Tender For Repair And Maintenance Of External Water Supply And Comprehensive Maintenance Of Swimming Pool At Rv Area And Allied Works At Af Stn Palam Under Ge (Af) Palam Delhi Cantt-10, palam-Delhi

Military Engineer Services-MES has published Tender For Repair And Maintenance Of External Water Supply And Comprehensive Maintenance Of Swimming Pool At Rv Area And Allied Works At Af Stn Palam Under Ge (Af) Palam Delhi Cantt-10. Submission Date for this Tender is 20-04-2024. Swimming Pool Construction Tenders in palam Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43078520
Tender For Repair And Maintenance Of External Water Supply And Comprehensive Maintenance Of Swimming Pool At Rv Area And Allied Works At Af Stn Palam Under Ge (Af) Palam Delhi Cantt-10
Open Tender
Indian
Delhi
palam
20-04-2024

Tender Details

Tender For Repair And Maintenance Of External Water Supply And Comprehensive Maintenance Of Swimming Pool At Rv Area And Allied Works At Af Stn Palam Under Ge ( Af ) Palam Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 99900.0 /-
Tender Value
INR 49.92 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF EXTERNAL WATER SUPPLY AND COMPREHENSIVE MAINTENANCE OF SWIMMING POOL AT RV AREA AND ALLIED WORKS AT AF STN PALAM UNDER GE (AF) PALAM DELHI CANTT-10
Sl. No. Item Description
1Taking down defective self priming recirculation pump set of any type of capacity upto3.5 HP Three phase by unscrewing the foundation bolts, disconnecting from water connection and electric motor, opening for inspection in presence ofEngr-in-Charge and carry out repair at site such as replacement ofball bearing ,check nuts ,impeller,greasing ,gland,bush,casing gasket,nut bolt , washers etc and re-fixing, re-connecting in position, testing and commissioning complete all as specified and as directed by Engr-in-Charge.
2Taking down defective self priming recirculation electric motor of capacity 3.5 HP from electric mains, isolating the necked connections, removing from foundation by unscrewing the nuts, boltsetc, discouple from pump, opening of motor including transporting to the workshop for rewinding of motor, cutting ,removing of burnt winding, cleaning and winding of motor with copper enameled wire of same gauge and turn of existing winding , varnishing, baking , reassembling , relpacement of bearings and transporting back to the site & re-connecting same to foundation including replacement of nuts, boltswashers etc. ofsuitable size, testing and commissioning complete all as specified and directed by Engineer-in-charge. .
3Supply only for Alum (K2 SO4) for swimming pool for purifying the existing water complete all as specified and directed by Engineer-in-charge.
4S&F under water light with housing water proof LED light fittings with Driver, LED-NP 300S, round light 18W/ 12 V PAR 56 144 LEDs andnecessary fixing arrangement, fixed to concrete wallby means of long screws including making new hole by drilling machine and easily remove and fixing the fitting for future repair work with and including taking down unserviceable light fittings any type in swimming pool complete all as specified and as directed by Engineer-in-charge. Make:-Emaux cat part no 88045366 or equivalent in make Halbert.
5S&F in repair LED driver CVD upto18W/12Volt, suitable for under water light with housing water proof LED light fittings with and including taking down unserviceable LED driver upto18W/12Voltfrom fitting complete all as specified and directed by Engineer-in-charge .
6S&F in replacement PVC vacuum hose pipe 30 mtr length upto 50mm dia (suitable for connection of existing pipe) for cleaning the swimming pool complete all as specified and directed by Engineer-in-charge.Make –Emaux/Halbert
7S & F in replacement chemical testing kit for PH & chlorine of water complete all as specified and directed by Engineer-in-charge.
8S&F UPVC pipe 75 to 90 mm including elbow, socket, Nipple, tee etc, all as per site requirement with and including taking out unserviceable UPVC pipe 75 to 90 mm complete all as specified and directed by Engineer-in-charge.
9S&F UPVC pipe 110 to 160 mm including elbow, socket, Nipple, tee, reducer socket etc with and including taking out unserviceable UPVC pipe 110 to 160 mm all as per site requirementcomplete all as specified and directed by Engineer-in-charge.
10S&F union suitable to UPVC pipe 75 to 90 mm with and including taking out unserviceableunion 75 to 90 mm complete all as specified and as directed by Engineer-in-charge.
11S&F union suitable to UPVC pipe 110to 160 mm with and including taking out unserviceable union of size 110 to 160 mm complete all as specified and directed by Engineer-in-charge.
12S&F Aqua seal lever operated butterfly valve suitable to UPVC pipe 75 to 90 mm with necessary fixing arrangement like flange, nut, bolts as per existing etc with and including taking out unserviceable valve 75 to 90 mm complete all as specified and directed by Engineer-in-charge.
13S&F Aqua seal lever operated butterfly valve suitable to UPVC pipe 110to 160 mm with necessary fixing arrangement like flange, nut, bolts as per existing with and including taking out unserviceable valve 110 to 160 mm complete all as specified and directed by Engineer-in-charge.
14Supply only TCCA -90 Spa chlorine granuals 50 KG drumwhite powder granual or trichloroisocyanuric acid (C3O3N3CL3)-90 for swimming pool water purification for maintain the quality of water complete all as specified and directed by Engineer -in -charge. Make:- Halbert/Declibec TCCA-90.
15S&F in replacement Standard curved poly Bristle wall brush 18"" including telescopic pole of suitable length complete all as specified and directed by Engineer-in-Charge.
16S&F in replacement Leaf Skimmer of suitable size for swimming pool water cleaning complete all as specified and directed by Engineer -in -charge.
17S&F in replacement (250x30) mm x 1 m whiteover flow grating single pin lock system complete all as specified and directed by Engineer -in -charge. Make:- Halbert/Emaux/Pentair.
18Supply only Copper sulphate for colouring the water complete all as specified and directed by Engineer -in -charge.
19Supply and fixing single phase preventer VSP 2 complete all as specified and as directed by Engineer-in-Charge.
20Supply and Fixing in replacement of SP Series side mount filter valve of 6-way,dia 2"complete all as specified and directed by Engineer -in -charge. Make : Halbert/Emaux/Pentair.
21S&F in replacement of LED building light luminare 60 W LED Street light (Rodeo Series) Powder coated finish, Pressure die cast aluminium housing (New Shape) type complete with acrylic cover and including suitable fittings and fixtures GIbracket, nut , bolt. complete all as specified and as directed by Engineer-in-Charge. Make:- Syska/ Havells/philips.
22S&F in replacement of LED Beam/ Flood lights COB Series luminare 100 W Powder coated finish, Pressure die cast aluminium housing type complete with acrylic cover with and including suitable fittings and fixtures GIbracket, nut ,bolt complete all as specified and as directed by Engineer-in-Charge.Make:- Syska/ Havells/philips.
23S&F in replacement of LED Flood lights Range luminare 90 W Powder coated finish, Pressure die cast aluminium housing type complete with acrylic cover with and including suitable fittings and fixtures GIbracket, nut ,bolt complete all as specified and as directed by Engineer-in-Charge.Make:- Syska/ Havells/philips.
24Excavation in trenches not exc 1.5 meters wide and not exc 1.5 meters deep for pipe line in any type of soil, getting out and levelling of bottom surface to required level complete all as specified and as directed by Engineer-in-Charge.
25Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed by Engineer-in-Charge.
26Removing excavated material from site to a distance not exc 50 meters away and depositing where directed at a level not exc 1.5 meter from the starting point complete all as specified and as directed by Engineer-in-Charge.
27Taking up CI/DI water main including all fittings with spigot and socket ends and lead/tyton joints including burning out lead joints and recovering lead of the 80 mmsize of pipe complete all as specified and as directed by Engineer-in-Charge.
28Taking up CI/DI water main including all fittings with spigot and socket ends and lead/tyton joints including burning out lead joints and recovering lead of the 100 mmsize of pipe complete all as specified and as directed by Engineer-in-Charge.
29Taking up CI/DI water main including all fittings with spigot and socket ends and lead/tyton joints including burning out lead joints and recovering lead of the 150 mmsize of pipe complete all as specified and as directed by Engineer-in-Charge.
30Supply & Laying, jointing, testing cast iron pipe with spigot socketed ends centrifully cast, class LA, tyton joints/ lead jointconforming to IS-1536-1976 laid in trenches of80 mm dia sizes complete all as specified and as directed by Engineer-in-Charge.
31M&L for 100 mm ductile iron pipe with spigot and socket ends, centrifugally cast, class k-9(IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and as directed by Engineer-in-charge.
32M&L for 150 mm ductile iron pipe with spigot and socket ends, centrifugally cast, class k-9(IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and directed by Engineer-in-charge.
33Material and labour for run lead joint including jointing material for cast iron pipe of 80 mm size/bore complete all as specified and as directed by Engineer-in-Charge.
34Material and labour for run lead joint including jointing material for cast iron pipe of 100 mm size/bore complete all as specified and as directed by Engineer-in-Charge.
35Material and labour for run lead joint including jointing material for cast iron pipe of 150 mm size/bore complete all as specified and as directed by Engineer-in-Charge.
36Taking up or down 15mm dia bore GI tubing with connections including fittings complete all as specified and as directed by Engineer-in-Charge.
37Taking up or down 20mm dia bore GI tubing with connections including fittings complete all as specified and as directed by Engineer-in-Charge.
38Taking up or down 25mm dia bore GI tubing with connections including fittings complete all as specified and as directed by Engineer-in-Charge.
39Taking up or down 40mm dia bore GI tubing with connections including fittings complete all as specified and as directed by Engineer-in-Charge.
40Taking up or down 50mm dia bore GI tubing with connections including fittings complete all as specified and as directed by Engineer-in-Charge.
41Taking up or down 80mm dia bore GI tubing with connections including fittings complete all as specified and as directed by Engineer-in-Charge.
42Supply & Laying, jointing, testing GI pipe of 15 mm bore including fittings fixed to walls and ceiling or laid in floor, trench complete all as specified and as directed by Engr-in-Charge.
43Supply & Laying, jointing, testing GI pipe of 20 mm bore including fittings fixed to walls and ceiling or laid in floor, trench complete all as specified and as directed by Engr-in-Charge.
44Supply & Laying, jointing, testing GI pipe of 25 mm bore including fittings fixed to walls and ceiling or laid in floor, trench complete all as specified and as directed by Engr-in-Charge.
45Supply & Laying, jointing, testing GI pipe of 40 mm bore including fittings fixed to walls and ceiling or laid in floor, trench complete all as specified and as directed by Engr-in-Charge.
46Supply & Laying, jointing, testing GI pipe of 50 mm bore including fittings fixed to walls and ceiling or laid in floor, trench complete all as specified and as directed by Engr-in-Charge.
47Supply & Laying, jointing, testing GI pipe of 80 mm bore including fittings fixed to walls and ceiling or laid in floor, trench complete all as specified and as directed by Engr-in-Charge.
48Supply & Fixing gun metal gate valve suitable for 15mm bore dia pipe with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge.
49Supply & Fixing gun metal gate valve suitable for 20mm bore dia pipe with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge.
50Supply & Fixing gun metal gate valve suitable for 25mm bore dia pipe with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge.
51Supply & Fixing gun metal gate valve suitable for 40mm bore dia pipe with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge.
52Supply & Fixing gun metal gate valve suitable for 50mm bore dia pipe with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge.
53Supply and fixing including jointing and testing of cast iron sluice valves PN 1.6 class I, ISI mark flanged ends drilled having stainless steel / brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets for 80 mm bore complete all as specified and as directed.
54Supply and fixing including jointing and testing of cast iron sluice valves PN 1.6 class I, ISI mark flanged ends drilled having stainless steel / brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets for 100 mm bore complete all as specified and as directed.
55Supply and fixing including jointing and testing of cast iron sluice valves PN 1.6 class I, ISI mark flanged ends drilled having stainless steel / brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets for 150 mm bore complete all as specified and as directed.
56Supply and fixing including jointing and testing of cast iron sluice valves PN 1.6 class I, ISI mark flanged ends drilled having stainless steel / brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets for 200 mm bore complete all as specified and as directed.
57Material and labour for DI/CI specials such as Tees of any size and radius, collars, tapers, tail pieces, caps and plugs etc upto 150 mm bore complete all as specified and as directed.
58S&F GI Fittings reducers, tee, elbow, socket, nipple, plug, reducer socket, reducer elbow, unions and other connected accessoriesof size 15mm to 50mm complete all as specified and as directed by Engineer-in-charge.
59Disconnecting existing defective electric motor of any make capacity of motor upto5 HP from electric mains isolating the connections, removing from foundation by unscrewing the nuts, boltsetc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge & carrying out minor repairsat site and re-assemblingthe motor afterrepair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, boltswashers ofsuitable size, testing and commissioning complete all as specified and directed.
60All as per serial item No.59 here-in-before but capacity of motor 40HP to 50HP complete all as specified and as directed.
61Taking out old unserviceable/burnt copper winding ofmotors capacity upto 5 HP (defective motor taken out from Srl item No.62 above) and material and labour for rewinding of elect motor ofcapacity upto 5 HP, 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor,slots, all winding/insulation material, varnishingball bearing ms shaft etc. complete and testing at site on full load after re-installation to the satisfaction of Engr-in-Charge all as specified and as directed.
62All as per item No 61 here in before but taken out from 40 to 50 HP, 3 phase of any type & size complete all as specified and as directed.
63Taking out defective centrifugal pump set of any type, make and capacity by unscrewing the foundation bolts, disconnecting from water connection, and disconnecting from electric motor, opening for inspection in presence ofEngr-in-Charge and transported to contractor"s workshop, repair the pump including replacement of unserviceable housing gasket -1 set, greasing, nut, bolt with washer and refixing, re-coupling in position, testing and commissioning complete including replacement of nuts, bolts, washers etc. complete all as specified and as directed.(single/3 phase upto 5 HP).
64All as per item No 63 here-in-before but 40 to 50HP 3 phase of any type & size complete all as specified and as directed.
65S&F in replacement ofshaft of existing material suitable for 40 to 50 HP pump set complete all as specified and as directed.
66S&F in replacement ofimpeller of existing material suitable for 40 to 50 HP pump set complete all as specified and as directed.
67S&F in replacement ofshaft sleeve of existing material suitable for 40 to 50 HP pump set complete all as specified and as directed.
68S&F in replacement ofdrive end bearing 6313 complete all as specified and as directed.
69S&F in replacement ofCI bearing Gauge complete all as specified and as directed.
70S&F in replacement of gland assembly complete all as specified and as directed.
71S&F in replacement of throat bush complete all as specified and as directed.
72S&F in replacement of shaft coupling suitable for 40 to 50 HP pump set complete all as specified and as directed.
73S&F in replacement of unsv Rotor body complete all as specified and as directed.
74S&F of ball bearing of size 3309 complete all as specified and as directed.
75S&F in replacement of unsv cooling fan suitable for 40 to 50 HP induction motor of any type complete all as specified and as directed.
76Disconnecting, electrically, isolating the existing unserviceable MCCB of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB three phase, 415 volts fixed in existing panel including necessary modification for new MCCB, 400 Amp, 3 pole, breaking capacity 36 kA, conforming to relevant IS including all jointing and connecting material complete all as specified and as directed. Make:- Standerd/Havells/L&T.
77All as per item No.76 here-in-before but 250 Amps, breaking capacity 36 kA, 4 Pole complete all as specified and as directed by Engineer-in-Charge.
78All as per item No.76 here-in-before but 200 Amps, breaking capacity 35 kA, 4 Pole complete all as specified and directed by Engineer-in-Charge.
79All as per serial item No. 76 here-in-before but 125 Amps, breaking capacity 25 kA, 3 pole complete all as specified and directed by Engineer-in-Charge.
80All as per serial item No. 76 here-in-before but 100 Amps, breaking capacity 36 kA/ 25 KA, 3 pole complete all as specified and directed by Engineer-in-Charge.
81All as per serial item No. 76 here-in-before but 63 Amps, breaking capacity 10 kA, 4 pole complete all as specified and directed by Engineer-in-Charge.
82All as per serial item No. 76 here-in-before but 32 Amps, breaking capacity 10 kA, 3 pole complete all as specified and directed by Engineer-in-Charge.
83Disconnecting and Lifting out of existing submersible pump set from borewellcapacity upto 7.5HP alongwith their column pipe and submersible cable from bore well from any depth and lowering after repair complete all as specified and as directed by Engineer-in-charge.
84Taking out old unserviceable/burnt copper winding ofsubmercible pump capacity upto 7.5 HP (defective motor taken out from Srl item No.83 above) and material and labour for rewinding ofsubmercible pump ofcapacity upto 7.5 HP, 3 Phase with super enameled PVC insulated copper winding wire of suitable gauge as per existing including cleaning of rotor,slots, all winding/insulation material, bearing etc. complete and testing at site on full load after re-installation and replacement of unserviceable parts to the full satisfaction of Engr-in-Charge complete all as specified and as directed.
85M&L for Servicing of submersiblepump set including replacement of thrust plate shaft sleev, spacer, impeller - 04 Nos, SS shaft - 01 No, stud 4 Nos and filling of water and making it water tight complete all as specified and as directed by Engineer-in-charge
86S&Fin replacement GI column pipe 50mm dia heavy duty class "C" with GI flanged and drilled at both ends duly threaded and welded of 3 mtr long alongwith cut for passing the submersible cable including bolts, nuts, washers and rubber insertions packing complete all as specified and directed by Engineer-in-charge. Make- Jindal / SWASTIK / PARKASH
87S&Fin replacement GI column pipe 80mm dia heavy duty class "C" with GI flanged and drilled at both ends duly threaded and welded of 3 mtr long alongwith cut for passing the submersible cable including bolts, nuts, washers and rubber insertions packing complete all as specified and directed by Engineer-in-charge. Make- Jindal / SWASTIK / PARKASH
88Supply, connecting, testing and commissioning submersible cable with copper conductor, stranded of size 4 sqmm 3 core complete including dismantling the old unserviceablecable complete all as specified and as directed.
89Supply, connecting, testing and commissioning submersible cable with copper conductor, stranded of size 6 sqmm 3 core complete including dismantling the old unserviceablecable complete all as specified and as directed.
90S&Fin replacement water proof joint for submersible cable suitable for size 4/6 sqmm 3 core complete all as specified and as directed by Engineer-in-charge.
91Supply, installation, testing and commissioning of pressure pumpset 1 HP with automatic pressure switch which switches the pump on and off based on turning on and off of the Tap, air tank of suitable capacity, pressure gauge etc with and including taking down unserviceable pressure pump set complete all as specified and as directed by Engineer-in-Charge.
92M&L CI Non return valve without by pass arrangement confirming to IS-5312 part-1, PN 1.0 including nuts, bolts, washers and gaskets including taking out old unserviceable NRV 100 mm dia complete all as specified and as directed by Engineer-in-charge.
93M&L CI Non return valve without by pass arrangement confirming to IS-5312 part-1, PN 1.0 including nuts, bolts, washers and gaskets including taking out old unsv NRV 150 mm dia complete all as specified and as directed by Engineer-in-charge.
94Material and Labour for in replacement CI foot valve flanged type including nuts, bolts, washers and rubber 150 mm dia confirming to IS-4038complete all as directed by Engineer-in-Charge.
95Taking up or down Electric motor and pump of 40 HP to 50 HP of any make or type after disconnecting from all the misscelenious items such as NRV, reducer, CI-Tee, Pipelines etc andelectric connection as all required at site including dimantling and taking out old rusted steel/iron channel/ foundation, vibration pad after taking all safety measures including all lifting work,welding work if any, cutting and supply and fixing vibration pad in six numbers and one steel/iron channel/motor foundation of size suitable for motor and pump of 30 HP to 50 HP, fixing the motor and pump of above said capacity and fixing all connecting items including NRV, reducer, CI-Tee, Pipelines with all minor work such as cutting, welding, electric connection, nut, bolts, gland, flange etc of any size and makecomplete all as specified and directed by Engr-in-charge.
96Supply only CDD 5000 (two components chlorine dioxide powder) (CAS No 10049-04-4 conforming to ISO9001-2015) white in colour highly soluble in water, 99.9% effective against water borne micro organisms disinfectant for chlorination of water complete all as specified and directed by Engr-in-charge.
97M&L for Flushing of existing borewells of size upto 300mm dia, depth upto 200 mtr with drilling compressor including surging and flushing the bore at a pressure of 7 kg/ sqcm minimum 8 hrs, complete with compressed air and flushing the sand, mud etc from the bore well complete all as specified and directed by Engr-in-charge. Note:- Disconnecting and lifting out of existing submerssible pumpst from borewell upto 10 HP capacity along with their column pipe and submerssible cable fromborewell from any depth and lowering after flushing existing borewell shall be deemed to be included the unit item rate.
98M&L for chemical and bacteriological analysis and potability of water obtained from Delhi Jal Board & borewells from Sriram Test House/ MCD approved micro engineering and testing lab and submitting the report in duplicate complete all as specified and as directed by Engineer-in-charge. Note:- The Report shall be carried out quarterly and submit to GE for verification and record.
99Supply, installation and testing for maintenance free grounding (earthing) system complete burried directly in ground vertically (earth pit not less than ten feet below ground level) by making bore hole of 100 mm dia for inserting one number 17 mm dia molecular copper bonded high tensile low carbon steel circurlar earth electrode of 3 meter length with average copper thickness of 100 microns alongwith environmental friendly grounding enhancing compound and heavy duty (HDPE) PVC pipe cap all in below ground level and connected to copper strip 25mm x 3 mm flat by means of brass metal bolts , nuts and washers etc including protection pipe of GI 40 mm bore Medium grade upto 7.5 meter length and connection of earth lead to maintain distribution/LT panel board/DG set with copper lugs complete all as specified and as directed by engineer in charge. Note:- Rate for necessary earth work, PVC pipe, copper strip and all materials supplied by the contractor shall be deemed to be included in quoted rate ofitem.
100M&L for earthing complete with Galvanised steel earth plate electrode 600mm x 600mm x 6mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.5 Mtr below the ground level connected to GI earth strip of 25mm x 4 mmsize by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in mix (1:2:4) (using 20 mm graded stone aggregates) chamber, 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in Electrical plate No.3 of SSR Part-I including earth work in any type of soil, removal of surplus soil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by Engr- in -charge. Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer. GI pipe and GI strip beyond 7.5 shall be measured and paid separately under respective items.
101Supply and fixing Auto timer clock as per existing complete all as specified and directed by Engineer-in-Charge.
102Supply and fixing of single phase preventorVSP-2 / VSP-1 complete all as specified and as directed by Engr-in-Charge. Make: -Minilac/ L &T/ Lagrand
103Material & Labour for painting to existing centrifugal motor & pumping set complete including base frame with super enameled paint of existing colour coat by spray painting and writing of SM/MES No with white paint, 40 to 50 HP capacity all as specified and directed by Engineer-in-Charge.
104All as per item No 103 above but upto 5 HP capacity any type and make complete all as specified and as directed.
105Material and labour for Servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 mtr length for each plant including servicing of motor, washing of chlorine tank with descaling agent and re-commissioning testing of plant complete all as specified and as directed.
106Supply and fixing for Amps meters 0 to 200 Amps, Digital type with selector switches, CTs etc complete all as specified and as directed by Engineer-in-charge.
107Supply and fixing for voltmeters 0 to 500 Volt, Digital type 415 volts with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge.
108Supply and fixing LED indicator lamps (R,G,Y) complete all as specified by Engineer-in-charge.
109Supply and fixing Automatic pressure control switch suitable for pressure pump of capacity upto 1.0 HP complete all as specified and as directed by Engineer-in-charge.
110Supply and fixing pressure gauge 0-10 Kg/ Sqcm suitable for pressure pump complete all as specified and directed by Engr-in-charge.
111Supply and fixing air tank of suitable capacity as per existing for pressure pump of capacity upto 1.0 HP complete all as specified and as directed by Engr-in-charge.
112Material and Labour for cutting of hard standing upto suitable depth for inserting the pipe upto 250mm bore dia/ Cables of any size and making good the disturbed surfaces with paste pre mix bituminous 50mm thick polymer based material over WBM 75mm thick including rolling work etc complete all as specified and as directed by Engineer-in-Charge.
113Supply and fixing in replacement of unserviceable display board for showing details of pump houses and borewells as provided by Engineer -in-charge made out of white PVC sheet of size 1.5mtrX1mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame with cable 2 core 1.5 sqmm to connect from electric source and making arrangement for replacement of tubelights including round steel pole minimum 12 feet long of suitable dia for erection on ground with PCC complete all as specified and as directed by Engineer-in-charge.
114Supply, laying, jointing and testing of50 Sqmm 4 core XLPE insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade,laid in trenches, passing through ducts/pipes, fixing along poles, complete all as specified and directed. Note:- Excavation, earthwork and protection of cable shall be measured and paid seperately.
115M & L brick protection with old size sub class ‘B’brick for PVC underground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gape betweenadjacent brick not exceeding 10mm over LT under ground cable complete all as specified and directed.
116M&L for dry coarse sand as cushioning to cable 8 cm before laying of LT cable in trenches and 15 cm after laying the LT cable complete all as specified and as directed by Engineer-in-Charge.
117M&L for Painting of water supply header of size 100/150/200/250/300mm dia with two coat of synthetic enamel paint with a suiatble colour as per instruction complete all as specified and directed by Engr-in-charge.
118M&L for taking out and refixing of existing interlocking tiles over 50mm thick sand layer taken out during excavation from the surface after placing the pipe/ cable in trench and making good the all disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
119Supply only in replacement of Aluminium vaccuum suction head 18" complete all as specified and as directed by Engineer-in-Charge.
120Supply and fixing PVCcopper conductor cable of size 4.00 sqmm single core multistranded FRLS complete all as specified and directed by Engr-in-charge.
121Supply and fixing PVCcopper conductor cable of size 1.50 sqmm single core multistranded FRLS complete all as specified and directed by Engr-in-charge.
122Supply and fixing PVCcopper conductor cable of size 1.50 sqmm 2 core FRLS complete all as specified and directed by Engr-in-charge.
123Supply and fixing BI metallic over load relay, range 36-60 amp rating for automatic starters complete all as specified and directed by Engineer-in-charge. Make:- Legrand/LT
124All as per item No 123 above but 9-15 Amps complete all as specified and directed by Engineer-in-charge.
125Supply and fixing in replacement of unserviceanle sheet metal enclosure for distribution board SPN (when MCBs to be used) 8 way double door 200 Amps rated bus bar and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge.
126Supply and fixing in replacement of unserviceable MCB,SP, C series 6-32 Amps 10 KA as existing at site complete all as specified and as direceted.
127Supply and fixing in replacement of unserviceable SPN C series 32 Amps 10 kA complete all as specified and as directed.
128M&L for augering of holes in true horizontal position under road by trench less method by means of mechanical rig covering in route upto 1.5 mtr deep and not exceeding 30 mtr long for passing the water pipe lines upto 150mm bore all as specified and as directed by Engr-in-Charge.
129S&F in replacement of lead acid battery 12 volts 180 AH of existing type & size suitable for Gen set 15 to 125 kva including initial charging and copper connector complete all as specified and as directed by Engr-in-Charge.
130Supply, Installaiton, commissioning and testing in replacment of LT panel outdoor cubical floor mounted type made out of 3.15mm thick CRCA sheet, mounted on MS angle iron of (50x50x6)mm having length 80cm long ( 30cm to be grouted in PCC) dulypowder coated complete with bus bar200 amps rating made of Copper strip duly drillled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50Hz power supply systemincluding necessary earth work and suitable for housing the following :- INCOMING: (i) MCCB 40 Amps 4 Pole 50 Hz 415 Volt with rupturing capacity 25 KA - 01 No OUTGOING : (ii) MCCB 32 Amps 3 Pole 50 Hz 415V with rupturing capacity 16 KA.- 01 No. (iii) MCB 40 Amps 2 Pole 50 Hz 220V with rupturing capacity 10 KA.- 01 No as Out going (iv) Fully automatic Submersible starter,415 Volts 3 Phase, 50 HZ, relay range 13 to 21 Amphaving facility for single phase protection, over load, short circuit and phase reversal, (v) Indicator set RYB 01 set of 3 pcs (vi) Mutifunction digital meter with in built selector switch and CT of appropriate ratio - 01 No. (vii) Automatic Phase sequence corrector of suitable capacity - 01 No.
131Supply, installation, testing and commissioning in replacement of electric panel flush pattern (Indoor type) fabricated and made out of MS sheet 2 mm thickness with angle iron frame of size50mm x 50mm x 6mm for mounting of panel weather /dust proof fixed with insulater 4 wire system duly painted two coats of synthetic enamelled grey paint over a coat of red oxide primer including provision of PCC platform of suitable size complete with the followng accessories:- Incoming : (a) Loadline MCCB 4 pole 100 amps 415V 10 KA -01 Nos Make- Havells (b) Digital voltmeter 0-500V - 01Nos(c) Digital amp meter 0-250 amps - 01 Nos(d) Rotary Volt meter selector switch-01 No (e) Rotary Amp selector switch-01 Nos (f) LED Indicator light RYG-03 Nos(g) Control MCB DP 20 amps -01 No (h) Control MCB TPN 40 amps -01 No(l)CT of suitable size Outgoing: (a)Loadline MCCB 4 Pole 415 volt 63 amps 10 KA -05 Nos Make- Havells (b)CT of suitable size(e) Copper bus bar 200 Amps 4 strip system for all MCCBs (f)Digital Amp meter 0-250 Amps - 05 Nos including wiring and new copper thimbles on panel complete all as specified and as directed Engineer-in-charge
132Supply and fixing in replacement 5.5 HP motor and recirculation pumping set suction sweeper machine suitable for cleaning swimming pool complete all as specified and directed by Engr-in-Charge.
133Supply and fixing in replacement SS Trolley mounted on wheels 04 nos fabricated complete suitable for mounting 5.5 HP motor and recirculation pump suction sweeper machine complete all as specified and directed by Engr-in-Charge.
134Supply and fixing in replacement Starter incl ON/OFF switch suitable for 5.5 HP motor of suction sweeper machine complete all as specified and directed by Engr-in-Charge.
135Supply and fixing in replacement of unserviceable power contactor MNX 50-70 Amps suitable for 40 to 50 HP pumping set complete all as specified and directed by Engr-in-charge.
136Supply and fixing in replacement of unserviceable power contactor HGS 50-65 Amps suitable for 40 to 50 HP pumping set complete all as specified and directed by Engr-in-charge.
137M&L for construction of valve pit chamber (internal dimension 120 cm x 120 cm x 120 cm ) with15 cm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate infoundation, 23 cm thick brick workin CM (1:4), 10 mm thick rendering in CM (1:4) all around the brick work , 50 mm thick PCC (1:2:4) type B-1 incoping includinggrouting MS frame made out of 40mm x 40mm x 6mm thick angle iron including 3 mm thick MS plain sheet cover with locking arrangementwith50 mmpad lock and double key arrangement, includingpainting of steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation work in any type of soil, returning/ filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point includingdismantling ofexisting valve chamber complete all as specified and directed byEngineer-in-Charge.
138All as per item No 137 above here-in-before but for internal dimension 90cmX90cmX90cm complete all as specified and directed by Engr-in-charge.
139Supply and fixing in replacement of unserviceable display board for showing details of pump houses and borewells as provided by Engineer -in-charge made out of white PVC sheet of size 2.0mtrX1.5mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame with cable 2 core 1.5 sqmm to connect from electric source and making arrangement for replacement of tubelights including round steel pole minimum 12 feet long of suitable dia for erection on ground with PCC complete all as specified and as directed by Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail