Tender For Repairs To Rolling Shutters, Roof Sheets, False Ceiling, Valley Gutters,Damaged Security Wall, Area Drainage, Hard Standing, Footpath, Chainlink Fencing, Parking Shed, Gates And Misc Wks In At Wed, Saw Mill Nsd And Dsrv Under Ge (Nw) Mank, mankhurd-Maharashtra

Military Engineer Services-MES has published Tender For Repairs To Rolling Shutters, Roof Sheets, False Ceiling, Valley Gutters,Damaged Security Wall, Area Drainage, Hard Standing, Footpath, Chainlink Fencing, Parking Shed, Gates And Misc Wks In At Wed, Saw Mill Nsd And Dsrv Under Ge (Nw) Mank. Submission Date for this Tender is 20-04-2024. Raw Materials Processing Machinery Tenders in mankhurd Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43078954
Corrigendum : Tender For Repairs To Rolling Shutters, Roof Sheets, False Ceiling, Valley Gutters,Damaged Security Wall, Area Drainage, Hard Standing, Footpath, Chainlink Fencing, Parking Shed, Gates And Misc Wks In At Wed, Saw Mill Nsd And Dsrv Under Ge (Nw) Mank
Open Tender
Indian
Maharashtra
mankhurd
20-04-2024

Tender Details

Repairs To Rolling Shutters, Roof Sheets, False Ceiling, Valley Gutters,Damaged Security Wall, Area Drainage, Hard Standing, Footpath, Chainlink Fencing, Parking Shed, Gates And Misc Wks In At Wed, Saw Mill Nsd And Dsrv Under Ge (Nw) Mankhurd

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Apr-2024 AMENDMENT Other 20-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 95000.0 /-
Tender Value
INR 47.50 Lakhs /-

BOQ Items

NAME OF WORK : REPAIRS TO ROLLING SHUTTERS, ROOF SHEETS, FALSE CEILING, VALLEY GUTTERS,DAMAGED PERIMETER SECURITY WALL, AREA DRAINAGE, HARD STANDING, FOOTPATH, CHAINLINK FENCING, PAVEMENT, PARKING SHED, GATES AND CERTAIN MISC WORKS IN OTM AND MD ACCN AT WED, SAW MILLNSD MANKHURD AND DSRV UNDER GE (NW) MANKHURD
Sl. No. Item Description
1Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings as specified
2S&F Pre- painted galvalume sheet having aluminum zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by usingproper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fastners etc. completely all as specified and directed. upto maximum height of 20 Mtr including scaffolding and all safety equipments as required. Note : No additional payment on any account will be considered and only plan area whatever have been provided will be measured. Rate quoted maybe considered including of bending for specific curvature as provided in existing building.
3S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet in ridge 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified upto maximum height of 20 Mtr including scaffolding and all safety equipments if required. Note : No additional payment on any account will be considered and only plan area whatever have been provided will be measured. Rate quoted maybe considered including of bending for specific curvature as provided in existing building.
4Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc and removing debris outside MD land complete all as specified
5M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified
6M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty onold surfaces of wallsetc, finished even and smooth, complete all as specified and directed.
7M&L for rendering 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
8M&L for rendering 15mm thick in two coats (10+5mm) Cement plaster in CM 1:3 on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed
9M&L for rendering 10mm thick Cement plaster in CM 1:3 on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed
10M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 16 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner" of "Pidilite" OR "Shali Rustoff" of "STP Ltd", on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcementusing Corroseal - ZR of M/s Krishna Conchem orEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchemas approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete& new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers,each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
11M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 10 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner" of "Pidilite" OR "Shali Rustoff" of "STP Ltd", on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcementusing Corroseal - ZR of M/s Krishna Conchem orEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchemas approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete& new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers,each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty onold surfaces of wallsetc, finished even and smooth, complete all as specified and directed.
12M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 10 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner" of "Pidilite" OR "Shali Rustoff" of "STP Ltd", on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcementusing Corroseal - ZR of M/s Krishna Conchem orEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchemas approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete& new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers,each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
13M&L for providing CRS TMT bars any dia in various structural RCC elements like columns, beams, Slabs etc. including cutting, bending, fixing of bars with welding/ tying as required at site with & including binding wires etc. and all relevant works like anchoring of the bars in the existing RCC Members, complete all as specified and directed.
14Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc
15M&L Vitrified Coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
16Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
17Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs complete all as specified and directed by EIC.
18Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
19Glazed ceramic coloured tiles in vertical surface 300x 450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match (dado) including 10 mm thick back coat of cement plaster on fair faces of brick work 1:3
20S&F uPVC vent cowl 110mm bore with and including rubber ring joints, complete all as specified and directed.
21S&F uPVC vent cowl 75 mm bore with and including rubber ring joints, complete all as specified and directed.
22S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls all complete all as specified and directed.
23S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal with access door
24S&F 110mm bore PVC (SWR) bend with access door
25S & F in repairs PVC (SWR) bend 75 mm with access door
26S & F in repairs PVC (SWR) bend 75 mm without access door
27S & F in repairsPVC (SWR) bend 110 mm with access doors
28S & F in repairsPVC (SWR) bend 110 mm withoutaccess doors
29S & F in repairsPVC (SWR) branch piece, single (single Y) equal or unequal,75 mm
30S & F in repairsPVC (SWR) branch piece, single (single Y) equal or unequal,75 mm with access door
31S & F in repairsPVC (SWR) branch piece, single (single Y) equal or unequal,110mm
32S & F in repairsPVC (SWR) branch piece, single (single Y) equal or unequal,110mm with access door
33S & F in repairsPVC (SWR) branch piece, double (double Y) equal or unequal,75 mm
34S & F in repairsPVC (SWR) branch piece, double (double Y) equal or unequal,75 mm with access door
35S & F in repairsPVC (SWR) branch piece, double (double Y) equal or unequal,110mm
36S & F in repairsPVC (SWR) branch piece, double (double Y) equal or unequal,110mm with access door
37S & F in repairs 40 mm bore PVC pipes single socketed in any length jointed and fixed to walls and floors for spouts, washbasin outlet
38S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white with integral foot rests with flush pipe of 32mm dia including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
39S&F vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia pillar tap, CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.in repair
40S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern)including 10 ltr capacity low level flushing cistern with flush pipe of 32mm dia including necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
41Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm and Supply & fixing 15 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
42Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
43Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
44Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40mm complete all as specified and directed.
45Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25 mm complete all as specified and directed.
46S&F Unplasticised PVC pipes of 15mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
47S&F in repairs 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, of suitable length as per site requirement connecting to WC etc, and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
48S&F in repairs CP stop cock 15mm borefancy type chromium plated with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
49S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwedfor iron pipe or for unions and fixed complete all as specified and directed.
50S&F in repairs CP pillar taps 15mm bore, cast copper alloy, chromium plated fancy type complete all as specified and directed.
51S&F in repairs waste fitting of 32 mm borebrass, chromium plated for glazed ware wash basin etc complete all as specified and directed.
52S&F in repairs waste fitting of 40 mm borebrass , chromium plated for glazed ware for sink coulpling etc complete all as specified and directed.
53S&F in repairs waste pipe for WHB 32mm bore fixed to wash hand basin coupling length pipe 0.90 mtrs each complete all as specified and directed.
54S&F in repairs waste pipe for kitchen sink 40mm bore fixed to sinks coupling length pipe 0.90 mtrs each complete all as specified and directed.
55S&F in repairs stainless steel grating in round shape 100mm dia with one hole for waste pipe complete all as specified and directed.
56S&Fin repairsstainless steel grating in ground shape 100mm dia without hole complete all as specified and directed.
57S&F GI Tubes 15mm bore, "medium grade" galvanised,with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
58S&F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
59S&F in repairs Health faucet with 1 mtr tube & hook complete all as specified and directed.
60S&F in repairs two way Bib cock long body with wall flange fitted by 15mm bore complete all as specified and as directed
61S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
62S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 495mmx420mm bowl size 410mmx330mmx160mm complete iincluding demolition of old cudappah sink/old sink all as specified and as directed.
63Supply & fixing 20mm CPVC pipes UV stable,leak proof, tough ,rigid , conforming to IS:15778 of SDR 11 standard., medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
64Supply & fixing 40 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
65Supply & fixing 25 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
66S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20mm bore complete all as specified and directed.
67S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 15 mm bore complete all as specified and directed.
68Taking down chowkhat or frame (without taking off shutter from the frame)not exceeding 1.5 Square Metre each , removing from the site including cutting holes required fortaking out existing hold fast etc. complete all as specified and as directed.
69All as per Item No 68 above butexceeding 1.5 Square Metre and not exceeding 04 Square Metre each complete all as specifiedand directed.
70Solid PVC Door Frame of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
71M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame madeout of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2020 complete all as specified and directed
72Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account will be provided
73Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
74M & L for 20 to 25mm machine cut,polished cudappah stone slab, , in window cill, kitchen platform and similar work,laid over and including backing coat, in CM 1:4, 15mm thick,jointed with grey cement slurry mixed with pigment to match the shade of the slab including taking down/dismantling old one complete all as specified and as directed
75M&L Granite (of any type) Tiles 20mm thick in floormachine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 20mm thick CM 1:6 screed bed for laying floor finishes and cutting andpolishingcomplete all as specified and as directed.
76Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
77Taking down carefully existing aluminium sliding window shutters,(glass/wire mesh) /frame not exceeding 1.5 Square Metre each and re-fixing the shutters in existing position, after repairing complete all as specifiedand directed.
78All as per Item No 77 above butexceeding 1.5 Square Metre and not exceeding 04 Square Metre.
79S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only.Fixing by element of these items shall be deemed to be included in quoted rate.
80S&F for 4.80mm thick glass ordinary quality plain withincluding wooden/rubber beading or gasket for aluminium sectioncomplete all as specified
81S&F for 3.0mm thick pin head glass withincluding wooden/rubber beading or gasket for aluminium sectioncomplete all as specified
82S&Faluminum anodised grill DG- 104 of Deco grill or equivalent fixed with "F"/"U" section approved make all as specified and directed. Note : (i)Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
83Supply only stainless steel wire cloth,0.36 mm nominal dia ofwire and average width ofaperture 1.40mm and fixed with in wooden windows, doors etc and including M&L for fixing of teak wooden beading of suitable size all around complete all as specified and as directed by the Engineer-in-Charge.
84Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
85Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.(Any Size/Capacity)
86Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc to a distance exceeding 500m and not exceeding 1.0km complete all as specified and directed by the Engineer-in-charge
87M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in leveling course over RCC roof/ terrace surfaces to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC(water proofing compound) as per manufacturer"s instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately as "supply only".
88Supply only Integral waterproofing compound.
89i) M&L for preparation of surface including cleaning of all dirts and provide the following water proofing treatment in Accessible Roof/Inaccessible Roof & terrace, narrow width over the roof gutter of store houses or chajjas etc. ii)Apply oil boundbitumenprimer @ 0.25 gm/Sqm manufacturerby thesameagency as that of APPwithdensityof 0.87-0-89 Kglitr at 25 c on the prepareddry roofsurface provideand layAPPmodified water proofingmembrancereinforced with nonwoovenpolystermatt with physicalproperties as under :- (aa)Membrane Weight -not less than 3.0 Kg/Sqm (ab)Non woven polyster weight-160 gm /Sqm (ac)Joint Tensile strength Longiutinal-650 N/Sqcm Tranverseand longitudnal-350/Sqcm (ad) Tear strength Longiutinal-300N /cm Tranverse -250N/cm Direction (ae)Impermeability underwater pressure 2Kgf/Sqcm (iii)APP membraneshallbe laidusing butaretorch by Torchon applicationwith minimum 10cmside overlapand 15cmend lap. Thelaying of membranceshall begot, donethroughan authroiset applicate of Manufacture of membrane. (iv)Over the membrane provide a finishingwith solar reflectivebitumenaluminium to inaccesible roof. paint@ 0.10 Kg/Sqm as prescribed by manufacturer
90M&L for preparation of old plastered surfaces on walls, preparation for Acrylic emulsion and applying applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
91M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
92M&L for Complete removal of existing treatment and preparation of plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
93M & L for preparation of old distempering surfaces including stopping of nails holes,cracks etc. and applying one coat of oil bound distemper on wall complete all as specified.
94Preparation of old surfaces on ceiling (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
95Preparation of old surfaces on wall (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
96M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
97M & L for preparation of old steel surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
98M & L for preparation of old steel surfaces of any description over 10cm width or girth & applying one coat of aluminium paint complete all as specified.
99M&L for preparation of old painted surfaces of anydescriptionand applying one coat of cement base paint on wall with necessary scaffolding arrangement. Note: The contractor shall clean the window panes including splashes of paint etc and the quoted rate is deemed to be included for the same.
100M&L for formingV groovesin plaster n exc 5mm deep and n exc 5 mm on face and filling crackswith crack X paste of M/s Dr fixit or with eequivalent of M/s STP Ltd including necessary scaffolding
101M&L for formingV groovesin plasterexc 5mm deep andexc 5 mm on face and filling crackswith cement mixed with M/s Dr fixit or equivalent of M/s STP Ltd including necessary scaffolding
102M&L for providing leakage/seepage proof coating by applyingprimeseal primer of Dr fixit or equivalent of M/s STP Ltd under torch dry condiiton and subsequently applying two coats of water proof decorative elastomeric coating system rain coat select system of M/s Dr fixit or equivalent of M/s STP Ltd over prepared surfaces including necessary scaffoldingNote The afore said treatment shall be got executed by the contractor frpom authorised applicator of the manufacturer and also necessary documents in support of the above shall be submitted by the contractor complete all as specified and directed.
103M&L for dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
104S&F Anodised aluminium snap grid frame work for false ceiling all as specified fixed using Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
105Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions
106Dismantling fencing wire mesh, any type
107Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
108S & F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E 165
109S&F 1.0mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 with welded or soldered joints. Note: A sum of Rs 74,391.00 towards sch of credit shall be deducted to arrive the contract sum