Tender For Preventive Maintenance Of Boosters And Tubewells Centrifugal Pumps Submersible Pump Lt Panels And Allied Works In Sector A Under Ge Utility Ambala Cantt, ambala-Haryana

Military Engineer Services-MES has published Tender For Preventive Maintenance Of Boosters And Tubewells Centrifugal Pumps Submersible Pump Lt Panels And Allied Works In Sector A Under Ge Utility Ambala Cantt. Submission Date for this Tender is 04-05-2024. Electrical Panel Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43077741
Corrigendum : Tender For Preventive Maintenance Of Boosters And Tubewells Centrifugal Pumps Submersible Pump Lt Panels And Allied Works In Sector A Under Ge Utility Ambala Cantt
Open Tender
Indian
Haryana
ambala
04-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Preventive Maintenance Of Boosters And Tubewells Centrifugal Pumps Submersible Pump Lt Panels And Allied Works In Sector A Under Ge Utility Ambala Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
b35890eb-b9c8-499c-9fe1-da53086c5a31.html Tender Notice 0 KB
BOQ_726130.xls Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : Preventive Maintenance of Boosters and Tubewells, Centrifugal pumps ,Submersible Pump, LT panels and allied works in Sector "A" under GE (U) Ambala Cantt.
Sl. No. Item Description
1Material & Labour for taking down centrifugal induction motor of capacity 40/30 HP, 3 phase from foundation and transport to work shop for rewinding, taking out burnt winding wire and rewinding with copper wire of suitable gauge or as per existing gauge complete including all required insulation material and transport back to site after testing and commisioning complete all as specified and directed.. Note : a) The Motor testing will be done before installation on No load for any unbalance load and should be free from vibration and if found unsatisfactory no payment will be done to contractor for defected motor. b) Necessary thimbles, lugs, insulation tape, nut bolts and allitems required for installation of motor at site will be included in the rate quoted by the contractor. No extra payment will be done to contractor. b) After dismentling of induction motor repair ofPCC foundation workwill be executed during the winding work with replacement of base frame of angle iron of existing size of angle if found damaged or deformed. These items will be measured and paid separately under respective items.
2All as per srl item No 1 here in before but of capacity upto 25 HPcomplete all as specified and directed.
3Material & Labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level, filled around with layer of char coal dust and salt and connected to GI earth strip 32 x 6 mm by means of bolt, nut and check nuts and washers of galvanzied iron or steel and other end of the earth strip, connected to test point/equipment/panel and protected by galvanized iron pipe light grade 50mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1:3:6 in chambers, RCC 1:2:4 in pit cover reinforced with 6mm dia deformed bars @ 15cm centre to centre both way including necessary excavation & earth work as directed complete all as shown in electric plate No. 5 of SSR Pt-I. PCC chambers shall be constructed at leasts 1.5 mtr away from the earth electrode and pipe for watering complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with standgrouted in PCC. (iii) On testing after completion if the desired earth resistanceis more than 2?the earthing will be redone at no extra cost
4Supply and fix in replacement MCCB 3P, 415V , 16 KA breaking capacity, 63 Amp adjustable thermal and adjustable magnetic setting including suitable thimble nut bolt and washerscomplete all as specified and directed
5Supply and fix in replacement MCCB 3P, 415V , 16 KA breaking capacity, 125 Amp adjustable thermal and adjustable magnetic setting including suitable thimble nut bolt and washers complete all as specified and directed.
6Material & Labour in replacement of the unserviceable timer switch suitable for 240/415 Volts3-30 Sec, 50 Hzcomplete all as specified and directed.
7Material and labour in replacement of worn out / defective thermal overload relay with range 45-75 Amps415 V, 50 Hz, complete all as specified and directed.
8Supply and fix in replacement MCCB 4P, 415V , 36 KA breaking capacity, 250 Amp adjustable thermal and adjustable magnetic setting including suitable thimble nut bolt and washerscomplete all as specified and directed
9Material & Labour in replacement of the unserviceable contactor 3 pole of AC3 ratingupto 40 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screwscomplete all as specified and directed
10Material & Labour in replacement of the unserviceable contactor 3 pole of AC3 rating upto 85 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screws complete all as specified and directed
11Supply & Fixing in replacement on load change over 3 phseand neutral of 200 A complete all as specified and directed.
12Material & Labour in replacement of base frame of centifugal pump set made out of angle iron of size ISA 5050, 50x50x6mm or medium channels of size MC-100including cutting, drilling hole or welding work required to make desired shape or existing size duly paint with one coat of primer red oxide and two coat of enamel paintcomplete all as specified and directed. Note: The base frame should be grouted complete in PCC foundation and should be taken necessary bearing strength before the installation of induction motor.
13Material & Labour for attending any type pump/motor/LT panels/Starters complaint at Boosters and rectify the same, rates are also included for replacement of suitable thimbles any type and any size with nut-bolts, Al/Cu busbar of existing/suitable size, cable jointing with tap and multistranded copper cable piece upto size 35 sqmm upto 2mtr length , gland packing, greasing in pumps/valves with all connected itemscomplete all as specified and directed. Note: Complaint should be rectify within 06 Hrs otherwise a penalty of Rs 250 per day will be imposed.
14Material & Labour in replacement of the unserviceable contactor 3 pole of AC3 rating upto 70 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screws complete all as specified and directed
15Taking out oldUNSV CI pipe 200mm dia without major demolition of floor/drain/wallincluding all fittings, Sluice valves etc, Supply and laying of 200mm bore MS/DI Pressure Pipes suitable with Flanged ends in replacement ofUNSV pipe and reinstallaing all serviceable valves, fittings safely without any damage to installation making the pipe leak proof completely including cutting, welding, threading, bending etc with nut bolts washer/gasket/clamps etccomplete all as specified and directed. Note : (i) Pipe and fittings shall be measured and paid saperately. (ii) contractor shall made the damaged site/drain complete good as per existing situation with PCC, plaster etc as if reqd to entire satisfaction of engr-in-charge. and NO additional cost will be paid for the same.
16Supply and Fix in replacement on load change over 3 phse and neutral of 400 Acomplete all as specified and directed.
17Supply and Fix inreplacement of automatic star delta starter with single phase preventer,RYB indicator,voltmeter and ammeter 415 volt 3 phase suitable for 50 HP motor complete all as specified and directed.
18Supply and Fix inreplacement of DOL Starter of capacity upto 7.5 HP motor 415 volt 3 phase complete all as specified and directed.
19Supply and fix in replacement MCCB 4P, 415V , 36 KA breaking capacity, 160 Amp adjustable thermal and adjustable magnetic setting including suitable thimble nut bolt and washers complete all as specified and directed.
20Supply and fixing retro reflector board visible from both side (front and back) of size 4"x3" with high quality retro reflector tape green base high intensity prismatic sheeting (HIP) grade white retro tape cutting good quality with 3mm thick ACP sheet base including 40mm x 40mm square size MS pipe legs and all around the board appx 18 feet incl welding the MS flat plate of size 25mm x 3mm across the board appx 10 feet including grouting the sign board in PCC 1:2:4 including taking down existingcomplete all as specified and directed. Note: Details/description of printing words will be provided by department.
21Supply and fixing high quality ACP sheet board at installations of size 5 feet x 3 feet minimum with router cutting letter blue base of sheets and white colour acrylic letter with complete fitting of minimim 2 Nos LED lights of 20W of 4 feet including wiring from existing DB board and taking down existing complete all as specified and directed. Note: Details/description of printing words will be provided by department.
22Supply and fixing high quality ACP sheet board of size appx 20 feet x 3 feet(straight or arc shape) with router cutting letter blue base of sheets and white colour acrylic letter with complete fitting of minimim 3 Nos LED lights of 20W of 4 feet including wiring from existing DB board and taking down existing complete all as specified and directed. Note: Details/description of printing words will be provided by department.
23Supplying and laying in replacement synthetic Rubber insulated mats 25 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.complete all as specified and directed
24Supply & Fix in replacement on load change over 3 phseand neutral of 250 Acomplete all as specified and directed.
25Supply and fix gun metal gate valve of 50 mm bore and taking down existing complete all as specified and directed.
26Supply and fix gun metal gate valve brass of 25 mm bore and taking down existing complete all as specified and directed.
27Supply and fix gun metal gate valve of 40 mm bore and taking down existing complete all as specified and directed.
28Supply and fix in replacement MCCB 4P, 415V , 36 KA breaking capacity, 200 Amp adjustable thermal and adjustable magnetic setting including suitable thimble nut bolt and washers complete all as specified and directed.
29Material & Labour for rubber moulded machine pressed precast concrete interlocking paver with gray cement confirming to IS - 15658-2000 of 60 mm thickness, M-35 grade as in path, hard standing etc laid over 25 mm compacted sand cushioning,at any installation as per requirement including demolition of existingcomplete all as specified and directed.
30Supply & Fixing in replacement of Exhaust fan steel body AC sibgle phase 300mm sweep with blades, frame andlouvers complete including making a hole for fixing the exhaust fancomplete all as specified and directed.
31Supply and Fixing Rotational moulded polyethylene water storage tanks 500L capacity (cylindrical vertical with closed top) hoisted and fixed in position including disconnecing and taking down existing tankcomplete all as specified and directed
32Supply & Fixing in replacement Chlorine cylinder safety kit for 100 kg cylinder consisting of valve leak arrestor, surface leak arrestor, hood with gasket & vent valve, cylinder valve stem key, chain with suitable operating and tightening tools and other safely items etc. complete all as specified and upto entire satisfaction of engr-in-charge.
33Supply and fix in replacement MCCB 3P, 415V , 16 KA breaking capacity, 100 Amp adjustable thermal and adjustable magnetic setting including suitable thimble nut bolt and washers complete all as specified and directed.
34Takingout pump set along with column pipe flanged 100 mm bore with 2 nos submersible cable from bore hole of tube well with the help of chain pulley block or tripod located in different location by dismantling nut bolts and rubber gaskets and lowering down the same by refixing nuts, bolts and rubber gaskets complete all as specified and directed..
35Shifting repairable motor pump set to workshop ,taking out burnt winding wire from submersible motorof capacity 50/62 HP 3 phase ,rewinding with suitable size of PVC coated copper winding wire including replacement of burnt bushes complete all includinginsulation material and transportation back to site , testing and commissiong complete all as specified and directed. : Note: (i). The any electric fault occur during the running of the motor will be detected by the contractor rectification of the fault and rate are deemed to be included in the item. (ii). The motor burnt due to improsar cable joint of submersible cable will be beared by the contractor. (iii). The motor burnt due to earth fault due to poor insulated winding will be beared by the contractor. (iv). The cost of 2nd time burnt of the motor due to phase loss, cable fault, or any reason as mention in Para 2 (i) to 2 (iii) will be beared by the contractor.
36All as per srl itemNo. 35.00 above but of capacity 40 HPcomplete all as specified and directed
37Material & Labour in replacement of bearing bush for submersible motor upto 62 HP complete all as specified and directed.
38Material & Labour in replacement of sleeve for rotor for submersible motor upto 62 HP complete all as specified and directed.,
39Material & Labour in replacement of sealing kit for submersible motor upto 62 HP complete all as specified and directed..
40Material & Labour in replacement of thrust bearing pad for submersible pump set upto 62 HP complete all as specified and directed..
41Material & Labour in replacement of thrust platefor submersible motor upto 62 HP complete all as specified and directed..
42Material & Labour in replacement of motor / pump couplingfor submersible motor upto 62 HP complete all as specified and directed..
43Material & Labour in replacement of water drain plugfor submersible pump set of capacity 5 HP to 62 HPcomplete all as specified and directed..
44Material & Labour in replacement of sand guard for submersible motor upto 62 HP complete all as specified and directed..
45Material & Labour in replacement of upper bearing housing submersible motor upto 62 HP complete all as specified and directed.,
46Material & Labour in replacement of lower bearing housing submersible pump set upto 62 HP complete all as specified and directed.,
47Material & Labour in replacement of adopter piece submersible pump set upto 62 HP complete all as specified and directed.,
48Material & Labour in replacement of upper flange with stud for submersible pump set upto 62 HP complete all as specified and directed.,
49Material & Labour in replacement of lower flange with stud for submersible pump set upto 62 HP complete all as specified and directed.,
50Material & Labour in replacement of stage bowl CI for submersible pump set upto 62 HP complete all as specified and directed..
51Material & Labour in replacement of impellorfor submersible pump setof capacity upto 62 HPcomplete all as specified and directed.
52Material & Labour in replacement of neck ring gun metel for submersible pump set upto 62 HP complete all as specified and directed.
53Material & Labour in replacement of distance sleeve stainless steel for submersible pump set upto 62 HP complete all as specified and directed..
54Material & Labour in replacement of suction case for submersible pump set upto 62 HP complete all as specified and directed..
55Material & Labour in replacement of pump shaft for submersible pump set upto 62 HP complete all as specified and directed..
56Material & Labour in replacement of bowl stud with nut for submersible pump set upto 62 HP complete all as specified and directed..
57Material & Labour in replacement of bowl bush for submersible pump set of capacity upto 62 HP complete all as specified and directed..
58Material & Labour in replacement of MS Bolts & Nut 5/8" x 2"for column pipe of submersible pumpcomplete all as specified and directed
59Material & Labour in replacement of rubber gasket for 100 mm bore pipecomplete all as specified and directed
60Decoupling of centrifugal pumpfrom electric motor of cap 25/30 HP, dismantling from the foundation and shifting to local workshop approved by Accpeting Officer for opening the pumps for checking and rectification of defects by welding/threading/cutting/replacing defective parts which shall be measured and paid separately as supply only herein after including transporting back and refixing and testing complete all as specified and directed.
61Supply only upper half & Lower half casing with axially split volute design with suction and discharge flanged of existing size of horizontal split casing type centrifugal pump including welding/threading/cutting wherever if required and its studs, nut, bolts, washers, cylindrical pin and gasket etc complete all as specified and directed.
62Supply only CI impeller with bush bedcomplete all as specified and directed
63Supply only Pump Shaftcomplete all as specified and directed
64Supply only Wear Ringcomplete all as specified and directed
65Supply only but Shaft Sleeve DE/NDE and its O Ring complete all as specified and directed
66Supply only Gland packing with its studs and Hexa nutscomplete all as specified and directed
67Supply only Lentern Rung, Oil seal & O Ring complete all as specified and directed
68Supply and fix in replacement Cast iron sluice valve 300 mm dia, flanged ends, stem (spindle) of SS (forged)and check nut of gun Metal, PN rating 1.6, working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valve complete all as specified and directed.
69Supply and fix in replacement Cast iron sluice valve 150 mm dia, flanged ends, stem (spindle) of SS (forged)and check nut of gun Metal, PN rating 1.6, working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valvecomplete all as specified and directed
70All as per srl item No 69 here in before but of size 100 mm diacomplete all as specified and directed
71All as per srl item No 69 here in before but of size 200 mm diacomplete all as specified and directed
72Material & Labour fordismantling, opening, repairing &rewinding of dewatering pump with motor of capacity upto 2HP with super enamelled copper winding wire as per existing gauge, cotton tape, leatherised strips, varnish, complete including testing after installation at site complete all as specified and directed
73Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and making electric connection with PVC insulated copper conductor (multistrand) cable of 1.5 sq mm size including taking down existing complete all as specified and directed
74Material & Labour for RCC slab cover of size min 1.mx0.5m having TMT bars of size minimum 10mm dia with gap n.exc 75mm between two rows for valve pits in single piece or double piece as per suitable size of pit with handles to lift, atleast 100 mm thick having provision of valve key slotcomplete all as specified and directed
75Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 100 to 200mm bore sizecomplete all as specified and directed
76Taking out sluice valves refacing, regrinding and refixing including replacement ofspindle, check nut complete assembly and make serviceable of size 100 to 350mm bore size complete all as specified and directed.
77Supply and fix in replacementNon return valve with flanged ends with nut-bolts and rubber gasket suitable for pipe of size 150 mm complete all as specified and directed.
78All as per srl item No 77 here in before but of size 100 mm diacomplete all as specified and directed
79All as per srl item No 77 here in before but of size 80 mm diacomplete all as specified and directed
80Supply and fix in replacement Foot valve with flanged ends with nut-bolts and rubber gasket suitable for pipe of size 100 mmcomplete all as specified and directed
81Material & Labour for providing PVC flat copper conductor cable in replacement of size 6 Sqmm 3 core multi stranded cable connected with pumpsand required copper thimbles and nut bolts to panelscomplete all as specified and directed.
82All as per srl item No 81 here in before but of size 10 sqmm 3 core multi stranded cable complete all as specified and directed
83All as per srl item No 81 here in before but of size 16 sqmm 3 core multi stranded cable complete all as specified and directed
84All as per srl item No 81 here in before but of size 25 sqmm 3 core multi stranded cable complete all as specified and directed
85Material and labour for column pipe made out from 100 mm bore CI heavy class ISI marked of appox 3 meter length having both ends flanged (suitable for submersible cable ) and drill complete all as specified and directed.
86Material and labour for preparing old steel surface and painting with spray gun one coat of synthetic enamel paintto submersible/Booster pump set & pipe lines, Panel with silver color complete all as specified and directed..
87Demolition of Cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) or under the over head tank/road cutting etc complete all as specified and directed. Note : The debris after demolition of PCC should be removed complete and spread to area where directed by Engr-in-Charge.
88Material and labour for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surfacecomplete all as specified and directed
89Material and labour for PCC 1:3:6type C2 using 40 mm graded aggregate for foundation of suitable size or/as in path,paving/under water filling point etc finished even and smooth using extra cement completeas per site requirement complete all as specified and directed.
90Material and labour for Mild steel framed works such as grills, gratings etc with ends of bars, shouldered and/or rivetted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame works of water tank and similar work confirming to Fe.290.Gde-E-165 including nuts, bolts, washers, welding, binding, cold or hot, drilling holes for bolts, in any shape or size inclusive of one primer coat, one under coatand one finishing coat ofpaintcomplete all as specified and directed
91Dismantlling & openingbooster pump for repairing, making the same functional including installation & testing,complete all as specified and directed Note :(a) Spare parts required shall be measured and paid separately as supply only under the respective items of Schedule A BoQ. (b) Make of spare parts shall be same as of booster pump.
92Supply only shaft bush of booster pump suitable upto 5 HP complete all as specified and directed
93Supply only ball bearing suitable for pump upto 5 HP complete all as specified and directed
94Supply only bronze impeller. complete all as specified and directed
95Supply only stainless steel shaft keys complete all as specified and directed
96LT control panel Outdoor type, 3 phase 4 wire 415 V, 50 Hz of size min 1.8 mtrx1.5 mtr 45 cm deep made out of CRCA sheet of size 2 mm thick. The panel has compartement type for fixing the accessoried and the panel has front openable . The panel will be IP 54 protection and lockable with chromium plated 19 mm dia fancy locks having lovers and air vent gasket for natural flow of air.The panel should have aluminium bus bar 1.5 times the rated capacity of incoming MCCB and colour coded on the bus bar and shrinkable sleeve on the bus bar to withstand high resistance. The panel have interconnection of main bus bar and outgoinh bus bar. The cubical shell have a bottom channel of size 75x40 mm duly coated with zinc metal fixed in pcc 1:4:8 D2 using 40 mm graded crushed stone aggregate including taking down of old UNSV LT panel . The panel shall be powder coated. The panel comprising space for installing one star delta starter of suitablbe for size upto 50HP submersible pumpset.
97INCOMING: (i) 4 pole MCCB 160 Amp, 36 KA rupturing capacity - 1 No. (ii) Aluminium bus bar 3 phase 4 strip suitable for 300 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves.(iii) 200 amps manual changeover. (iv) Phase indicating lights & control fuses -1 Set. (v) Voltmeter (0-500V) range with selector switch - 1 Set.
98OUTGOING: (i) 02 Nos x 4 pole, MCCB125 Amps, 36 KA breaking capacity (01 spare) for 01 saperate automatic star delta starter provided with suitable size contactor, overload and underload relay , single phase preventor etc suitable for upto 50 HP submersible pump set complete- 01 Nos (ii) RYBindication lamp -01 set. (iii)Voltmeter of size 4"x4" with inbuilt selector switch 0-500 Volts, 3 phase accuracy class 0.5 CL, 50 Hz flush mounted square pattern -01 Nos. (iv) Ammeterof size 4"x4" with inbuilt selector switch 0-200 Amp accuracy class 0.5 CLsuitable for 3 Phase, LT, 50 Hz system flush mounted square pattern and set of three CTsof suitable rating with all the outgoing feeder-01 Nos.
99Material and labour brick work with sub class "B" bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 including demolition of existing brick work complete all as specified and directed.
100Material and labour 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick walls or concrete external surfacesfinished even & smooth without using extra cement complete all as specified and directed.
101Maintenance and repair to water supply services of leakage blockagefor GI pipe line of 15mm to 80mm dia including dewatering and necessary excavation returning / filling or cutting, chasing and making of disturbed surfaces as per existing surface and replacing worn out GI pipe max upto 2 mtrs long including cutting threading and replacement of requisite fittings as socket, union, tees, long screwes nipple, hexa nipple , reducer etccomplete all as specified and directed.
102Maintenance and repair to leakage/blockage of water supply CI/DI pipe line of 80 mm to 300 dia size including necessary excavation required for taking out burning out lead joint or damaged rubber ring/hole from position and making the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or Tyton joint/D-joint or necessary fitting required as per site properlyand making the pipe line leak proof completly to the entire satisfaction of Engineer-in-Charge.
103Excavation in trenches not exc 1.50 metre wide not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting outcomplete all as specified and directed
104Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cmcomplete all as specified and directed
105Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting pointcomplete all as specified and directed
106Supply and laying Centrifugally Cast (Spun) Ductile Iron Pressure Pipes of 200 mm bore size with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining as per IS: 455:1989 and external Metallic Zinc Coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329 inclding taking down existing CI/DI pipe complete all as specified and directed.
107All as per Item Sl No. 100 here in before but of size 150 mm borecomplete all as specified and directed
108All as per Item Sl No. 100 here in before but of size 100 mm bore complete all as specified and directed
109Supplyand fixing ductile iron fitting for spigot and socket /fanged pipe such as bends (any type radius and angle) tapers any type ( straight, bends, increasing, decreasingor double socket etc) Tee pieces single branch, "Y" junction, double branch , cross collers , caps and plugs upto 150 mm borecomplete all as specified and directed.
110Material and labour in replacement for LT control panel indoor type 3 phase 4 wire 415 V, 50 Hz of min size 1.8 mtrx2.4 mtr 45 cm deep made out of CRCA sheet of size 2 mm thick. The panel has compartement type for fixing the accessoried and the panel has front openable . The panel will be IP 54 protection and lockable with chromium plated 19 mm dia fancy locks having lovers and air vent gasket for natural flow of air.The panel should have aluminium bus bar 1.5 times the rated capacity of incoming MCCB and colour coded on the bus bar and shrinkable sleeve on the bus bar to withstand high resistance. The panel have interconnection of main bus bar and outgoinh bus bar. The cubical shell have a bottom channel of size 75x40 mm duly coated with zinc metal. The panel shall be powder coated. The panel comprising space for installing three Nos star delta starter of suitablbe size for upto 30HP pumpset
111INCOMING: (i) 4 pole MCCB 250 Amp, 36 KA rupturing capacity - 1 No. (ii) Aluminium bus bar 3 phase 4 strip suitable for 400 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves.(iii) 250 amps manual changeover. (iv) Phase indicating lights & control fuses -1 Set. (v) Voltmeter (0-500V) range with selector switch - 1 Set.
112OUTGOING: (i) 04 Nos x 4 pole, MCCB100 Amps,36 KA breaking capacity(01 spare) with 03 nos x automatic star delta starter provided with suitable size contactor, saperate overload & underload relay , saperate single phase preventor etc suitable for 30 HP centrifugal pump set complete- (ii) RYBindication lamp -03 set. (iii)Voltmeter digital type of size 4"x4" with inbuilt selector switch 0-500 Volts, 3 phase accuracy class 0.5 CL, 50 Hz flush mounted square pattern -01 Nos. (iv) Ammeter digital type of size 4"x4" with inbuilt selector switch 0-200 Amp accuracy class 0.5 CLsuitable for 3 Phase, LT, 50 Hz system flush mounted square pattern and set of three CTsof suitable rating with all the outgoing feeder-03 Nos.
113Material and Labour for Cutting/removing of bushes/small trees/vegetationgrowth upto a distance of appx 50 mtr around the sump at 288 Med regt, Old OHT-8,and other OHTs, Tubeswells/Boosters and installations area not exc 30cms deep incl drains all around the installation incl rough surface leveling/cutting, and burning at a distance of 50mtr (minimum) in the presence of Engr-in-charge including
114Material and Labour for sprinkling the round up chemicals for drying/killing the bushes,shrubs etc.complete all as specified and directed
115Supply, installation and commissioning in replacement of Busbar panel outdoor type with locking arrangement MS sheet covering 3.15 mm thick pedestal mounted vermin and weatherproof including four legs of 60 cm long of angle iron 40x40x6mm, front openable door having canopy for protection all surfaces painted with powder coated painting, embedding and including 300 Amp rated aluminium bus bars6 Nos in vertical position duly drilled for making connection with nut bolts of suitable size with colour code tape complete with PCC 1:3:6type C1 using 20 mm graded aggregate forfoundation for legs and dry 63mm aggregate of 75mm thickness around the panelupto 6 sqft after make good electrical connectioncomplete all as specified and directed Note: The rate are included with thimbles lugs, nut bolts,PCC foundation and aggregate.
116Material and labourfor point wiring with two run of single core 1.5 sqmm using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch controlled by one switchwith PVC insulated, unsheathed FRLSH multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked or casing caping as per site requirement, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket, belland regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLSH cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets & regulators will be measured and paid for separetely). MAKE OF CABLE : Bonton/ Nicco/ Plaza/ Paragon MAKE OF CONDUIT: Prince/ Supreme/ Diplast Note:- (i) Wiring shall be done by using colour code.(ii)Earth wire shall be of green colour.
117(a) One light / Fan / Bell Point controlled by one switch 5 Amp one way using cable 1.5 Sq mm for phase and neutral and 1.5 sq mm earthing and connected to common earth dollycomplete all as specified and directed
118(b)One socket outlet,5 Amp, independent, with 1.5 sqmm (nominal area) cable for phase & neutral and 1.5 sqmm (nominal area) cable as earth continuity FRLS copper conductor complete all as specified and directed
119(c)One socket outlet 15 Amps on Independent board, butusing cable 2.5 Sq mm for Phase & neutral and 1.5 Sqmm for earthing and connected to common earth dollycomplete all as specified and directed.
120Supply and Fix switch modular type 5 Amp one way module type complete all as specified and directed.
121Supply and Fix switch modular type 15 Amp one way module type complete all as specified and directed.
122Supply and Fix socket outlet 2 in 1, 3 Pin, 6 Amp modular type complete all as specified and directed
123Supply and Fix socket outlet, 2 in 1, 3 Pin16 Amp modular type complete all as specified and directed
124Material and labour & fixing in replacement for LT control panel outdoor type 3 phase 4 wire 415 V, 50 Hz of size 1.2 mtrx1.5 mtr 45 cm deep made out of CRCA sheet of size 2 mm thick. The panel has compartement type for fixing the accessoried and the panel has front openable . The panel will be IP 54 protection and lockable with chromium plated 19 mm dia fancy locks having lovers and air vent gasket for natural flow of air.The panel should have aluminium bus bar 1.5 times the rated capacity of incoming MCCB and colour coded on the bus bar and shrinkable sleeve on the bus bar to withstand high resistance. The panel have interconnection of main bus bar and outgoinh bus bar. The cubical shell have a bottom channel of size 75x40 mm duly coated with zinc metal fixed in pcc 1:4:8 D2 using 40 mm graded crushed stone aggregate including demolition of old UNSV LT panel . The panel shall be powder coated. The panel comprising space for installing one star delta starter of suitablbe for size upto 50HP submersible pumpset.
125INCOMING: (i) 4 pole MCCB 160 Amp, 36 KA rupturing capacity - 1 No. (ii) Aluminium bus bar 3 phase 4 strip suitable for 300 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves. (iii) Phase indicating lights & control fuses -1 Set. (iv) Voltmeter (0-500V) range with selector switch - 1 Set. (v) Amp meter (0-200A) range with C.T.S. of suitable size and selector switch - 1 Set
126OUTGOING: (i) 4 pole, MCCB125 Amps,36 KA breaking capacity automatic star delta starter provided with suitable size contactor, overload and underload relay , single phase preventor etc suitable for upto 50 HP submersible pump set complete- 01 Nos (ii) RYBindication lamp -01 set. (iii)Voltmeter of size 4"x4" with inbuilt selector switch 0-500 Volts, 3 phase accuracy class 0.5 CL, 50 Hz flush mounted square pattern -01 Nos. (iv) Ammeter of size 4"x4" with inbuilt selector switch 0-200 Amp accuracy class 0.5 CLsuitable for 3 Phase, LT, 50 Hz system flush mounted square pattern and set of three CTsof suitable rating with all the outgoing feeder-01 Nos.
127Material and labour in replacement of unsv analog ammeter withnew 3Ph LED Ammeter of acurracy class 0.5 of rating 0-200 amps flush mounting Inbuilt selector switch for 3 phase meters with all necessary new CTs of suitable ratio and wiring complete for 415V, 50Hz 3 phase with testingcomplete all as specified and directed
128Material and labour in replacement of unsv analog Voltmeter withnew 3Ph LED Voltmeter of acurracy class 0.5 of rating 0-500 amps flush mounting Inbuilt selector switch for 3 phase meters with all necessary new PTs of suitable ratio and wiring complete for 415V, 50Hz 3 phase with testingcomplete all as specified and directed.
129Note:-Amount of credit ofRs. 231960.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in PDF form which will be deducted offline while acceptance of tender.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail