700oKin buildings etc the fitting shall be of LED type 150 Wattscomplete all as specified. Make : Bajaj/ Jaguar/ Wipro/ Benlo/ Havells/ Crompton
90Dismantling complete old Bolard light fitting and Supply & Fix 8/9 watts LED Bollard Garden light fittings with efficient high outputLED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation0.3 Meter x 0.3 Meter x 0.3 Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry complete. Make:- Havells / Bajaj/ Crompton/ Jaguar/ Benlo/ Wipro
91Supply and fixing Post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. Make:- Bajaj/ Havells / Benlo/ Crompton/ Jaguar/ Wipro
92Supply and fixing Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. Make:- Havell"s/ Crompton/ Jaguar/ wipro/ Bajaj/ Benlo
93S & F in repair/replacement of LED Driver 60 to 70 Watts Suitable for street light fitting operating on 230 Volts, 50 Hz, AC Supply complete all as specified and directed. Make:Crompton /Havells/Bajaj
94S & F in repair/replacement of LED Driver 30 to 40 Watts Suitable for street light fitting operating on 230 Volts, 50 Hz, AC Supply complete all as specified and directed. Make:Crompton /Havells/Bajaj
95M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 25 to 50 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M
96M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 120 to 185 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M
97S & F in repair Analog Time switch astronomical type FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY). Make L&T/ C&S
98S & F in repair 3 Pole power contactor MNX-18 of coil voltage 415 VoltsMake - L&T/ C&S
99S & F in repair spare coil for MNX-18 3 pole power contactor of 415 voltsMake - L&T/ C&S
100M & L for earthing in repairs complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
101M & L for depute service representativeto attend the LED Solar Light fittings of 18wattage once in a month . Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd for 26 fittings Every Fortnightly a) Solar PV Modules - Check the Circuit Voltageand current characteristics. Also, check the mechanical integrity of the Solar PV Modules. b) Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. Note:- Electrolyte solution will be measured seprately under this Schedule. c) Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring. d) Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed. e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering ifa any required f) Module Cleanliness - Cleaning of the dust accumulatedover the Solar Module, and taking corrective measures
102M&L for preparation of old painted surfaces of Solar Street Light Poles including acessoriesby scarping old paint and applying two coats ofpaint including numbering of pole with black synthetic enamel paint all as directed by Engineer in Charge. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market
103Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar or equivalent
104Supply and fix inreplacement of low maintenance VRLA lead acidic batteryof 120 AH suitable for 1 x 18 watt Soalr Lightfitting all as per recommanded by Manufracturer
105Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required
106Supply only electrolyte solution to be incorporated in servicing, suitable for Solarcharged battery of any capacity.
107Supply & fix in repairs of defective worn out GI funnel of 15 mm dia size suitable for GI/ Copper earthing pits complete all as specified and directed.
108Supply only Industrial type commercial salt suitable for renewal of GI/ Copper earth plate complete all as specified and directed.
109Supply only Industrial type Charcoal suitable for renewal of GI/ Copper earth plate complete all as specified and directed.
110M & L in repairs/ replacement of broken old us PCC earth chamber alongwith PCC cover of size 600 x 600 mm complete all as specified and directed.
111Supply and lay in repairs cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size:3.5 core 25 Sqmm including taking down of old u/s cable complete all specified and directed. Note - Excavation and earth work will be mesured and paid seprately
112M & L in repairs spray painting inside, outside complete tothe LT panel boards outdoor type of size not exceeding 2.0 Mtrwidth 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. Make: PAINT: ASIAN/ NEROLAC/ BERGER
113M & L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge..
114S & F in repairs of HDPE pipe 100 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etcall as directed by Engr-in-Charge. Make: SUDHAKAR / PRAYAG
115M & L in repairs MCCBs 3 Pole 250 Amps,25 KA including connecting up electrically with suitable lugs glands spreader links etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELL"S/ C&S/ INDOASIAN
116M & L in repairs MCCBs 3 Pole 200 Amps,25 KA including connecting up electrically with suitable lugsglands spreader links etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELL"S/ C&S/ INDOASIAN
117M&L in repairs MCCBs 3 Pole 100 Amps,16 KA including connecting up electrically with suitable lugsglands spreader links etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELLS/ C&S/ INDOASIAN
118M&L in repairs MCCB 63 Amp, 4 Pole,16 KA including connecting up electrically with suitable lugsglands spreader links etc all as specified and directed by Engineer –in –Charge. Make: HAVELL"S/ SCHINDER/ LEGRAND/ INDOASIAN
119M&Lin repairs for Astronomical analog 24 Hrs, 240 V FM1 Quartz type daily Timer switch for controlling street lights contactors all as specified and directed by Engineer –in –Charge. Make : L & T/ Indo Asian/ C&S
120S&F in repair of building Security lightfitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
121S&F in Repairs 36 W LED recessed full lit lminaire with glare free niform illumination with longer life and less maintainance 2x2 fitting mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement all as specified and directed in EIC. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
122M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using comutrised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately. (ii) Cable joint will be measured and paid seperetely. (iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
123M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed.
124Supply and Fix in repairs MCCB 100 Amps 25 KA, 4 pole, 415 Volt IN SHEET STEEL ENCLOSUREin open construction, panel mounted 0n wall with base plate for mounting in panel, including taking down of old MCCB with enclosure and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd/ C&S/ L&T
125Supply, install,in repair/ renewal feeder piller box outdoor type, IP-54 protection CPRI approved, factory fabricated, cubical panel wall mounted, self supported, free standing type, made out of 3.15m thick CRCA sheet with locking arragement, suitable for 3 phase, 4 wire, 415 volt, 50HZ, AC supply including suitable size copper conductor control wiring and powder coating with connecting the cables with necessary cable glands, lugs etc proper arrangement for veritilation complete with and including the following accessories :- (i) Electrolytic Copper bus bar Phases & Half for Neutral for 150 Amps- 01 set (a) MCCB 4 pole 25 KA 100 Amp - 1 Nos (b) MCB TPN 40 Amp 10 KA- 01 Nos (c) MCB SPN 32 Amp 10 KA - 01 Nos
126Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSUREin open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/ Havells/ Standerd/ C&S/ L&T
127M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
128S&F GI 32x6 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn inpipe, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
129Suppli and fix in repairs Halogen lamp with fixture complete of capacity 500/ 1000 watt operating on 230v, single phase, AC, 50 Hz supply complete all as specified and directed. Note : A sum of Rs. 1,08,589.00 towards sch of credit shall be deducated to arrive the contract sum.