Military Engineer Services-MES has published Tender For Repair / Replacement Of Water Cooler, Desert Cooler, Deep Freezer And Refrigerator In The Area Of Age E / M Ext ( Ws & Ac ) Under Ge E / M Lucknow. Submission Date for this Tender is 27-04-2024. Air Cooler Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Apr-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-04-2024 |
Sl. No. | Item Description |
1 | Deployment of manpower for dismantling of desert cooler of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal / replacements of Parts & motor, reassembling andinstallation of the same on same location and making electric connection required to make fully functional etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item (s) listed herebelow. |
2 | Supply only PVC front grill complete all as specified and directed. |
3 | Supply onlyof Piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. |
4 | Supply only PVC distribution box suitable for piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. |
5 | Supply only PVC elbow suitable for 15 mm dia PVC pipe of 24"/18" sweep desert cooler complete all as specified and directed. |
6 | Supply only PVC distributor suitable for 15 mm dia PVC Pipe of 18"/24" sweep desert cooler complete all as specified and directed. |
7 | Supply OnlyPVC connection 15 mm dia with brass ferule both and length 600 mm complete all as specified and directed. |
8 | Supply only PTMT float valve, 15 mm dia complete all as specified and directed. |
9 | Supply only copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed. |
10 | Supply only copper conductor three core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed. |
11 | Supply only PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor and distributor to elbow complete all as specified and directed. |
12 | Supply only replacement submersible pump for desert cooler single phase, 1/40 HP,230volts complete all as specified and directed. |
13 | Supply only Exhaust fan blades 18"/20" sweep heavy duty(as per sample) complete all as specified and directed. |
14 | Supply only wood wool pad (As per sample) including wiremesh (jali) suitable for desert cooler325 mm to 500mm sweep complete all as specified and directed. |
15 | Supply only kit fan, motor, minimum 1 inch core, copper winding, less consumption of electricity, more durable, heavy duty, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"sweep size suitable for desert cooler complete all as specified and directed. (Make:- Crompton /Champion /Havells/Usha) |
16 | Supply only exhaust fan motor, single phase, 230 volt AC, 1/3 HP, copper winding less consumtion of electricity, more durable heavy duty complete with blade arm 18"/20"sweep size suitable for desert cooler complete all as specified and directed. (Make:- Champion/Crompton greaves/Havells/Usha) |
17 | Supply only set of 3 panels made out of PGI sheet 24 gauge thick with wood wool pads and wiremesh, in required quantity duly filled complete all as specified and directed. |
18 | Taking out defective burnt exhaust fan of18" / 24" sweep of any make, transporting tocontactor"s workshop, opening of exhaust fan / taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position complete all as specified and directed. |
19 | Taking out carefully 325 to 500 / 600 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank after preparation of old painted surfaces and reassembling and fixing in positioncomplete all as specified and directed. |
20 | M&L for repairing of leakage of tank by brazing / solderingof any size of desert cooler, testing the leakage water complete all as specified and directed. |
21 | M&L for Renewal of desert cooler body, suitable for 450 mm / 500 mm sweep exhaust fan made out of 24 gauge PGI sheet with front grill, side panel include wood wool pad / wiremesh set, switch, regulator, flexible cable include plug top complete all as specified and directed. Make ;- Champion/ Summerking. |
22 | M&L for fabrication of GI water storage tank for desert coolerof 18" / 24" any makemade out of 24 SWG PGI sheet including rivetting brazing / soldering including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed. |
23 | Dismantling of existing repairable water cooler of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal / replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. to make it fully functional complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
24 | Supply onlyPVC pipe connector including flange, screw, CP nozzle of nipple, female nozzle and extentioncomplete all as specified and directed |
25 | Supply only blower motor with bladeAC 240 volts, 50 HZ single phase, of 1 /10 HP capaciitescomplete all as specified and directed. |
26 | Supply only blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/16 HP capaciitescomplete all as specified and directed. |
27 | Supply only blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/8 HP capaciitescomplete all as specified and directed. |
28 | Supply only aluminium fan blade of blower motor of 1/16 HP complete all as specified. |
29 | Supply onlyPVC fan blade of blower motor of 1/8 or 1/10 HP complete all as specified. |
30 | Supply and fix in repaircondensing coil for 150 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge. |
31 | Supply and fix in repaircondensing coil for 60/120 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge. |
32 | Supply and fix in repaircondensing coil for 40/80 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge. |
33 | Supply onlyCP Brass push cock(inner or outer threaded) of 15 mm bore size completeall as directed by the Engineer-in-Charge. |
34 | Supply only 32 mm PVC pipe with clip and strainer tee Elbow all as specified and directed by Engineer-in-Charge. |
35 | Supply only starting relay for 1 TR water cooler complete all as specified and directed . |
36 | Supply only starting relay for 1/3 TR water cooler complete all as specified and directed . |
37 | Supply only runnuing capacitor of 6 mfd complete all as specified and directed . |
38 | Supply onlycapacitor of 2.5 Mfd capacity all as specified and directed |
39 | Supply onlyof capacitor of 4.00 Mfd capacity all as specified and directed |
40 | Supply only running capacitor of 10 mfd capacities complete all as specified and directed. |
41 | Supply only overload protector for 1.00 TR compressor complete all as specified and directed . |
42 | Supply only overload protector for 1/3TR compressor complete all as specified and directed . |
43 | Supply only Thermostat long tail for water coolercomplete all as specified and directed by Engineer-in-Charge . |
44 | Supply only Thermostat short tail for water coolercomplete all as specified and directed by Engineer-in-Charge. |
45 | Supply only gas filter, flare type, 3/"x 1/2" flare, all as specified and directed by EIC. |
46 | Supply onlyfloat valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified. |
47 | M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally andspray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaceswithout disturbing the components & wiring etc. complete and reconnceting complete all as specified and directed. |
48 | All as per item No 47 above but for 40 / 80 Litres capacities of water coolers |
49 | All as per item No 47 above but for 60 / 120 Litres capacities of water coolers |
50 | Checking of leakage in refrigerant system of water cooler of 150 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
51 | Checking of leakage in refrigerant system of water cooler of 60/120 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
52 | Checking of leakage in refrigerant system of water cooler of 40/80 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
53 | Transporting defective blower motor of 1/ 16 HP capacities from AGE E/Myard to contractor"s workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wireincluding insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and directed. |
54 | All as per item No 53 above but for capacity of 1/8 HP |
55 | Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing andSupply&fixing new compressor(sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-22, of 1 TR Capacity ( Make Emmerson Model HR-13) or equivalent of other specified make& Modelcomplete all as specified and directed. Note : Refrigerant gas will be provided by contractor. |
56 | Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testingof 150 litres capacities of water coolers complete all as specified and directed by Engineer-in- Charge.(Make Make Emmerson Model KCJ 34) Note : Refrigerant gas will be provided by contractor. |
57 | Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testingof 40/80 litres capacities of water coolers complete all as specified and directed by Engineer-in- Charge.(Make Make Emmerson Model KCJ 444). Note : Refrigerant gas will be provided by contractor. |
58 | Dismantling of existing repairable refrigerator any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. to make it fully functional complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
59 | Supply only starting relay, open type for refrigerator of capacity 165/300/310 litres complete all as specified and directed. |
60 | Supply onlyover load protector for 1/6 HP refrigerator of capacity 165/300/310 litres complete all as specified and directed. |
61 | Supply onlythermostat defrost type for refrigerator complete all as specified and directed. |
62 | Supply onlys thermostat non defrost type for refrigerator complete all as specified and directed. |
63 | Supply only Fan motor with blade of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
64 | Supply only Tharmal fuse of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
65 | Supply only Timer of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
66 | Supply only Bimetal of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
67 | Supply only Door switch of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
68 | Supply only lamp of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
69 | Supply only Defrost Heater of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
70 | S&F in reapairPCB for 300/310 ltr refrigerators, complete all as specified and directed. (Make-Samsung/LG or others as required) |
71 | S&F in repair PCB for 300/310 ltr refrigerators (Inverter type), complete all as specified and directed. (Make-Samsung/LG or others as required) |
72 | M&L for dismantling of defective PCB of Refrigerator any make, model and capacity and transporting to contractors workshop for repair of the same,transporting back to site & refixing to Refrigerator to ensure proper functioning of the AC complete all as specified and directed. |
73 | M&L for dismantling of defective PCB of Refrigerator Inverter type any make, model and capacity and transporting to contractors workshop for repair of the same,transporting back to site & refixing to Refrigerator to ensure proper functioning of the AC complete all as specified and directed. |
74 | Renewal of Refrigerator body, capacity 190 Ltrwith front door, cooling coil, freezer and internal accessories include flexible cable include plug top complete all as specified and directed. Make ;- Whirlpool/ LG/ Godrej/Samsung. |
75 | S&F in repair Freezer for capcity 165/180/210 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required) |
76 | S&F in repair Freezer for capcity 300/310 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required) |
77 | M&L for disconnecting of Refrigerator of various capacities from its position, cleaning by washing with washing powder and with fresh water externally and internally andspray painting with synthetic enamel paint of approved tint/colour to all painted surface of Refrigerator after preparation reconnceting and to make it fully function complete all as specified and directed. |
78 | S&F condensing coilof 165/190/195 litres capacitiesrefrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging ofNon CFC gas as per required quantity and testing complete all as specified and directed. Note : Refrigerant gas will be provided by contractor. |
79 | All as per item 78 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators |
80 | Checking of leakage in refrigerant system ofrefrigerator of 165/190/195 litrescapacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
81 | Checking of leakage in refrigerant system ofrefrigerator of 286 /300/310 litrescapacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
82 | Renewal of Refrigerator body, capacity 240 Ltrwith front door, cooling coil, freezer and internal accessories include flexible cable include plug top complete all as specified and directed. Make ;- Whirlpool/ LG/ Godrej/Samsung. |
83 | Taking down unsv compressor from the regrigerator and Supply and fixing new sealed unit compressor suitable for 165/190/195 litres refrigerator ( 1/8 TR) capacities , charging with gas and making connections and testing complete all as specified and directed by Engineer-in- Charge. Make- LG/Whirlpool/Samsung/Godrej). Note : Refrigerant gas will be provided by contractor. |
84 | Description all as per item 83above but for capacity of 240/286/300/310 ltrs (1/6 TR) refrigrators.(Make-LG / Whirlpool / Samsung / Godrej) |
85 | Dismantling of existing repairableDeep freezer any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
86 | Supply onlystarting relay for 200 Ltr. Capacity deep freezer complete all as specified and directed. |
87 | Supply only starting relay for 300 Ltr. Capacity deep freezer complete all as specified and directed. |
88 | Supply only over load protector suitable for 200/300 Ltr deep freezer complete all as specified and directed. |
89 | Supply only running capacitor for deep freezer any make and capacities complete all as specified and directed. |
90 | Supply only thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and directed. |
91 | Supply only starting capacitor for deep freezer any make and capacities complete all as specified and directed. |
92 | Taking down defective compressor of following capacity of deep freezer of any Make and depositing ,supply andfixing sealed unit compressor as specified here underincluding brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Kirloskar complete all as specified and directed. Note : Refrigerant gas will be provided by contractor. |
93 | All as per item No above 92 but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar |
94 | Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
95 | Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hzincluding disconnection and reconnecting and testing complete all as specified and directed. |
96 | Supply and fix in repair Polycarbonate Plug top 3 pin 5/6 Amp complete all as specified and directed. |
97 | Supply and fix in repairPolycarbonate Plug top 3 pin 16 Amp complete all as specified and directed. |
98 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 36 Mfd in plastic/ metal container complete all as directed by EIC. |