| 1 | Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dusts etc. Complete all as specified and directed by Engineer-in-Charge. |
| 2 | Material and labour for machine cut Kota stone slab of size 550x550mm and 18 to 20 mm thick as in flooring, laid over cement screed base 20mm thick in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing, including pattern work with 150mm wide white marble strips complete all as specified and directed by engineer-in-charge. |
| 3 | All as per item No 2 above but laid/fixed over in vertical surface over and incl and provision of 10 mm thickcement plaster inCM (1:4) back coat Complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for old decorated surfaces plastered or unplastered surface of wall and applying two coat of oil bond distemper over one coat ofwall care putty on wall Complete all as specified and directed by Engineer-in-Charge. |
| 5 | Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm Complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors Complete all as specified and directed by Engineer-in-Charge. |
| 7 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth Complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fix in repairs vitreous china wash hand basin (flat back) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste fittings Complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe ) complete all as specified and directed by Engr-in-Charge. |
| 10 | Supply and fix in repairs PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) Complete all as specified and directed by Engineer-in-Charge. |
| 11 | S&F in repairs PVC waste pipe 32 mm dia for wash hand basin, Complete all as specified and directed by Engineer-in-Charge. |
| 12 | S & F in repair 15 mm dia 600mm long PVC connectionswith brass check nut Complete all as specified and directed by Engineer-in-Charge. |
| 13 | S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferruleComplete all as specified and directed by Engineer-in-Charge. |
| 14 | S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, Complete all as specified and directed by Engineer-in-Charge. |
| 15 | S&F in repairs 15 mm dia pillar taps, fancy type brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed Complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and fix in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.Complete all as specified and directed by Engineer-in-Charge. |
| 17 | S & F in repairtowel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc Complete all as specified and directed by Engineer-in-Charge. |
| 18 | Demolition of stone slab and tiles of any description or thickness in floor apron etc Complete all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white oroloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) Complete all as specified and directed by Engineer-in-Charge. |
| 20 | M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) Complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for Non - skid Ceramiccolourtiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white oroloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) Complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thickin floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match Complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thickin vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to matchComplete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for 18 -20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed in CM 1:6. Complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply & fixing in replacement of white cover plate with frame 6 module complete all as specified and directed by Engineer in charge. |
| 27 | Supply & fixing in replacement of white cover plate with frame 8 module complete all as specified and directed by Engineer in charge. |
| 28 | M&Lswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified. |
| 29 | M&L Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete. |
| 30 | M&L switch Modular type 16 Amps 1Way, 1 module with modular plat, 230V AC complete. |
| 31 | M&L modular stepped type electronic fanregulator 120W, 2 module complete . |
| 32 | M&L Switch piano flush button type single pole one way 6 Amps complete all as specified. |
| 33 | M&L switch piano flushbutton type single pole 16 Amps complete all as specified. |
| 34 | M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified. |
| 35 | S&F ceiling rose surface PVC type with three terminals complete all as specified and directed . |
| 36 | S & F LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 37 | S & F LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level =100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 38 | S & F LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria,Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 39 | S & F surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level = 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driverwithvoltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 40 | S & F 35 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected with IK05 impact resistance.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 25 mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed. |
| 41 | S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified. |
| 42 | S & F LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified. |
| 43 | S&F Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 4 sqmmcable shall be measured as one RM. |
| 44 | S&F Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed.Note: Three runs of 6 sqmmcable shall be measured as one RM. |
| 45 | S&FSub main wiring with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 10 sqmmcable shall be measured as one RM. |
| 46 | S & F MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting . |
| 47 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 48 | S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer-in-Charge. |
| 49 | M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for fixing in replacement safety pressurevalve (as per sample)for geysers complete all as directed by Engineer-in-charge. |
| 51 | S&F heating element of 2 KW,(as per sample) with nut bolt washercomplete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F heating element of 1.5 KW (as per sample) with nut bolt washercomplete all as specified and directed by Engineer-in-Charge. |
| 53 | S&F of thermostat for 25/35/50 ltrs capacityof geysers complete all as specified and directed by Engineer-in-Charge. |
| 54 | M&L plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F in replacement inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge. |
| 56 | Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity andcarrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire as per suitable length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge. |
| 57 | Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 56 and 57(a) Supply only spares shall be measured and paid under relevant item of Sch \"A\"/ BOQ(b) Contractors are advised to visit the sites before quoting their rates.(c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (d) Contractorshall provide and deploy adequate experienced Exp. professionalto carry out day to day complaints and tradesman will remain presentin mention areaComplainet Cell from 9:00Hrs to 1700 Hrs from Monday to Sunday (01 Electrcian & 01 Helper) .In case of any breakdown/ emergency, contractor shallmake arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also.The rates quoted in sch \"A\" respective items shall be deemed to be included and nothing extra shall be admissible on this account.Note:whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (e) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 8 hours. |
| 58 | Supply only replacement of capacitor 2.5 Mfd,240 V complete all as specified and directed. |
| 59 | Supply only in replacement batten holder including with connections complete all as specified and directed. |
| 60 | Supply only in replacement switch piano6amp SP two way,ISI marked. |
| 61 | Supply only in replacement socket piano outlet6 Amp flush button type all as specified |
| 62 | Supply only Ceiling fan regulator electronic step switch type 120 Watt 230/250 Volts single phase complete.: |
| 63 | Supply only in replacement Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge. |
| 64 | Supply only in replacement Modular socket outlet 5 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 65 | Supply only in replacement swich & socket combined3 pin 6 Amp sp . |
| 66 | Supply only in replacement swich & socket combined 5 pin 16 Amp sp. |
| 67 | Supply only in replacementElectric bellAC 230 Volt etc complete all as specified and directed. |
| 68 | Supply only in replacementMCCB 160Amp 4 pole 36 KA at 415 V with fixed thermal magnetic release complete all as specified directed. |
| 69 | Supply only in replacementMCCB 125Amp 4 pole 16 KA at 415 V with fixed thermal magnetic release complete all as specified directed. |
| 70 | Supply onlyin repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ \"B\" curve complete. |
| 71 | Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified. |
| 72 | Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified. |
| 73 | Supply only in replacementheating element of 2 KW circular type with nut bolt washercomplete all as directed. |
| 74 | M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed. |
| 75 | Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :- |
| 76 | Sheet 4\" x 4\" single cutting suitable for one piano switch |
| 77 | Sheet 4\" x 4\" two cuttings suitable for two piano switches |
| 78 | Sheet 4\" x 7\" three cuttings suitable for three piano switches |
| 79 | Sheet 4\" x 7\" one cutting for 6 Amp socket and two cuttings for piano switches |
| 80 | Sheet 8\" x 10\" incl cuttings for switches and sockets 6/16Amps as directed. |
| 81 | Sheet 10\" x 12\" incl cuttings for switches and sockets 6/16Amps as directed. |
| 82 | Supply only in replacement recessed mounting LED FLAT panel 2\"x2\" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed. |
| 83 | Supply only in replacement 12 MODULE plate suitable for modular switch and socket in white colour. |
| 84 | Supply only in replacement 4 MODULE plate suitable for modular switch and socket in white colour. |
| 85 | Supply only in replacement 3 MODULE plate suitable for modular switch and socket in white colour. |
| 86 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 87 | Taking down care fully copper/aluminium point wiring from wooden batten (except) conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 88 | Taking down old MCCB , TPN DBs , SPN DBs,& main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. |
| 89 | Taking down old submain wiring of any size, including coduit and make from the site complete all as specified. |
| 90 | Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified. |
| 91 | Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed / surface PVC conduits as suitable of site(Medium grade) of size not less than 20 mm dia incl proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matchingall as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, 3 mm thick hylem sheet cover for terminal boxespainted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories forPVC insulated & unsheathed cable as in earth wire connected to common earth dolly completeall as specified and directed. Make: Make: Gloster/Havells/ Polycab/Finolex (Premium)/RR Kabel |
| 92 | All as per item No 85 above but one light/fanpoint controlled by one switch. |
| 93 | All as per item No 85 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 94 | All as per item No 85 above butOne 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 95 | All as per item No 85 above butOne bell point controlled by one bell push. |
| 96 | All as per item No 85 above but One light point controlled by two Nos two way switches |
| 97 | All as per item No.85 above but point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 6 pin 15 Amps socket out let on independent board. |
| 98 | M&L switch piano flush type 5 Amp SP one wayISI marked complete all as specified. |
| 99 | M&L switch piano flush type 5 Amp SP two way |
| 100 | M&L switch piano flush type 15 Amp SP one wayISI marked complete all as specified. |
| 101 | M&L socket outlet 5 pin 5 Amp flush typeISI marked complete all as specified. |
| 102 | M&L socket outlet 2 in 1,3 pin 5/15 AmpsISI marked complete all as specified |
| 103 | M&L bell electric (ding dong) 230 volt, SPall as specified and directed. |
| 104 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked not less than 20 mm dia and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified. |
| 105 | All as per item No 93 above but one light /Ceiling fan/exhaust fan point controlled by one switch. |
| 106 | All as per item No 93 above but one bell point controlled by one bell push. |
| 107 | All as per item No 93 above but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 108 | All as per item No 93 above but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 109 | All as per item No 93 above but one light point controlled by two Nos two way switches |
| 110 | M&Lpoint wiring with PVC unsheathed multi stranded copper conductorcable 4.0 sqmm FRLS 1100 Volts in New PVC concealed conduitmedium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 4.0 sqmm FRLS 1100 Volts copper conductor cableas earth continuityconnected to common earthfor one 15 A switch socket power point, all as specified |
| 111 | Supply & FixModular five stepped type electronic fanregulator 2 moduleISI marked230V AC complete all as specified. |
| 112 | M&L bell electric (ding dong) 230 volt, SPall as specified and directed. |
| 113 | S & F in replacement of decorative type wall mounted luminaire (comet) with under take poly carbonate material suitable for 1 x 14 watts LED bulb B-22 base complete all as specified and as directed |
| 114 | S&F angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete. |
| 115 | Refixing of Ceiling fan / exhaust fan/ fresh airincluding taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only. |
| 116 | M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. |
| 117 | S&F in replacement gun metal bush of any size and make sutiable for ceiling fans 1200 mm compete all as specified and directed. |
| 118 | S&F in replacement ball bearing No. 6202./6203 |
| 119 | S&F in replacement worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed. |
| 120 | S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed. |
| 121 | M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dustetc.and endorsement of fan no.with black synthetic enamel paint complete all as directed. |
| 122 | S&F in replacement exhaust fan motor capacity 1/4 HP 230 volts suitable for 300 mm size exhaust fan complete all as directed. |
| 123 | Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed.Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only. |
| 124 | S&F in replacement only base plate assembly (confirming to ISI ) complete for25/35 Ltrs capacity copper tankgeyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusiveofclamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed. |
| 125 | S&F in replacement of thermostat for 25/35/50 ltrs capacityof geysers complete all as directed. |
| 126 | S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. |
| 127 | Supply and fixMCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complet |
| 128 | M&L MCB SP 6 to 32 Amp \"C\" curve all as directed. rand |
| 129 | Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 130 | S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete. |
| 131 | S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete. |
| 132 | M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts,check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed |
| 133 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wirecomplete all as specified. |
| 134 | Schedule of Credit |