Providing Infrastructure For Bpdav School, Midhani Townshippart -A: Civil Works For Extension Of 1St Floor At Primary Building, B.P.Dav School, Midhani Township And Part -B: Construction Of G+2 Rcc Framed Building At Bpdav School, Midhani Townshipnote: Co, hyderabad-Telangana

Mishra Dhatu Nigam Limited has published Providing Infrastructure For Bpdav School, Midhani Townshippart -A: Civil Works For Extension Of 1St Floor At Primary Building, B.P.Dav School, Midhani Township And Part -B: Construction Of G+2 Rcc Framed Building At Bpdav School, Midhani Townshipnote: Co. Submission Date for this Tender is 18-04-2024. Civil Work Tenders in hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

43072959
Providing Infrastructure For Bpdav School, Midhani Townshippart -A: Civil Works For Extension Of 1St Floor At Primary Building, B.P.Dav School, Midhani Township And Part -B: Construction Of G+2 Rcc Framed Building At Bpdav School, Midhani Townshipnote: Co
Open Tender
Indian
Telangana
hyderabad
18-04-2024

Tender Details

Providing Infrastructure For Bpdav School, Midhani Townshippart -A: Civil Works For Extension Of 1St Floor At Primary Building, B.P.Dav School, Midhani Township And Part -B: Construction Of G+2 Rcc Framed Building At Bpdav School, Midhani Townshipnote: Contractor Has To Quote Overall Price Viz Price + Taxes + Gst + Cess. The Accuracy Shall Be Up To Two Decimals

Key Value

Document Fees
Refer document
EMD
INR 200000.0 /-
Tender Value
INR 1.65 Crore /-

BOQ Items

Name of Work: PROVIDING INFRASTRUCTURE FOR BPDAV SCHOOL, MIDHANI TOWNSHIP Part -A: Civil works for extension of 1st floor at primary building, B.P.DAV School, Midhani Township and Part -B: Construction of G+2 RCC Framed Building at BPDAV School, Midhani Township Note: Contractor has to quote overall price viz price + taxes + GST + Cess. The accuracy shall be up to two decimals
Sl. No. Item Description
1PART-A : BOQ for Civil works for extension of 1st floor at primary building, B.P.DAV School, Midhani Township
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
3In cement mortar
4Dismantling ofRCC work by manually/ mechanical means including cutting reinforcement bars manually/by mechanical means in RCC works, stacking of steel bars and disposal of unserviceable concrete at a place directed by Engineer- in- Charge.
5Providing and laying in position ready mixed or site batched design mixM-25 grade cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.. (Note :- Cement content considered in this item is @ 350 kg/Cum.
6Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Thermo-Mechanically Treated bars of grade Fe-500D or more.)
7Providing Form work to sides of concrete, slabs, etc – Flat Surfaces complete as per instruction of E.I.C.
8i. Providing Form work to sides of concrete, slabs, etc – Flat Centering and shuttering including strutting, propping etc. and removal of form for :
9ii. above ground level- Lintels, beams, plinth beams, girders, bressumers, Slab Columns,and cantilevers etc,.
10Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
11i. Cement mortar 1:6 (1 cement : 6 coarse sand)
12a) Providing and laying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
13b) Providing and laying 12 mm cement plaster1:6 (1 cement : 6 coarse sand)
14c) Providing and laying 10 mm cement plaster1:6 (1 cement : 6 coarse sand) for ceiling
15Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
16New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
17Painting with synthetic enamel paint of approved brand and manufacture to give an even shade (Two or more coats on new work)
18Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
19Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
20New work (two or more coats) over and including water thinnable priming coat with cement primer
21Providing and laying polished shabad stone slab flooring over 25 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
22Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.
23Frame size 45 x 85 mm
24Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.
2535 mm thick
26Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
27Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) along with UPVC Grill made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
28Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
29Supplying and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm. Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, includingpreparation of surface but excluding grading complete with: Bitumen felt 3mm thick (hessian base) type 3 grade I conforming to IS : 1322. A Guarantee of 5 years from the date of Defect Liability period to be given by the contractor on Rs. 100/- stamp paper.
30Providing and fixing on wall face unplasticised Rigid PVC RAIN WATER PIPES conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.
31110 mm diaMeter
32Providing & Cutting grooves in brick wall of 6" width and 2" depth for laying IT & Telephone cables and make proper finishing with plastering in C.M (1:4) complete as per instruction of E.I.C.
33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 25 mm nominal dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete, including cutting chases and making good the walls etc as per direction of Engineer in Charge.
34Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 20 mm nominal dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete, including cutting chases and making good the walls etc as per direction of Engineer in Charge.
35Expansion joint treatment to the terrace Which includes 1. Surface preparation -Dismantling of dome structure, cleaning of the surface from dust, dirt & other contaminations. 2. Groove preparation- applying one coat of crystalline waterproof coating with Roofex XL/ Zoripex XL/ Power n crystal LQD (Armstrong/PMCC/EBT), applying one coat of latex based acrylic polymer bonding agent Roofbond ABR/ Zoribond SBR/ Power n bond SBR mixing with cement as per manufactures specification, providing and application of acrylic polymer modified reinstatement concrete/ mortar to finish the damaged egdes of joint and making the groove to a width of 25mm, providing & fixing of masking tap on top of the joint both sides. 3. Polysulphide sealant treatment to the expansion joints on terrace- Providing and fixing of back up support material of polyethelene foam to leave the depth of 12mm on the joint, providing and applicaying of one coat of polysulphide primer on inner edges of joint, providing and applying of two part polysulphide sealant to a width of 25mm to 12 mm depth with putty knife and neat finish, removing of masking tape and providing and applying of two coats of acrylic elastomeric cementitious coating. 4.supply and fixing of aluminum sheet over the expansion joints - with screws fitting to cover top side of the expansion joint treatment and then screw fitting with acrylic caulking compound.
365. specialised polyurethane sealant treatment of the terrace cracks-making V groove with pneumatic machinery, applying one coat crystalline waterproof coating, filling of the groove with polyurethane sealant. 6. specialised high bonding flexible bituminous polyurethane blended coating rubberized elastomeric flexible waterproof coating to the terrace- Applying one coat of high bonding, flexible bituminous polyurethane blended coating, then providng and laying of fibre mesh, high bonding flexible bituminous polyurethane blended coating, then applyof two coats of rubberized elastomeric flexible waterproof coating. 7. Refilling of the joint with reconditioning material and cement mortar treatment. Rate including materials, chemicals, machinery, labour charges, etc. as per instruction of EIC.
37Supply & fixing of Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer along with 2 coats of enamel paint all complete. The cost includes providing gas cutting including gas bottles, welding machines, welding rods , all tools required is in the scope of contractor etc., complete as per instruction of E.I.C.
38Providing of welding works for TMT steel bars (500 numbers different dia of bars) all columns, beams & slab, etc complete. The cost includes welding machines, welding rods , all tools required is in the scope of contractor etc.,The minimum 100 mm length welding with minimum 3 points at lapping zonecomplete as per instruction of E.I.C.
39Providing down drop walls with 6mm thickTMT bars, chicken mesh of 3mm thick (25mmx25mm gauge) and providing & laying 18 mm cement plaster on both sides in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement: 6 fine sand) complete.
40Providing and fixing Ist quality ceramic glazed wall tiles(Size-600X300mm)(Make-Jhonson, kajaria) conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
41Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to all/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks).
42Providing and fixing of roller blinds (recon make) for windows complete as per direction of Engineer-in-charge.
43Supply of labours
44(a) Skilled
45(b) Un-Skilled
46Electrical works
47Supply of 4C x 25 Sqmm PVC cable 660/1100 Grade, Cu stranded conductor, Color Coded , armored, Make KEI, Havells, KEC, Gloster,Polycab.
48Laying and termination of 4C x 25 Sqmm PVC cableas per instructions of engineer in charge.
49Supply of Lighting JB, Wall mounting Type, Industrial, With front Door /Cover , 3 Phase ,415 V, Incoming 63 Amps, 4 pole MCB, C Curve, Out Going , 6 Amps , Single pole, C curve, total 6 Nos and 16Amps Single pole C curve 3 noisemaker Legrand, Havells, Anchor, L&T.
50Erection and fixing of Lighting JB wall mounting type with necessarysupportas per instructions of engineer in charge.
51Supply of 2"x 2" LED lights , Flat diffuser type, Surface/recess mounting type,36W, 230Vac, Make- Havells, Phillips, Syska,Crompton, Bajaj.
52Installation and wiring of 2"x2" LED lights inside control room as per instructions of engineer in charge.
53Supply of 2.5 Sqmm PVC single core wire 1100 Grade, Cu stranded conductor, Color Coded , Make KEI, Havells, KEC, Gloster,Polycab.
54Laying and termination of 2.5 Sqmm PVC Flexible 1 C wire inside Conduits(including fixing of conduits suplied by MIDHANI)/over head manner on purlims and supports of shop floor at height of 13mtrs max as per instructions of engineer in charge. Clamps bend and Juction boxes necessary for conduit fixing shall be inscope of party
55Supply of 1.5 Sqmm PVC single core wire 1100 Grade, Cu stranded conductor, Color Coded , Make KEI, Havells, KEC, Gloster,Polycab.
56Laying and termination of 1.5 Sqmm PVC flexible single.core wire inside Conduits(including fixing of conduits suplied by MIDHANI)/over head manner on purlims and supports of shop floor at height of 13mtrs max as per instructions of engineer in charge.Clamps bend and Juction boxes necessary for conduit fixing shall be inscope of party
57Supply of 1.5 inch PVC conduits,1100V grade, with all required accessories like bends, joints, clamps ,JBs etc ( as and when required)
58Laying of PVC conduits with all accessories in concealed or surface manner as per instructions of engineer in charge.
59Supply of 12 Module PVC switch board, white, with two 6 Amps Sockets and 8x 6Amps switches, Make Legrand, Havells, Anchor,
60Installation and wiring of 12Module switchboardinside control room as per instructions of engineer in charge.
61Supply of 6Module PVC switch board, white, with two 6 Amps Sockets and 2x 6Amps switches, Make Legrand, Havells, Anchor,
62Installation and wiring of 6Module switchboardinside control room as per instructions of engineer in charge.
63supply of fan, 48inch dia, ceiling fans, with shaft length >700MM, 1 phase 230V rated, power consumption <100W ,
64Installationof fan, 48inch dia, ceiling fans, includes providing of cutouts in falce ceiling, fixing opf fans with mounting arrangement with wiring and earthing.
65Supply of 6Amps Switches, 1 Module, Make. Anchor, legrand , Roma
66Installation of 6Amps Switches, 1 Module, Make. Anchor, legrand , Roma
67Supply of 6/16AmpsSockets, 1 Module, Make. Anchor, legrand , Roma
68Installation of 6/16Amps Sockets, 1 Module, Make. Anchor, legrand , Roma
69Supply of 4step tiny fan regulator, 1 Module, Make. Anchor, legrand , Roma
70Installation of 4step tiny fan regulator, 1 Module, Make. Anchor, legrand , Roma
71PART- B: BOQ for Construction of G+2 RCC Framed Building at BPDAV School
72Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
73All kinds of soil. From 0.00m lvl to -1.5m lvl
74All kinds of soil. From -1.5m lvl to -3.0m lvl
75Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
761:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
77Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift.
78Providing and laying in position ready mixed or site batched design mixM-25 grade cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.. (Note :- Cement content considered in this item is @ 350 kg/Cum.
79Centering and shuttering including strutting, propping etc. and removal of form for :
80a) upto ground level- Foundations, footings, bases of columns, etc. for mass concrete.
81b) above ground level- Lintels, beams, plinth beams, girders, bressumers, Slab Columns,and cantilevers etc,.
82Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Thermo-Mechanically Treated bars of grade Fe-500D or more.)
83Brick work with common burnt clay F.P.S. (non modular) bricks of Cement mortar 1:6 (1 cement : 6 coarse sand) of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes.
84a) Providing and laying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).Cost includes all required tools and tackles for the said work and also the work needs to be carried out with height from ground level to +10 meters above ground level.
85b) Providing and laying 12 mm cement plaster1:6 (1 cement : 6 coarse sand)
86c) Providing and laying 10 mm cement plaster1:3 (1 cement : 3 fine sand)
87Providing and laying polished shabad stone slab flooring over 25 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
88Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
89Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. (New work (two or more coats) over and including water thinnable priming coat with cement primer)
90Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade for New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), Cost includes all required tools and tackles for the said work and also the work needs to be carried out with height from ground level to +10 meters above ground level.
91Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
92Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) along with UPVC Grill made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
93Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.
94Frame size 45 x 85 mm
95Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.
9635 mm thick
97Providing & Cutting grooves in brick wall of 6" width and 2" depth for laying IT & Telephone cables and make proper finishing with plastering in C.M (1:4) as per direction of Engineer-in-charge.
98Providing Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
99Supplying and applying bituminous solution primer on roof and / or wall surface at 0.24 litre per sqm. Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, includingpreparation of surface but excluding grading complete with: Bitumen felt 3mm thick (hessian base) type 3 grade I conforming to IS : 1322. A Guarantee of 5 years from the date of Defect Liability period to be given by the contractor on Rs. 100/- stamp paper.
100Supply & fixing of Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer along with 2 coats of enamel paint all complete. The cost includes providing gas cutting including gas bottles, welding machines, welding rods , all tools required is in the scope of contractor etc., complete as per instruction of E.I.C.
101Supply & fixing PVC out let pipe 110 mmdia(Make Sudhakar/ Ashirwad) pipe including all connected fittings like vent cap and clamping etc., complete as per direction of Engineer-in-charge.
102Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
103Providing and fixing Ist quality ceramic glazed wall tiles(Size-600X1200mm)(Make-Jhonson, kajaria) conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
104Providing and laying floor tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Antiskid finish of size
105Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
106Expansion joint treatment to the terrace Which includes 1. Surface preparation -Dismantling of dome structure, cleaning of the surface from dust, dirt & other contaminations. 2. Groove preparation- applying one coat of crystalline waterproof coating with Roofex XL/ Zoripex XL/ Power n crystal LQD (Armstrong/PMCC/EBT), applying one coat of latex based acrylic polymer bonding agent Roofbond ABR/ Zoribond SBR/ Power n bond SBR mixing with cement as per manufactures specification, providing and application of acrylic polymer modified reinstatement concrete/ mortar to finish the damaged egdes of joint and making the groove to a width of 25mm, providing & fixing of masking tap on top of the joint both sides. 3. Polysulphide sealant treatment to the expansion joints on terrace- Providing and fixing of back up support material of polyethelene foam to leave the depth of 12mm on the joint, providing and applicaying of one coat of polysulphide primer on inner edges of joint, providing and applying of two part polysulphide sealant to a width of 25mm to 12 mm depth with putty knife and neat finish, removing of masking tape and providing and applying of two coats of acrylic elastomeric cementitious coating. 4.supply and fixing of aluminum sheet over the expansion joints - with screws fitting to cover top side of the expansion joint treatment and then screw fitting with acrylic caulking compound.
1075. specialised polyurethane sealant treatment of the terrace cracks-making V groove with pneumatic machinery, applying one coat crystalline waterproof coating, filling of the groove with polyurethane sealant. 6. specialised high bonding flexible bituminous polyurethane blended coating rubberized elastomeric flexible waterproof coating to the terrace- Applying one coat of high bonding, flexible bituminous polyurethane blended coating, then providng and laying of fibre mesh, high bonding flexible bituminous polyurethane blended coating, then applyof two coats of rubberized elastomeric flexible waterproof coating. 7. Refilling of the joint with reconditioning material and cement mortar treatment. Rate including materials, chemicals, machinery, labour charges, etc. as per instruction of EIC.
108Providing and fixing colour coated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
109Plumbing Items
110a) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 25 mm nominal dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete, including cutting chases and making good the walls etc as per direction of Engineer in Charge.
111b) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 20 mm nominal dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete, including cutting chases and making good the walls etc as per direction of Engineer in Charge.
112c) Providing and fixing on wall face unplasticised Rigid PVC 75 mm dia RAIN WATER PIPES conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes (Make: Sudhakar/ Ashirwad).
113d) Providing and fixing on wall face unplasticised Rigid PVC 110 mm dia RAIN WATER PIPES conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes (Make: Sudhakar/ Ashirwad).
114e) Providing & fixing of Long body tap of 20mm nominal bore dia as complete.
115f) Providing & fixing angle cock 20mm nominal bore dia.
116g) Providing & fixing of stainless steel Push cock of approved make complete.
117h) Providing and fixing of Paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete.
118i) Providing & fixing of Pillar cock of 20mm nominal bore dia
119j) Providing and fixing of Health Faucet & Bib cock 2 in 1 tap 20mm nominal bore with plunge complete and all connected accesories.
120k) Providing and fixing of soap dispenser of good quality complete.
121l) Providing & fixing of C.P brass jalli of approved make.
122m) Providing & fixing of C.P brass hole jalli of approved make.
123n) Providing and fixing bevelled edge mirror of size 600 mm X 450 mm of superior glass (of approved quality) complete with 6 mm thickwith C.P. brass studs button type & conveyance of all materials to site and all operational ,incidentallabour charges etc, complete for finished item of work complete.
124o) Providing and fixing of PVC floor nahani traps including jointing with cement solvent complete in 75mm .
125p) Providing and fixing white vitreous china urinal basin (Parryware/cera/Hindware (Economical) with CP brass fittings such as speader with unions and clamps including 25mm CP concealed flush valve with isolation valve, CP brass flush bend also dome shaped waste coupling, union, nut 50mm dia PVC waste pipe clamped in walls with suitable trap leading up to the P Trap etc. including cutting and making good walls, including cost and conveyance of all materials to site,labour charges etc., complete for finished item work.
126q) Providing & fixing European water closet star white of approved make(Parryware/cera/hindware(Economical)), including the cost of providing & fixing seat cover, angle cock of approved by EIC, heavy duty PVC connection inlet pipe etc., closing the joints with white/ coloured cement wherever necessary as per the installation guide given in approved sanitary limited.
127r) Providing and fixing Water Closet squatting pan (Indian type W.C. pan) with 100mm P or S trap, Single Flush low level white P.V.C. flushing cistern (Sleek Fresh(ISI)) with manually controlled device (handle lever) conforming to IS : 7231, also including 15mm inlet connection with brass unions at ends including one 15mm angle valve with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. including P trap of indian W.C shall be encased on CC (1:2:4) 6" alround well above the joints to stop leakage at the joint etc, complete including cost of automatic PVC flush tank 5 litre capacity with flush pipe, ball cock, Angle cock, inlet & outlet arrangement and conveyance of all materials to site, cost of CC bed, labour charges and, charges etc., complete for finished item of work.
128s) Providing and placing on terrace (at all floor levels) polyethylene water storage tank of capacity 1000 litres (Sintex), IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
129Electrical Works
130Supply,laying and termination of 1.5 Sqmm Cu, stranded flexible wires, single core, color coded,FRLS,Make Havells, KEI, KEC, Finolex. Service part includes but not limited to laying of wire in Conduits or in surface manner and termination of wires as per instructions of engineer incharge.
131Supply,laying and termination of 2.5 Sqmm Cu, stranded flexible wires, single core, color coded,FRLS,Make Havells, KEI, KEC, Finolex. Service part includes but not limited to laying of wire in Conduits or in surface manner and termination of wires as per instructions of engineer incharge.
132Supply,laying and termination of 4 Sqmm Cu, stranded flexible wires, single core, color coded,FRLS,Make Havells, KEI, KEC, Finolex. Service part includes but not limited to laying of wire in Conduits or in surface manner and termination of wires as per instructions of engineer incharge.
133Supply,laying and termination of 4c x 6 Sqmm Cu, stranded,unarmored, XLPE, color coded,FRLS,Make Havells, KEI, KEC, Finolex. Service part includes but not limited to laying of wire in Conduits or in surface manner and termination of wires as per instructions of engineer incharge.
134Supply, fixing and wiring ofLED Tubelights with fightings and other accessory,20W(+/- 3W), 230Vac, flat diffuser type,surface mounting type. make - Bajaj, Havells, Phillips, Syska, Crompton. Service part includes but not limited to providing and fixing of lights in flase ceiling or surface manner with required accesories and wiring of light
135Supply, installation and fixing of 230Vac, ceiling mounted Fan 48Inch dia, 3 blades, shaft lenth 700mm with single module regulator and fan box. make havells, bajaj, crompton, Usha. service part includes but not limited to fixing of fan box inceiling mpunting of fan in false ceiling and wiring.
136Sypply and laying of 1" Conduits PVC type, with all accesories lile bend, junction box, clamps etc as and when required, Sudhakar make. Service part includes but not limited to chipping of walls, laying of conduits and plastering of wall if required as per instructions of engineer incharge.
137Sypply and laying of 1.5" Conduits PVC type, with all accesories lile bend, junction box, clamps etc as and when required, Sudhakar make. Service part includes but not limited to chipping of walls, laying of conduits and plastering of wall if required as per instructions of engineer incharge.
138Supply installation and Wiring of lightingDistribution Board 1, flesh mounting type, with front door , Incomming 63 Amps,4P,c curve,out going -3x 16Amps single pole single pole mcb, c curve, 3x6Amps, c curve mcb, make havells, legrand, L&T. Service part includes but not limited to fixing of DB in concealed manners with chipping and plastering of wall and terminations of Incomming and out going cables/wires.
139Supply installation and Wiring of1 PH lightingDistribution Board 2, flesh mounting type, witj front door , Incomming 63Amps,2P,c curve,out going -4x 16Amps single pole mcb, c curve, 2x6Amps, c curve single pole mcb, make havells, legrand, L&T. Service part includes but not limited to fixing of DB in concealed manners with chipping and plastering of wall and terminations of Incomming and out going cables/wires.
140Supply installation and Wiring of 12 module switch box, metal concealed box , with PVC frame and cover white color, including 4x fan regulators, and 6 amps switches as per requirement. Service part includes but not limited to chipping of wall fixing of metal box, plastering of wall if required as per instructions of engineer incharge
141Supply installation and Wiring of 6 module switch box, metal concealed box , with PVC frame and cover white color, including 1x 6Amps twin socket with shutter, and 6 amps switches as per requirement. Service part includes but not limited to chipping of wall fixing of metal box, plastering of wall if required as per instructions of engineer incharge
142Supply laying and termination of CAT 6 cable for internet points ,any reputed make. Service part includes but not limited to laying and termination of cables inside Conduit as per instructions of engineer incharge.
143Supply installation and fixing of 6 rack ethernet switch box, withOUT network switch, with front glass door. standard make.
144Supply erection and commissioning of earth pits as per IS 3043 as per instructions of engineer incharge.
145Sypply laying and termination of GI wire 12 SWG or higher for earthing of DBs as and when required as per instructions of engineer incharge.