| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | Removing building materials to a distance of exc. 1.0 Km but not exc. 5.0 Km (1 Metric tonne = 1 Load and One Cum = 1735 Kgs) out side MD Land Complete all as directed. |
| 3 | M&L for 75 mm thick, PCC 1:3:6 type C2, using 40mm graded stone aggregate, finished even and smooth without using extra cement as in plinth protection, complete all as specified and directed. |
| 4 | M &L providing cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in lintel upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, stringcourses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates,kerbs incl weathering slightly rounded or chemfered angles and throating as directed. |
| 5 | Dismantling unframed timber scantling 40 sq cm and over in section in any positioncomplete all as speicifed and direceted. |
| 6 | Dismantling asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings,incl ridgesetc complete all as speicifed and as direceted. |
| 7 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coveringscomplete all as speicifed and direceted. |
| 8 | Dismantling framed timber fillets, rails, posts, rafters, purlins etc under 40 sq cm in section in any position complete all as speicifed and direceted. |
| 9 | M&L for preparation of old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enemel paint completeall as specified and directed . |
| 10 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified complete all as specified and directed. |
| 11 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified complete all as specified and directed. |
| 12 | M & LRooftrusses Fe-410W(GdeE-250) quality B (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed. |
| 13 | Dismantling of old Ceiling/boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 14 | S&F anodised aluminium snap grid frame work for false ceiling, size of grid 605x605mm, complete all as specified and directed. |
| 15 | S&F Hangers 4 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified and directed. |
| 16 | M&Lfor 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timer/GI/ Aluminium framework with screws as in ceiling complete all as specified and directed. |
| 17 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing debrits out side the MD land complete all as specified and directed. |
| 18 | S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 19 | S&F coloured Glazed ceramic tile in verticle surface 300x200x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl rendering 10 mm thick on fair faces of brick work or concrete surfaces as backing coat in cement mortar 1:4 complete all as specified. |
| 20 | S&F light shade vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 20 mm thick screed bed in cement mortar 1:6complete all as specified and directed. |
| 21 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified. |
| 22 | M&L 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs,pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with the granite complete all as specified and directed. |
| 23 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 24 | M&L precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in block masonry with solid blocks, exc 10 cm in width and setting in mortar1:6complete all as specified and directed. |
| 25 | Taking down cement plaster on brick or stone walls etc, incl raking out joints, hacking for key scrubbing down with water, etc. complete all as specified and directed. |
| 26 | M&L rendering 15mmthick in Cm 1:6 on bricksurfaces finished even and smooth without using extra cementall as specified and directed. |
| 27 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound as per manufacturer\"s instructions, surfaces finished even and smooth without using extra cement complete all as specified and directed .Note :-Water proofing compound shall be measured and paid for separatelyunder relevant item of this schedule. |
| 28 | Supply only integral water proofing compound ISI Marked as approved, all as specified and as directed by Engineer-in-Charge. |
| 29 | M&L for preparation of newly plastered surfaces of wall and applying two coats ofdistemper oil emulsion white or tint with priming platered and other surfaces incl 1 mm thick wall care putty on plastered surface complete all as specified. |
| 30 | M&L for preparation ol new plastered surfaces of walls Finishing walls with Acrylic Smooth exterior paint of required shade : for new works (Two or more coat applied @ 1.67 ltr/10 sqm )over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed. |
| 31 | M&L for complete removal of existing treatment of wall surfaces and applying two coats ofdistemper oil emulsion white tint with primer on plastered surfaces including 1 mm thick wall care puttyincluding stopping of nail holes, filling of cracks, etc and cleaning all window panes from splashes / droppings, complete all as specified and directed. |
| 32 | M&L for preparation of old plastered or unplastered surfaces of walls and cornicesand applying one coat of white washupto 5th floor of bldgs all as specified anddirected. |
| 33 | M&L for Preparation of Old surfaces of walland Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and directed. |
| 34 | M&L for 18/19mm thick Pree-laminated Particle board, interior grade, prelaminated one side with decorative choice lamination & otherside balancing white lamination, fixed with screws to timber framefixed in repairs complete all as specified and directed. |
| 35 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised 30mm width of flap complete all as specified and directed. |
| 36 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) not exc 1.5 sqm all as specified and directed |
| 37 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) exc 1.5 sqm but n.exc 4 Sqmcomplete all as specified and directed. |
| 38 | S&F second class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chemfered, put together with glue pinned at joints, supplied and fixedcomplete all as specified and directed. |
| 39 | S&F second class hard wood 30 mm thickPlain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treatedcomplete all as specified and directed. |
| 40 | Taking down and re-fixing in same openingshuttersof any description exc 1.0 Sqm but n.exc 2 Sqmafter necessary repair complete all as specified and as directed. |
| 41 | Taking down and re-fixing in same openingshutters or Aluminium partition/Door of any description exc 1.0 Sqm but n.exc 2 Sqmafter necessary repair complete all as specified and as directed. |
| 42 | S&F Powder Coated aluminium frame for, frame work, partions doors, windows, ventilators and aluminium grills for windows etc, with one or more rebates icludig joinning cleat for rebates including joining cleats for fixing etc, complete all as specified and directed . |
| 43 | S&F Powder Coated aluminium Door shutters, aluminium section weighing 0.55 Kg/m incl necessary joining cleats, glazing clips, rubber packing, handle 02 Nos in each door, hinges Powder coated aluminium spap beading, screws etc, complete all as specified. |
| 44 | S&FSteel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay,complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 45 | S&FSteel ventilator with top hung shutter including hinges, steel peg stay, complete , complete all as specified and directed. |
| 46 | S&F in repairs sheet glass ordinary quality 4mm thick insquare not exc 0.50 Sqm each pane glazingwith oil putty, clip in metal frame and wooden beading in wooden frame completeall as specified and directed. |
| 47 | S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165complete all as specified and directed. |
| 48 | M&L in repair 9 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations fixed with screws to aluminium door shutters complete all specified and directed . |
| 49 | S&F in repairs 5.5 mm thick tinted sheet glass and glazing with aluminium beading & rubber gasket in exc. 0.5 Sqmin each panes complete all as specified and directed. |
| 50 | S&F 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane completeall as specified. |
| 51 | S&F stainless steel 100 mm butt hinges for doors completeall as specified. |
| 52 | S&F 150 mm size extruded aluminium alloy handles fabricated type anodized completeall as specified. |
| 53 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section completeall as specified. |
| 54 | S&F300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy completeall as specified.. |
| 55 | S&F150 mm long floor door stopper of aluminium alloy body and tongue,anodised,with hard drawn steel springcompleteall as specified. |
| 56 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples completeall as specified.. |
| 57 | M&L preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. |
| 58 | M&L preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified. |
| 59 | M&L preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enemel paint over a coat of red oxide completeall as specified and directed . |
| 60 | S&F in repair Aluminium anodised tubular curtain rod 20 mm dia all as specified and as directed complete all as specified and directed. |
| 61 | S&F in repairs fancy type brass bracket with screws for wall corners 25 mm dia including wooden plugs completeall as specified and directed . |
| 62 | Dismantling water tanks and removing exc 500 & n .exc 1000 Ltr capacity completeall as specified and directed . |
| 63 | S&F 1000 Ltr rotational moulded poly-ethylene water tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I completeall as specified and directed . |
| 64 | S&F 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe of brass ferrule and fixed completeall as specified and directed . |
| 65 | S & F of CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down of pipe of 15 mm GI pipe complete all as specified. |
| 66 | S & F PVC connection 15 mm dia with PTMT nuts of length 600 mm completeall as specified and directed . |
| 67 | S&F in repairs sinkwith drainage board made of stainless steel 1 mm thick, kitchen or laboratory, with plugs, washers and wastes coupling, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915mm x460mm bowl size 405mm x 355mm x 178mm (minimum), including PVC waste pipe 40 mm dia complete all as specified and directed. |
| 68 | S&F in repairs angle valves male/female threaded 15 mm nominal bore, brass, fancy type, chromium plated, screwed down, high pressure with Capston head, screwed both ends for iron/CPVC pipes or for unions completeall as specified and directed . |
| 69 | S&F in repairs 75 mm dia PVC (SWR) floor trap, plain with grating incl jointing with solvent cement complete all as specified. |
| 70 | S&F in repairs 32 mm dia PVC waste pipe for Sink complete all as specified. |
| 71 | S&F in repairs 32mm dia Waste coupling, brass, chromium plated for SS Kitchen sinks, WHBetc. with long screwed shanks and fly-nuts, flange end beddedinred leadcement and other end fixed complete upto 5th floor of bldgs all as specified. |
| 72 | S&F in repair 15 mm bore Fancy type Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. |
| 73 | Demolition and breaking up drain pipes upto 110 mm dia (Salt glazed ware, AC or Reinforced concrete/ PVC(SWR)) set in cement mortar or solvent. |
| 74 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 75 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 76 | S&F PVC (SWR) bends for 75 mm bore pipes complete all as specified. |
| 77 | S&F PVC (SWR) bends for 110 mm bore pipes complete all as specified. |
| 78 | S&F 75 mm bore PVC (SWR) bends any radius with access door |
| 79 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided forcomplete all as specified and directed. |
| 80 | M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 81 | M&LPre cast RCC (1:2:4) type B1 for cover slab for man holes and set in cement mortar (1:6) complete all as specified and directed. |
| 82 | S&F Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 83 | S&F Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and incl rendering 20 mm thick on fair faces of brick work or concrete surfaces as backing coat in cement mortar 1:6 complete all as specified. |
| 84 | M&L Forming jambs, etc. to openings (to fore going item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:6, completeall as specified and directed. |
| 85 | M&L Making good under cills or over arches, lintels and bressummers. including allpinning when necessaryin ncement mortar 1:6 completeall as specified and directed. |
| 86 | M&L for Cement concrete tiles 30cm x 30cm x 25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished with grey cement and no pigment incl 20mm thick screed bed in cement mortar 1:6 completeall as specified and directed. |
| 87 | M&L for 75 mm thick, PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base, complete all as specified and directed. |
| 88 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 89 | M&L in replacement point wiring, concealed by using 1.5 Sqmm PVC insulated sheathed, FRLS, copper conductor multistrand drawn in suitable sunken box and frame cover plate for mounting of modular switches/sockets as required at site and provn of PVC rigid non metallic conduit medium density ISI marked fixed with all fittings and all accessories complete including cutting chasing to the existing surface to conceal the conduit and making good to the disturbed surface to match with the existing surface provision of 1.5 Sqmm PVC insulated, FRLS copper conductor continuos earth wire connected to common earth dolly including complete all as directed. |
| 90 | (a) One light/ fan point controlled by one switch / push button |
| 91 | (b) One 3 pin 5 Amps socket out let point on independent board. |
| 92 | All as per item no 89 above but with 4.00 Sqmm cable for one 3 pin 15Amps socket outlet point on independent board. |
| 93 | S&F in repair ceiling rose surface bakelite 65 x 50mm 3 terminals all as specified and as directed. |
| 94 | S&F switch piano, flush type single pole one way 5 Amps all as specified and as directed. |
| 95 | S&Fswitch socket combination 2 in 1, 3 pin, 6Amps all as specified and as directed. |
| 96 | S&F switch socket combination 2 in 1, 3 pin, 6 Amps and 16Amps flush type all as specified and as directed. |
| 97 | S&F in repair stepped type electronic fan regulator flush type ,230V, AC complete all as specified and as directed. |
| 98 | S&F sheet metal enclosure single pole and neutral, 240 volts, 8 way double door with 200 Amps rated bus bar including taking down old unserviceable DB / Main switch board complete all as specified and as directed. |
| 99 | S&F in repair MCB SPN 32 Amps, 240 volts \"C\" Curve complete all as specified and as directed. |
| 100 | S & F in repair MCB SP 5 to 32 Amps 240 volts \"C\" curve complete all as specified and as directed. |
| 101 | Material and labourin replacementof sub main wiring concealed type with two runs of single core, PVC insulated unsheathe multi-stranded copper conductor cable of size 6.00 Sqmm, 1100 volts grade (FRLS) and one run of 6.00 Sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as specified and directed. Note : two runs of 6.00 Sqmm cable, one run of 6.0 Sqmm continuity earth wire and one run of PVC non metalic conduit with all necessary accessories will be measured as one length. |
| 102 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal including taking down old earthing etc complete all as specified and as directed. |
| 103 | Supply and fixing in repair LED lights fitting 4 feet ,20 watts, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and directed by Engr-in-Charge. |
| 104 | S & F in repairs LED light fittings mirror type with high output diffuser 2 feet, 10 watts, 220 V, AC decorative box type with driver, holderincluding LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories all as specified and as directed. |
| 105 | S&F in repairs capacitor 2.5mfd for ceiling fan/exhaust fan complete all as specified and as directed. |
| 106 | S&F in repairs bearing no.6201/6202/6203 suitable forceiling fan/exhaust fan complete all as specified and as directed. |
| 107 | M&L for removing of burnt out winding wire from ceiling fan of any make and size of 1200mm to 1400mm sweep including cleaning of slots etc and rewinding with super enamelled copper wire as per existing size /gauge including insulating material,varnishing and drying complete all as specified and as directed. |
| 108 | M&L required for painting of ceiling fans complete,in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc.complete all as specified and as directed. |
| 109 | S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter , 230V 50 Hz,1200 rpm 300mm sweep with copper winding including drilling hole in walls for fixing of exhaust fan and making good wall surfaces if required complete all as specified and as directed. |
| 110 | S & F in repairs LED street light fittings 45 watts, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP65/66 protection complete with all accessories all as specified and as directed. |
| 111 | S&F in epair GI pipe bracket made of 40mm bore light grade pipe of overall length 1.2m made to shape for fixing of security light fitting including MS clamps ,nuts and bolts of required size complete all as specified and as directed |