Tender For Comprehensive Maint Of E/M Nature Of Works And Repair/Replacement Of Fitting Fixtures In Cariappa Vihar, Mt Line, Station Wksp Eme And Salaria Officers Enclave (Dwarka) Under Ge (West) Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Comprehensive Maint Of E/M Nature Of Works And Repair/Replacement Of Fitting Fixtures In Cariappa Vihar, Mt Line, Station Wksp Eme And Salaria Officers Enclave (Dwarka) Under Ge (West) Delhi Cantt-10. Submission Date for this Tender is 24-04-2024. Electromechanical Work Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43082892
Tender For Comprehensive Maint Of E/M Nature Of Works And Repair/Replacement Of Fitting Fixtures In Cariappa Vihar, Mt Line, Station Wksp Eme And Salaria Officers Enclave (Dwarka) Under Ge (West) Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
24-04-2024

Tender Details

Comprehensive Maint Of E/M Nature Of Works And Repair/Replacement Of Fitting Fixtures In Cariappa Vihar, Mt Line, Station Wksp Eme And Salaria Officers Enclave (Dwarka) Under Ge (West) Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE MAINTENANCE OF E/M NATURE OF WORKS & REPAIR/REPLACEMENTS OF FITTING FIXTURE IN CARIAPPA VIHAR & MT LINE,STATION WKSP EME AND SALARIA OFFICERS ENCLAVE (DWARKA) UNDER GE WEST DELHI CANTT-10
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring from woodenbattan orconduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc.) and making good disturbed surfaces of walls, floor etc.
2M&L point wiring concealed in wall with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor two run and drawing in& including rigid PVC conduit in walls and on surface conduit for Beam/ceiling/cloumn portion FRLS grade ,ISI marked ,terminal box of suitable thickness and with 3 mm thick hylam sheet cover as per required cuttings for terminal boxes also including porvision ofearth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting complete all as specified for the following :-
3(a)One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
4(b)One 3 pin socket outlet 5 hole 5 Amp independent board with including PVC unsheathed copper conductor 1.5 Sqmm cable asearth wire connected to common earth dully complete all as specified and directed.( socket & switches to be measured and paid separately).
5(c)-ditto- as above item No 2 (a) but Same board.
6M&L One power point concealed in wall with insulated stranded copper conductor cable 2.5 Sqmm single coretwo run and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire one run including PVC cunduits connected to dolly common earth points complete all as specified and directed. ( socket and switches to be measured and paid separately)
7M&L point wiring in existing conduit with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor two run and drawing in existing rigid PVC conduit FRLS grade ,ISI marked ,without terminal box and with 3 mm thick hylam sheet cover for terminal boxes as per required cuttings at site; also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable one run connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :-
8(a)One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
9(b)One light point controlled by two, two way switch ( switch to be measured and paid separtely)
10(c)One 3 pin socket outlet 5 hole 5 Amp independent in existing conduit with insulated stranded copper conductor cable 1.5 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 1.5 Sqmm stranded conductor as earth wire connected to dolly complete ( socket and switches to be measured and paid separately)
11(d)-ditto- as above item No 8 (a) but Same board.
12M&L One power point in existing conduit with insulated stranded copper conductor cable 4 Sqmm single core two run and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire one run connected dully to common earth complete all as specified and directed. ( socket and switches to be measured and paid separately).
13M&L One power point in existing conduit with insulated stranded copper conductor cable 2.5 Sqmm single core two run and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire one run connected dully to common earth complete all as specified and directed. ( socket and switches to be measured and paid separately)
14M & L for One 3 pin socket outlet, 5 Amps, independent,with cables 1.5 sq. mm size PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core two run Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core one runConforming to IS : 694 of green colour asearth wire dully connected to common earth drawn in sameconduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 5 Amp switch and 3 pin 5 Amp socket as required complete. Note: switch & socket to be measured and paid separately.
15M & L for One 3 pin socket outlet, 15 Amps, independent,with cables 2.5 sq. mm size PVC insulated and unsheathed cable 2.5 sq mm (nominal area) multi stranded copper conductor single core two run Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour asearth wire one run connected dully to common earth drawn in same conduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 15 Amp switch and 3 pin 15 Amp socket or as per requirements complete all as specified and directed. Note:switch & socket to be measured and paid separately.
16Identifying and rectifying the Defects pertains to ceiling fans/exhaust fans/Air ventilation Fanand connects electric circuit, tightening of loose wirring/conduits /fan capacitors and connection carrying out minor repairs incl blade alignments , screwing/ tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs,complete all as specified and directed.
17Dismantling of complete defective Ceiling fan of 1200 mm sweep i.e. down rod with its Canopies, Shackle, Blade, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding,ball bearing, gun metal bush etc. complete to carry out the following repairs:-
18Notes :- (a) Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, ( weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed & specifications and as directed by Enge-in-charge.
19(b) Re-assembling complete Ceiling fan by fixing only serviceable of old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes,blades, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, cleaning outer body & surfaces etc all as directed.
20Ditto- all as per Item No. 17 here-in-before but Air ventilation PVC body/ metal body exhaust fan of size 200/230/300 mm sweep.
21Ditto- all as per Item No. 17 here-in-before but only overhauling of celing fan 1200mm/1400mm by greasing and oiling,replacement of unserviceable/defective components, except rewinding of starter winding complete all as directed.
22Note Sl.No. 17 :(a) Spare parts found unserviceable/defective will be measured and paid separately under relevant item as Supply and fix in repair .
23Supply in Repairs/Replacements of following spare of Ceiling fan 1200mm /1400mm sweep of different make:-
24(a) Fan Condenser of capacity 2.5/3.5 mfd, 220 Volts, AC 50 Hz, plastic-casing, two terminal-copper wire, complete all as specified and directed.
25(b) Rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm/1400mm sweep.
26(c) Split Pin
27(d) Ball bearing of size 6201/6202 as per sample complete all as specified and directed.
28(e) Gun metal bush as per sample.
29(f) Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed.
30(g) ceiling fan blade 1200 mm sweepmade up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed.
31M & L for preparation of old painted/rusted surfaces of 1200/1400 mm sweep ceiling fan and re-fixing the same after painting of the same with white colour synthetic enamel paint by spraying including filling cavities with filler & one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, complete all as specified and directed by Engr-in-Charge. NOTE:-All T&P and labour team as required will be provided by the contractor and cost deemed to be included in the quoted rate.
32M&L in repair louvr shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 6 mtr heightmaking good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to fix properly the exhaust fan shutter complete all as specified and directed.
33M & L for Overhauling/Dismantling of defective/rusted Geyser of 25 Ltr capacity, removing inlet/outlet connections, taking out U/S parts by unscrewing bolts and nuts etc.Checking defects and re-assembling the Geyser after refixing serviceable/new parts & cleaning, dicling and refixing only serviceable items and re-installing the Geyser in suitable place/position and connecting inlet-outlet connections & testing complete, all as specified and directed by Engr-in-charge. Note:(a) Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch "A" ).
34Supply in Repairs/Replacements of following spare parts of geyser storage type of different make for capacity 25 ltrs (Make of spare parts shall be of existing make or as per samples as required)
35(a)Apparatus assembly duly prewired without heating element and thermostat/thermal cutout.
36(b)Indication lamp (Green/Red) as per sample.
37(c)Thermostatas per sample.
38(d)Heating element 2.0 KW, trianglular/circular or as per sample given at site complete all as specified and directed.
39(e ) cover outer for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed.
40(f)stainless Steel inner tank of 25 Ltrs capacity complete all as specified and directed as .
41(g) geyser bottom and top cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed.
42(h) geyser SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed.
43Taking down DBs,MCBs, Main switch, etc of any make and type from the site and making good to the disturbed surfaces complete all as specified and directed.
44M&L in repair MCB distribution board SPN08 way with 200 Amp rated bus bar double door complete all as specified and directed.
45Supply and fix in repairsheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
46Supply and fixingin repair amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
47(i) SP 5 To 63 AMP
48(iii) SPN 40 to 63 AMP
49Supply and fixing in repair 415V 10KA "C" curve miniature circuit breaker (MCB) TPN 100 AMP 4 pole complete all as specified and directed.
50Taking down carefully sub main wiringthree single run 6/10 Sqmm of any make and type complete all as directed.
51Supply and fix in repair for submain wiring with two run single core PVCinsulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm for submain wiring and connection complete with including rigid PVC conduit or existing conduits as required on site FRLS grade,and one run of 6.0 sqmm unsheathed copper conductor stranded cableas earthwire dully connected to common earth complete all as specified and directed.
52Supply and fix in repair for submain wiring with two run single core PVCinsulated FRLS 1100 Volts unseathed stranded copper conductor cable 10.0 Sqmm for submain wiring and connection complete with including rigid PVC conduit or existing conduits as required on site FRLS grade,and one run of 10.0 sqmm unsheathed copper conductor stranded cableas earthwire dully connected to common earth complete all as specified and directed.
53Supply and fix in repair MCCB 100 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed.
54Supply and fix in repair MCCB 125 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed.
55Supply and fix in repair MCCB 250 Amps, 4 Pole 415 volts 25 KA 50 HZ complete all as specified and directed.
56Supply and fix electronic meters temper proof LCD display with polycarbonate cover sinle phase 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
57M&L in repair of earthing complete with GI steel earth plate electrode 60cm x 60cmx6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32x6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 using 20mm graded aggregate, pre-cast RCC (1:2:4) type-B, over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule Part-I and testing after completion.
58Identifying and rectifyingthe minor defects pertaining to internal electrification of any type and nature such as taking down defective switch/socket/ceiling rose/holders/fittings / fixtures any type, rectification of faulty electric circuits,tightening of loose connections, replacement of old u/s wiring/conduits/casing capping & connections etc. complete all as specified and directed.
59Identifying and rectifyingthe minor defects pertaining to internal electrification of any type and nature such as repair in Bldg LT panels ,taking down defective MCBs / MCB DBs/SPN DBs / TPN DBsany type and repairing/replacements, rectification of all type of electrical faults, tightening of loosePanels electric cablels connections & replacement of old u/s MCBs/DBs as required on sites complete all as specified and directed.
60Supply and fix in repair copper wind motor, single phase, 240V suitable for PVC fresh air fan of sweep size 225/ 250/300 mm as per sample given at site complete all as specified and directed.
61Supply and fix in repair copper wind motor, single phase, 240V suitable for metallic heavy duty exhaust fan of sweep size 300 mmas per sample given at site complete all as specified and directed.
62Supply and fix in repairmetal plug top 20 Amps3 pin 230- volts complete all as specified and directed.
63Supply and fix in repairPVC plug socket 20 Amps3 pin 230- volts complete all as specified and directed.
64Supply and fix in repairsingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
65Supply and fix in repairsingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
66Supply and fix in repairsingle core PVC insulated cable4.0Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
67Supply and fix in repair Single core PVC insulated cable10Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
68Supply and fix in repairsingle core PVC insulated cable6Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
69Supply and fix in repaircopper cable flexible 3 corePVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge.
70S & F in repair PVC insulatedflexible cable threecore Copper conductor of size1.00 Sqmm, ISI marked, covered with white colour round insulation complete all as specified and direced.
71Supply and fix in repair , 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC armoured,PVC sheathed 6 sq. mm nominal cross section, 2 core.
72Supply and fix in repairhylum sheets 3 mm thick (ISI marked) of the following sizes :-
73(a) Sheet as per sample suitable for mounting one piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed.
74(b) Sheet as per sample suitable for mounting one piano switch 15Amp and one 15Amp socket dully cut for mounting as above complete all as specified and directed.
75(c) Sheet as per sample suitable for mounting thre piano switch 5Amp dully cut for mounting as above complete all as specified and directed.
76(d) Sheet as per sample suitable for mounting four piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed.
77(e) Sheet as per sample suitable for mounting five piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed.
78Supply and fix in repair LED batten luminaire surface mounted 2 feet system wattage of 10 watts and system lumen>120 output ,CRI > 80, power factor > 0.95, THD < 10%, color temperature 3000K- 6500 K ,IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
79Supply and fix in repair LED batten luminaire surface mounted 4 feet system wattage of 20 watts and system lumen>120 output ,CRI > 80, power factor > 0.95, THD < 10%, color temperature 3000K- 6500 K ,IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
80Supply and fix in repairs decorative Wall light fittings suitable forLED bulb of 9/12 watt (B-22), including connection with all necessary fixing accessoriescomplete all as specified and directed by Engr-in-Charge.
81Supply and fix in repair 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W ,Power Factor >0.95, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature 3000K-6500K, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmmcopper conductor flexible wire fixed completeallas specified and directed.
82Supply and fix in repair 30 watts High efficient LED Building Security light fitting with pressure die castAluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie is >100lm/W .The color temperature is around 6500 K .The luminaire is IP:66 protected It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 150-270V.Complete as specified and directed.
83Supply & fix in repair Slim Surface mounted round LED panel aluminium die cast body with premium diffuser to ensure glare free & even distribution of lights capacity 18 watts,3000K-6500 K , Luminarie is >100lm/W complete with electric connection all as specified and directed by Engr-in-Charge.
84Supply and fix in repairs LED bulb of 9 watt (B-22),with lumen >900 lm/W including dully connecting, fixing with all accessoriescomplete all as specified and directed by Engr-in-Charge.
85Supply and fix in repair switch piano flush type 5 Amp SP one way complete all as specified and directed.
86Supply and fix in repair switch piano flush type 5 Amp SP two way complete all as specified and directed.
87Supply and fix in repairswitch piano flush type 15 Amp SP one way complete all as specified and directed.
88Supply and fix in repairsocket outlet 5 pin 5 Amp flush type complete all as specified and directed.
89Supply and fix in repairsocket outlet 2 in 1,3 pin 5/15 Amps complete all as specified and directed.
90Supply and fix in repairceiling rose 3 phase PVCpolycorbonate,insulated body complete all as specified and directed.
91Supply and fix in repairswitch type normal electronic fan regulator 5 stepcomplete all as specified and directed.
92Supply and fix in repairbell push,flush type,5 amp complete all as specified and directed.
93Supply and fix in repairbell ding dong AC,230 volts,single pole complete all as specified and directed.
94Supply and fix in repairinsulated body pvc , angle holder (metal ring) B22 type ISI marked complete all as directed.
95Supply and fix in repairswitch Modular type 6 Amps one way 230V AC as per sample complete all as specified.
96Supply and fix in repairswitch Modular type 16 Amps one way 230V AC as per sample complete all as specified.
97Supply and fix in repairModular socket outlet 5 pin 6 Amp socket 2 module as per sample complete all as specified.
98Supply and fix in repairswitch bell push Modular type 6 Amps 1W-1 module, 230V AC as per sample complete all as specified.
99Supply and fix in repairModular socket outlet 5 pin 16 Amp socket 2 module as per sample complete all as specified.
100Supply and fix in repairModular fan regulator 1 module as per sample complete all as specified.
101Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
102Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified.
103S&F in repairfor energy saving recess/surface mounted luminaire 36/40 W, incl LED Driver, high efficiency, Ultra modern designed LED Luminaire which provides soft- glare free light and symmetrical illumination, suitable for Armstrong/Grid ceiling of 600X600 mm, incl Provn ofthree core cable of copper conductor of size 1.5 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface withallfixing arrangement complete all as directed.
104Supply in rpairs/replacements of Self Adhesive PVC ElectricalInsulation tape of size 1.80 cmX6.5 m X0.125 mm, mix colour box in a packet of 12 roll complete all as specified and directed.
105Supply in rpairs/replacements of brass screw1/2 inch to 1.5 inch inpacket of 50 pcs complete all as specified and directed.
106Supply in rpairs/replacements of Wall Rawl Plugs/Gitti in packets of 100 pcs as per sample complete all as specified and directed.