Repair / Maintenance To Lt Network System , Lt Panels Andallied Works And Repair Maintenance Of External Water Supply , Pipelines, Filteration Plant, Control Valves, Pump Sets And Allied Works At Averipatti Under Age E / M ( We ) Pooh In Ge 863 Ews., Kinnaur-Himachal Pradesh

Military Engineer Services-MES has published Repair / Maintenance To Lt Network System , Lt Panels Andallied Works And Repair Maintenance Of External Water Supply , Pipelines, Filteration Plant, Control Valves, Pump Sets And Allied Works At Averipatti Under Age E / M ( We ) Pooh In Ge 863 Ews.. Submission Date for this Tender is 20-04-2024. Electrical Panel Tenders in Kinnaur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43078922
Repair / Maintenance To Lt Network System , Lt Panels Andallied Works And Repair Maintenance Of External Water Supply , Pipelines, Filteration Plant, Control Valves, Pump Sets And Allied Works At Averipatti Under Age E / M ( We ) Pooh In Ge 863 Ews.
Open Tender
Indian
Himachal Pradesh
Kinnaur
20-04-2024

Tender Details

Repair / Maintenance To Lt Network System , Lt Panels Andallied Works And Repair Maintenance Of External Water Supply , Pipelines, Filteration Plant, Control Valves, Pump Sets And Allied Works At Averipatti Under Age E / M ( We ) Pooh In Ge 863 Ews.

Key Value

Document Fees
INR 50 /-
EMD
INR 64000.0 /-
Tender Value
INR 32 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINTENANCE TO LT NETWORK SYSTEM , LT PANELS ANDALLIED WORKS AND REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY ,PIPELINES,FILTERATION PLANT,CONTROL VALVES,PUMP SETS AND ALLIED WORKS AT AVERIPATTI UNDER AGE E/M (WE) POOH IN GE 863 EWS.
Sl. No. Item Description
1M & L GI tubing medium grade of size 80 mm boreincluding all fitting such as bend, Tee, union, socket etc in trenches complete all as specified and directed.
2All as per item serial No 1 here in before but of 50 mm dia
3All as per item serial No 1 here in before but of 40 mm dia
4All as per item serial No 1 here in before but of 25 mm dia
5All as per item serial No 1 here in before but of 20 mm dia
6All as per item serial No 1 here in before but of 15 mm dia
7All as per item serial No 1 here in before but of 100 mm dia
8Supply and lay pipe ductile Iron in trenches/floor, Class “K-7” , socket and spigot type, 100 mm dia including suitable tyton rubber rings as required complete all as specified and directed.
9Taking down old unserviceable damaged CI/GI pipe of 100/80 mm size from excavated trenches or from wall/floor and removal to store or stack asidecomplete all as specified and directed.
10All as per item serial No 9 here in before but of 50/40 mmbore
11All as per item serial No 9 here in before but of 25 mm bore
12All as per item serial No 9 here in before but of 20 mmbore
13All as per item serial No 9 here in before but of 15 mmbore
14Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying pipes/repair to pipes and sluice/control valves etc. complete all as specified and directed.
15Returning refiling in, including spreading, leveling watering and well raming in layers each not exceeding 25 cm thickness complete all as specified and directed.
16Removing surplus soil to a distance not exceeding 50 mtr and deposting wheredirected at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
17Material and labour forcleaning of sedimentation tank of size 6.92m X 4.07m X 2.5m, draining/washing out complete through wash out pipe, and removing all mud, silt, scales, dirts etc from inside area and cleaningwith bleaching powder, wire brush, broom and sand paper etc and marking date ofcleaning and capacity of tank with synthetic enamel paint complete all as specifiedand directed
18All as per item no. 17 here-in-before, but cleaning of filteration tank of size 7.0m X 4.75m X 4.5m.
19M & L for dewatering from semi under ground sump 10000 Glns capacity, cleaning internal walls, bottom surface of sump by removing scales and other foreign materials, scrubbing with water using coir jute brushes, washing the surfaces with mixture of bleaching powder and water & finally washing with fresh water on walls, bottom surface etc applying two coats of white wash inside and outside as existing colour wash and writing letters on the wall i.e. capacity of tank, Date of cleaning, Due date for next cleaning, etc with synthetic enamel paint complete as specified and directed
20Supply and fix in replacement Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 80 mm dia complete all as specified and directedMake : Zoloto/Bir/Leader
21All as per item No 20 above but for 50mm dia
22All as per item No 20 above but for 40mm dia
23All as per item No 20 above but for 25mm dia
24All as per item No 20 above but for 20mm dia
25S & F in replacement sluice valve 150 mm dia with stainless steel spindle complete assembly, class PN 1.0, ISI marked including providing rubber gaskets, nut & bolts, washers, etc complete all as specified and directed
26All as per item serial No 25 here in before but of 100 mm dia
27M & L in replacement Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for S/S pipes upto 150 mm dia complete all as specified and directed
28M&L for PCC 1:3:6type C-2using 40mm graded stone aggregate for coping, parapit, thrust blockand other similar items complete all as specified and directed.
29M & L for fabrication includingwelding and fixing in replacement of valve chamber cover made out of 3mm thick MS sheet duly supported by MS flat 25 X 4mm all around and diagonal for various sizes valves chambers duly fixed with 25X4mm flat and long split at one end embedded in wall and lifting handle of MS flat with suitable size and welded to MS sheet with and incl locking arrangement and painted with approved quality of two coats of enamelled paint over a coat of metalic primer complete all as specified and directed by Engineer-in Charge.
30Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
31M & L for brick work with subclass "B" bricks, straight or curved on plan n exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed
32M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement plaster to be finished even and smooth without using extra lime or cement complete all as specified and directed
33M & L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed
34M & L for PCC 1:3:6type C2 (using 40mm graded aggregate) in foundation, filling and mass concrete
35M&L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip25x4 mm dia up to 7.5 meter from earth pit, protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel , common salt, charcoal dust and connected to panel board by means of bolts and nuts washers made out of GI, all as shown in Electrical plate No 5 of SSR part I includingnecessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed
36Taking out faulty U/G cable of any size by removing PCC covers or bricks of any specification for replacingthe same withnewLT U/G cable all specified and as directed
37Supply, laying LT UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sq mm 3.5 core as per IS specifications complete all as specified and directed
38All as per ser item No37 here in before but of 50 Sqmm 3.5 core
39All as per ser item No37here in before but of 35 Sqmm 3.5 core
40All as per ser item No 37here in before but of 25 Sqmm 4 core
41All as per ser item No 37 here in before but of 16 Sqmm 4 core
42All as per ser item No 37 here in before but of 10 Sqmm 2 core
43M & L for Sand cushioning on under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed
44Supply and lay well burntclass ‘B’ bricks as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench all as specified and directed
45Supply and laying in replacement ofGI pipe light grade galvanizedwith all fittings laid in trenches for cable protection of 80 mm bore all as specified and directed
46All as per item serial No 15 above but of 50mm dia
47Supply, fix in replacement of MCCB 400 Amps, 4 Pole 415 V, Adjustable type with breaking capacity 36 KA with spreader links, etc complete all as specified and directed
48All as per ser item No 50 here in before but ofMCCB 250 Amps, 4 Pole 415 V with breaking capacity 36 KA
49All as per ser item No 50 here in before but ofMCCB 200 Amps, 4 Pole 415 V with breaking capacity 36 KA
50All as per ser item No 50 here in before but of MCCB 160 Amps, 4 Pole 415 V with breaking capacity 25 KA
51All as per ser item No 50here in before but ofMCCB 100 Amps, 4 Pole 415 V, fixed type with breaking capacity 16 KA
52All as per ser item No 50 here in before but ofMCCB 63 Amps, 4 Pole 415 V with breaking capacity 16 KA
53Supply and errection in replacement of steel tubular swaged pole 09 M long type 410-SP-31 complete with CI base plate, finial taper plug, bolts, nuts and screws etc includingcomplete all as specified and directedNote : Necessary excavation and earth work, PCC foundation, coping, disposal of surplus soil, Painting inside with black bitumen paint and out side shall be measured and paid separately on relevant items of Sch "A"
54M&L Restringing only ACSR conductor of any type/ size on existing LT poles, etc including binding on to insulators with and including aluminium wire complete all as specified and directed .
55Supply and stringing ACSR conductor of any size in accrodance with site requirement and binding on insulators by means of aluminium binding wire tapes all as specified and directed
56S & F in replacement of pin type, porcelain vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65mm dia for 1100 Volts grade complete all as specified and directed.
57S & F in replacement of shackletype porecelain vitreous white brown or green insulator for working pressure 1100 volts of 90mm dia and 75mm height incl galvanised steel straps of 31x3 mm size, insulator bolt 12 mm dia,washer & nuts complete all as specified and directed.
58S & F in replacement of PVC line phase separators for over headline LT conductor of any size suitable to withstand 1100 volts to maintain the required spacing between 3 conductors complete all as per site requirement and all asdirected
59All as per Srl Item No 61above but suitable for 2 wire.
60M&L in replacement of cross arms bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts, washers welding, bending cold or hot drilling holes for bolts, washers in any shape or size as indicated or directed incl one primer coat, one under coat & and one finishing coat complete all as specified & directed.
61S & F in replacement of Stay assembly Diameter ofstay rod of not less than 20 mm, 215cm long with threaded end with suitable size of nuts & washers complete with accessories including staybowswith nut bolt & washer of 14mm dia, 40cm long and stay grips & thimble of suitable sizeas shown in electrical plate No. 1 SSR Part-I complete all as specified and directed. Note:(i) Rate are deemed to be inclusive of streching, tieing and tightening of stay assembly for poles including tieing frame for stay wire. (ii) Exacavation, returning filling, removal for stay wire assembly upto 2.5 mtrs including Ropes are deemed to be included in quoted rates. (iii) Ladders of any size,T&P (any type), Labour Safety equipments as required at site for working on PCC pole of 9Mtrs height is deemed to be inclusive of quoted rates. (iv) Stay clamp/stay wire will be measured & paid saperately.
62S&F in replacement Loop type insulator, vitreous porcelain, white, brown or green of Large size, with overall dimensions 140mm, clearance of hole 25.5mm, including nut bolts & washers of suitable length and thickness, complete all as specified and directed.
63M&L in repair galvanised stay wire 7/4mm for stay assembly to be fixed between stay assembly and stay clamp on PCC/MS steel pole, complete all as specified and directed.
64M & L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary .
65M & L for PCC 1:3:6type C2 (using 40mm graded aggregate) in foundation, filling and mass concrete
66M & L for Aluminium paintingto Steel tubular Street light pole for 5.5 mtr from top towards bottomand next 0.45 mtr Navy Blue and next 1.10 mtr white and 0.45 mtr Synthetic enameld paint yellow & black colour(Tiger cross) on Coping and writing pole No with white paint inside of black circle above the Navy blue painting and aluminium painting to GI bracket / pipe etc.and sticking of reflector stricker red in colour on the Poles at the height of 1.5metre above the copping and all as specified andand as directed.
67Supply and fixing in replacement ofBusbar chamber 200 Amp with suitable thickness aluminium busbars, 8 way, 415 volts, 50 Hz, Wall mounted type incliuding suitable fastners, etc complete all as specified and directedMake : Havells/L&T/Standard
68Supply, installation, testing and commissioning , LT panel board, 415 Volts, 4 wire, AC 50 Hz, factroy made, outdoor pedestal type,double door type (openable front and back), weather and vermin proof, fabricated of 3.15 mm thick CRCA sheet, confirming to Latest IS 8623(CPRI Approved), powder coated RAL-7032 with seven tank Pre-treatment and outside locking arrangement, two earth terminal, and cable glands for all incoming and outgoing cables including grouting of LT panel45cm above ground level by providing 90cm long iron angle of size 50x50x6mm welded on all four corners embeded in PCC 1:2:4 using 20mm stone aggregate upto 45cm grouted in ground and 15cm above ground for coping including taking down unsv outdoor LT panel any type with MCCBs after disconnecting the electric supply complete all as specified and directedincluding the following components :-Four Nos of aluminium bus bars of high conductivity, 3 Nos for phase (RYB) and one No for neutral of current rating 375 Amps mounted on porcelain support.Incoming : MCCB 250 Amps, adjustable type, 36 KA four pole 415 volts- 01 NoOutgoing : MCCB 200 Amps, adjustable type, 36 KA four pole, 415 volts- 01 No.Outgoing : MCB 63 Amps, 10 KA,two pole, 230 volts- 02 Nos. Digital type display multi function meter with the parameters like Volts, Amps, Frequency, Power factor, suitable CT & PT, etc - 01 No.LED indication lamp RYB Set of three - 01 No.
69Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail