Military Engineer Services-MES has published Tender For Repair / Maintenance Of Cooling Appliances Such As Air Conditioners, Water Coolers, Deep Freezers, Refrigerators, Desert Coolers, Etc Installed At Various Locations / Building S And Other Allied Works In The Area Of Age E / M ( N ) Under. Submission Date for this Tender is 25-04-2024. Air Conditioner Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Apr-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-04-2024 |
Sl. No. | Item Description |
1 | Servicing only of window type air conditionerin citu of capacity 1.5/ 2.0 Ton of any make and any type by replacing unserviceable parts (except compressor) from the machine including charging of Refrigerant if required, Brazing the suction / discharge tubes where required and cleaning of cooling coil, condensing coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defectivethermostatswitch, relay, capacitor and over load protector to achive proper cooling effect and testing commissioning complete all as specified and directed. (Note:- Additional gas required will paid & measured separately under relevant item.) |
2 | Taking out unserviceableWindow type air conditioner of capacity 1.5/2.0 Ton of any make and any type by replacing unserviceable compressor and other parts from the machine. Brazing the suction / discharge tubes where required and cleaning of cooling coil, changing of wirings with proper size PVC insulated wires as directed. Install the Air conditioner at location where directed after proper repair and testing complete at site as per the satisfaction of Engr- in - charge. |
3 | Note for iten No 1 & 2 :-i) Compressor where ever is required shall be measured and paid separately under respective item. |
4 | ii) Spares parts where ever is required shall be measured and paid separately under respective item of schedule A. |
5 | iii) Unit rate is deem to be included for minor parts such as capilary tube, machine screw, washer, rubber bush etc required for proper setting of machine. |
6 | Supply only thermostat suitable for window type AC 1.5/2.0 ton capacity for 230 volt 50 Hz AC supply complete all as specified and directed. |
7 | Supply only PVCinsulated, copper cable, 2.5 Sqmm , 3 core, complete all as specified and directed. |
8 | Supply only PVCinsulated, copper cable, 4 Sqmm , 3 core, complete all as specified and directed. |
9 | Supply only for replacement of unserviceable swinging motor of indoor unit of split type AC up to 3TR capacity suitable for existing make/model complete all as specified and directed by Engr in charge |
10 | Supply only for replacement of blower motor with bush and washers as per existing make and model for split type AC up to 3 TR Capacity complete all as specified and directed. |
11 | Supply only for replacement of blower motor with bush and washers as per existing make and model for Window AC up to 2 TR Capacity complete all as specified and directed. |
12 | Supply only capillarytubespecialannealeddouble woundcopper tubingsuitable for 1.5/2 ton windowtype air conditioner of diameter 0.25 " bore as per existing complete all as specified and directed. |
13 | Supply only capillarytubespecialannealed double woundcopper tubingsuitable for 1.5/2 ton windowtype air conditioner of diameter0.38" bore complete all as specified and directed. |
14 | Supply only cooling coil made out of copper tubeas per existing coil capacity and specificationsuitablefor 1.5/2 tonwindow AC of any make and typeas per existing complete all as specified and directed. |
15 | Supply and fix condensercoil made out of copper tube per existing coil capacityandspecification suitable for 1.5/2 tonwindow AC of any make and type as per existing complete all as specified and directed. |
16 | Supply and fix condensercoil made out of copper tube per existing coil capacityandspecification suitable for 1.5/2 ton split AC of any make and type as per existing complete all as specified and directed. |
17 | Supply only hermetically/Rotarysealed compressor unit 1.5 TR capacity for window type AC as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make :-LG/Whirlpool/Blue Star/Godrej |
18 | Supply only hermetically/ Rotary sealed compressor unit 2 TR capacity for window type AC as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make :-LG/Whirlpool/Blue Star/Godrej |
19 | M & L for Taking out window type air conditioner of any capacity and make for shifting at other placeafter making necessary opening in window/ wall of any type and thikness, cutting of grill any type/ size fixing of AC after servicing, providing necessary plywood, commerical type, 6 mm thick of suitable size as packing material to cover the hole/ window complete all as specified and directed. Note :- Transportation for shifting of AC"s will be provided by contractor and rate for same is deemed to be included in quoted rate. |
20 | Servicingonly any type Split air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5/2.0 TR of any make and any type by replacing unserviceable parts from the machine includingBrazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuitand replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning complete all as specified and directed. |
21 | Note for iten No 13 :-i) Compressor where everis required shall be measured and paid separately under respective item. |
22 | ii) Spares parts where ever is required shall be measured and paid separately under respective item of schedule A. |
23 | iii) Unit rate is deem to be included for minor parts such as capilary tube, machine screw, washer, rubber bush etc required for proper setting of machine. |
24 | Supply only overload protector relay for split type AC of capacity 1.5 ton as per site requirement complete all as specified and directed. |
25 | Supply only running capacitor 36 MFD and complete all as specified and directed. |
26 | Supply only running capacitor 50+4, 50+6 MFD and complete all as specified and directed. |
27 | Supply only running capacitor 45 MFD and complete all as specified and directed. |
28 | Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed. |
29 | Supply only sub zero sensor for package type AC of existing makes and model of any capacity complete all as specified and directed. |
30 | Supply only display sensor for split type of capacity upto 2.0 TR AC of existing makes and model of any capacity complete all as specified and directed. |
31 | Supply only out door unit fan blade heavy duty of existing make Split AC of capacity 1.5 ton/ 2.0 tonas per existing complete all as specified and directed. |
32 | S & F for copper tubing of size 1/2” for discharge line any make of split AC of capacity 1/1.5 ton with insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed. |
33 | S & F for copper tubing of size 1/4” for discharge line any make of split AC of capacity 1/1.5 ton with insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed. |
34 | S & F for copper tubing of size 3/8” for discharge line any make of split AC of capacity 2 ton with insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed. |
35 | S & F for copper tubes of size 5/8” for Suction line ofsplit AC of capacity 2 ton including insulation sheet of pipe tube type insulation including removal of old existing unsv onecomplete all as specified and directed. |
36 | S & F forhigh wall blower fixed on indoor unit of make as per existingsplit AC 1.5/2 ton capacity including removal of old existing unsv onecomplete all as specified and directed. |
37 | S & F for indoor unit split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display systemof make/model as per existing including removal of old existing unsv one complete all as specified and directed. |
38 | S & F indoor unit for Inverter type split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display systemof make/model as per existing including removal of old existing unsv one complete all as specified and directed. |
39 | Taking down existing unserviceable outdoor unit fan blade motor and supply and fix new fan blade motor for outdoor unit of 1.0TR capacity Split AC make and capacity as per existing complete all as specified and directed. |
40 | Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 1.5 TR capacity Split AC of any make/model and capacity as per existing complete all as specified and directed. |
41 | Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 2.0 TR capacity Split AC of any make/ model and capacity as per existing complete all as specified and directed. |
42 | Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 3.0 TR capacity Split AC make and capacity as per existing complete all as specified and directed. |
43 | Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 4.0 TR capacity Split AC make and capacity as per existing complete all as specified and directed. |
44 | Supply and fix for three phase preventer suitable for operation on 415 Volts 50 Hz AC supplyincluding removal of existing unserviceable one compete all as specified and as directed. Make : L&T/ Minilec. |
45 | S & F for indoor unit split type air conditioner 2.0 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make/model as per existing including removal of old existing unsv one complete all as specified and directed. |
46 | S & F indoor unit for Inverter type split type air conditioner 2.0 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make/model as per existing including removal of old existing unsv one complete all as specified and directed. |
47 | S & F for flexible PVC pipe 20 mm dia heavy duty from outdoor unit to indoor unit including removal of old existing unsv one complete all as specified and directed. |
48 | Removing the old unserviceable sealed compressor unit from split AC ofany make, capacity 1.5 TR and supply and fixing new hermetically/Rotary/DC sealedcompressor of as per site requirement for split AC ofcapacity 1.5 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed.Make :LG/Whirlpool/Blue Star/Godrej |
49 | Removing the old unserviceable sealed compressor unit from split AC ofany make, capacity 2.0 ton and supply and fixing new hermetically/Rotary/DC sealedcompressor of same make for split AC ofcapacity 2.0 TR as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed.Make : LG/Whirlpool/Blue Star/Godrej |
50 | Removing the old unserviceable sealed compressor unit from split AC ofany make, capacity 3 TR and supply and fixing new hermetically/Rotary sealedcompressor of same make for split AC ofcapacity 3 TR as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed.Make : LG/Whirlpool/Blue Star/Godrej |
51 | S & F for PCB (Printed circuit board) of indoor unit of 1.5/2.0ton capacitysplit AC including removal of old existing unsv one complete all as specified and directed. |
52 | S & FPCB (Printed circuit board) for Inverter type AC indoor/outdoor unit of 1.5/2ton capacitysplit AC including removal of old existing unsv one complete all as specified and directed. |
53 | S & F for new powder coated Mild Steel stand suitable for outdoor unit of split AC ofexisting size to install outdoor unit on wall/ floor as required on site with legs and bracing etc including removal of old existing unsv one complete all as specified and directed. |
54 | Taking down existing unserviceable outdoor unit and supply and fix new outdoor unit for 1.5 TR capacity Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired but with compressor of make as per existing complete all as specified and directed. |
55 | Taking down existing unserviceable outdoor unit and supply and fix new outdoor unit for 1.5 TR capacity Inverter type Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired but with compressor of make as per existing complete all as specified and directed. |
56 | Taking down unserviceable outdoor unit and supply and fix new outdoor unit for 2.0 capacity Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired with compressor of make as per existing complete all as specified and directed. |
57 | Taking down unserviceable outdoor unit and supply and fix new outdoor unit for 2.0 capacity Inverter type Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired with compressor of make as per existing complete all as specified and directed. |
58 | Supply and fix remote control for AC as per sample of any make, type, capacity including removal of extg unsv one complete all as specified and directed. |
59 | M & L for taking out Split type air conditioner indoor and outdoor unit complete with copper tubing of any size and make for shifting at other placeafter making necessary opening size, cutting of wall any type/ thickness andfixing of AC after necessary servicing,making suitable arrangement for fixing of AC complete all as specified and directed.Note :- (a) Transportation for shifting of ACs will be provided by contractor and rate for same is deemed to be included in quoted rate. |
60 | M & L for comphrensive maintenance of package air conditioner of capacity 11.00 TRincluding servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
61 | M & L for comphrensive maintenance of Package/ AC of 7.50 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
62 | M & L for comphrensive maintenance of Package AC of 5.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
63 | M & L for comphrensive maintenance of cassete/split type AC of 4.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
64 | M & L for comphrensive maintenance of tower AC of 4.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
65 | M & L for comphrensive maintenance of split/tower/cassette AC of 3.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
66 | M & L for comphrensive maintenance of tower/cassette AC of 2.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ductingand checking the all electrical connections,contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job") |
67 | Removing the old unserviceable sealed compressor unit from ductable package/ splitAC of any make of capacity 7.50 TR and supply and fixing new hermatically sealedcompressor of same existing make for ductable split AC ofcapacity 7.50 TR working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressurecomplete and all as specified and directed. |
68 | Removing the old unserviceable sealed compressor unit from ductable package/splitAC of any make of capacity 5.0 TR and supply and fixing new hermatically sealedcompressor of same existing make for ductable split AC ofcapacity 5.0 TR working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressurecomplete and all as specified and directed. |
69 | Removing the old unserviceable sealed compressor unit from ductable split/ tower/ packageAC of same existing make of capacity 4.0 TR and supply and fixing new hermatically/Rotary sealedcompressor of as per site requirement for ductable split AC ofcapacity 4.0 TRworking with non CFC refrigerent including supply andcharging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressurecomplete and all as specified and directed. |
70 | Removing the old unserviceable sealed compressor unit from ductable split/TowerAC of same existing make capacity 3.0 TR and supply and fixing new hermatically/Rotary sealedcompressor of as per site requirement for ductable split/tower AC ofcapacity 3.0 TR working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressurecomplete and all as specified and directed. |
71 | Removing the old unserviceable sealed compressor unit from ductable split/TowerAC of same existing make of capacity 2.0 TR and supply and fixing new hermatically sealedcompressor of same make for ductable split/tower AC ofcapacity 2.0 TR working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressurecomplete and all as specified and directed. |
72 | S & F for PCB (Printed circuit board) of ductable type AC unit 7.5 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas |
73 | S & F for PCB (Printed circuit board) of ductable type suitable forAC unit 5 TR of existingmake including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas |
74 | S & F for PCB (Printed circuit board) of ductable type package/ tower/ split AC suitable for unit4.0 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas |
75 | S & F for PCB (Printed circuit board) of ductable type package/ tower/split AC suitable for unit3.0 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas |
76 | Supply and fixDC motor for Inverter type split AC 1.5/2.0 TR outdoor unit 30 W 230 Volts single phase with 1300 RPMsuitable for existing make/model complete all as specified and directed. |
77 | Supply and fixDC motor for Inverter type split AC 1.5/2.0 TR indoor unit 18W 230 Volts single phase with 900 RPMsuitable for existing make/model complete all as specified and directed. |
78 | Supply only electric blower fan motor 1/20 HP 230 Volts single phase with 950 RPMsuitable for water cooler complete all as specified and directed. |
79 | S & F for contactorfor smooth functioning of control panel including removal of extg unsv one complete all as specified and directed. Make: Siemens Cat No. 3TF44 or equivalent from L&T. Note :- If Cat No. is revised, equivalent cat No. from latest Catalogue shall be considered. |
80 | M&L forleakdetection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proofthe gas system, cleaning, vacuum thegas system and charging suitable gas of any type as required on site quantity to achieve desire cooling complete all as specified an directed- (Note:- Additional gas required will paid & measured separately under relevant item.) |
81 | (a) Split type AC1.5 TR capacity |
82 | (b) Split type AC2.0 TR Capacity |
83 | (c) Split type AC 3.0 TR capacity |
84 | (d) Split type AC 4.0 TR capacity |
85 | (e) Split type AC 5.0 TR capacity |
86 | (f) Split type AC 7.5 TR capacity |
87 | M&L forleakdetection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proofthe gas system, cleaning, vacuum thegas system and charging suitable gas of any type as required on site quantity to achieve desire cooling complete all as specified an directed- (Note:- Additional gas required will paid & measured separately under relevant item.) |
88 | - Ditto- all as per item No 75 above but Window type AC1.5 TR capacity |
89 | - Ditto- all as per item No 75 above but Window type AC2.0 TR Capacity |
90 | M&L for replacement of unsv contactor kit of split type AC as per existing make & modelup to 3 TR complete all as specified and directed. |
91 | Taking out water cooler of any capacity and make, from siteforservicing, cleaning of cooling coil, condensercoil and waterstorage tank, oiling to blowermotor, checkingof electrical circuit and replacement of defective spare parts such as capacitor,relay, over load protection, blower motors etc, found defective on siteasrequired, testing for smooth functioning etc complete all as specified and directed. Note :-Supply only spare parts shall be measured and paid separately under relevant Items given below. |
92 | Supply only overload protector of SR-2612 to water cooler complete all as specified and directed. |
93 | Supply only starting capacitor40/60/80/100 MFD for water cooler any type/sizecomplete all as specified and directed. |
94 | Supply only running capacitor 10 to 36 MFD complete for water cooler any type/size complete all as specified and directed. |
95 | Supply onlyrelay for water cooler of any type & capacity as per existing and complete all as specified and directed. |
96 | M&L forleakdetection by nitrogen pressure test in refrigerant system of Refrigerator,Water cooler & Deep freezer by cutting brazing and making leak-proofthe gas system, cleaning, vacuum thegas system and charging suitable gas of any type as required on site quantity to achieve desire cooling complete all as specified an directed- (Note:- Additional gas required will paid & measured separately under relevant item.) |
97 | (a) Refrigerator of any capacity and make. |
98 | (b) Water cooler of any capacity and make. |
99 | (c) Deep freezer of any make and capacity. |
100 | Supply only electric blower fan motor 1/20 HP 230 Volts single phase with 950 RPMsuitable for water cooler complete all as specified and directed. |
101 | S & F for Brass ball valve, 15 mm dia, ISI marked, high pressure with polythelene float (Wall thickness of floats is 1.5 mm ) and fly nut complete screwed for iron pipe or brass ferrule and fixed, minimum finished weight 0.28 Kg each ball valve as specified in SSR Part I including removal of extg unsv one complete all as specified and directed. |
102 | S & F for Push Cock of size 15mm bore ,Chromium plated,cast copper alloy, heavyduty,screwed for iron pipe or for brass ferrule including removal of extg unsv one complete all as specified and directed. |
103 | S & F for thermostat suitable for water cooler of capacity 40 ltr to 300 ltrs for 230 volt 50 Hz AC including removal of extg unsv one complete all as specified and directed. |
104 | S & F for condensing coil suitable for water cooler of capacity 40 Ltr/hr cooling capacity as per existing including removal of extg unsv one complete all as specified and directed. |
105 | S & F for condensing coil suitable for water cooler of capacity 60 Ltr/hr cooling capacity as per existing including removal of extg unsv one complete all as specified and directed. |
106 | S & F for PVC drain out pipe 32 mm dia bore medium grade as per existing including providing necessary GI clamps, nut bolt etc including removal of extg unsv onecomplete all as specified and directed.Make : Prayag /Supreme/Prince |
107 | M & L for preparation of old steel surfaces by using wire brush /emery paper etc and making the surface smooth by using putty and painting to the outer Cover/external surfaces of water cooler with two coats of synthetic enamel paint and re-writing the SM / MES No etccapacity of water cooler 40/60 Ltr/hrcomplete all as specified and directed. |
108 | S & F for PVC connection of 450mm long, 15mm bore with chromium plated brass check nuts at both side of superior quality including removal of extg unsv one complete all as specified and directed. |
109 | Removing the old unserviceable sealed compressor unit from water cooler of 40/60/80 ltrs capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas and oil to adequate level ,and testing complete all as specified and directed. Make of compressor : Shriram / Kirloskar / Usha |
110 | S & F for MCB Protected Socketed with sheet enclosure SRCD (Socket residual current device) single pole and neutral enclosure with a two pin and earth plug and socket complete with 20 Amps MCB single pole. |
111 | TakingoutRefrigerator of any capacity andmake from the site for servicing, Cleaning of evaporator coil, condenser coil, vegetable tray, checking the electrical circuit and replacementof unserviceable spare parts like indicatorlamp,evaporator coil , relay as required, testing for smooth functioning etc complete all as specified and directed. Note :-Supply only spare parts shall be measured and paid separately under relevant Items given below. |
112 | Supply only bio metallic fuse for double door refrigerator of any make and model as per site requirement complete all as specified and directed. |
113 | Supply only timer switch for double door refrigerator of any make and model as per site requirement complete all as specified and directed. |
114 | Supply only indicatorlamp ofrefrigerator, any watt, thread/ pin type as per site requirement complete all as specified and directed. Make -Bajaj/Philips/ Surya. |
115 | Supply only evaporator coil for Refrigerator of any type & capacityas per existing and complete all as specified and directed. |
116 | Supply only relay suitable for refrigerators of different capacities and makes for smooth functioning of refrigerator as per existing and complete all as specified and directed. |
117 | S & F for condensing coil for Refrigerator of any type & capacity as per existing including removal of extg unsv one as directed |
118 | S & F for thermostat for Refrigerator of any type & capacity as per existing including removal of extg unsv one complete all as specified and directed. |
119 | S & F for Chiller door of approved brand, for refrigerator of any make and capacity 165/180 ltr as ordered and suitable for fitted with existing cooling chamber of Refrigerator including removal of extg unsv one complete all as specified and directed . |
120 | S & F for Chiller door of approved brand, for refrigerator of any make and capacity 220/ 250 / 300/ 310 ltr as ordered and suitable for fitted with existing cooling chamber of Refrigerator including removal of extg unsv one complete all as specified and directed . |
121 | S & F for Chiller tray of approved quality/ Brand suitable for 165/ 180/ 220/ 250/ 300/ 310 Ltr cap refrigerator including removal of extg unsv one complete all as specified and directed |
122 | S & F for Vegitable / Fruit tray of approved quality / Brand suitable for 165/ 180/ 220/ 250/ 300/ 310 Ltr cap refrigerator including removal of extg unsv one complete all as specified and directed. |
123 | S & F for Magnatic door gasket any make ofrefrigerator of capacity 165 to 300 ltr including removal of extg unsv one complete all as specified and directed. |
124 | M & L for preparation of old steel surfaces by using wire brush /emery paper etc and making the surface smooth by using putty and painting to the outer Cover/external surfaces of refrigerator of capacity 165/170/200 Ltr with two coats of synthetic enamel paint and re-writing the SM/MES No etc complete all as specified and directed. |
125 | M & L for preparation of old steel surfaces by using wire brush /emery paper etc and making the surface smooth by using putty and painting to the outer Cover/external surfaces of refrigerator of capacity 250/286/300 Ltr c Ltr with two coats of synthetic enamel paint and re-writing the SM/MES No etc complete all as specified and directed. |
126 | Removing the old and unserviceable sealed compressor unit from refrigerator 310/300 ltr capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas as per existing for Refrigerator in exchange of defective uncut sealed unit including making connection and oil at adequate level and testing complete all as specified and directed. |
127 | Taking out Deep freezer of capacity 165/200/310 Litresfrom the sitefor servicing,applying one coat of synthetic enamel paint in side, cleaning of evaporator coiland condenser coil, checking the electrical circuit and replacementof unserviceable spare parts thermostat , Over load protection,relay, starting capacitor, running capacitor, testing for smooth functioning etc.complete all as specified and directed. Note :-Supply only spare parts shall be measured and paid separately under relevant Items given below. |
128 | Supply only thermostat suitable for deep freezer of capacity 165 ltr to 300 ltrs for 230 volt 50 Hz AC supply complete all as specified and directed. |
129 | Supply only Over load protection suitable for deep freezer of capacity 200/300/310 Ltrs as per existing complete all as specified and directed. |
130 | Supply only relay suitable for deep freezer of any capacity as above as per existing complete all as specified and directed. |
131 | Supply only starting capacitor suitable for deep freezer of any capacity as above complete all as specified and directed. |
132 | Supply onlyrunning capacitor suitable for deep freezer of any capacity as above complete all as specified and directed. |
133 | S & F for Magnatic door gasket any make ofdeep freezer of capacity 165 to 310 ltr including removal of extg unsv one complete all as specified and directed. |
134 | Removing the old and unserviceable sealed compressor unit from deep freezer 310 /300 ltr capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent for deep freezer in exchange of defective uncut sealed unit including making connection and charging of non CFC refrigerent gas and oil at adequate level and testing complete all as specified and directed. Make: Shriram/ Kirloskar/ Usha |
135 | S & F for wood saving padsof desert coolers including taking out of old pads including removal of extg unsv one complete all as specified and directed. |
136 | S & F for tullu pump 0.6 KW, 1.25 Mtr head of desert cooler suitable for operation on 230 volt 50 Hz AC supply including removal of extg unsv one complete all as specified and directed. |
137 | S & F for blower motorof 1/8 HP, 1460 RPM for existing desert cooler suitable for operation on 230 volt, 50 Hz, AC supply including removal of extg unsv one complete all as specified and directed. |
138 | Supply and fix voltage stablizer with digital display for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 voltswith accuracy of+ 2.5% and capacity 5 KVA suitable for AC complete all as specified. |
139 | Supply and fix voltage stablizer with digital display for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 voltswith accuracy of+ 2.5% and capacity 4 KVA suitable for AC complete all as specified. |
140 | M & L Attending emergent complaints i.e Air conditioners any type , Window type Airconditioner any type, water cooler any type, Refrigerator any type, Deep freezers any typeincluding carrying out minor repairs like loose connection as required to make the system in order/ functionalcomplete all as specified and directed. |
141 | M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including PVC casing and capping heavy duty ISI marked and itsaccessoriesincluding one run of single core 4 sqmm PVC insulatedunsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removal of extg unsv one c complete all as specified and directed. Note:- Two runs of 4 sqmm cable,one run of 4sqmm cable and one run of PVC casing caping will be measured as one unit. |
142 | Supply and charging Gas R-22 for Air conditioner of any type make and capacity complete all as specified and directed. |
143 | Supplyand Charging of non CFC Refrigerant Gas R -134 to water cooler, refrigerator and deep freezer of any type, make and capacity complete all as specified and directed. |
144 | Supplyand Charging of non CFC Refrigerant Gas R -410/407/32all as specified and directed. |
145 | Removing the old and unserviceable sealed compressor unit from refrigerator 165 to 265 ltr capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent including supply andcharging of non CFC refrigerent gas as per existing for Refrigerator in exchange of defective uncut sealed unit including making connection and oil at adequate level and testing complete all as specified and directed. |