Tender For Special Repair For Replacement Of Ber Summer Appliances Centralized Ac Plant At 1 Wec Under Ge(U) Pm Delhi Cantt10., delhi-Delhi

Military Engineer Services-MES has published Tender For Special Repair For Replacement Of Ber Summer Appliances Centralized Ac Plant At 1 Wec Under Ge(U) Pm Delhi Cantt10.. Submission Date for this Tender is 20-04-2024. AMC of Air Condition Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43077717
Tender For Special Repair For Replacement Of Ber Summer Appliances Centralized Ac Plant At 1 Wec Under Ge(U) Pm Delhi Cantt10.
Open Tender
Indian
Delhi
delhi
20-04-2024

Tender Details

Tender For Special Repair For Replacement Of Ber Summer Appliances Centralized Ac Plant At 1 Wec Under Ge(U) Pm Delhi Cantt10.

Key Value

Document Fees
INR 500 /-
EMD
INR 77160.0 /-
Tender Value
INR 38.58 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR FOR REPLACEMENT OF BER SUMMER APPLIANCES & CENTRALISED AC PLANT AT 1 WEC UNDER GE(U) P&M DELHI CANTT-10.
Sl. No. Item Description
1Supply, Installation, testing and commissioning of VRF type AC units, Outdoor type, capacity 12 HP, air cooled, 100% inverter compressor based VRF system using R410 refrigerant Gas, including first fill of refrigerant. The system shall be suitable for cooling and heating both purposes and shall work on 3-phase , 415V, 50Hz AC powersupply. Twin scroll compressors with accumulator, air cooled condensersmade with corrosion proofHydrophilic blue fins and its fan with motors, microprocessor controls, control panel along withinternal control and power wiring, internal interconnected refrigerant pipes, charging ports with prechargednon CFC gas of Eco Friendly Refrigerant ( R 410A) as per OEM recommendations. Theunit shall be heating-cooling both type and no duration up to 43° Cand non stop cooling up to 56 °C.Quoted rates complete all as specified and directed. (Make :- Bluestar/ Daikin/ Hitachi) Note :- 1. The bidder is required to submitcertificate from the OEM duly signed by GM Level Officer and stamped for back to back support (along with Technical bid, failing in submission of Certificate will led to rejection of the Bid). 2. All VRF Installation work to be execute by OEM or OEM Authorised Vendor Only. 3.PCC and block Mesonry work for grouting of outdoor unit shall be included in quoated rates complete all as specified and directed.
2Supply, Installation, testing and commissioning of VRF type AC units, Outdoor type, capacity 22 HP, air cooled, 100% inverter compressor based VRF system using R410 refrigerant Gas, including first fill of refrigerant. The system shall be suitable for cooling and heating both purposes and shall work on 3-phase , 415V, 50Hz AC powersupply. Twin scroll compressors with accumulator, air cooled condensersmade with corrosion proofHydrophilic blue fins and its fan with motors, microprocessor controls, control panel along withinternal control and power wiring, internal interconnected refrigerant pipes, charging ports with prechargednon CFC gas of Eco Friendly Refrigerant ( R 410A) as per OEM recommendations. Theunit shall be heating-cooling both type and no duration up to 43° Cand non stop cooling up to 56 °C.Quoted rates complete all as specified and directed. (Make :- Bluestar/ Daikin/ Hitachi) Note :- 1. The bidder is required to submit certificate from the OEM duly signed by GM Level Officer and stamped for back to back support (along with Technical bid, failing in submission of Certificate will led to rejection of the Bid). 2. All VRF Installation work to be execute by OEM or OEM Authorised Vendor Only. 3.PCC and block Mesonry work for grouting of outdoor unit shall be included in quoated rates complete all as specified and directed.
3Supply, Installation, testing and commissioning of VRF type AC units, Outdoor type, capacity 28 HP, air cooled, 100% inverter compressor based VRF system using R410 refrigerant Gas, including first fill of refrigerant. The system shall be suitable for cooling and heating both purposes and shall work on 3-phase , 415V, 50Hz AC powersupply. Twin scroll compressors with accumulator, air cooled condensersmade with corrosion proofHydrophilic blue fins and its fan with motors, microprocessor controls, control panel along withinternal control and power wiring, internal interconnected refrigerant pipes, charging ports with prechargednon CFC gas of Eco Friendly Refrigerant ( R 410A) as per OEM recommendations. Theunit shall be heating-cooling both type and no duration up to 43° Cand non stop cooling up to 56 °C.Quoted rates complete all as specified and directed. (Make :- Bluestar/ Daikin/ Hitachi) Note :- 1. The bidder is required to submitcertificate from the OEM duly signed by GM Level Officer and stamped for back to back support (along with Technical bid, failing in submission of Certificate will led to rejection of the Bid). 2. All VRF Installation work to be execute by OEM or OEM Authorised Vendor Only. 3.PCC and block Mesonry work for grouting of outdoor unit shall be included in quoated rates complete all as specified and directed.
4Supply installation,testing and commissioning ofHiwall Units with evaporator coil,fan and Fan motor ,cord less remote control , and necessaryaccessories etc suitable for operation on 230 V + 10% 50 Hz single phase AC supply complete as required .The units shall be of following capacities :-
5Capacity2.0TR (Make :- Bluestar/ Daikin/ Hitachi)
6Capacity 2.5TR (Make :- Bluestar/ Daikin/ Hitachi)
7Capacity 2.8TR (Make :- Bluestar/ Daikin/ Hitachi)
8Supply of Cordless Remote Control
9Supply and fixing refrigerant Y-Joint for Combining Outdoor and Indoor Units required for distribution of refrigerant in copper piping as per final approved drawing which will be submitted bycontractor from OEM.
10Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of following sizes including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications.All Piping intall on cable trays with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed. Make of Copper pipe :- Diamond/ Star/ Mandev Make of insulation :- KAIFLEX/ KFLEX/ VIDOFLEX/ PARAMOUNT
119.5 mm with 13 mmthick insulation
1212.7 mm with 13 mmthick insulation
1315.9 mm with 13 mmthick insulation
1419.1 mm with 13 mmthick insulation
1522.2 mm with 19 mmthick insulation
1628.6 mm with 19mm thick insulation
1734.9 mm with 19 mm thick insulation
18Supply and fixing Rigid PVC piping complete with fittings, supports and duly coveredwith 9 mm thick closed cell nitril rubber insulation complete all as specified and directed. (Make:- Prayag/ Supreme/ Prince/ Polytuff) Note :- Providing and fixing in position the following size of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category.
1925mm dia pipe (NB)
2032mm dia pipe (NB)
21Supply, fixing of MS Outdoor Stand as per OEM Recommendation
22Supply and fixing of 125mm deep AntivibrationFlexible Jointsmade out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units & AHU.
23Supply and charging Additional refrigerant gas ofR 410A complete all as specified and directed. (Make :- Mefron/ Floron/ Refron)
24Supply and installation, testing, commissioning Outdoor type feeder piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey completeall as specifed abd directed& Connisting of the followingequipments:- (i) MCCB, 4 pole , 25 KA , 160 Amps adjustable to thermal MagneticRelease-01 No ( Incomming) (ii) MCCB , 4 pole ,16 KA, 63 Amps -03 No (Out going)(III) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set (MAKE for MCCB :- L & T/Legrand / ABB / Havells) (v) Solid aluminium bus bar 400 Amp for 3 phase , 200 Amp for neutral (vi) PCC and block Masonry work for grouting of panel complete all as specified and directed. (Make of LTPanel :- Universal Switchgear/ Dvepl/ PSC/ GM& G/ ITE Gurgaon/ Neptune/ Hensel/ Indo Asain/ Standard/ Havells/ C&S/ Electric/ Bhandari/ Shalabh/ Adhunik Switchgear/ HPL/ Seepl/ ABB/ L&T/ Siemens)
25Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion includingprovision of 40 mm GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, Charcol, salt, funnel, wire mesh, GI strip Up to 7.5 mtrs length complete all as specified and directed.
26Material & Labour for Earth continuity conductorfixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip
27Material & Labour for control wiring with 4 coreX 16sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Traycomplete complete all as specified and directed . (Make of Cable :- Finolex/ Havells/ Polycab) Make of PVC Conduit :- KALINGA/ PLAZA/ KAMPLAST (Note :- Four run of wire with PVC conduit will be considered as one Length.)
28Material & Labour for control wiring with 4 coreX 06 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Traycomplete complete all as specified and directed . (Make of Cable :- Finolex/ Havells/ Polycab) Make of PVC Conduit :- KALINGA/ PLAZA/ KAMPLAST (Note :- Four run of wire with PVC conduit will be considered as one Length.)
29Material & Labour for control wiring with 3 coreX 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed (Make of Cable :- Finolex/ Havells/ Polycab) Make of PVC Conduit :- KALINGA/ PLAZA/ KAMPLAST (Note :- Two run of wire with PVC conduit will be considered as one Length.)
30Material & Labour for control wiring with 2 coreX 0.75 sqmm sqmm , Sheilded wire, twisted pair & Sheilded 2 Core Sheathed Wire, Sheilding use for Earthing Connection, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed, (Make of Cable :- Finolex/ Havells/ Polycab) Make of PVC Conduit :- KALINGA/ PLAZA/ KAMPLAST
31Supply, Laying, jointing and testing of electric cable XLPE 3.5 Core 50 sqmm insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed . (Make :- Finolex/ Havells/ Polycab)
32Supply and fixing in repair MCB SP, 240 Volts, 10 Amps with MCB Metal enclose complete all as specified and directed. (Make :- L & T/ Legrand / ABB / Havells)
33Supply, Fixing & fabricate of Frame work on which Hiwall unit is to be installed. Framework is ofMetal Rectangular Tube (25mm x 10mm) & 2.5mm Thick duly Paint on it with first Coat of Primer complete all as specified and directed.
34Supply, Installation, testing and commissioning of water cooler fully stainless steel body(Top lid ,front top/bottom, rear top/bottom, dip tray, side paneletc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of make prayag/of suitable sizes as per manufacturer"s design & specificationwith Non CFC Refrigerant (R-134a) ,energy efficient reciprocating compressor ofmake Emerson/Tecumseh , suitable for operation on single phase 230V, 50 Hz, AC supply,havingstorage capacity of 80 litersand nominal cooling capacity of 40 liters per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray ,Brass (CR plated) push type double faucet , motor and condenser standing base made by stainless steel of minimum thickness1.0mm, minimum thickness of copper tube of condenser not less than0.50mm, and minimum one year replacement warranty (Machine & Compressor) complete all as specified and directed. (Make :- Model No. SR 40/80 of Sidwal / Model No. SRA 4080G of USHA or equivalent model of BLUE STAR)
35Supply, Installation, testing and commissioning of BEE 4 star rated frost free refrigerator double door, electric driven (single phase, 230V, 50 Hz, AC supply) of capacity not less than 308 Ltrs capacity with non CFC refrigerantinverter based compressor complete all as specified and directed (Make :- Latest Model of LG/ SAMSUNG/ Whirlpool)
36Supply, installation testing and commissioning Desert Cooler powder coatedbody of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwithdistribution switch, 5 Amp piano switch and tank of depth 11 inch, electric driven (single phase), 230V, 50 Hz, AC,fittedwith submersible pump of suitable capacity, rotary switch (Step type Speed Regulator), three core flexible copper conductor wire with 5 Amp Plug Top,wood wool pad on three sides andthree speed Exhaust motor of copper wounded,450 mm sweep complete all as specified and directed . (Make of Pump & Motor :- Crompton Cat ref 500MMCKM-MARKI or equivalent ofKhaitan/ Indcool.)