Tender For Covering The Existing Open Shelter From Three Sides Of The Porta Cabin In Aviation Spares At Arc Mahipalpur, Replacement Of Old/ Unsv Lights With New Led Light And New Led Strip Lights At 11Th Floor Q Branch, Conf Room, Lift Lobby, Corrido, delhi-Delhi

Military Engineer Services-MES has published Tender For Covering The Existing Open Shelter From Three Sides Of The Porta Cabin In Aviation Spares At Arc Mahipalpur, Replacement Of Old/ Unsv Lights With New Led Light And New Led Strip Lights At 11Th Floor Q Branch, Conf Room, Lift Lobby, Corrido. Submission Date for this Tender is 22-04-2024. LED Light Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43078249
Tender For Covering The Existing Open Shelter From Three Sides Of The Porta Cabin In Aviation Spares At Arc Mahipalpur, Replacement Of Old/ Unsv Lights With New Led Light And New Led Strip Lights At 11Th Floor Q Branch, Conf Room, Lift Lobby, Corrido
Limitted
Indian
Delhi
delhi
22-04-2024

Tender Details

Covering The Existing Open Shelter From Three Sides Of The Porta Cabin In Aviation Spares At Arc Mahipalpur, Replacement Of Old / Unsv Lights With New Led Light And New Led Strip Lights At 11Th Floor Q Branch, Conf Room, Lift Lobby, Corridor => Limited

Key Value

Document Fees
INR 500 /-
EMD
INR 68260.0 /-
Tender Value
INR 34.13 Lakhs /-

BOQ Items

Name of Work:COVERING THE EXISTING OPEN SHELTER FROM THREE SIDES OF THE PORTA CABIN IN AVIATION SPARES AT ARC MAHIPALPUR, REPLACEMENT OF OLD/ UNSV LIGHTS WITH NEW LED LIGHT AND NEW LED STRIP LIGHTS AT 11TH FLOOR Q BRANCH, CONF ROOM, LIFT LOBBY, CORRIDOR, LIFT LOBBY OF 5TH FLOOR, ROOM NO. 578, 113, 805 AND FOYER AREA AT NBC, PROVN OF FALSE CEILING IN CERTAIN ROOMS AND CORRIDOOR OF "F" BLOCK (RESTRICTED AREA) UNDER GE (SOUTH WEST) NEW DELHI-03
Sl. No. Item Description
1S&F Prefab shelter ofsize 15.00m x5.00m, with 4.00 metre height from floor level to bottom of truss from three sides with following specifications including all fitting and fixture complete all as shown in drawing, as specified & as directed. Make: M/s Porta Cabin Engineers Pvt Ltd/ Shree Porta Builders Pvt Ltd/ M/s Startrek Structures/ M/s Makeover Interiors/Genesis India/Kanchan Enterprises
2(i) Foundation/ platform:- Prefab shelter shall be placed on PCC Platform. Dwarf walls Shall be provided all-around of shelter. Foundation of dwarf wall shall be 300mm below GL as shown in drawings. RCC Plinth bend of size 250 x 300 mm shallbeprovided over the dwarf wall. Necessary fixing arrangement (Anchor plate and Anchor bolts etc) for prefab shelter shall be provided as per manufacturer"s instructions. 75 mm thick PCC 1:4:8, type D-2, using 40 mm graded stone aggregate over and including consolidated earth filling shall be provided for Platform.Overall height up to top of PCC 1:4:8 shall be300 mm from Ground level.
3(ii) Walls:- Supporting framework made with mild steel hollow pipe, which size 37x37mm 18-20 gauge coated with synthetic enamel primer. Infill material of two layer which one layer of outside with 6mm Cement Board and from inside with 6mm Cement Board complete all as per manufacturer"s instructions. Insulation : Insulation will be done with 38 density thermacol.
4(iii) External/Internal Painting:- All steel surfaces shall be painted with two coats of synthetic enamel paintover and including a coat of red oxide primer. All internal surfaces of wall shall be painted with two coats of oil bound distemper over and including a coat of cement primer. The external surfaces of walls shall be painted with two coats of weather proof exterior emulsion paint (Apex Ultima) over and including a coat of cement primer.
5(iv) Window:- All Windows shall be Powder coated aluminium sliding glazed windows with 5 mmthick tinted glass.Stainless steel mosquito proof wire netting & Aluminium Deco grillshall be provided on all windows and Vents.Size of window shall be1.20m x 1.20m (03 Nos).
6Supply, installation, testing and commissioning new rolling shutter made out of 1.25mm (18 SWG thick) MS Laths/side guides made out of 100 x 25 x 3.15mm MS Section/bottom lock plate made out of 2.50mm MS Stripes with MS angle iron of size 35 x 35 x 5 mm at the bottom/top brackets made out of 5mm thick MS plate/main top/shaft made out of heavy duty MS seamless pipe (without springs) duly covered with top cover made out of 20 SWG thick joint less GI sheet and all accessories duly painted with two coat of synthetic enamel paint of approved shade over and including a coat of red oxide zinc chromate primer all as per standard engineer practice/site requirement, gear operated type with chain wheel and hand chain including making goods to all disturbed surface complete all as specified and as directed. Note: (a) The cost of transportation of rolling shutter from factory to site shall deemed to be included in the unit rate of item. (b) The rates are included for demolition and cement/concrete/brick work which is required at site for replacement of rolling shutter.
7M&L two coats of Aluminium paint from existing surface of any description over 10cm in width or girth over one coat of aluminium red oxide primer after complete removal of existing paint complete all as specified.
8M&Lin replacement of point wiring for modular switches or normal switches with 2X1.5 sqmm, single core, multi stranded copper conductor PVC insulatedunsheathed cable 1100 Volts grade, drawn through concealed rigid non-metalic PVC Conduit with all fittings of suitable size of dia as required at siteincluding cadmium plated screws as per IS and replacement of 3 mm thick phenolic laminated sheet top covers, modular cover plate on and includingsunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/fan point controlled by one switch 5 Amps one way single pole complete all as specified and directed. Make of cable-Havells/Standard/Polycab.
9All as per item No. 4 above but one three pin 5 Amps socket out let on independent board. Make of cable-Havells/Standard/Polycab.
10All as per item No 4above but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sq mm PVC insulated unsheathed copper cable as earth continuity conductor.
11All as per item No. 4 above but, point wiring of copper cable multi stranded 2x2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed. Make - Havells/Standard/Polycab.
12S&FModular switch 1 way 6 A, 240 volt, 1 modulecomplete all as specified and directed. (Make : Anchor Roma /Legrand/Crab tree)
13S&FModular switch 1 way 16 A, 240 volt, 1 modulecomplete all as specified and directed. (Make : Anchor Roma /Legrand/Crab tree)
14S&FModular socket outlet 6 A240 volt, 2/3 pin , combined 2 modulecomplete all as specified and directed. (Make- Anchor Roma/Legrand/Crab tree)
15S&FModular socket outlet 16 A240 volt, 2/3 pin , combined 2 modulecomplete all as specified and directed. (Make- Anchor Roma/Legrand/Crab tree)
16S&F in replacement LED Recess mounted 2x2 ft luminaire fitting LED 34/36 Watt cast aluminium housing, toughened glass, silicon gaskett, 6000K high power LED with lens for uniform distribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed. (Make - Havells Cat No:- PLUTONEO2X2PLR34WLED857Sor equivalent in philips/Wipro)
17M&Lin replacement Sub main wiring complete with4 run of 10 sqmm , single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade, drawn including PVC concealed/surface conduitalong walls roofs etc including 10 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.Make - Havells/ Finolex/ Polycab/Plaza/L&T/ANCHOR
18Supply & Fixingin replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP 25 Amp of capacity 20P+E Amps complete all as specified and directed.Make- Havells/ Legrand/ L&T/ Schneider
19S&F electric driven Invertor type SplitAir Conditioner 2Ton capacity,240 volts, BEE 5 star ratedincluding rotary type compressor, high EER, copper material condenser unit, eco friendly refrigerent etc with all accessories complete in all respect all as directed (Make : Hitachi/LG/Voltas/Blue Star)
20S&F ceiling rose 2 to 3 terminals 6 Amp,240 v0lt, and connection complete all as specified.
21Supply and fixingDB VTPN 4way IP 43 IK-09 with metal double door suitable forProvision of MCCB 125 Amp, housing MCB"s complete and making good disturbed surface all as specified and as directed. Make : Legrand/Schneider/Hager/Simens.
22Supply only in replacement of MCBTPN (FP) 100 Amps 25 KA complete all as specified and directed Make : Legrand/Schneider/Hager/Simens.
23Supply only in replacement MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, "C" curve and connection by using suitable copper lugs completeMake : Legrand/Schneider/Hager/Simens.
24S&F MCCB 4 Pole,100 Amps 415 volt, AC, fixed type, with breaking capacity 16 KA with incoming and outgoing spreader extentions and Aluminium lugs suitable for load line DB & connection complete of rating:- Make : Legrand/Schneider/Hager/Simens.
25Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) ®
26M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead(upto the body ofthe equipment) by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 15 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 ofSSR 1991(Part-I) complete.
27Supply & lay or fixing or passing through pipe or in cable ducts, 1100 volts grade,XLPE, armoured, electric power cables (heavy duty) with aluminium conductorof 16 Sqmm including dismantling old defective one.
28Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft and loose soil complete all as specified and directed.
29Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
30Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
31M&L for Sand cushioning/sand coveringfor underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
32Supply and laying sub class "B" bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engr-in-Charge.
33Taking down copper/ aluminium point wiring (light, fan) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.
34S&F in replacement LED Recess mounted 2x2 ft (595mm X 595mm and ht 70mm as per site requirement) luminaire fitting LED 34/36 Watt CRCA powder coated white after phosphochromate treatment type housing, high efficiency with lumen efficacy of =140 lm/W, toughened glass, silicon gasket, 3000K to 6500K (as per site requirement) colour temp (warm white), radiation free (as UV & IR radiations), operating voltage 140V-270V, 50/60 Hz, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and as directed.
35S&F in replacement energy efficient flood light of 100 watt with electronic driver (isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open / short circuit protection, over voltage protection, surge voltage protection with SPD (10 kV) & other safety test as per IS 15885 Part-2/Sec 13), anti glare diffuser, mercury free, UV/IR radiation free, operating voltage 140V to 270V, lumen efficacy of LED >130 lm/W and viewing angle of 120° to ensure better uniformity,IP-65 incl connection with MS craddle of thickness 5mm complete all as specified and as directed.
36S&F in replacement LED surface mounted 1x1 ft (295mm X 295mm X 70mm) luminaire fitting LED 18 Watt CRCA powder coated white after phosphochromate treatment type housing, high efficiency with lumen efficacy of =140 lm/W, toughened glass, silicon gasket, 3000 to 6500K colour temp (warm white), radiation free (as UV & IR radiations), operating voltage 140V-270V, 50/60 Hz, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and as directed.
37S&F in replacement of energy efficient LED Round/square shape recess mounted downlightfitting 15 Watt, 140V-270V, 3000 K to 6500 K couler temp, dia 177mm, hight 55mm white powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient heat dissipation & white finish ABS ring for holding the diffuser complete all as specified and as directed.
38S&F in replacement of energy efficient LED Round/square shape recess mounted downlightfitting 18 Watt, 140V-270V, 3000 K to 6500 K couler temp, dia 210 mm, hight 23mm white powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient heat dissipation & white finish ABS ring for holding the diffuser complete all as specified and as directed.
39S&F in replacement of energy efficient LED Round/square shape recess mounted downlightfitting 10 Watt, 140V-270V, 3000 K to 6500 K couler temp, dia 138mm, hight 23mm white powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient heat dissipation & white finish ABS ring for holding the diffuser complete all as specified and as directed.
40S&F in replacement of energy efficient LED Round shape recess mounted downlight/ spotlight fitting 6 Watt, 140V-270V, 3000 K to 6500 K couler temp, dia 78mm, hight 42mm white powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient heat dissipation & white finish ABS ring for holding the diffuser complete all as specified and as directed.
41S&F in replacement of energy efficient LED Round shape recess mounted downlight/ spotlight fitting 2 Watt, 140V-270V, 3000 K to 6500 K couler temp, dia 36mm, hight 24mm white powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient heat dissipation & white finish ABS ring for holding the diffuser complete all as specified and as directed.
42M&L for twin core flexible wire PVC insulated unsheathed FRLS copper conductor cable of size 0.75 Sq mm for voltage grade upto 1100 V complete all as specified and as directed.
43M&L for sub main wiring with two run of single core PVC insulated FRLS stranded copper conductor cable of size 2.5 Sq mm and one run of 2.5 Sq mm earth wire in PVC insulated FRLS copper conductor cable as earth continuity conductordrawn in and including PVC conduit concealed medium grade complete all as directed.
44M&L for sub main wiring with two run of single core PVC insulated FRLS stranded copper conductor cable of size 4.0 Sq mm and one run of 4.0 Sq mm earth wire in PVC insulated FRLS copper conductor cable as earth continuity conductordrawn in and including PVC conduit concealed medium grade complete all as directed.
45M&L for sub main wiring with two run of single core PVC insulated FRLS stranded copper conductor cable of size 6.0 Sq mm and one run of 6.0 Sq mm earth wire in PVC insulated FRLS copper conductor cable as earth continuity conductordrawn in and including PVC conduit concealed medium grade complete all as directed.
46S&F in replacement of RJ 11 telephone socket single module including suitable plate and cover all as specified and as directed. Make-Havells/ Finolex/ Legrand.
47Removing of existing serviceable fire alarm dectectors and refixing of same on falls ceiling without disturbing walls/connections cables and other accessories if required cost including in quoted rate complete all as specified and directed.
48Removing of existing serviceable sprinklers and refixing of same on falls ceiling without disturbing walls/connections flexible metal pipe and other accessories if required cost including in quoted rate complete all as specified and directed.
49S&F in replacement PVC non metallic conduit for repair of existing wiring of dia 20 mm and above including of all tees, bends, elbow reducers bell mouth tube end and fixing accessories such as coupler, lock nuts saddles, pipe hooks etc but exclusive of junction boxes all as specified and directed.
50M&L for removing the ceiling fan from existing position and refixing after proper cleaning, greasing and increasing the length of fan rod as per requirement complete all as specified and as directed.
51S&F new wall mounting fan 400 mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body incl connection complete all as specified and directed.
52S&F in repairs ventilating fan 250 mm sweep, 230 Volts, 1300 to 1400 RPM withhigh quality engineering plastic body and cuttingexisting hole to fit properly and making good distrubed surface and electric connection with three core flexile cable 1.5 Sqmm complete all as specified and directed.
53S&F in repairs heavy duty Exhaust fan 300 mm sweep, 230 Volts, copper wound motor, 1300 to 1400 RPM with louvers and cutting, cheasing existing hole to fit properly and making good distrubed surface and electric connection with three core flexile cable 1.5 Sqmm complete all as specified and directed.
54S&F in replacement SP&N enclosure with 2 pole and earth (2P+E) Metal Plug top & socket for incorporating 10 A - 20 A SP/DP MCB, 20 Amp, 240 Volts complete all as specified and as directed.
55S&F new flexion neo led strip 14.4W, 140-270V, 3000 K to 6000K, white/ warm white with suitable driver or RGB controller, IP20, surface/ recess mounting, flexible PCB material, instant start (less than 0.5 sec), mercury free, minimum 2 year warranty, CRI >80 complete all as specified and as directed.
56S&F mineral fibre ceiling boards 15 mm thick, 600 mm x 600 mm size including grid 25 x 25 x 1.6 mm thick GI powder coated wall angles and 25 x 35 x1.6mm size T runner suspended at 1200 mm centre to centre and cross T runner of 25 x 35 x 1.6mm size suspended at 600 mm centre to centre supported by 4 mm dia GI wire from roof/ slab including wall angle and T with interlocking arrangement as required for framing grid suitable for module size 600 mm x 600 mm ceiling etc complete all as specified and directed.(Make : Armstrong RH Dune 95 or Equivalent of Aerolite/Anchor)
57S&F as in repair GI metal false ceiling lay in plain regular edge white color tiles of size 595X595X0.5mm thick with 8mm drop made of GI sheet having galvanizing of min 120 gms/sqm (both side inclusive) & electro statically polyester powder coated of thickness 60 microns(min) including factory painted after bending ceiling grid shall be following min sizes:main T section (24X38X0.3mm 3m long), Cross T section (24X25X0.3mm 6m long), wall angle (24X24X0.3mm 3m long),hanger rod4mm dia,Adjust clip (85X30X0.8mm), soffit cleat (27X37X25X1.6mm), Dash fastener (12.5 mm dia) including dismantling of frame / grid work & ceiling board any type, size & position etc complete all as specified and as directed.
58S&F in replacement of Old Surface Mounted Lights with New LED Recess Mounted 2 x 2 Feet Luminaries fittings LED, 36 Watt, White/Worm White, cast Aluminium housing, toughened glass, Silicon gasket 5700K high power LED with lens for uniform distribution, pre-wired and electric connection with suitable size stranded copper flexible PVC insulated wire including clamps and nut & bolts for fixing complete all as specified and directed.Orient Cat Part No. LTRAQ-36-C-V0
59M&L for taking down carefully of Ceiling fan 1200 mm sweep from the ceiling hook with their hanging arrangement and wiring etc and re-installed the same at the place where directed inside the room including 1 x new MS Fan rod, 2/3 Feet Long, suitable size of fastners as per site requirement or any other modification required for hanging of these ceiling fan after completion of False ceiling work in the room complete all as specified and as specified.
60M&L for shifting of existing AC/Power/Switch Socket Combination/ switch boards /power boards etc including their wiring circuit with casing caping and replaced the old damaged casing caping/PVC conduit with new one of suitable size as per site requirement complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail