Military Engineer Services-MES has published Tender For Repair To Joinery, Flooring, Plumbing, Chajja, Facia, Plastering Of Certain Md And Otm Accn And Essential Repair To Earthing Infrastructure And Lighting Protection And Repair/ Maint Of Summer Cooling Appliances At Af Stn Bkt. Submission Date for this Tender is 02-05-2024. Electrification Work Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Apr-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-04-2024 |
2 | 27-Apr-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-05-2024 |
Sl. No. | Item Description |
1 | Taking down shutters of any description n exc 1 sqm each complete all as specified and as directed |
2 | Taking down shutters of any description exc 1 sqm and not exc 2 sqm each complete all as specified and as directed |
3 | Taking down chowkats with shutter (without taking off shutter from the frame)exceeding 1.5 sqm & not exceeding 4 sqm each complete all as specified and directed |
4 | Ditto all as per item No 3 abovebut not exc 1.5 Sqm each complete all as specified and directed |
5 | S & F 35mm thick, 2nd class HW, plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed |
6 | S & FIInd Class HW 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed |
7 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube, suppling & fixing in opening as per specification & drawing given as per SSR Part-II section-8 on page 158 complete all as specified and directed |
8 | S&F Flush shutters, solid core 40mm thick construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed |
9 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail, on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and directed |
10 | S&F for 18mm thick PVC board of one side prelaminated or digital finished and other side plan white colour to make kitchen cabinet shutter/drawaer front shutters, cupboard shutters including alaround beading of suitable size complete with and including all fittings as per specifications complete all as specified and directed.Make : Sintex/sunwin/ M/S Kumar Arch Tech Ltd, M/S H2O soultion |
11 | S&F for 18mm thick PVC board both side plain white colour fixed with screws, solvent cement/adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets complete with and inculding all fittings as per specifications, complete all as specified and directedMake : Sintex/sunwin/ M/S Kumar Arch Tech Ltd/M/S H2O soultion |
12 | S&F steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded completeall as specified and as directed |
13 | Ditto all as per item No 12 above but without glazing bar complete all as specified and directed |
14 | S&F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed |
15 | S&F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290, Gde- E-165 complete all as specified and directed |
16 | S&F pressed steel frames for doors size 165x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike, plate, etc complete all as specified and directed |
17 | S&F pressed steel frames for doors size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike, plate, etc complete all as specified and directed |
18 | S&F butt hinges 100mm size stainless steel complete all as specified and directed |
19 | S&F butt hinges 75mm size stainless steel complete all as specified and directed |
20 | S&Fbutt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and as directed. |
21 | S & F200mm longaluminium anodised, barrel towerbolts of extruded sectionand fixed complete all as specified and as directed |
22 | S& F aluminium handles fabricated type anodised 150mm size complete all as specified and directed |
23 | S&F 50mm dia, cupboard knobs,polished, hard wood knobs fixed with screws or nut bolts compleete all as specified and directed |
24 | S&F hasp and staple size 125 mmsafety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and direccted |
25 | S & F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast pr extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed |
26 | S & Fin repair 300mm brass ordinary rat tail rod pattern springs including roller and roller plate fixed in iron frame complete all as specified and as directed |
27 | M&L preparation ofnew surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying twocoat of synthetic enamel paint,over one coatpink primer complete all as specified and as directed |
28 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed |
29 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixedwith stainless steel wire staples fixedcomplete all as specified and directed |
30 | S&F in repairstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixedwith stainless steel wire staples fixedcomplete all as specified and directed |
31 | Dismantling of floor hearth and wall tiling incl mortar bedding removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
32 | M&L for Non Skid ceramic colouredtiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.06 Sqm but n. exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 15mm thick screed bed in CM 1:6 complete all as specified and directed |
33 | M&L for glazed ceramic coloured/printed tiles (colour & shade as approved by GE) of size 300 x 450mmx 7-8mm thick in verticle surfaces as in skirting and dado set and jointing neat cement slurry, over& including 10mm thick rendering in cement mortar (1:4) and pointed, in white cement with pigment to match the colour of tiles complete all as specified and directed |
34 | Taking down cement plaster on brick walls etc including racking out joints, hacking for keys in scrubbing down and washing with water etc complete all as specified and directed |
35 | M&L for 15mm thcik rendering on fair faces of brick work in cement mortar 1:6 and finishedeven and smooth without using extra cement complete all as specified and directed |
36 | Supply only Integral water proofing compound complete all as specified and directed |
37 | M&L for 15mm thcik rendering on other than fairfaces of brick work in cement mortar 1:4 and finishedeven and smooth without using extra cement complete all as specified and directed |
38 | M&L preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed |
39 | Hacking out old broken glass up to 9.50 m height (any thickness size, quality or description) from steel frames, glazed with putty or fixed with beads complete all as specified and directed |
40 | S&F 3mm thick plain sheet glass ordinary quality and glazing with oil putty upto 9.50M height in steel shutter in square n.exc 0.50 Sqm in each pane or any steel frame including glazing clips, complete all as specified and directed |
41 | S&F 3mm thick frosted glass panes and glazing with oil putty & pins/spring pins complete in squares n.exc 0.50 sqm each panes complete all as specified and directed |
42 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials where directedcomplete all as specified or directed |
43 | M & L for 75mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate , as in sub base of floor complete |
44 | M&L for cement concrete 1:2:4 type B1 (20mm graded aggregate) 40mm thick as in flooring finished cement concrete surface even and smooth without using extra cement complete all as specified |
45 | M&L for cement concrete (1:3:6) type C-2using 40mm graded stone aggregate 75mm thickas in plinth protectionincluding necessary form work and finishing surface even and smooth w/o using extra cement including bitumen joints complete all as specified. |
46 | S&F in repair stainless steel curtain rod 20mm dia decorative type with fixing of brackets, steps, roller suitable size of knob complete all as specified and directed |
47 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated brackets guard and railing 60 cm long complete all as specified and directed |
48 | Material, labour (Technician & Helper) and T&P including testing eqptsfor carring outs comprehensive maintenance and testing of earthing any type as per existing procedure for lighting protection /eqpts/domestic etc in tech area & admin area by tightening of nut bolts arranging earth lead in allighnment mannerreplacing unservicable earthing lead ,funnel ,pit coverand PCC pits etc (which will be paid as supply only) and testing of earthing and recording result in register (as per procedure provided as directed ,If result found more than permissible limit reconditioning of earthing carried out by pouring water with salt /chemical as per direction and further testing the same earthing result and recording in register incl levelling refilling of earth settle down near pit. Note-(i) Necessary compound required for recharging shall be measured and paid separately under item No 2 here-in-after.. (ii) Pouring of salt/chemical/charcoal water in the earth pit is included in the rate quoted. |
49 | Supply only charcoal dust powder of superior quality complete all as specified and directed |
50 | Supply only common salt of superior quality complete all as specified and directed |
51 | Supply only carbon based low resistivity compound Bentonite powder solution(advanced erath filling compound) complete all as specified and directed |
52 | Supply and laying in reapir galvanised iron tubing, 40 mm bore,light grade protection of earth strip pipe with all fittings forfixed to pole/wall/ in ground including all fixing accessories including taking out old damaged protection pipecompleteall as specified and as directed. |
53 | Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25m long hex. head screw including taking out old damaged/ rusted test point terminal block with connecting with earthing strip complete all as specified and directed. |
54 | Supply and laying in reapir galvanised iron tubing,15 mm bore, light grade with all fittings forlaying of Earth wire or for watering pipe including all fixing accessories and taking out old pipe complete all as specified and directed |
55 | Supply and fixPGI funnel with wire mesh of size 15 mm all including taking out old damaged complete all as specified and directed |
56 | Material & labour for Chemical earthingcomplete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge ofearth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of brass brazing at all joints all as directed and connected to earth test pointincluding galvenizing isolation for equipments to put E-N voltage within limit all as specified and testing on completion with and including necessary excavation and earth work in any type of soil ,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to earth test point of galvanised Iron / steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate ,including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writing letters as specified ny EIC complete and PCC pit 1:3:6 type C1 using 20 mm bore grade stone aggregrate on PCC base 1:4:8 type using 40 mm agregrate of size 1500x1500x100 mm thick with precast RCCcover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as spcifed and directed. |
57 | M& L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-Iincluding and connecting to earthing testpoint block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC base 1:4:8 type using 40 mm agregrate of size 750x750x100 mm thick with precast RCCcover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as spcifed and directed. including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writing letters as specified ny EIC complete including testing on completion complete all as specified and directed. |
58 | Ditto all as per item No. 57 above here in before but connected to galvanised earth strip 32mm x 6 mm as earthing lead complete all as specified and directed. |
59 | Ditto all as per item No. 57 above here in before but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and directed. |
60 | M&L forboring underground of 100 mm dia upto 30 mtr depth below ground level in any kind of soil strata for insertion of pipe electrode 30 mtr length and coper strips etc. for bore earthing complete all as specified and directed ( 1 X 30 RM each) |
61 | M& L for loweringbore Galvanised iron tubing, 50mm bore, medium grade with all fittingsaccessories for protection of earth stripscomplete all as specified and directed.( 30 Rm X 01 Nos) |
62 | M&L forcopper strip 25x3 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points. |
63 | M&L for chemical earthing by drillinmg a hole of 100 mm dia and 4 mtr in depth in any kind soil and providng a 3.0 mtr long pure copper strip of size 32x6 mm duly encapsulated in a medium gradegalvenized steel of pipeof 88 mm OD and filling the hole with advance non toxic earth enhancing back fill compond qy not less than 30 kg and water till complete soaking of chemical water mixture and providing a cylindricaltype FRP earth pit chamnber of size 254mm dia at top , 330 mm dia at bottom and 260 mm height and 7.5 m long copper strip of sizxe 32 mm x6 mm as earth lead conductor duly protrcted with 65 mm bore medium grade GI pipe from terminal point to earth test point and duly connected with terminal point through breezing and to connect with earth test point with brass bolt nuts and washer of suitable size and fixed on wall by mounting the strip of frp /DMC bridge insulator and providng a test point a terminal block made of gun metal of phosphorus bronze of size 75 mmx75mmx25mm duly drilled and screwed and fixed on wall on insulators including 3 nos 8 mm dia 25 mm long hex haed brass scew complete with removing of excavated soil to a distance not excedding 50 meter and height n. exc. 1.5 m from the starting p[oint and testing on completion all as specified and directed. Note- 1. Addl lenght of conductor beyond 7.5 mtr if required at sirebshal be measured and doplaid sperately undr resperctive item 2.On testting afer completion of job if desie earth resisirance less thasn 1 ohm is not fpound ther earthing shalll be redone at noextra cost o to govt. |
64 | Dismantling and taking down worn out and / broken air termination rod and supply and fixing new air termination,single pointed aluminium rod 12mm dia and 300mm long connecting with existing lightening conductor system complete all as soecified and directed. |
65 | Ditto all as per item No. 62 above here in before but with copper rod |
66 | Taking out existing unsv broken/rusted earthing strip of copper,GI and alluminium strip of any size from the existing lighting protection system and to test points all as specified and directed. |
67 | M&L for copper strip 20 mm x 3 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points and up to lighting protection system. |
68 | M&L for Alluminium earting strip of size 25X3 mm including nesassary brazing and connecting existing earthing / lightening conductor system for roof conductors and down conductors above ground levelcomplete all as specified and directed. |
69 | M&L for galvanised iron strip 32mm x 6mm with saddles and fixing screws on porcelain insulators for earth continuty conductor up to test points complete all as specified. |
70 | M&L for GI earting wire of size 4mm dia galvanised iron or steel wire including nesassary brazing and connecting with existing earthing systemcomplete all as specified and directed. |
71 | M&L for laying of single run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 10 Sqmm 1100 volts gradeas earthcontinuity conductor drawn through in rigid non metallic PVC conduit of suitable size onroof/wall/ceiling includingmaking good the disturbed surfaces ofwall etc includingtaking out old unserviceable burnt/damaged wire from its existing position complete all as specified and directed (Note : Non metallic PVC conduit rate included in the rate quoted). |
72 | M& L for Earthing pit of PCC pit 1:3:6 type C1 using 20 mm bore grade stone aggregrate on PCC base 1:4:8 type using 40 mm agregrate of size 800x800x100 mm thick with precast RCCcover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle all incld demolitising old broken pits complete all as specified and directed |
73 | M&L for brazing/soldering to the copper earth strip of size 20x3.15 mm including dismantling from existing position ,equipments without disturbing the functional requirment of the eqipmentsand reconnecting completeall as specified and directed. |
74 | M & L for pit marker/indicator of size 300x200x3 mm with alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of rad oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writing letters, in different colors as per directive of VCAS 2016 of Airforce |
75 | M&L for painting of pit chamber and cover with syntetic enamelled paint as per code all as specifed and directed |
76 | M& L for servicing including comprehensive maintenance of split and window air conditioning of 1.5 to 3 ton capacity at site by skilled mechanic with associated staff with process cleaningevaporator / cooling coil ,condensor coil by using pressure pump ,clear water with copper friendly chemical solution for removing complete dust, checking function of all components, rectifying defect with replacement of defective parts (if found),charging of gas ,welding brazing etcall as specified and directed NOTE;- (i) Defective partsshall be measured and paid seperately as"Supply Only" under respective item of Sch "A" (ii) Complaints have to attend on day to day basis and regular visit of adequate mechanic during contract period to maintain above Nos appliances at the Stn in tech and as well as Adam area. (iii) Payment for each job shall be made once only during currency of contract irrespective of attending / replacing defective parts at any time that will be paid supply only under respective item if not paid earlier. (iv) complaint for non function of ACs have to attend on same day and normal defects have to rectify within 24 hours ,major defects have to rectified within 4 days otherwise recovery shall be made @ 500/ day of delay. (v) If required and repair is beyond at site taking out & refixing of AC / any repair shall be deemed to include in quoted rate. |
77 | Supply only the following Items to fixed under Item sr No. 1 mentioned here in before complete all as specified and directed Supply only Starting capacitor 80-100 mfd for window/Split type room air conditionercomplete all as specified and directed by Engineer-in-Charge |
78 | Ditto all as per item No. 77 above here in before but 4 mfd |
79 | Ditto all as per item No. 77 above here in before but 6 mfd |
80 | Supply only Running capacitor 10 mfd |
81 | Supply only running capacitor capacity 36+5/6 mfd |
82 | Supply only running capacitor capacity 45+5/6 mfd |
83 | Supply only running capacitor capacity 50/55+5/6 mfd |
84 | Supply only Starting relay for 1.5 Ton window type ACcomplete all as specified and directed Make :Renutrol/indfoss |
85 | Supply only Starting relay suitable for 1.5/2.0 TR split type AC all as per sammple |
86 | Supply only Refrigerant gas R-22 |
87 | Supply only Refrigerant gas R-410 a/134 a |
88 | Supply only Refrigerant gas R-32 |
89 | Supply only PVC braided flexible drain pipe 15 mm |
90 | Supply only Top Plug3 pin 220 Volt 5 Amp |
91 | Supply only Top Plug3 pin 220 Volt 15 Amp |
92 | Supply only Industrial protected socket3 pin 240 volt 20 Amp |
93 | Supply only Industrial protected plug top 3 pin 240 volt 20 Amp |
94 | Supply only Defrost timer for domestic refrigerator complete all as specified and directed |
95 | Ditto all as per item No. 94 above here in before but Bimetal relay |
96 | Ditto all as per item No. 94 above here in before but Defrost heater |
97 | Ditto all as per item No. 94 above here in before but over load proection for refrigerator /dispensor |
98 | Ditto all as per item No. 94 above here in before but PTC relay |
99 | Supply only Cable PVC insulated sheathed 3 core copper conductor size 40/0.0076 mmcomplete all as specified and directed |
100 | Ditto all as per item No. 99 above here in beforebut 3 core copper conductor size 70/0.0076 mm |
101 | Ditto all as per item No. 99 above here in beforebut 3 core copper conductor size 110/0.0076mm |
102 | Supply only contactor single phase single pole 25 A ,220 Volt,50 Htz suitable for split AC out door unit complete all as specified and directed |
103 | Supply only Indoor blower motor for Split type AC 1.5 Ton capacity as existing make & model at site |
104 | Ditto all as per item No. 103 above here in beforebut for split AC 2.0 Ton Capacity |
105 | Supply only Blower motor for window type room air conditioner 1.5 Ton capacity as existing model at site |
106 | Ditto all as per item No. 105 above here in beforebut out door unit split type AC capacity 1.5 TR |
107 | Ditto all as per item No. 105 above here in beforebut out door unit split type ACcapacity 2.0 TR |
108 | Ditto all as per item No. 102 above here in beforebut Water cooler |
109 | Supply only air filter suitable for split type AC 1.5/2/3 Ton capacity all as per sample |
110 | Supply only 15 mm dia PVC (heavy duty) pipe for desert cooler |
111 | Supply only Blower fan blade complete for desert cooler all as per sample |
112 | Supply only Push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler |
113 | Supply only Condenser line filter for split AC /Refrigerator/water cooler |
114 | Supply only Submersible pump for desert cooler (in replacement) for lifting water upto 1.2 meter head. |
115 | Supply only Copper Pipe size 5/8"( with sleeves) |
116 | Supply only of Copper Pipe size 1/4"( with sleeves) |
117 | Supply only of Copper Pipe size 1/2"( with sleeves) |
118 | Supply only Copper Pipe size 3/8"( with sleeves) |
119 | Supply only insulation for cooper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia |
120 | Supply only of selector switch (single module switch type ) for desert Cooler as per sample |
121 | Supply only condenser fan suitable for Window type AC any capacity |
122 | Supply only condenser Fan Suitable for Split Type AC any capacity |
123 | Supply only blower for split AC 1.5 Ton capacity for indoor unit |
124 | Supply only blower for split AC 2 Ton capacity for indoor unit |
125 | Supply only Relay for voltage stabilizer 240 volts all as per sample |
126 | Supply only Volt meter 0-300 volts |
127 | Supply only Timer circuit for voltage stabilizer |
128 | supply only Connector porcelain type for voltage stabilizer |
129 | Supply only 15 mm dia PVC connection to water coolers 450 mm long |
130 | Servicing& cleaning of water cooler any capacity and any make at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condensor motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis, connecting & testing on load for performance complete all as specified and directed Note:Spareshall be measured and paid separately as supply only |
131 | Servicing & cleaning of refrigerator any capacity any make model cleaning the various components i. e Chill tray, Shelves, Freezer door, Door Gasket,Door Lock,Blub Holder & bulb and Food tray and replacemnt of minor spare parts complete all as specified and directed Note:Spareshall be measured and paid separately as supply only |
132 | Taking down and refixing of desert cooler installed upto (G+2) building and carrying out Servicing and painting of desert cooler at site or workshop by cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparation of surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and oiling the pump & motor complete all as specified and directed Note:Spareshall be measured and paid separately as supply only |
133 | Taking down and refixing of desert cooler installed upto (G+2) building and carrying out Servicing of desert cooler at site or workshop cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, checking the control wiring, fan & motor, tullu pump& motor complete all as specified and directed Note:Spareshall be measured and paid separately as supply only |
134 | S&FWood wool pad set suitable for desert cooler heavyy duty including dismantling the old unserviceable wood wool pad set complete all as specified and directed |
135 | Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing at site for split type air conditioner 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed |
136 | Ditto all as per item No. 135 above here in beforebut for split AC 2.0 Ton Capacity |
137 | Ditto all as per item No. 135 above here in before but for Water cooler of storage capacity60-120 Ltr |
138 | Ditto all as per item No. 135 above here in before but for Refrigerator above 195 Ltr |
139 | Re-winding of blower motor of desert cooler any capacity any make with supper enameled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, refixing the same complete all as specified and directed |
140 | Supply & fix kit fan motor single phase 230 V AC ,Copper wound ,900 rpm for Desert cooler. |
141 | Supply & fix exhaust motor single phase 230 V AC ,Copper wound ,18 inch,1400 rpm for Desert cooler . |
142 | Ditto all as per item No. 141 above here in before but suitable for plastic body Desert cooler of Make- symphany/ Bajaj or as existing at site of superior quality 3 speed motor |
143 | S & F in repair Circuit board PCB of Split Type AC complete for 1.5/2.0 TR Split type A/C and all as per directed |
144 | S & F in repair Circuit board PCB complete set for indoor & outdoor ofinverter type SplitAC of make Daikin/Carrier /Samsung/bluestar/LG as existing at site of capacity 1.5/2.0 TR Split type A/C all as per directed |
145 | Repair and maintenance of Circuit board PCB complete for 1.5/2.0 TR Split type A/C and complete all as per directed |
146 | S&F Indoor unit of split type AC capacity 1.5 TR including copper evaporator coil ,blower ,blower motor,controling circuit of AC complete all as specified and directed . |
147 | Ditto all as per item No. 146 above here in before but for Capacity 2.0 TR |
148 | Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5/2 Ton capacity and providing the new copper condensing unit of exsting size model in place including welding, brazing etc and tdesting on load all as specified and directed |
149 | Ditto all as per item No. 148 above here in before but evaporator coil |
150 | Ditto all as per item No. 148 above here in before but water cooler |
151 | Supply & Fix in repair wall mounted digital display voltage stabilizer copper winding, for automatic voltage correctionsingle phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity5 KVA. |
152 | Ditto all as per item No. 151 above here in before but 4 KVA |
153 | S&FSheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socketcomplete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed. |
154 | Disconnecting ,dismenteling and Taking out functional split AC and reassembling fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall including welding and brazing of copper pipe including charging of gas (if required)complete testing and making good to match with existing surface all as specified and directed by Engineer-in-Charge Note;-the rate for above item are deemed to include for necessary servicing cleaning & replacement of necessary u/s screw/nut/bolt/washer etc with new one,brazing of cooper pipe,transportation to any location inside AF campus. |
155 | M&L for repair to remote circuit complete with remote device for 1.5/2 TR window/split type AC and complete testing as per directed |
156 | S&F in repair MCB protected socket combination including MCB of capacity 25 amps withsteel sheet/plastic enclosure with plug topAC 230 V complete all as specified and directed |
157 | S&F in repairMCBsingle pole, 20 to 32Amps, 240 Volts 50 HZ,"C" series 10 KA breaking capacity complete all as directed. |
158 | S&F Sheet metal enclosure TPN 4 way double door distribution board,415 volt all as specified and directed |
159 | S&F Sheet metal enclosure SPN 8 way double door distribution board ,415 volt all as specified and directed |
160 | M&L ,T & P for detecting & rectifying leakage in split type ACas required at site and charging of refrigerant gas (R-22 /32/ 134 (a) / 410 a ) including welding brazing as reqdcomplete all as specified and directed. Note;-refrigerant gas shall be measured and paid seperately as"Supply Only" |
161 | Ditto all as per item No. 160 above here in before but for water cooler |
162 | Taking down old u/s M S bracket and S&F MS factory made bracket with powder coated, fixed on wall with necessary grouting MS bolt washer duly painted suitable for stalling outdoor unit of 1.5/2 tr AC complete all as specified and directed |
163 | S&F outdoor unit of split type AC capacity 1.5 TR including copper condensor coil ,condensor fan,blower motor,compressorcomplete all as specified and directed . |
164 | Ditto all as per item No. 163 above here in before but for Capacity 2.0 TR |
165 | M&Lfor submain wiring with two run of single core PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm FRLS 1100 volts grade and onerun of PVCinsulated unsheathed solid copper conductorcable of size 6Sqmm 1100 volts grade as earthcontinuity conductor drawn through in and includingrigid non metallic PVC concealed / surface conduit of suitable size onroof/wall/ceiling includingmaking good the disturbed surfaces ofwall etc complete all as specified and directed (Note : Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the unit rate). |
166 | M&Lfor submain wiring with two run of single core PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm FRLS 1100 volts grade and onerun of PVCinsulated unsheathed solid copper conductorcable of size 4Sqmm 1100 volts grade as earthcontinuity conductor drawn through in and includingrigid non metallic PVC concealed / surface conduit of suitable size onroof/wall/ceiling includingmaking good the disturbed surfaces ofwall etccomplete all as specified and directed (Note : Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the unit rate). |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail