| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fitting fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified and as directed. |
| 2 | Taking down the unserviceable submain wiring of any type/ description as existing at site including making good the disturbed surfaces tomatch withthe existing finishes complete all as directed. |
| 3 | Material and labour for attending complaints i.e no light, earth leakage, short circuit, neutral breakmains/ sub mains/ internal circuits of existing system of main building/ block, making continious electric supply including carrying out minor repairs etc as required to make the system in order/ functional including replacing fuse wire, copper cable, copper thimbles, glands, earthing wire complete all as specified and as directed. Note :- Cost of fuse wire, copper thimbles, glands, earthing wire are deemed to be included in quoted rate. |
| 4 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts gradeISI-694 marked drawn through in and including heavy duty, PVC concealed conduitincluding all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches,including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- |
| 5 | (a) One light / fancontrolled by one switch one way. |
| 6 | (b) One light point controlled by two 2 way switch. |
| 7 | (c)Socket outlet 05 Amp on same board. |
| 8 | (d) Socket outlet 05 Amp on independent board. |
| 9 | (e)One bell /buzzer point controlled by one bell push |
| 10 | All as per item No 04 point wiring with 2.5 Sqmmsingle core coppercable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board. |
| 11 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc,heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, sockets, regulators including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- |
| 12 | (a) One light / fancontrolled by one switch one way. |
| 13 | (b)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 14 | (c) One bell point controlled by one, bell switch 5 Amps |
| 15 | (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 16 | (e)point wiring for One light point controlled by two 2 way switch. |
| 17 | All as per Item No. 6 above but with multistranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 markedfor 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly. |
| 18 | S&F modular switch 01 way 6 Amp , 01 module ISI marked complete |
| 19 | S&F modular switch 01 way 16 Amp , 01 module ISI marked complete |
| 20 | S&F modular switch 02 way 6 Amp , 01 module ISI marked complete |
| 21 | M&L for Modular bell push 6 amp 230 volt 50 hz AC supply one way, completeall as specified |
| 22 | S&F modularsocket 6 Amp , 2 moduleISI marked complete |
| 23 | S&F modularsocket 6 / 16 Amp ,02 in 01 ,02 moduleISI marked complete |
| 24 | S&F for modular step fan regulator 120 watt 2 module suitable for 230 Volt 50 Hzsupplyall as specified |
| 25 | Supply & fix CALL BellISI marked complete |
| 26 | S&F ceiling rose surface Bakelite 3 terminals 230V 50 Hz ISI marked. |
| 27 | S&F forLamp holder, PVC/ Polycarbonate type with back plate suitable for angle/batten fitting completes all as specified. |
| 28 | Material and labour for sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable with multistranded FRLS copper conductor of size 4.0 Sq. mm nominal area and drawing through and including 20mm dia heavy dutynon metallic rigid PVC conduit of white/ ivory colour and conduit accessories, ISI marked including one run ofPVC insulated 4.0 Sqmm (nominal area) multistranded FRLS copper conductor as earth wire complete all as specified and as directed. (Note- Two runs of 4.0 Sqmm main cable, one run of 4 Sqmm earth conductor and one run of PVC conduit will be measured as one unit) |
| 29 | All as per item No 18but Submain wiring with2 runs of6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor. |
| 30 | All as per item No 18 but Submain wiring with4 runs of6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor. |
| 31 | S & F in repair for VTPN DB Phase segregated double door vertical type 6 way 415 volts, 50Hz suitable for MCCB incommer IP 43 protection provided with insulated vertical phase busbars, blanking plates and circuit identification labels, double door with locking system including necessary provision for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wallcomplete all as specified and as directed.Make: C&S Cat Part No CSDBMCCB125PDDD08S or in equavalent in Legrand, Schneider, ABB, L&T |
| 32 | S & F in repairfor VTPN DB Phase segregated double door vertical type 4 way 415 volts, 50Hz suitable for MCCB incommer IP 43 protection provided with insulated vertical phase busbars, blanking plates and circuit identification labels, double door with locking system including necessary provision for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make: C&S Cat Part No CSDBMCCB125PDDD04S or in equavalent in Legrand, Schneider, ABB, L&T |
| 33 | S & F in repair for sheet metal enclosure MCBDBTPN415 volts, IP 43 of 4 way made of CRCA sheet steel, powder coated provided with insulated phase busbars, neutral bar,shrouds, earth bars, cable ties, blanking plates and circuit identification labels with necessary electrical connection,double door with locking system includingcement work for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make: L&T Cat Part No DBTPE004DD or in equavalent in Legrand, C & S,ABB, Schneider |
| 34 | S & F in repair for sheet metal enclosure MCBDBSPN4 way 230 volts, IP 43 made of CRCA sheet steel, powder coated provided with insulated phase busbars, neutral bar,shrouds, earth bars, blanking plates and circuit identification labels with necessary cement work and electrical connection,double door with locking system including necessary provision for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall or mounting on surface complete all as specified and as directed. Make: L&T Cat Part No DBSPN004DD or in equavalent in Legrand, C & S, Schneider, ABB |
| 35 | S & F in repair for sheet metal enclosure MCBDBSPN8 way 230 volts, IP 43 made of CRCA sheet steel, powder coated provided with insulated phase busbars, neutral bar,shrouds, earth bars, blanking plates and circuit identification labels with necessary cement work and electrical connection,double door with locking system including necessary provision for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall or mounting on surface complete all as specified and as directed. Make: L&T Cat Part No DBSPN008DD or in equavalent in Legrand, C & S, Schneider, ABB |
| 36 | S & F in repair for sheet metal enclosure MCBDBSPN12 way 230 volts, IP 43 made of CRCA sheet steel, powder coated provided with insulated phase busbars, neutral bar,shrouds, earth bars, blanking plates and circuit identification labels with necessary cement work and electrical connection,double door with locking system including necessary provision for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall or mounting on surface complete all as specified and as directed. Make: L&T Cat Part No DBSPN012DD or in equavalent in Legrand, C & S, Schneider, ABB |
| 37 | S & F MCCBFP415volts of Breaking Capacity 25 kA with Thermal Magnetic Release without enclosure suitable for fixing on DB of capacity 100Amps with extended terminals complete all as specified.L&T/C & S/Schneider/ABB/Havells |
| 38 | S & FforMCB TPN rated capacity 63 Amps, 415 Volts breaking capacity 10 KA complete all as specified and as directed. L&T/Legrand/C & S/Schneider/ABB/Indo Asian/Havells |
| 39 | Supply and fix for MCB SPN rated capacity 32 A, 240 V breaking capacity 10 KA complete all as specified and as directed.L&T/C & S/Schneider/ABB/Havells |
| 40 | Supply and fix for MCB SP rated capacity 5 to 32 A, 240 V breaking capacity 10 KA complete all as specified and as directed. L&T/C & S/Schneider/ABB/Havells |
| 41 | S & F in repair forLED 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make- Bajaj Cat Part No BCLSB 10 NW or its equivallent model in JAQUAR,PHILIPS. |
| 42 | Supply and fixin repair for wall mounted LED 20watts with lumens out put not less than 2000 lumens, boxtype (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driverconnector block etc complete with all accessories internally pre wiredandnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4\" x 20watts complete all as specified and as directed. Make: Bajaj Cat No. BCLAB 20W, JAQUAR Cat part No LGLZ01X020XN or equvalent of make Philips/ HALONIX as approved. |
| 43 | S & F in repair for wall mounted 20 watts indoor Inverter batten with opal diffuser, IP 20, with 4 hrs back up with out put of 1800 lumens , boxtype (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4\" x 18 watts complete all as specified and as directed. Make :- Halonix Cat part No.LED INVERTER BATTEN HLB-08-20-CW-INV or equivalentPhilips |
| 44 | S & F in repair for wall mounted 10 watts outdoor Inverter LED Bulk head fiting, IP 65, with battery back up and functioning as per TDS,230 volts with connector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb 10 watts complete all as specified and as directed. Make :- Halonix Cat part No.HLBH-15-10CW-INV or equivalentPhilips, Havells. |
| 45 | S & F in repair for recess mounted 2\" x 2\" luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free sift illumination square LED panel 36 watts, white powder coated CRCA housing with full window acrylic diffuser giving a complete full glow look, operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make-JAQUAR Ultima Ultra Cat Part No LULTU1S036XC or its equivalent in Havells/ Philips |
| 46 | S & F in repair for recess mounted square LED panel 18 watts, IP 20, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- Halonix HLFPR11-02-18-CW, Jaquar LNEP01S024XN, Phillips SM200C LED115 6500 PSU OD WH/shakti. |
| 47 | S & Fin repair forLED downlight surface mounted luminare round type 12 watts with inbult driver and polycarbonate opal diffuser white finish operating voltage 230V AC, 50 Hz including taking down old unserviceablefittingcomplete all as directed Make :-Jaquar LNVE02R012SN , philips/ Havells/Halonix |
| 48 | S & Fin repair wall mounted LED 3/6 watts bed side lamp with necessaryelectrical connections complete all as specified and as directed. |
| 49 | S & Fin repair wall mounted LED 3/6 watts PICTURE Lightflexible and adjustable to any direction with necessaryelectrical connections complete all as specified and as directed. Make: Philips, Havells, Jaguar, lukar |
| 50 | Supply and fixin repair for energy saving new generation 10 watts LED bulk head fitting ,230 volts with connector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor from ceiling rose to fitting complete all as specified and as directed. Make :- PHILIPS/JAQUAR Cat No.CWLL01V109XX 10W/Halonix/Bajaj/HAVELLS |
| 51 | Supply & fixin repair energy saving 05 watt LED Spot light fitting flexible and adjustable to any direction with integeral electronic driver complete with all accessories. |
| 52 | S & F in repair for recess mounted 1\" x 4\" rectangular LED panel 36 watts, sleek design , polycarbibate diffuser operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- BAJAJ , HAVELLS |
| 53 | S & F inrepair for Decorative wall mounted luminaire with opal glass with E27 lamp holder complete all as specified and as directed. Make-Jaquar Cat part No - JNL-CHR-WLSL-55004E27 , havells FLORETTE 1LS E27 SS,HALONIX HHW048 08CF RF |
| 54 | Supply and fix in repairLED Lamp warm white/ amber 5 Watt highly efficient of make Havells /Bajaj/Philips all as specified and as directed. |
| 55 | S/Fin repair LED street light fitting 30 Watt 230V energy efficient & environment friendly type. The fitting should have powder coated, pressure die cast Aluminium housing and heat resistant toughened glass with frame having better optics for uniform distribution complete all as per MakeJAQUAR or equivalent of make Bajaj, Philips,Havells, Halonixas approved. |
| 56 | Supply and replace for single core cable PVC insulated and unsheathed multistranded copper conductor of following size from point wiring/Submain wiring including removal old existing unserviceable one complete all as specified and directed. |
| 57 | (a) 1.5 Sq mm |
| 58 | (b) 2.5 Sq mm |
| 59 | Supply and fix for casing and cappingheavy duty, size 20mm with all fittings including removal of old unserviceable one complete all as specified and as directed |
| 60 | Supply and replace for rigit PVC conduit 20mm dia. heavy duty of white/ ivory colour with all accessoriesand making good the disturbed seurfaces for laying of telephone cable complete including removal old existing unserviceable all as directed |
| 61 | Supply and fixMCB Protected SRCD box 4 module 25 Amps with surface mounted PVC enclosure SRCD(socket residual current device) single pole with a three pin socket & top complete with 25 Amps MCB single pole. Make: Havells Cat part No DHDTCSN0251020 OR Equivalent C&S/Indo Asian/L&T/Bajaj/Legrand |
| 62 | Supply and fix for sheet metal enclosures single pole and neutral with a three pin earth plug and socket complete with one MCB SP 20/ 32Ampscomplete all as specified and as directed. Make: Havells,C&S/Indo Asian/L&T/ABB/Legrand |
| 63 | Supply and fix in repair for Ceiling Fan of sweep size 1200 mm BEE. Five star rated with brushless direct current motor (BLDC) ?, ISI marked and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. Make:- Bajaj , USHA , Havells, Orient |
| 64 | Supply and fix in repair for Ceiling Fan of sweep size 1400 mm BEE. Five star rated with brushless direct current motor (BLDC) ?, ISI marked and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. Make:- Bajaj , USHA , Havells, Orient |
| 65 | Supply and fix in repair for wall mounted fan of size 400 mm sweep BEE.ISI marked and connecting up includingcomplete all as specified and directed. Note : a) Quoted Rate is deemed to inclusive of Stickering/Marking/writing of MES numbers in bottom of ceiling Fan as directed by Engr-in-Charge. Make:- Bajaj , USHA , Havells . |
| 66 | Supply and install in repair for pedestial fan of size 400 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed. Make- Crompton Model High Flo,Bajaj Midea BP 2200, or its equivallent model in Havells, Usha. |
| 67 | Supply,installation,testing and commissioning of ceiling mount auto light occupancy, dual technology sensor,adjustable of delay timer, infra red and ultrasonic detection,Dia 8meters IP 20, 3 wire with neutral optimum distance between 2 sensors should be 6 Mtr, stand by consumption 0.8W, fixed directly to a false ceiling with mounting claws (included) or installed in a battibox depth 50 mm all as specified and directed. Note:- All necessary FRLSH copper wires to connect complete lights of office bldg/OR living/Messes etc are deemed to be included in the rates quoted above for motion sensors. Make : Legrand , Siemens, Schneider. |
| 68 | Supplying and fixing in replacement 10Sq mm 2Core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular shape |
| 69 | Supply only driver suitable for 2x2 LED panel Light Fitting of compatible capacity 36 watts. Make Bajaj or equivalent of Crompton Greaves/ Havells/ Jaquar. |
| 70 | Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete including taking out old UNSV cable all as specified and directed. cable of size 25 Sq mm 4 Core. |
| 71 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. |
| 72 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 73 | Removing excavated surplus soil to a distance not exceeding50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified. |
| 74 | Supply and laying 40mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 75 | Supply and fix ready made outdoor type heavy duty polymer earth pit chamber box of size 300x300x260 mm with provision of earthing strip/ GI pipe entry glands and cover complete all as specified and as directed by Engineer-in-Charge make JEAF techno earthing.(Note sample is kept in GE Ofiice sample room) |
| 76 | M& L in repair for Plastic trunk ISI marked of size 150x50 mm with flexible cover , internal angles (adj from 80 degree), external angles (adj from 60 degree), joints for 130 mm width cover, base joint and end cap complete including all fixing arrangement all as specified and as directed by Engr-In-Charge. |
| 77 | Supply and fix in repair for energy saving new generation environmental friendly long life versatile presure die cast AL housing IP 66 flood light fitting luminaire with secondary optics, high power LEDs as light source and electronic driver of capacity 150 watts with pre wired suitable for sports lightsfitting complete all as specified and as directed. Make: JAQUAR Cat Part No LFLDSLM150XC or equivalent of make Bajaj , Philips, Wipro, Havellsas approved |
| 78 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. |