Tender For Cleaning Of Sewage Line Septic Tank Soak Well And Repair/ Maintenance Of Drains Fencing Footpath Etc In Zone B Area Of Age B/R-I Under Ge (West) Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Cleaning Of Sewage Line Septic Tank Soak Well And Repair/ Maintenance Of Drains Fencing Footpath Etc In Zone B Area Of Age B/R-I Under Ge (West) Lucknow. Submission Date for this Tender is 27-04-2024. Footpath Work Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43078733
Corrigendum : Tender For Cleaning Of Sewage Line Septic Tank Soak Well And Repair/ Maintenance Of Drains Fencing Footpath Etc In Zone B Area Of Age B/R-I Under Ge (West) Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
27-04-2024

Tender Details

Tender For Cleaning Of Sewage Line Septic Tank Soak Well And Repair / Maintenance Of Drains Fencing Footpath Etc In Zone B Area Of Age B / R-I Under Ge ( West ) Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : CLEANING OF SEWAGE LINE, SEPTIC TANK, SOAK WELL AND REPAIR/ MAINT OF DRAINS, FENCING, FOOTPATH ETC INZONE "B" AREA OF AGE B/R-I UNDER GE WEST LUCKNOW
Sl. No. Item Description
1Dismantling fencing wiremesh any type completed all as specified and directed.
2Dismantling/Taking out barbed wire in fencing complete all as specified and as directed.
3Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground etc complete all as specified and as directed.
4M & L for PCC 1:3:6,type C2 (40mm graded stoneaggregate) as foundation, filling and mass concrete all as specified and directed.
5M & L for providing reiforced cement concrete type B-I, 1:2:4 (20mm graded aggregate) in percast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average, sectional areaexc 100 and n exc 250 sq.cm, with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and as directed.
6S & FGalvanised. 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barb at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins, etc complete all as directed (each line of wire to be measured).
7Restraining/resecuring including making good staples, Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins, etc complete all as specified and as directed (each line of wire to be measured).
8S & F Angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets including all necessary drilling, bolting or rivetting etc and similar work confirming to Fe 290 Gd E-165. complete all as specified and as directed.
9S & F mild steel screw bolts (machine made ) with hexagonal or square heads at one end, 10mm dia, not exc 10 cm long, bolt with waher and nuts complete all as specified and as directed.
10Supply of 3mm dia GI wirechain link fencing with 75x75mm mesh size and fixed to anytype of strandard rails straining bolts etc including provision ofbinding wire complete all as specified and as directed. Note: Weight constantant shall be detrmined by BOO of chain link fencing.
11Fixing only chain link fencing including line wires, any mesh, size and type fixed to any type of standards rails, straining bolts, etc.including provission of binding wire complete all as specified and as directed.
12S&F in repairs concertina coil fencing with punched tape coil 600mm dia 10 mtr openable length (Total lenght 90 mrt) having 50 nos round per 6 meter with tape (0.52mm thick) and weight 43.478 gm/mtr and fixing the same on Y shaped angle iron placed 2 mtr apart and with 6 horizontal RBT (reinforced barbed tape) wire, stud tied with GI stapes sand GI clips to retain horizontal, including necessary bolts complete all as specified and as directed.
13Demolition of brickwork built in cement mortar or cement lime mortar complete all as specified and as directed.
14Material and labour for brick work with sub class "B" brick (old size) straight or curved on plan exc 6m mean radius builtin CM 1:6 complete all as specified and as directed.
15ditto- as per above item No 14 but except bricks complete all as specified and as directed.
16M & L for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
17M&LCement concrete in type C-2,1:3:6 Using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
18M & L for cement concrete (1:2:4), type B0 using 12.5mm graded stone aggregate as in benching ,hunching for drainsetccomplete all as specified and as directed.
19Extra for forming fair finished drain or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and as directed.
20Ditto-- as per item abovebut add or deduct for each 25 mm girth or part thereof over or under 30cm complete all as specified and as directed.
21M & L plain cement concrete (1:2:4), type B1 using 20mm graded stone aggregate as in coping including necessary form work complete all as specified and as directed.
22Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
23Cutting hole in brick walls built in cement mortar or cement lime mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B-1 as required depth of embedded portion of hold fasts or Lugs measured from the face of the jamb in the wall exc. half brick but not exc. one brick complete all as specified and direced.
24S & F in repair framed work as in Doors or gates of angle or other section with plates, rails, braces, hold fast etc, complete drilled for fixing of steel sheeting or other covering etc complete all as specified and as directed.
25Taking downIron/steel door shutters, side hung exc 1.5 sqm and n. exc 5 sqm and refixing in same opening after repairing including weldingand necessary jointing cleats screws etc fittings such as hinges complete all as specified and as directed.
26Supply and fixing in repair 1.0mm thick PVC plain (colour as specified by Engr-in-charge) sheet including taking down old one in hearth covering to framed steel/iron doors/gates and in partition walls, etc cut to size edges beaded if directed holes punched including round headed screws clout nails or rivets and fixed to seel members complete all as specified and as directed.
27Supply and fixing in repairs 1.0mm thick mild steel plain black sheet in hearth covering to door shutters covering to door chawkhats (frames) chullahoods, watertanks, water troughs, ducts, urinal troughs and funnel etc cut to size edges beaded if directed holes punched including round headed screws clout nails or rivets and fixed to wood or steel members etc with plain 40mm lap joints or welded / riveted seams including bending , turning up, mitread angles stooped ends outlets etcas required complete all as specified and as directed.
28M & L preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
29Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
30M & L for Precast RCC 1: 2:4, type B1(nominalmix ) using 20mm graded stone aggregates as in cover slab etc complete all as specified and as directed.
31M & L for Mild steel TMT bars 10mm dia and over as in reinforcement,cut to length bent to shape required including hooking ends and binding with MS wire (annealed) not less than 0.9mm dia all as directed and specified.
32M & L for Mild steel TMT bars 6 to 8mm dia cut to length bent to shape required including cranking bending hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
33Demolition of PCC in ground floor and paving n exc 15cm thick below or above ground level complete all as specified and as directed.
34M & L for 40mm thick cement concrete 1:2:4, Type B-0 using 12.5 mm graded stone aggregateas in floors, finished even and smooth using extra cement complete all as specified and as directed.
35M & L for 38mm wide of glass dividing strips, 3mm thick and inserted in position to confirm design of flooring complete all as specified and as directed.
36M & L for 50 mm thick cement concrete type C1(1:3:6) using 20mm graded stone aggrtegate as in plinth protection including finsihing even & fair complete all as specified and as directed.
37Dismantling of reinforced cement concrete precast louvres and Jallies any type complete all as specified and as directed.
38M & L for Providing 35 mm thick precast RCC Louvres and Jallies type B0 (1:2:4) using 12.5mm graded stone aggregate complete all as specified and as directed.
39Dismantling stone slab and tiles of any description or and thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
40M & L for 75 mm thick Cement concrete 1:4:8,type D-2 using 40mm graded stone aggregate as in sub base etc complete all as specified and as directed.
41M&L 60mm thick rubber moulded glossy finish coloured interlocking precast PCC pavers any colour ofM-35 grade laid over 25mm thick sand cushioning and joint filled with fine sandincl levelling, tamping and sweeping etc complete all as specified anddirected.
42M & L for 400x400x20mm thick Exterior grade cement concrete tiles as in floor/pavings set and jointed in neat grey cement slurry and pointed with mixture of white cement and pigment over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed.
43M&L for chequered cement concrete tiles coloured glossy finish rubber moulding with mixture of white cementandpigments of size 30cmx30cmx25mm thick set, jointed and pointed in neat cement slurry in fooors incl 15 mm thick screed bed in CM 1:6complete all as specified and as directed.
44M & L Glass coping in repairs with broken glass @ 14 Kg/Square meter fixed in and including 20 mm thick cement mortar (1 : 3) complete all as speci-fied and directed.
45M & L and Cleaning/desludging of existing septic tank, of any capacity and depth with inlet/outlet chambers includingtaking out sludge (both organic and inorganic matter) in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots orvegetation etc by means of sewage sucking machine andafter plugging the incoming sewer line through combined high pressure water jetting/ suction (Vacuum) type machine mounted on LCV/HCVfacility of high pressure vacuum and removing the sludge outside MD land by any means and at a place meant for the purpose by local munucipality complete all as specified and as directed at site. Note:- For measurement purpose Liquid depth of septic tank shall be measured before removal of sludge.
46M & L and Cleaning/desludging of existing soakage well of any capacity and depth with inlet/outlet chambers includingtaking out sludge (both organic and inorganic matter) in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots orvegetation etc by means of sewage sucking machine andafter plugging the incoming sewer line through combined high pressure water jetting/ suction (Vacuum) type machine mounted on LCV/HCVfacility of high pressure vacuum and removing the sludge outside MD land by any means at a place meant for the purpose by local munucipality complete all as specified and as directed at site.
47M&L for Cleaning/desludging of existing sewar line from nahani trap to 1st manhole manually or by way of any other suitable meanes of any capacity and depth includingtaking out sludge in any form and other foreign matter etc viz. sediment, sand, ash, grease, night soil,fibre, silt, roots orvegetation etc and keeping the sewar line functional duly removing the sludge outside MD land by any means and at a place meant for the purpose by local munucipality complete all as specified and as directed at site.
48M&L for cleaning/clearing of sewer line (including in between manholes) up to 200 mm bore sewer line of any type and any location, depth ofmanhole n.exc. 3 meter in depth, section, line between the sewer lines to septic tank/soak well/sump well and cleaning any type of blockage including desilting, descaling and dechocking of drain and manhole manually or by any other way and keeping the sewer line functional and removing the sludge outside MD landand at a place meant for the purpose by local munucipality complete all as specified and as directed at site.
49M&L for cleaning/clearing of sewer line (including in between manholes) up to 200 mm bore sewer line of any type and any location, depth ofmanhole n.exc. 3 meter in depth, section, line between the sewer lines to septic tank/soak well/sump well and cleaning any type of blockage including desilting, descaling and dechocking of drain and manhole with combined high pressure water jetting cum suction vacuum type machine mouinted on LCV/HCV and havingfacility of high pressure vacuum and provn ofhydraulic application through high pressure thermo plastic fibre based water jetting hose and conical round shape nozzle pipe and flushing after cleaning and removing the sludge outside MD land by any means at a place meant for the purpose by local munucipality complete all as specified and as directed.
50Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.
51M&L for plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete including demolition of existing concrete complete all as specified and as directed.
52M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in benching, copings and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work and demolition of existing cement concrete complete all as specified and as directed.
53Returning filling in including spreading watering and well raming in layer excedding 25 cm each in soil complete all as specified and as directed.
54Removing excavated soil to a distance excedding 250 m but not exceeding 500 m and deposited where directed at a level not excedding 1.5m above the starting point complete all as specified and as directed.
55Taking up broken sewer line n. exc 1.5 m depth and replacing sewer pipe withPVC pipe 160 mm bore including jointing of pipe in CM 1:1, haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded stone aggregate including necessary excavation and earth work, disposal of material up to a distance not exc 50mtr and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified. Note:- Cutting existing manhole and making good shall be measured and paid seperately.
56Taking up broken sewer line exc 1.5 m but n.exc 3.0 m depth and replacing sewer pipe withPVC pipe 200mm bore including jointing of pipe in CM 1:1, haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded stone aggregate including necessary excavation and earth work, disposal of material up to a distance not exc 50mtr and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified and as directed. Note:- Cutting existing manhole and making good shall be measured and paid seperately.
57S&F in repair PVC (SWR) soil waste pipe of pressure rating 6kgf/Sqm single socketed in any length of 160mm bore with rubber ring joints laid in trenches for sewage disposal complete all as specified and as directed.
58M & L Cutting into existing man holes for connection new drains of dia of pipe 160mmdia pipe making good to pipe and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching complete all as specified and as directed at site.
59M & L Cutting into existing man holes for connection new drains of dia of pipe 200mm internal dia making good to pipe and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching complete all as specified and as directed.
60M & L Cutting into existing man holes for connection new drains of dia of pipe 110mm internal dia making good to pipe and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching complete all as specified and as directed.
61S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and as directed.
62S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and as directed.
63S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and fixed to walls complete all as specified and as directed.
64S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and fixed to walls complete all as specified and as directed.
65S&F PVC(SWR) bends 110mm dia complete all as specified and as directed.
66S&F PVC(SWR) bends 75 mm dia complete all as specified and as directed.
67S&F in repair 75 mm diameter of outletPVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
68S&F in repair 100 mm diameter of outletPVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
69S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet,integral foot rest with CI "P" or "S" trap and providing lime concrete bedding and connecting to flusing cistern complete all as specified and as directed.
70S&F in repair Viterous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and includingPlastic water closet seat cover white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
71S&F in repair vitreous china bowl urinal flat back of size 465 x 355x 265 mm, white excluding flushing cistern, flush pipe and waste pipe but including grating and union for discharge pipe complete all as specified and as directed.
72S&F in repair stainless steel grating doom without hole 125 mm dia complete all as specified and as directed.
73S&F in repair stainless steel grating doom with hole 125 mm dia complete all as specified and as directed.
74S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and as directed.
75S&F in repair PVC low level white flushing cistern valveless syphonic action type 10 lts capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend complete all as specified and as directed.
76S & F in repair plastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and as directed.
77S&F in repair waste pipe 32mm dia for WHB/ sink/ urinal complete all as specified and as directed.
78S & Fin repair hand shower (Health faucet) with 1 M flexible tube with wall hook bracket etc, complete set of superior quality complete all as specified and as directed.
79S & F in repair angle valve cast copper alloy with capstain head chromium plated screwed down, high pressurewith long shanks and fly nuts screwed for 15mm bore pipe complete all as specified and as directed.
80S & F in repair two way TAP cast copper alloy with capstain head chromium plated screwed down, high pressurewith long shanks and fly nuts screwed for 15mm bore pipe complete all as specified and as directed.
81M&L construction of soakage well of size 3.0M dia x 4.50M effective depth with fly ash bircks and RCC M-25 design Mix using 20mm graded stone aggregate as in cover slab etc. including all required earthwork in soft/loose soil, returning filing and removal etc and filling of brick bats and cement concrete etc complete all as shown on CELZ drawing No TD/576 sheet 1/2 & 2/2 complete all as specified and as directed. Note- filling of earth/rubble as ramming in old broken soakage pit and disconnectionof inlet sewage line inclusive of this items.
82M&L construction of soakage well of size 2.4M dia x 4.50M effective depth with fly ash bircks and RCC M-25 design Mix using 20mm graded stone aggregate as in cover slab etc. including all required earthwork in soft/loose soil, returning filing and removal etc and filling of brick bats and cement concrete etc complete all as shown on CELZ drawing No TD/576 sheet 1/2 & 2/2 complete all as specified and as directed. Note- filling of earth/rubble as ramming in old broken soakage pit and disconnectionof inlet sewage line inclusive of this items.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail