Tender For Repair And Maintenance To External Electrification, Lt/Ht Pole, Cable, Panel Including Other Connected Work At Drdo Estate Under Ge Rd Pashan, pune-Maharashtra

Military Engineer Services-MES has published Tender For Repair And Maintenance To External Electrification, Lt/Ht Pole, Cable, Panel Including Other Connected Work At Drdo Estate Under Ge Rd Pashan. Submission Date for this Tender is 23-04-2024. Electrical Maintenance Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43077831
Corrigendum : Tender For Repair And Maintenance To External Electrification, Lt/Ht Pole, Cable, Panel Including Other Connected Work At Drdo Estate Under Ge Rd Pashan
Open Tender
Indian
Maharashtra
pune
23-04-2024

Tender Details

Repair And Maintenance To External Electrification, Lt / Ht Pole, Cable, Panel Including Other Connected Work At Drdo Estate Under Ge Rd Pashan

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Apr-2024 BOQ CORRIGENDUM BOQ 23-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR AND MAINTENANCE TO EXTERNAL ELECTRIFICATION, LT/HTPOLE, CABLE, PANEL INCLUDING OTHER CONNECTED WORK ATDRDO ESTATE UNDER GE (I) R&D PASHAN
Sl. No. Item Description
1Taking down Insulators any type any description and depositing/ shifting store for safe custody or issue under schedule of credit complete all as specified and directed.
2Dismantling and taking down guarding wireand depositing/ shifting store for safe custody or issue under Sch of credit complete all as specified and directed.
3Taking out steel tubular swaged poles 11 metrelong and depositing/ shifting store for safe custody or issue under schedule of credit complete all as specified and directed.
4Dismantling and taking down HT OH line conductor and depositing/ shifting store for safe custody or issue under schedule of credit complete all as specified and directed.
5Dismantling cross arms / MSchannel from HT pole including clamps, nuts, bolts & washers complete all as specified and directed
6Supply and fix Pin type, porcelain, vitreouswhite, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade complete all as specified and directed.
7Supply and fix insulator shackle type, porcelain, vitreous, white, brown or green insulator including galvanised and mild steel straps of size 31x5mm, washers, insulator bolts, washers and nuts, size of insulator 100 mm height, 115 mm dia with 14 mm dia bolts for 1100 Volts grade complete all as specified and as directed.
8Supply and fix Polymer Pin type insulator of 22 KV including necessary hardware complete all as specified and directed.
9Supply and fix Polymer disc type insulator, ball and socket type, white brown or green suitablefor 22KV including necessary hardwarecomplete all as specified and directed.
10Material and labour forCradles, hexagonal / rectangular, fabricated with galvanised steel wire 3.15 or 4 mm complete all as specified and directed.
11Supply and fix HTsteel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 11 metre long complete all as specified and directed. Note : Earth work will be measured and paid separately
12Material and labour foraluminium conductor steel reinfoced for over head line, fix on pole bringing the sag with in limit, fixing to the insulator by means of necessary binding with 14 SWG aluminium wire complete all as specified and directed.
13Material and labour forCross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size fixing to existing poleand inclusive of one primer coat, one under coat and one finishing coat of paint as indicated or complete all as specified and directed by Engineer-in-Charge.
14Repair and overhauling to gang operated air brake switch device upto 400 Amps,22 KV capacity including use of petrolium gelly for smooth functioning of all moving contacts of GOD complete all as specified and directed. Note : (i) Contractor shall provide all safety tools like HT hand gloves, ladder, rope, safety belt, helmet etc, T&P meggar, earth tester and other necessary tools required at site. (ii) Spares required to be replaced shall be measured and paide separately as "Supply only" and fixing charges for the same is deemed to include in the rates quoted for the items.
15Supply only Male contact/moving contact with blade arcing hornof gang operated AB switch devices suitable for 22 KV complete all as specified and directed
16Supply only Female contact /fix contact jaw arcing horn for gang operated AB switch devices complete all as specified and directed.
17Supply only Tinned copper flexible jumper 400/200 Amps of suitable length
18Supply only Post top Polymer insulators of gang operated AB switch devices complete all as specified and directed
19Supply only Middle post Polymer insulators of gang operated AB switch devices complete all as specified and directed
20Supply only Bottom post Polymer insulators of gang operated AB switch devices complete all as specified and directed
21Supply only MS jumper carrier complete all as specified and directed.
22Supply only GI pipe, heavygrade 25 mm dia made to shape for gang operating from ground complete all as specified and directed.
23Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LTunder ground cable and getting out in the following type of earth stata complete all as specified and as directed:- (a) Soft / Loose Soil
24(b) Hard/ Dense Soil
25(c)Soft/ Disintegrated rock
26(d) Hard Rock
27Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
28Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
29Material and labour for riddled earth filling in trenches to required width at bottom and top of cable as cushioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall only measured and paid.
30Supply and lay in trench reinforced precast concrete cable cover class HV type 2, flat size 300 x 180 x 40mm for cable protection complete all as specified and directed by the Engr-in-charge
31Material and labour forGI tube, , light grade with necessary fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed for the following size of pipe. Note : Excavation and earth work where required shall be measured separately.MSClamps for fixing on wall / pole , etc are included in the unit rate. (a) 100 mm dia bore
32(b) 80 mm dia bore
33(c)40 mm dia bore
34Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 95 Sq mm HT XLPE shielded core type wrapped with galvanised steel strip armoured (earthed), PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out ofmild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete including taking down existing unserviceable cable all as specified and directed. Note: Earthwork, cushioning and cable covers will be measured and paid separately.
35Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 185 Sq mm HT XLPE shielded core type wrapped with galvanised steel strip armoured (earthed), PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out ofmild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete including taking down existing unserviceable cable all as specified and directed. Note: Earthwork, cushioningand cable covers will be measured and paid separately.
36Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 sqmm,22 KV including taking down existing unserviceable joint complete all as specified and directed by Engineer-in-charge.
37Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,185 sqmm,22 KV complete including taking down existing unserviceable joint all as specified and directed by Engineer-in-charge.
38Material and labour forreplacement of outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, up to 3 core, 185 sqmm 22 KV complete all as specified and directed by Engr-in-charge. Make : M seal/ Denson/ 3M
39Material and labour forindoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, up to 3 core, 185 sqmm , 22 KV complete including taking down existing unserviceable joint all as specified and directed by Engr-in-charge.
40Cutting the tree branches which touches the LT/HT OH lines and 2.5 mtr away from centre line of HT/LT OH line span not exceeding 60 metrebetween poles and deposting the tree branches/leaves at 30 metre distance away from site.complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
41On load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap of sphere of oil testing by machine complete all as specified and directed. Note: .Oil samples are to be collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration to be deposited to AGE E/M office for records.
42Supply and topping up transformer oilof dielectric strength 50 KV at 4 mm gap in transformers of various capacity installed in various locations.complete all as specified and directed. Make of Transformer oil: Savitha/ Poweroil/ HP Notes : (a) New Transformer oil will be filled in the transformeronly after filteration and dehydration of existing transformer oil of the transformer.b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
43Supply & Fixed in repair of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
44Repairs to drop out fuse complete of upto 400 Amps,22 KV capacity including replacement of worn out nut bolts,washers,of suitable size /unserviceable spares and jumper connections for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares and jumper connections replaced will be measured and paid seprately as "Supply only"
45Supply only the following items:- (a) Top contact/L contact for drop out fuse. complete all as specified and directed
46(b) Lower contact for drop out fuse. complete all as specified and directed
47(c) Post insulators of drop out fuse.complete all as specified and directed.
48Material and labour for taking down burnt jumpers and material and labour for jumper connection between GOD and drop out fuses and transformer with jumper made with copper strip 20x3mm as a conductor duly insulated with GI nut bolt and washers both ends and PVC sleeves 22 kvgrade high tension, with colour code complete all as specified and directed Engr-in-Charge at site.
49Material and labour for checking of DC circuit complete from battery bank to HT panels for proper suppy to HT panel controls for smooth functioning of panels complete all as specified and directed.
50Material and labour for replacement of battery inter connecting lead /strip with terminal and nut bolt made from lead metal as per sample for connecting of batteries in series of 180/200 AH complete all as specified and directed at site.
51Material and labour for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs as per site requirementencased with polythylene sleeve, RYB colours of suitable dia complete all as specified and directed for :- a) Not exceeding 0.75 metre length.
52b) Exceeding 0.75 metrelength but not exceeding 1.5 metrelength.
53c) Exceeding 1.5 metrelength but not exceeding 2.5 metrelength.
54d) Exceeding 2.5 metrelength but not exceeding 3.0 metrelength.
55Supply install testing and commissioning in replacement of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts suitably tinned to withstand weather proof complete all as specified and as directed.
56Supply and fix in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete all as specified and directed by Engr-in-charge.
57Material and labour for preperation of old painted steel surface of 6/4/2 pole structure HT/LT street light/HT steel tublar poles 8.5/9.0/11/13metre long above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering complete all as specified and directed by Engr-in-charge for the following types:- a) HT 6 Pole structure 11 metrelong including channels, nut, bolts and clamps complete all as specified and directed
58b) HT 3 Pole structure 11 metrelong including channels, nut, bolts and clamps complete all as specified and directed
59c) HT 2 Pole structure 11 metrelong including channels, nut, bolts and clamps complete all as specified and directed
60d) HT pole 11 metrelong including channels, nut, bolts and clamps complete all as specified and directed.
61e) LT pole 8.5/9 metrelong including channels, nut, bolts and clamps complete all as specified and directed.
62Disconnecting the Polemounted/platform mounted outdoor type transformer situated at various sub station 22/ 0.433 KV 3 phase under DRDO Estate areaof any make and transporting to workshop for repairs/ rewinding, Dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections including tap changer switch connection on all 3 phase, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning.The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for 100 to 250 KVA complete all as specified and directed. Notes : (i) Copper winding wire/strip will be measured and paid separately as Supply only. (ii) Insulating oil for topping up will be measured and paid separately. (iii) Transportation of transformer for repair and re-installation including connection on HT & LT side, testing and commissioningis deemed to include in quoted rates. (iv) Test result to be submitted after testing of transformer
63Supply only super enamelled copper winding wire of various gauges or existing specifications for repair and rewinding of transformers HT coil with insulation including necessary class of insulation complete all as specified and directed.
64Supply only DPC copper strip of various gauges or existing specifications for repair and rewinding of transformers LT coil with insulation including necessary class of insulation complete all as specified and directed.
65Material and labour for carrying test for acidity of Transformer oil for various Transformers at DRDO Estaste andTest result to be submitted after test complete all as specified and directed by Engr-in-charge.
66Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifyingthe leakage by replacing the unserviceable spare parts of capacity 50 to 500 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system afterthe leakages have been rectified and tested on available electric load complete all as specified and directed. Note : (i)Defective parts replaced will be measured and paid separately as "Supply only"items here in after.(ii) Cost of required nut, bolts and washer to be included in quoted rates by contractor.
67Supply only LT bushings with brass studs of existing specification.
68Supply only top cover gasket set.
69Supply only radiator flanged gasket 6 mm thick.
70Supply only oil level indicator gasket set.
71Supply only HT bushing with stud22 KV of existing specification.
72Supply and fix 22 KV Cable Terminal protector Right anglebootto prevent flashover/short circuit due to intervention by Reptiles complete all as specified and directed by Engineer-in-Charge
73Material and labour for preparation of old painted surfaces of transformer, removingrusted scale/oil & painting of transformer with two coat of synthetic enamel paint of approved make duly Marking/ Writting MES/SM No. complete all as specified and directed by Engr-in-charge for : (a) 100 to 250KVA capacity of transformer.
74(b) 300 to 500KVA capacity of transformer.
75Material and labour for disconnecting HT incoming/ Out goingfor servicing, opening, draw out VCB trolley complete from its position and inspection of complete operating mechnical system, electrical wiring system of AC/DCand complete mechanical calibration of breakers including vaccum cleaning, oiling and greasing to all spares,Checking by draw out mechanism/arrangement of VCB, inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete a and Checking of alignment with spout and setting of contact gaps.complete all as specified and directed Note :- (i)Rate for removal of moisture from breaker by using vaccum cleaner and heating arrangement deemed to be included in quoted rate (ii) Major spare parts are to be paid separetly under supply only items here in after, however cost of minor spares shall be deemed to be included in item rate.
76Repair/Maint/Reconditioning of breaker In-Out trolly, including proper allignment of gate, wheel moving channel/rail, ramp ets,repairing of stopper pins, locking pins, replacement of damaged wheels, fixing base etc complete all as specified and directed.Note: Rate quoted is inclusive of necessary welding, bending, straightning work if required as per site requirement complete all as specified and directed.
77Material and labour for HT fuse for PT 22 KV 25 KA breaking capacity of rating as per existing for the particular HT panel as per existing shape and size tubular or box type complete with fuse holder all as specified and directed. Note: Fuse shall be checked at site and order shall be done as per sample. complete all as specified and directed.
78Supply only following spare parts:- (a)Spring charge motor single phase 110/220 volts
79(b)Closing Coil 110VoltDC
80(c)Tripping Coil 110Volt DC
81(d)Top spout with Busbar 22 KV.
82(e)Bottom spout with Busbar 22KV.
83(f) Power pack
84(g)Push button for open and Close.
85(h)Micro switches
86(j) Indication lamps.
87(k)Selector Switch
88(l) Heaters 200 watts single phase 220 volts along with thermostat suitable for existing to be connected on existing wiring circuits complete all as specified and directed.
89(m) Non hygroscopic, track resistance, high strengh epoxy Bus supporting insulators 22 KV as per existing size and shape complete all as specified and directed.
90Calibration and testing of combined inverse time over currentearth faultand instantaneous relay for checking and cleaning and ensure physical healthiness with visual check for healthy tripping of over current earth fault setting tripping timer ratio settinginstantaneous time setting etc as per installed capacityRMU/ Transformers with artifial current injection on primary and secondary with current injection complete all as specified and directed. Note :(a)Contractor will engage authorized persons for calibration of relay with all necessary equipment.(b)Record of relay setting time for each relay and breaker will be maintained by contractor and handed over to department.
91Supply and fixing of Touchproof joint22 KV of cable size 95 to 185 sqmm for RMU complete all as specified and directed by Engr-in-Charge.
92Material and labour for removing HT electrical connection at both end of 22 KV HT cable andHi-Pot Test carried out at any one end( High potential, high voltage test) with high voltage AC/DCInstrument and find out fault/weak points in the UG XLPE cablingsystemfor rectifying defects and test report to be submitted complete all as specified and directed Note: Quoted rate shall include for attending test without time restrictions.
93Material and labour for removing HT electrical connection at both end of 22 KV HT cable and Hi-Pot Test carried out at any one end ( High potential, high voltage test) with high voltage AC/DCInstrument and find out fault/weak points in the over head linessystem for rectifying defects and test report to be submitted. complete all as specified and directed Note: Quoted rate shall include for attending test without time restrictions.
94Material and labourfor removing HT electrical connection at both end of 22 KV structure/Vcb and HT Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DCInstrument and find out fault/weak points in the HT structure 2/4/6 poles and its controlling system for rectifying defects and test report to be submitted. complete all as specified and directed Note: Quoted rate shall include for attending test without time restrictions.
95Re-Stringingof HT/LT overhead conductor andearth conductors and visual testing of insulator, winding of ACSR as per requirement at site and GI earth wire guard/ earth conductors rigidly with winding wire complete all as specified and directed by Engr-in-charge.
96Supply and fix in repair CT 100-75/1 Amp class 1.0 burden 15VA secondary connection 1S1-1S2 suitable for HT 22 KV STC-25KA for 1 sec as per specification with installation calibration and testing complete all as specified and directed.
97Supply and fix in repair CT 100-50/1 Amp class 1.0 burden 15VA secondary connection 1S1-1S2 suitable for HT 22 KV STC-25KA for 1 sec as per specification with installation calibration and testing complete all as specified and directed.
98Supply and fix power connector accessoriesmade out of aluminium alloy according to IS:617 : 1975 and conforms toIS: 5561 : 1970 galvanic corrosion freeheavy duty working pressure 22 KV , enough to carry electrical load and to withstandthe mechanical forces imposed during installation as well as service condition and the arrangement of bolts, bolt & washerssuch that the pressure is uniformly distributed over the whole contact surfaced areacomplete all as specified and as directed for following type of clamps:- Make : Jaipuria Brothers (a) PG clamps suitableto connect conductor to conductor
99(b) Pad connector suitable to pin insulators and aluminium bus bar
100(c) T connectorsuitable to connect aluminium bus bar to conductor
101(d) Expansion type connector for multiple connection
102Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 2.50Ampere to 25 Ampere complete all as specified and directedMake : Jaipuria/ Biecco Lawrie
103Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 40 Ampere complete all as specified and directed. Make : Jaipuria/ Biecco Lawrie
104Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 75 Ampere Make : Jaipuria/ Biecco Lawrie
105Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 100 Ampere complete all as specified and directed Make : Jaipuria/ Biecco Lawrie
106Supply and fixingin repair HTRight angleboot 22 KV ratingon HT side of existing transformer for jointing 22 KV HT cable complete all as specified and as directed.
107Material and labour for disconnecting from existing main taking out from LT Panel boardforservicing & overhauling LT panel/ LT ACB panel of any make 400 to 1000 Amp, 50Hz 415V ACincluding taking out existing Mechanism complete with servicing of operating mechnism, testing of triping mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original position with all connections and testing complete all as specified and directed Note : Spare parts are to be paid separately under respective items here in after as Supply only.
108Supply only Following spare partssuitable for LT ACB suitable400A-1000 A Capacity complete all as specified and directed. (a) Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories.
109(b) Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB
110(c) Under voltage tripping device (UVT) 415 volts
111(d) Single phae CTS at rating 800/5A
112Supply and fixingin repair MCCB 4pole, 400 Ampere, 36 KA, 415 volts, over load and short circuit protection,adjustable thermal -magnetic release type complete all as specified and directed
113Supply and fixingin repair MCCB 4pole, 250 Ampere, 36 KA, 415 volts, over load and short circuit protection,adjustable thermal -magnetic release type complete all as specified and directed
114Supply and fixingin repair MCCB 4pole, 200 Ampere, 25 KA, 415 volts, over load and short circuit protection,adjustable thermal -magnetic release type complete all as specified and directed
115Supply and fixingin repair MCCB 4pole, 100 Amps, 25 KA, 415 volts, over load and short circuit protection,adjustable thermal -magnetic release type complete all as specified and directed.
116Supply and laying, connect, testingand commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings/walls without cable duct) complete including taking down unserviceable cable all as specified and directed by the Engr-in-Charge for the following :- Notes : (i) Excavation, sand cushioning, brick will be measured and paid separately under relavantitems. (ii) Cost of jointing material e.g. lugs, thimbles, glands, nut bolt and washers shall include in quoted rates. (a) 95 Sqmm 3.5 core
117(b) 70 sqmm 3.5 core
118(c) 50 Sqmm 3.5 core
119(d) 35 Sqmm 3.5 core
120(e)25 Sqmm 4 core
121(f) 16 Sq mm 4 core
122(g) 240 Sq mm 3.5 core
123Supply and lay in trenches reinforced precast concrete cable cover class LV, Type I, flat, size 250 mm x150mm x 40mm for cable protection complete all as specified and directed by the Engr-in-Charge.
124Material and labour for finding fault of UG cable aluminium conductor armoured of any size by fault locator complete all as specified and directed. Notes : (i) Excavation/earth work/returning filling/relaying of brick and relaying Soft Soil/ Loose Soilfor cushioning deemed to including in the rate quoted. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item.
125Material and Labour for straight through jointfor UG cable including joint kit for making joint suitable and complete all as specified and directed for the following size :- (a) 10 sq mm to 16 Sq mm, 4 core
126(b) 25 sq mm to 50 Sq mm, 3.5/4 core
127(c) 70 to 120 Sq mm, 3.5core
128Material and Labour for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations of stays and poles, copping of poles etccomplete including necessary form workweathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
129Material and labour for earthresistance value testing at various sub station complete all specified and directed by Engr-in-Charge : Note : Earth tester of suitable and necessary arrangement will be done by contractor.Note: Record of earth resistance value to be submitted to Engr-in-Charge.
130Material and labour for Earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 76 mm dia medium grade and inner pipe 32 mm dia including testing. 3 metrelong and having 100x 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm dia holes for nut bolts. buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.5 metredeep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32 x 6 mm strip with minimum two Nos of GI nut, bolts and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 Kg bags of carbon based earthing compound. The compound shall be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities! with ph value between 7-9, connected to the earthing test point, FRP fiber reinforced plastic pit cover square not less than 300x300x240 mm with pit cover, including necessary returning, filling and removal of extra soil complete all as specified and directed. Make: Approved Make NOTE: (i)GI strip beyond 7.5 metrewill be measured and paid sepeartely. (ii)Resistance of earthing should not more than 2 Ohm. Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user.Test results are to be written in letters of 20mm height in white colour on black paint back ground.If the desired result not obtained after testing, the contractor should do re-eathing without any extra cost to Govt.
131Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 32x6 mm size galvanised strip.complete all as specified and directed.
132Supply and fix LTsteel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 09 metre long complete all as specified and directed. Note : Earth work shall be measured and paid separately.
133Supply and fix in repairsLED street light /road way luminaries 45 watts with pressuredie cast housing heat sinkwith IP 66 protection, interchangeableelectronic driverhigh efficiency longer life, protection against high surges , high /low voltage cutoff,open/short circuit protection and high power factor LEDs as light source including fitted onexisting street light pole bracket complete all as specified and as directed. Make :Havells Cat ENDURASUNDOWNSL45WLED765PASYBOTG or Equivalent in CG/ Philips/Orient
134Supply and fix in repairsLED street light /road way luminaries 60 watts with pressuredie cast housing heat sinkwith IP 66 protection, interchangeableelectronic driverhigh efficiency longer life, protection against high surges , high /low voltage cutoff,open/short circuit protection and high power factor LEDs as light source including fitted onexisting street light pole bracket complete all as specified and as directed. Make: Havell"s Cat ENDURASUNDOWNSL60WLED765PASYBOTG or Equivalent inCG/ Philips/Orient
135Supply and fix in repairsLED 25Watt post top lantern (gate light) energy saving, environment friendly designed with symmetrical light distribution, spun aluminiumlandscape luminairewith high power LEDs as light source complete all as specified and directed. Make:- Havell"s cat part No RUBYPT25WLED830SSYMTOPC or equivalent inCG/ Philips/Orient
136Supply and fix in repairs LED Bollard fitting 10 Watt Sturdy IP 65 with excellent light out put through ITS PMMA window ensuring maximum illumination aspect in surrounding the rate shall beincluding PCC foundation of size .5x.3x.3 andcoping of size .3x.3x.3 metrecomplete all as specified and as directed.
137Supply and fix in repairs of street light bracket made out of 40mm dia light grade GI pipe of 1.5 metrelong bend to shape including single coat of aluminium pait over a coat of red primer painting complete all as specified and directed.
138Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 140x140x100mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminalfor loop in & loop out suitable for single phase street light systemincluding nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron complete all as specified and directed. Make : Sintex/National or equivalent
139Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 X 200 X 105 mm (internal ) comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminalfor loop in & loop out suitable for three phase street light systemincluding nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron complete all as specified and directed. Make : Sintex/National or equivalent
140Material and labour for3corePVC insulated sheathed copper conductor cable multistranded 3X1.5 sq mm passing through in steel pole DB to street light luminaires at any pole 2/4/9/11 metreheight includingreplacing the un serviceable cable. complete all as specified and as directed. Note : 3 runs of cable shall be measured as on length.
141Supply and fixingin replacement Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 8 kW single-Phase load .Contactor Rating: 40.Amps ( 2-pole ).MCB (single-pole) Rating:63.Amps (2 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T. Make:SWADEEP – 02EC 8kW1P/Suntech - ST 01.
142Supply and fixingin replacement Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kWload equally distributed over 3-phase .Contactor Rating: 40.Amps (4-pole).MCB (single-pole) Rating: 40.Amps (3 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (E-in-C Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T Make:SWADEEP – 02EC 12kW3P/Suntech -ST 02
143Material and labour for cutting ofroads/ plinth of width and depth n exc 0.25 metre complete all as specified and directed.
144Material and labour for PCC 1:2:4 typeB-1 by using20mm graded crushed stone aggregate for making good road/ foot path/ hard standing/ drain/ bldg plinth protection complete all as specified and directed.
145Material and labour for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 to 120 sqmm,22 KV complete all as specified and directed by Engineer-in-charge.
146Material and labour for repair/ fabrication of outdoor type LT panel doors of any size as site requirement with locking arrangement made out of any size / thicknessmild steel sheetand duly fixed/ weldedwith suitable size of butt hinges includingmaking good to the disturbed surface of panel complete all as specified and as directed.
147Material and labour for painting of out door type LT panel with synthetic enamel paint two coats over a coat of primer including preparation of surfaces complete all as specified and as directed.
148Material and labour for fabrication and installation of Glow Sign Board in size 1828.8mm x 1219mm x 177.8mm made of Flex/ Acrylic board, digital contents all as directed Engineer-in-charge at one side of the board, GI plain sheet, cubical open the flex/Acrylic board and suitable for mounting on wall /gate complete all as specified and directed by Engineer-in-Change. Note :- The cost of Fabrication and welding work is included in the quoted rate .
149Excavation in trenches not exceeding 1.5 metrewide and depth exc 1.5 metre and not exc 3.0metre getting out in the following type of earth stata complete all as specified and as directed:- (a) Soft / Loose Soil
150(b) Hard /Dense soil
151(c)Soft/ Disintegrated rock
152(d) Hard Rock
153Supply, install, testing and commissioning of LT Panel BoardCPRI approved cubical with kyosk type made of 3.15 mm thick outdoor typewith IP 43 grade of protection CRCA sheet, powder coated, with support of 50mm x 50mm x 6mmangle iron bottom frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved aluminium bus bar of capacity 630 Amps-4 Nos,fixed on suitable insulator,provision and fixing of digital Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etcfixed on suitable PCC foundationscomplete testing and commissioning complete all as specified and directed and shall be consisting the following :- Incomer: MCCB thermal magnetic release range4 pole 630 amps, 36 KA breaking cap with extended rotary handle - 01 No, Basic digital multifunction meter - 01 No, Surface mounted LED (R,Y,B) indication lamp 16 mm dia on each phase suitable for 415V AC - 01 Set, Outgoing: MCCB thermal magnetic release 4 pole 400 amps 36 KA-01 No, MCCB thermal magnetic release 4 pole 200 amps 25 KA - 02 No, MCCB thermal magnetic release 4 pole 125 amps 25 KA - 02 No
154Supply and fixing wall mounted copperBusbar chamber 100 amps, 8 way suitable for 415v, AC fixed on existing pole/wall with clamps, nut and bolts and other connected items required at site complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy