Tender For Construction Of Academic-Cum-Workshop Buildings (G Plus 2) Having Foundation To (G Plus 3) Works At Osme Campus In The District Of Keonjhar For The Year 2023-24., keonjhar-Odisha

Civil Division has published Tender For Construction Of Academic-Cum-Workshop Buildings (G Plus 2) Having Foundation To (G Plus 3) Works At Osme Campus In The District Of Keonjhar For The Year 2023-24.. Submission Date for this Tender is 13-06-2024. Foundation Work Tenders in keonjhar Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

43067790
Corrigendum : Tender For Construction Of Academic-Cum-Workshop Buildings (G Plus 2) Having Foundation To (G Plus 3) Works At Osme Campus In The District Of Keonjhar For The Year 2023-24.
Open Tender
Indian
Odisha
keonjhar
13-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Construction Of Academic-Cum-Workshop Buildings ( G Plus 2 ) Having Foundation To ( G Plus 3 ) Works At Osme Campus In The District Of Keonjhar For The Year 2023-24.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Apr-2024 1ST CORRIGENDUM Date 13-06-2024

Key Value

Document Fees
INR 10000 /-
EMD
INR 1123000.0 /-
Tender Value
INR 11.22 Crore /-

Attachment

FileName File Description File Size
8c067843-53fd-48f0-a4e3-5810fe56215e.html Tender Notice 0 KB
BOQ_500792.xls Tender Document 0 KB
DTCN.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Construction of Academic-cum-Workshop Buildings (G+2) having foundation to (G+3) Works at OSME Campus in the District of Keonjhar for the year2023-24 .
Sl. No. Item Description
1CIVIL WORK Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc.as directed by the Engineer in charge.
2Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge
3Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.
4Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. (Head Room)
5Single under reamed bored compaction cast-in-situ RCC Pile with M-25 grade concrete including cost of boring to required dia meter and depth to plumb and taking precautionary measure against collapsing of side soil due to presence of water table using bentonite powder etc., concreting and driving the cage made of M.S. / T.S. steel as per approved drawing into the freshly laid concrete vertically by means of power winch to requied depth but excluding cost of M.S. / T.S. steel and labour charges for cutting, bending and binding of steel etc. complete confirming to IS-2911 specification including necessary routine tests including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the specification and instruction of Engineer-in-Charge.
6300mm dia
7375mm dia
8RCC work of M-25 grade in the following Structural building works using 20mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including mixing hoisting lowering laying compacting concrete using concrete mixer, vibrator watering and curing for four weeks centering and shuttering and finishing the exposed surfaces smooth as per relevant clauses of section 1700 of MORT&H specification for Road & Bridge works (4th Revision) including hire and running charges of all machineries including cost, conveyance, royalty and taxes of all materials and labour with T&P required for the work etc. complete as per drawing and Technical Specification and as directed by the Engineer-in- Charge.(Excluding cost of reinforcement & binding wires to be used in the work)
9BUILDING PROPER
10Footing
11RCC COLUMN SUPER STRUCTURE
12Ground Floor
13First Floor
14Second Floor
15Head Room
16RCC PLINTH BAND
17RCC LINTEL BAND
18Ground Floor
19First Floor
20Second Floor
21RCC FLOOR BEAM
22Ground Floor
23First Floor
24Second Floor
25Head Room
26RCC CHAJJA
27Ground Floor
28First Floor
29Second Floor
30Head Room
31RCC STAIRCASE
32Ground Floor
33First Floor
34Second Floor
35RCC ROOF SLAB
36Ground Floor
37First Floor
38Second Floor
39Head Room
40Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
41Ground Floor
42First Floor
43Second Floor
44Head Room
45Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
46Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
47Ground Floor
48First Floor
49Second Floor
50Head Room
51Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
52Ground Floor
53First Floor
54Second Floor
55Head Room
56Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
57Ground Floor
58First Floor
59Second Floor
60Head Room
61Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
62Ground Floor
63First Floor
64Second Floor
65Head Room
66Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory) ofapproved make (JOHNSON /OASIS / SOMANY/ KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4)(1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
67Ground Floor
68First Floor
69Second Floor
70Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mmof size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA/ RAK) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.
71Ground Floor
72First Floor
73Second Floor
74Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory)of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA/ RAK)as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.
75Ground Floor
76First Floor
77Second Floor
78Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
79Ground Floor
80First Floor
81Second Floor
82Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge) (Out Side)
83Ground Floor
84First Floor
85Second Floor
86Thired Floor
87Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge) (Inside)
88Ground Floor
89First Floor
90Second Floor Inside
91Thired Floor Inside
92Painting two coats withplastic emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ ICI/ Dulux/ equivalent make)
93Ground Floor
94First Floor
95Second Floor
96Head Room
97Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge).
98Ground Floor
99First Floor
100Second Floor
101Head Room
102Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
103Ground Floor
104First Floor
105Second Floor
106Head Room
107Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL )
108Ground Floor
109First Floor
110Second Floor
111Dressed seasoned sal woodworkframed andfixedinframesofdoors&windows including cost,conveyanceofall materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge .
112Ground Floor
113First Floor
114Second Floor
115Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.
116Ground Floor
117First Floor
118Second Floor
119Supplying, fitting and fixing of two track UPVC sliding window of apporoved make (Prominence / FENESTA/NCL VEKA LTD./ Koemmerling/ DURAPLAST) with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixturesincluding all cost,conveyance,royalty & taxes of all materials,labour,T&P required for the work etc. complete as per specification & direction of the Engineer-in-charge.
120Ground Floor
121First floor
122Second Floor
123Painting one coat with any approved primmer (To Receive Enamel paint) including cost of primmer & labour to give an even shade excluding cost of primerwith T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge).
124Ground Floor
125First floor
126Second Floor
127Painting two coat with approved synthetic enamel paint to new wood shine work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge).
128Ground Floor
129First floor
130Second Floor
131Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge).
132Ground Floor
133First floor
134Second Floor
135Head Room
136Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.
137Ground Floor
138Head Room
139E.I. WORK Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE or equievalant reputed makeA catagory ISI marked as approved with 20 mm dia PVC flexible non metallic conduit FRLStype ISI markedMake-NORPACK/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type (anti bactorial & flame retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells/Eq. of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approvedof suitable size, modular box with 1.5 sq. Mm FRLSHPVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.. All the switches & sockets should be warrantied for a replacement period of 5yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
140GROUP-A
141GROUP-B
142GROUP-C
143Group control of point in Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLSor equievalant reputed make A catagory ISI marked as approved as approved20 mm dia PVC flexible non metallic conduit FRLStype ISI markedMake-NORPACK/ Anchor or equievalant reputed make A catagory ISI marked as approvedwith 6A modular type((anti bactorial & falme retradant type)) switch ISI markedMake-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approved,and ceiling rose ISI markedMake-Schneider(Zencelo)/legrand( myrius) /Panasonic (Vision) or equievalant reputed make & model A catagory ISI marked as approved of modular type G.I box withmetallic cover plate (both side)(anti bactorial & falme retradant type) Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approved, of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
144Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approved,(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
145Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type))with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision)or equievalant make & model ISI marked as approved , (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 5 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
146Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type))with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make A catagory ISI marked as approved,(For equipement power)All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
147Supplying,fixing of 2x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+2 no 6Aswitch & socket(modular type) ( (anti bactorial & falme retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approved, (For equipement power.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
148Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos6Aswitch & socket(modular type) ( (anti bactorial & falme retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic(Vision) or equievalant reputed make & model A catagory ISI marked as approved, (For equipement power).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
149Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZHinsulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, inrecessed PVC conduit Heavy duty FRLS of mentioned size NORPACK/Anchor or equievalantISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
1502 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
1512 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5)
1524 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non metallicheavy duty flexible conduit(LDB to LSB/5A SOCKET) (4X2.5+2X2.5)
1532 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOORPOINT/DG PANELESSENTIAL LOAD) (2X4+1X1.5)
1544 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallicheavy duty flexible conduit.(PDB to PSB/GAYSER. POINT/AC POINT/DG PANEL ACCL TO EACH QTRESSENTIAL LOAD) (4X4+2X2.5)
1552 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5)
1564 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy duty flexible conduit.(LFDB TO LBDB/power unit/point) (4X6+2X2.5)
1574 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallicheavy duty flexible conduit .(LFDB TO FLOOR PANEL TO TPN BDB light ) (4X10+2X4)
1584 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductor in 40 mm dia non metallicheavy duty flexible conduit.(FLOOR PANEL TO TPN BDB power) (4X16+2X10)
159Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens/panasonic or equievalant reputed make & model A catagory ISI marked as approved,All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
160Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed plug top along with 32 amps. C-series, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge... Equievalant higher model ofMake-Legrand/Schneider/Siemens/panasonicequievalant reputed make & model A catagory ISI marked as approved.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
161Supplying and fixing following size/ modules, GI box along with modular base & metallic cover plate (both side)(anti bactorial type) plate for modular switches in recess etc as required as per direction of Engg.-in-Charge. MAKE-Legrand/Siemens/Anchor/Panasonic/ Schneider or equievalant reputed make & model A catagory ISI marked as approved .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
1624 moudle(125mmx75mm)
1631 moudle(75mmx75mm)
16412 moudle(200mmx150mm)
165Supplying and fixing of following sizes of medium class PVC FRLS conduitISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .MAKE- NORPACK/Anchor or equievalant reputed make A catagory ISI marked as approved
16620 MM
16725 MM
168Supply and fixingmodular type indicator on the existing switch box/cover . Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
169Supplying and installation of AC starter Modular type, Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
170Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Equievalant higher model ofSchneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
171S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
172Supplying,fixing of Blanking plate(modular type)( (anti bactorial & flame retradant type))in existing switch box(anti bactorial & flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..MakeSchneider(Zencelo)/legrand(Myrius)/Panasonic(Vision)/Eq..Itshould be warrantied for a period of 5 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
173Sub-Head II (Light fitting Fixture & Fan)
174Supplying, installation, of exhaust fan of heavy duty 300 mm sweep(Make-Equievalant higher model with star ratedof Havells/almonard/Anchor/Panasonic/Usha or equievalant reputed make & model A catagory ISI marked as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
175Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers Make-Equievalant higher model with star ratedof Havells/almonard/Anchor/Panasonic/Ushaor equievalant reputed make & model A catagory ISI marked as approved ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
176Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan Make-Equievalant higher model withstar ratedof Havells/almonard/Anchor/Panasonic/Ushaor equievalant reputed make & model A catagory ISI marked as approved) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) as required as per direction of Engg.-in-Charge.Replacement Warranty will be 5 years.
177Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan Make-Equievalant higher model withstar ratedof Havells/almonard/Anchor/Panasonic/Ushaor equievalant reputed make & model A catagory ISI marked as approved ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 5 years.. .(With fan Regulator)
178Supplying and fixing of Energy efficient Recess mounted LED luminaire made up of CRCA powder coatedsheet steel housingof 595 X 595 mm x 70 mmsize with of not more than36/34W and lumen efficacy of not less than (130 lm/ wt)withdiffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV,complete with Non integrated isolated electronic driver(protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Trilux /Philips/Wiproor equievalant reputed make & model A catagory ISI marked as approved.) . The luminaire must be Replacement Warranty will be 5 years.
179Supplying and fixing of Energy efficient surface mounted square shape 20 W LED luminaireof dimension of 225x 225 x 35 mm consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 2000 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (5 yrs warranty)and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. ( Make : Panasonic /Trilux/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved).The luminaire should be Replacement Warranty will be 5 years
180Supplying and fixing of Energy efficient recess mounted LED luminaire with white powder coated ,pressure die-cast Al housing ,with high transmititivity,non-yellowing PMMA diffuser, with wattage not more than 20watt and lumen output not less than 2600 Lumen ( 130 lumens/watt ) of size 595 x595 x 70 mm , ,CRI not lessthan 80,CCT of 5700-6500 degree K,THD less than 10%, with Non integrated isolateddriver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation), all other accessories , life : 50,000 burning hours (5 years warranty) , Internal surge protection of 3 KV suitable for operationon 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. ( Make : Panasonic/ LT /Wipro/PHILIPSor equievalant reputed make & model A catagory ISI marked as approved.) The luminaire should be Replacement Warranty will be 5 years.
181SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 5 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge. (Similar to Panasonic/PHILIPS/LT/wipro or equievalant reputed make & model A catagory ISI marked as approved.). The luminaire should be Replacement Warranty will be 5 years .
182SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. ( Make : WIPRO / PHILIPS/Panasonicor equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years
183SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K with 12 w/mtr @ 5Mtrpool with Driver extra as required as per direction of Engg.-in-Charge ( Make : PanasonicPHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years
184Supplying and fixing of small focus light for small monuments as 30W , 5700 Krequired as per direction of Engg.-in-ChargeMake : Panasonic/PHILIPS/LT/WIPRO or equievalant reputed make & model A catagory ISI marked as approved.)The luminaire should be Replacement Warranty will be 5 years
185Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
186BDBS,DB,AC DB,FLOOR PANELS,MCBS
187Supplying and fixing of following mentionedway, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ /ABB(Equivalant model) or equievalant reputed make & model A catagory ISI marked as approved.as per direction of Engg.-in-Charge. The Distribution boardsshould be Replacement Warranty will be 2 years
1884 Way(4+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 2 years.
189Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITHCORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD )
1902+4 way MCB EnclosureDB (GLAZEDdoor)(only each EM. CONNECTION UPS LOAD)
1918 Way(8+24) Way TPN MCB DDDB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)
192Supplying and fixing 20 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model) /ABB(Equivalant model) or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCBshould be Replacement Warranty will be 5 years .MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5 years.
193Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model) /ABB(Equivalant model)or equievalant reputed make & model A catagory ISI marked as approved.the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCBshould be Replacement Warranty will be 5 years.MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5years.
194Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA .Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC)AC ODU CONTROLLER). TheRCCBshould be Replacement Warranty will be 5 years
195Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years
196Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. TheRCCBshould be Replacement Warranty will be 5 years
197Supplying and fixing 63Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years
198Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCBshould be Replacement Warranty will be 5 years
199(Earthing) INSTALLATION
200S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITHcharcoal and salt) as required as per direction of Engg.-in-Charge.The entire earthing systemshould be Replacement Warranty will be 5 years
201S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years
202Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
203Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
204Providing and fixing 50mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
205Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge.
206CABLINGAND END TERMINATIONMAIN AREA
207Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradePOLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
2083.5core x 240 sq mm ( TO MAIN PANEL)
2093.5core x 120 sq mm ( DG PANEL1 RUNS )
210Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradePOLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
2113.5core x 95 sq mm ( FOR FDB 1F, POWER )
2124core x 16 sq mm (FDB LIGHT 1 RUN UPTO 1F )
2134 core x 4 sq mm (for small power)
2143.5core x 35 sq mm (To FDB LIGHT / power BDB/UPS PANEL,)
215LAYINGOF CABLE
216Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
217Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
218Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 120 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
219Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
220Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
221Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin open duct etc as required as per direction of Engg.-in -charge.
222Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMin open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
223Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
224Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
225Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
226Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
2273.5 core x240 sq mm
2284 core x16sq mm
2293.5 core x35 sq mm
2303.5 core x95 sq mm
2313.5 core x120 sq mm
232Providing,fixing and laying offollowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
23350 mm dia
234Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
235200 mm dia
236PANELS
237MAIN CONTROLPANEL AT GF
238S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list. In commer-1-01 numberof630A 4P Icu=100%Ics,0,LSIG MCCB with micro processor based release Electrical locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand/Eq., ISI marked). In commer-2-01 numberof250A 4P Icu=100%Ics, 0LSIG MCCB with micro processor based release with adjustable overload from 36%-100% & Electrical locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand/Eq., ISI marked) along with 01 no of 250A 4P onload changeover switch (125 KVA DG 01 NO).
239Busbar-1&2 04 numbers of 700Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator.(for outgoing). Out going- 08 numbers of 63A 4P MCB (make- Legrandor equivalent reputed make ISI marked)BDB P/AC,(timer panel & water supply management,,FIRE,WTP,STP & GF POWER). Out going- 5 numbers of160A 4P Icu=50%Ics, LSIG MCCB withTMR based release with adjustable overload(make- LEGRAND/Schneider/ABB/Siemens/Eq., ISI marked)(FLOOR RAW POWER PANEL ,SPARE,AC ). Out going-6 numbers of 32A 4P MCB ((make-ABB/ Siemens/ SCHNEIDER/ L&T/ Legrand/ Eq, ISI marked)(LIGHT SUPPLY). Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. (iii) 4 nos of 65kA SP VSD WITH 32A SP MCB.
240FDB LIGHT AT 1F,2F
241S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed asG.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDINGLIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list. In commer- 01 no 63A 4P MCB 10kA,Cseries with on/off trip indication Light load for each floor. ( Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model) /ABB(Equivalant model)or equievalant make with proper model ISI marked). Busbar- 04 numbers of63Amps,50kA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
242Out going-06 nos 32A 2P MCB 10kA,CseriesUPS Light load for each area UBDB. ( Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model) /ABB(Equivalant model)or equievalant make with proper model ISI marked). Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-60Amps Ammeter withCTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model). (iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
243FDBRAW POWER AT 1F,2F
244S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed asG.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER/AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list. In commer- 01 no 160A 4P MCCB 25kA, with ROM & S. Link. (make-ABB/Siemens/SCHNEIDER/L&T/Legrand/Eq, ISI marked)(Icu=100%Ics)with shunt trip.with axulary for BMSor equievalant make. Busbar- 04 numbers of125Amps,50kA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
245Out going-04 nos 63A 4P MCB 10kA,Cseriesfor power BDB. ( Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model) /ABB(Equivalant model)or equievalant make with proper model ISI marked). Out going-02 nos 32A 4P MCB 10kA,CseriesforExtra power BDB. ( Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/ABB(Equivalant model)or equievalant make with proper model ISI marked). Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set ofMFMwithCTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model).
246UPS PANEL FOREMERGENCY & LABORATORIES
247S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed asG.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list. In commer- 01 numbers of 63 Amps 4P MCB.(make-ABB/Siemens/SCHNEIDER/L&T/Legrand/Eq, ISI marked)(Icu=50% Isc) with shunt trip & axulary for BMS & mechnical inter locking for one incommer source to other.
248Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going-04 nos 32A 2P MCBUPS Light load for each floor. Out going-03 nos32A 4P MCB . Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-100Amps AmmeterDigital type & CTS.(DIGITAL). (iii) 01 set of 0-500 voltmeter Digital type.(DIGITAL) NB- This panel should have proper earth by suitable rated copper flat.
249UPS SYSTEM(For LAB & COMMON AREA)
250Supply ,installation ,testing & commissioning of10KVAUPS SYSTEM WITH suitable size battery bank, rated of battery ,IGBT based inverter system with inbuilt isolation transformer & automatic phase sicuency correctorof 3ph in put to 3 ph output,415V,protection for fault by OL,UV,EF,GF,OC,Ph. Sicuency release ofequievalant model ofNumeric/ RELLIO/ Emersion or equievalant reputed make A catogory, ISI marked as approved ) including supply of rack inverter stand with sufficient backup upto 30 minutes with all required accessories to complete the job including all connection.LOAD OF LAB & Common) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & systemmust be 2 years & compelete test certificate must be submitted along with upsincluding component list & SLD.
251HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 200mm(W),of Legrand - Cablofil make/Panduit/Eaton or equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
252HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 300mm(W),of Legrand - Cablofil make/Panduit/Eatonor equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
253HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 400mm(W),of Legrand - Cablofil make/Panduit/Eaton or equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
254GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions ofsize 38mm(H) x 225mm(W),of reputed make ISI marked as approved.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT,COST WITHOUT GST,WITH LESS DISCOUNT(REPUTED FACTORY MADE ISI MARKED)
255125 KVA DG
256Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of125KVAout put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. A. Alternator make : Kirloskar / Stamford / Crompton Greaves / Leroy Somer /Caterpillar or equievalant reputed make & model ISI marked as approved as per direction of Engg.-in-Charge. Warrentee period of panel must be 5 years & compelete test certificate must be submitted along with DG set including component list & smoke exhaust system drawing,certified ISO 8528. ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.
257ENGINE:Diesel Engine make : Kirloskar / Cummins / Caterpillar / Perkins /Volvo penta /Ashok Leyland / Mahindra & Mahindra / Greaves Cotton /Tata or equievalant make & model ISI marked as approved . Diesel Engine start, developing suitableBHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 125KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 10 Hours running capacity. 03. Residential Silencer. 04. SMF Batteries with leads as per the Manufacturer standards AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 125KVA DG Set complete with Battery Charger & leads as required.
258BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along withsmoke exhaust system piping including base frame of structure & lightening protection system. *It also includes 2 nos GI pipe earthing for body and 2 nos copper plate earthing for neutral, control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)
25910 PASSENGER LIFT WITH WIRRING(1.1)
260Design Supply, Installation, Testing & Commissioning and putting into operation with compelete inspection by concerned electrical inspector, Director Factory and Boilers, Odisha with proper testing certificate and final testing of Automatic Lift complete with all standard equipments accessories and control equipments as per Manufacturer"s Design with lift control panel including BMS facility and as per BIS and fulfilling following requirements.It includes supply,laying of power cable and fixing of glands,lugs etc.( Machine room less, Gearless Type).Design and as per CPWD /OPWD specification (Part - III Lifts) 1981 with valid lisence for installation and fulfilling following requirements on turnkey basis as per direction of Engg.-in-Charge.LIFT OF machineroom less type(Make-Kone/Jhonson/OTIS/Schindler/Thysenkrup or equievalant reputed make & model A catogory, ISI marked as approved )Warrentee period of accessories & system must be 5 years & compelete test certificate must be submitted along with Liftincluding component list .
261Type:PASSENGERLIFT Load: 10 PASSENGER(680KG) Speed: 1.0 Meter Per Second. Control: Variable voltage with variable frequency Operation:Microsprocessor based simplex collective selective with / without Lift Attendant. Total Rise: About 10 Meters. Landings: For All on same side. Floors Served: GF,1F,2F Signals: Digital Car Position Indicator, Car Travel direction Indicator in Car & at all Landings. Lift Shaft Size: About as 10 passengerlift standard, finished with Plaster. Lift Car Size: Aboutlift standard. Car Entrance: Clear Openinglift standard high Protected with Car Door. Landing Entrance: Clear Openinglift standard high Protected with Landing Door. Car Door: Stainless steel with front glass to transparentTwo Panel Center opening flush type.outer visible. Landing Door:Stainless Steel Panel with Hair line finish Two Panel Center opening flush type P.
262Door Operation: Automatic Electric Power operated Door with in infrared protection. Car Interior: Stainless Steel Panel with Hair line finish on all sides. Car Floor: Hard Wood covered with PVC / Marblex Tiles. Car Ceiling & Lighting: LED Lighting Concealed by suspended false ceiling with plain acrylic diffiuser. The frame of suspended false ceiling shall be of powder coated Aluminum. Car Ventilation: Pressure Fan with anodized Aluminum Grill. Emergencing Lighting in Car: Battery operated Emergencing Lighting in the Lift Car. Intercom System: Battery operated intercom system in Lift Car and Control Room. Emergencing Alarm: Battery operated Alarm Bell System in Lift Car and Control Room. Position of Machine Room: Directly above the Lift Shaft. Electric Power Supply: AC 415 Volt 3 Phase 50 Hz terminated in control room along with control panel with facility of BMS connectivity system .The scope of lift control panel is inclussive with lift vender scope.
263OTHER SPECIAL PROVISIONS • VVVF CONTROLLER • AUTOMATICE RESCUE DEVICE (ARD) • EMERGENCY LIGHT AND BATARY OPERATED ALARAM BELL • DOT MATRICKX SEVEN SIGMENT DIGITAL POSITION INDICATORS • FIRE RATED DOOR FOR 2 HOUR • 3 WAY INTER COM/PRESS AND SPEAK BUTTON WITH HAND SET • FLOOR ANNUNCIATOR WITH MUSIC • INFRA RED SCREEN • OVER LOAD WARNING INDICATOR • BRAILLE BUTTONS • FREE SERVICE FOR 5 YEARS • PIT LADER • FULL CAR HEIGH CAR FIXTURE ARRIVAL CHIME • PROVISION FOR CC CEMARAWITH INSTRUEMENT Fire Man Switch: Fire Man Switch at Main Landing Terminal.
264EXTERNAL STREET LIGHT SYSTEM
265Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegant look Panasonic/philips/wiproor equievalant reputed make & model A catogory, ISI marked as approved 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel will be vide Panasonic / Philips/LT/WIPRO makeor equievalant reputed make A catagoryISI marked as approved having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge.
266Supplying, Erection, Fixing, connection & testing of Panasonic 40 w LED GATE Light ofPanasonic / Philips/LT/WIPROor equievalant reputed make A catagoryISI marked as approved maintenance free having 2 years warrantyG.I P ipewith braket including MCB box & including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
267Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years
268Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge.
269Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
270S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type MCB ENCLOSUREmade out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing. (FOR USE) with 20A TPN MCB 01 NOLegrand/Schneider/L&T/ABB or equievalant make & model as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 2 years ofacceptance of materials
271Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
272(LIGHTENING CONDUCTOR)
273AIR TERMINAL & ACCESSORRIES LIGHTNING ARRESTER+ MAST:Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, G.I tube,having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc complete as required with as per direction of Engg.-in-Charge.(RATE REFERING OSR 2018 SOR NO-4.2) .The entire LA systemshould be Replacement Warranty will be 5 years
274Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required .as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.4) The entire LA systemshould be Replacement Warranty will be 5 years
275Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) as per direction of Engg.-in-Charge.(RATE REFERING OSR 2018 SOR NO-4.7)The entire LA systemshould be Replacement Warranty will be 5 years
276Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For virticalrun) as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.8) The entire LA systemshould be Replacement Warranty will be 5 years
277Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.12) The entire LA systemshould be Replacement Warranty will be 5 years
278Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required as per direction of Engg.-in-Charge. .(RATE REFERING OSR 2018 SOR NO-4.14) The entire LA systemshould be Replacement Warranty will be 5 years
279Maintenance free Safe Earthing Electrodeswith ISI G.I. pipe dia 75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S. hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the Surface Area in will be 7,06,500sqmm for 3mtrs length and Cross Sectional Primary conducting area is 300 sq.mm. An Solid G.I. Base platseals the unit at the bottom.as per direction of Engg.-in-Charge. (MES-GFC ground Filling compound will be provided in 25 kgs Bags.)(MES-GFC ground Filling compound will be provided in 25 kgs Bags.)(2 bags required for each earthing electrode.)(FOR lightening protection & Building Electrification).The entire earthing systemshould be Replacement Warranty will be 5 years.Make-OBO/Star-x/ABB or equievalant reputed make & model A catogory.
280SPLIT TYPE AIR CONDITIONER WITH ALL ACCESSORIES
281AIR CONDITIONER
282Supply of A,C with indoor and outdoor unit
2831.5 TR high wall split A.C 3Star (Make:Toshiba/Hitachi/Carrier/Diakin or eq.
284REFRIGRANT PIPING
285Supply,installation of hard/soft copper refregrant piping,complete with fitting of bends and other nesessary material to complete the job.
2861.5 TR high wall split A.C
287FRAME WORK
288Supply,installation & fabrication ofMS base frame for both indoor and outdoor unit and other nesessary material to complete the job.
2891.5 TR high wall split A.C
290DRAIN PIPING
291Supply,installation & fabrication ofInsulated drain water piping from indoor to nearestdrain point separate to alland other nesessary material to complete the job.
29225mm nom. Dia pipe,B1
293SHEET METAL WORKS
294CONTROL CABLE Supply,laying of control cableand other nesessary material to complete the job.
2951.5 TR high wall split A.C
296PUMPS AND APPURTENANCES
297Supplying, installation, testing and commissioning of Electric Motor DrivenPressurization Terrace Pump having discharge of 450 LPM at 35 MWC head complete with Pump Set, Electric Motorsuitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame asrequired.(Make:PUMP:KBL/ Grundfos / KSB/ Wilo/Eq.)
298Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrinkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of.One (1)-63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB,Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable formotor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.
299One (1) - Set of Auxilliary relay for automatic operation through pressure switch.
300PANEL AS ABOVE
301Supply & Laying of XLPE power cable of 1.1 KV grade of following size on Cable.Make-Polycab/Finolex/Eq.
3023C X 70 sqmm
3033C X 16sqmm
304Cable tray
305Supplying instalaltion hot dip galvanized ladder type cable tray of following size including installation along wall/ suspended from ceiling with brackets/ threaded suspenders including bends etc as required.
306150 mm (W) X 50 mm (H) with 1.2 mm thick sheet
307450 mm (W) X 50 mm (H) with 1.6 mm thick sheet
308Cable laying
309Laying & fixing of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on Cable Tray as required.
310Upto 35 Sqmm
311Above 35 Sqmm and upto 95 sqmm
312End Termination
313Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)
3143C X 70 sqmm
3153C X 16sqmm
316PIPE & VALVES ETC.
317Supply,Installation,Testing & Commissioning of "C" Class heavy duty MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above 150 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-Sail/TATA/Jindal/Eq.
318100mm NB
31980mm NB
32025mm NB
321Supply,Testing & Commissioning of "C" Class heavy duty MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above 150 mm 6mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size including laying in ground after excavation and refilling of trench along with providing 4mm thick pipecoat for underground pipe after applying wrapping coating primer as required as per direction of Engineer-in- charge.Make-Sail/TATA/Jindal/Eq.
322150mm NB
323Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/Kartar/Kirloskar/Eq.
324150mm NB
325100mm NB
326Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge..Make-Zoloto/Kartar/Kirloskar/Eq.
327150mm NB
328100mm NB
329Supply,Installation,Testing & Commissioning of orifice plate made of 6mm thick stainless steel with orifice of required size in between flane and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg/ sq cm complete as required.
330Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Makw-H.Guru/G.Guru/Eq.
331Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Indfoss/Grundfos/Eq.
332Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. .Make-Zoloto/Kartar/Kirloskar/Eq.
333100mm NB
334Supply,Installation,Testing & Commissioning ofAir vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required.
335Supply,Installation,Testing & Commissioning of 150 NB C.I. PRVwith matching flanges as per direction of Engineer-in-charge.
336WET RISER CUM DOWN COMER SYSTEM
337Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge. Make-Newage/Minimax/Firesheld/Safex/Eq.
338Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge..Make-Newage/ Minimax/ Firesheld/ Safex /Eq.
339Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with63mm intstantaneous stainless steelmale & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge..Make-Newage/ Minimax/ Firesheld/ Safex/ Eq.
340Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge..Make-Newage/Minimax/Firesheld/Safex/Eq.
341Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge..Make-Newage/Minimax/Firesheld/Safex/Eq.
342Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge.
343Providing, fitting & fixing of 4-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EICMake-Zoloto/Kirloskar/Audco/Eq..
344EXTINGUISHER SYSTEM
345Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Fireshield/Safex/Kanex/Ceasefire/Eq.
346Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Fireshield/Safex/Kanex/Ceasefire/Eq.
347Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher,ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket as per direction of Engineer-in-charge.Make-Fireshield/Safex/Kanex/Ceasefire/Eq.
348Providing and fixing the signages "Fire Exit, Fire Exit Arrow Down,Fire Exit Arrow Left,Fire Exit Arrow Right" of 1.5in height letters in white with green back ground.The size of the board shall be 25cm x 15 cm and shall be fixed at the height of 2 mts
349AUTOMATIC FIRE ALARMING SYSTEM
350Supply, Installation,Testing & Commisioning of Microprocessor based 2 loop fire alarm control panel with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards,provision for externel & internal printer(if required), L C D unit to indicate Fire/Fault Signal with address and analog output, built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system. Make:MORLEY IAS/Simplex/Edward/Hochiki/Siemens/Eq.
351Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multi sensing detector with two inbuilt optical smoke & heatsensors with light anglesas per NFPA style 7 wiring complete with base as required.Make:MORLEY IAS/Simplex/Edward/Hochiki/Siemens/Eq.
352Supply, Installation, testing andCommissioning of addressable manual call box made of polycarbonate with plastic break glass front and complete with monitor module MCB shall be recessed in wall . Make:MORLEY IAS/Simplex/Edward/Hochiki/Siemens/Eq.
353Supply Installation, Testing & Commissioning of Response Indicator single LED / 2 LED.Make:Honeywell/ASES/Agni/Eq.
354Supply Installation, Testing & Commissioning of wall mounting loop powered addressable type hooter with strobewith all accessories as per specification.MORLEY IAS/Simplex/Edward/Hochiki/Siemens/Eq.
355SITC of 2 core 1.5 .sq.mm multi stand copper conductor , FRLS Armoured cable with Saddle and required accessories .Make: Polycab/RR/Havells/Eq.
356SITC of addressable loop powered monitor module complete as required . Make:MORLEY IAS/Simplex/Edward/Hochiki/Siemens/Eq.
357Supply and fixing metal box of following sizes on surface or in recess with suitable size of phenolic laminated ,sheet cover in front including painting etc .as required . 100mm x 100mm x 60mm deep.
358SITC of output loop powered control relay module. Make:MORLEY IAS/Simplex/Edward/Hochiki/Siemens/Eq.
359PA SYSTEM
360Supplying, installing, testing and commissioning of P.A. controller with 16 Zone PA paging station 16 zone with priority module micro processor based, mixingamplifier, with 6 zone for suitable selection module, power supply unit & goose neck micro phone etc.Make. Honeywell/Bose/Ateis/JBL/eq.
361Supplying, installing, testing and commissioning solid state Compact 480w Power Amplifier The amplifier should be clean reliable audio for public address amplification. Line input less than 1 volt, unbalanced and line output less than 1 volt unbalanced.Make.: Honeywell/Bose/Ateis/JBL/Eq.
362Supplying, installing, testing and commissioning of 12 Watt wall mounted speakers with built in line matching transformer, grill flush mounting type in side the utility rooms.Make. Honeywell/Bose/Ateis/JBL/Eq.
363Supplying and drawing of speaker cable single pair ,2-core 1.5 sqmm in existing conduits .Make: Polycab/Havells/RR/eq.
364Supplying, installing, testing and commissioning of 19" Rack 650mm depth, 17 U high amplifier rack assembly made of aluminum channel equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Fans shall provided at the top for ventilation side panels will be ventilated type. The rack shall be powder coatedof approved color and spare "U" shall be covered with blank panels.Make. Honywell/Bosch/eq.
365Supplying, Installation, testing and commissioning Biometric Controller Finger printalongwith all required accessories as per direction of Engg.-in charge .Make-Vairack/Secureye -[S-B251CB]/Retail/Eq
366Supply & laying of Cat 6 Cable inPVC Pipe or Double lock casing caping including all accessories, per running metre of cable used as per direction of Engg. In charge. Make-Legrand/retail/eq.,pipe-NORPACK/EQ Pipe
367Supply & laying of Concealed Wall chasing includinginstallation of PVC pipe in a concealed manner per running metre of pipe laidas per direction of Engg. In charge. Makepipe-NORPACK/EQ Pipe
368Supplying, Installation, testing and commissioning Biometric ControllerBiometric Controller- 1 Door Finger print + RFID Readeralongwith all required accessories as per direction of Engg.-in charge. Make-Secureye[S-B100CB]/Vairack/Retail/Eq
369Supplying, Installation, testing and commissioning electrical & mechnical locking 600 Lbs Single Doorsystem along with all required accessories as per direction of Engg. In Charge Lock600 Lbs Single Door Make- Secureye /Vairack/Retail/Eq
370Supplying, Installation, testing and commissioning of exit Switch - - Exit Switch with all required accessories as per direction of engg. In charge. Make-Secureye /Vairack/Retail/Eq
371Supplying, Installation, testing and commissioning electrical & mechnical locking E/M Lock Bracket - Z Bracket along with all required accessories as per direction of Engg. In ChargeMake-Vantage/ Vairack/Retail/Eq
372Supplying, Installation, testing and commissioning DC Power Supply- 12V 5,along with all required accessories as per direction of Engg. In Charge Amp Make- ERD[AD-125AOD (PS012)]/Vairack/Retail/Eq
373Supply & laying of Cat 6 Cable in PVC Pipe or Double lock casing caping including all accessories, per running metre of cable used as per direction of Engg. In charge. Make-Legrand/retail/eq.,pipe NORPACK/AKG/EQ Pipe
374SL - 2C 1.0 PC - AKG/eq. Pipe Supply & laying of 2 core 1 sq mm power cable inPVC Pipe/Double lock casing caping including all accessories, per running metre of cable used..( As Required )
375Supply & laying of Concealed Wall chasing includinginstallation of PVC pipe in a concealed manner per running metre of pipe laidas per direction of Engg. In charge. Make pipe-NORPACK/ AKG/EQ Pipe
376Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit, Make: Legrand/Systimax/Panduit/Schnieder/Eq.
377Supply & fixing of RJ-45Jack of Category 6 with Dual-port British-style Face plate 86x86 mm with Curveture and wall mount box Make: Legrand/Systimax/Panduit/Schnieder/Eq.
378Supply & fixing of Cat6 24 Port Loaded Patch Panel:make:Legrand/Systimax/Panduit/Schnieder/Eq.
379Supply & Installation of Cat6 Factory crimpped moulded patch cord,1mtr, Make :Legrand/Systimax/Panduit/Schnieder/Eq.
380Supply & Installation of Cat6 Factory crimpped moulded patchcord, 2mtr. Make: Legrand/Systimax/Panduit/Schnieder/Eq.
381Supply & Installation of 6F Single Mode Armoured FO Cable through existing conduit. Make: Legrand/Systimax/Panduit/Schnieder/Eq.
382Supply & Installation of 24 Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit/Schnieder/Eq.
383Supply & Installation of Single Mode SC-LC Type OFC Patch Cord, 2mtr length. Make: Legrand/Systimax/Panduit/Schnieder/Eq.
384Supply & Installation of 1000Base LX Fiber Transceiver. Make: Cisco/Juniper/Honeywell/Eq.
385Supply & Installation of 24 Port1 10/100/1000MbpsL2+ Managed PoE Switch with 4 SFP Ports Make: Cisco/Juniper/Ruckus/Eq.
386Supply & Installation of 9U/500Wall Mount Rack with FAN, PDU, Cable manager and H/W Pkt. Make : Legarnd/Valrack/Schnieder/Eq.
387Supply & Installation of 24U/600D Floor Standing Rack With FAN, PDU, Cable manager and H/W Pkt. Make: Legarnd/Valrack/Schnieder/Eq.
388Subhead- 1.a (IP-PBX System)
389Supplying and fixing of Hybrid EPABX system equipped with 128 Analog extensions and 6 Analog Trunk, including required hardware and software etc as reqd. Legrand/Systimax/Panduit/Schnieder/eq
390Supplying desktop telephone sets with colour ID as reqd (for Hostel room extensions)
391Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in thesurface/ recessed steel/ PVC conduit as required.
3922 Pair
39320 Pair
394S/F DP box suitable for above as reqd
39550 Pair
396200 pair
397Supply installation testing and commssioning Basic SIP Backlit IP Phone as reqd. (Model to be decided by Engineer in charge)
398Supply installation testing and commssioning Executive SIP Backlit IP Phone (Model to be decided by Engineer in charge)
399Supply installation testing and commssioning SIP Baed IP video Phone (Model to be decided by Engineer in charge)
400Supply & laying of Cat6A LSZH horizontal cable following proper EIA/TIA standardsin thePVC conduit as reqd. Legrand/Systimax/Panduit/Schnieder/eq
401Subhead- 3 (IP-CCTV System)
402Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Ball Camera, 1/3" CMOS or better, 5MP (2560 x 1440) @ 25fps or better, triple stream at various resolution up to 25fps, Min. Illumination required 0.005 lux (color), 0 Lux IR On, Inbuilt Smart IR with upto 30m IR distance, ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/5 - 1/100,000s; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:94°, V:50°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Indoor/Outdoor/Manual, Minimum Edge Video Analytics : Video Motion Detection, Tampering, Video Exception Scence Change & Video Blur, Intrusion, Line Crossing, One Way Audio, Inbuilt Mic, G.711A/G.711U, 4 Privacy Mask, 8 Region Of Intreset, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, 256GB SD card support,PoE (802.3 af) and 12V DC, Max 5W, IP 67 & Ik10, Having Operating temp range : –30°C to 60° C, Reletive Humidity up to 90% NC, Certifications: ONVIF Profile S/G/T compliant, Safety (IEC 60950-1, IS 13252-Part1), EN 55035, FCC Part 15, EN 55032 & RoHS (IEC 62321)compliant.Make-Honeywell/Pelco/Axis/Eq.
403Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Bullet Camera, 1/3" CMOS or better, 5MP (2560 x 1440) @ 25fps or better, triple stream at various resolution up to 25fps, Min. Illumination required 0.005 lux (color), 0 Lux IR On, Inbuilt Smart IR with upto 30m IR distance, ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/5 - 1/100,000s; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 3.6mm, Field of View FoV H:76°, V:40°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Indoor/Outdoor/Manual, Minimum Edge Video Analytics : Video Motion Detection, Tampering, Video Exception Scence Change & Video Blur, Intrusion, Line Crossing, One Way Audio, G.711A/G.711U, 4 Privacy Mask, 8 Region Of Intreset, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, 256GB SD card support,PoE (802.3 af) and 12V DC, Max 5W, IP 67 & Ik10, Having Operating temp range : –30°C to 60° C, Reletive Humidity up to 90% NC, Certifications: ONVIF Profile S/G/T compliant, Safety (IEC 60950-1, IS 13252-Part1), EN 55035, FCC Part 15, EN 55032 & RoHS (IEC 62321)compliant.Make-Honeywell/Pelco/Axis/Eq.
404Supply & Installation of 32 Channel fully Featured NVR with High decoding capability for Ultra 4K HD viewingup to MP(4K) resolution live view, Preview & Playback, Internal storage supports 2 HDDs(8TB each). Record bit Rate (320Mbps), 2 HDMI/ VGA simultaneous video, usb ports 3 (2 rear USB3.0; 1 front USB2.0. RS232 1 port (for PC communications and keyboard).) The Quick Wizard and no PoE support . Should have post event recording interval 30s (max 60s ).Should have camera Alarm in ,(smart) motion detection,video loss, camera tamper intrusion,Multi loitering ,crowd detection .Resolution should be upto 3840x2160 and frame rate 30 fps .Make-Honeywell/Pelco/Axis/Eq.
405Supply & Installation of surveliance 8 tB HDD .Make:WD/Segate/Toshiba/Eq.
406Supply & installation of 55"" IPS Ultra HD AI ThinQ TV.Make:LG/Samsung/Sony/Eq.
407Supply and Laying of cat6 23Awg UTP cable through existing conduit, Make: Legrand /Tyco/Digisol/Eq.
408Supply & fixing of cat6 24 port Loaded patch panel .Make:Legrand/Tyco/Digisol/Eq.
409Supply &installation of 24 port 10/100/1000 Mbps L2+ Managed POE switch with 4 SFP ports .Make: Cisco/Juniper/Digisol/Eq.
410Supply & Installation of 9U/500 Wall Mount Rack with FAN ,PDU, Cable manager and H/W Pkt. .Make:Legrand/Vairack/Retail/Eq.
411P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.
41220mm dia C - PVC pipe
413In Ground floor
414In First floor
415In Second floor
41625mm dia C - PVC pipe
417In Ground floor
418In First floor
419In Second floor
42032mm dia C - PVC pipe
421In Ground floor
422In First floor
423In Second floor
424Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.
42540mm dia ASTM(Sch-80)PVCpipe
426In top floor
42750mm dia ASTM(Sch-80)PVCpipe
428In top floor
429supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite,payment of royality, taxes etc. all complete as perdirection ofEngineer-in-charge.
430250mm thick wall
431In Ground floor
432In First floor
433In Second floor
434Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge
435In Ground floor
436In First floor
437In Second floor
438Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damagesincluding watering ,curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.
439In Ground floor
440In First floor
441In Second floor
442Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materialsincluding cost & conveyance of all materials to worksite, payment oftaxes etc. allcomplete as per P.H specification and direction of the Engineer-in-charge.
44315mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
44415mm dia CPBib cock (Con-CHR-047KN Jaquar make)
44515mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
44615mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
44715mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
44815mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
44925mm dia brassfull way valve (Shakti make)
45032mm dia brassfull way valve (Shakti make)
45140mm dia brassfull way valve (Shakti make)
45250mm dia brassfull way valve (Shakti make)
45315mm CP Extension piece
454125mm size C.P. Gratting
45515mm CP flange
456Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction ofEngineer-in-charge
4572000 liters capacityPVC water storage tank roof of 2nd floor
458Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter"s along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge
459Aqua guard pure Chill 80 PSS UV
460Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment oftaxes etc.all complete as per P.H specification and direction of the Engineer-in-charge.
461110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
462110mm U-PVC‘P’ Trap(Ori Plast/Finolex/Supreme Make)
463110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
464110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
465110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
466110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
467110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
468110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
469110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make)
470110mm U-PVC Door cross tee(Ori Plast/Finolex/Supreme Make)
471110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
472Supplying all materials , labour, T&P and cutting holes through existing brickor laterite masonry wall for takingU-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
473250mm to 375mm thick wall
474Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
475Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI "p" or "s" trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
476580mm size Orissa pan (Hindware/Parryware/Neycer make)
477Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral "p" or "s" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
478European water closet(Hindware/Parryware/Neycer make)
479EWC(Matrix set)No.70002(P-18)
480Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge
48110 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
482Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal
483Half stall Urinal
484Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge
485Under Counterbasin(560x450)Hindware-No.10095
486Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink Zyna Make
487Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.
488Large Size mirror with Frame (18x0.90x0.75)= 12.15
489Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
490Towel ring
491Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
492CP soap holder
493Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge
494In Ground floor
495Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
496In Ground floor
497Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
498In Ground floor
499In First floor
500In Second floor
501Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P, etc. all complete as per the direction of Engineer-in-Charge.
502First Floor
503In Second floor
504Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( Vitrifiedfloor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed seriesto be pre-approved by the Engineer-in-charge )
505Kajaria/Somany/Johnson tile 60cmx60cm
506First Floor
507In First floor
508In Second floor
509Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
510In Ground floor
511In First floor
512In Second floor
513Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirtingon 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( Vitrified mat finish wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )
514Kajaria/Somany/Johnson tile 60cmx30cm
515In Ground floor
516In First floor
517In Second floor
518Granite Tiles 10mm thick
519for Counter top W.H.B.
520In Ground floor
521In First floor
522In Second floor
523for sink
524In Ground floor
525In First floor
526In Second floor
527Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.
528Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge.
529Supplying all materials ,labour ,T&P and constructing Gully Trap Chamber ofinside size 250mmx250mmx250mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge
530Inside size 25cmx25cmx25cm with 8” dia RCC MH cover
531Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge
532Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
533Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification.
534MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
535Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
536Inside size 1.40m dia x 2.00m deep soakway pit
537Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture"s specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge
538110mm dia U-P.V.C. pipe(All round Concrete)
539160mm dia U-P.V.C. pipe(All round Concrete)
5401 No 100 Users R.C.C.Septic tank
541Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge.
542Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
543In ground floor
544Supplying all materials, labour, T&P andproviding cement concrete ( 1:3:6) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
545In ground floor
546Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
547In ground floor
548Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
549Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
550Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
551In ground floor
552Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
553In ground floor
554Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
555Supplying all materials, labour, T&P and providing,fitting and fixing 150mm x 150mm x 150mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge
556Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
5571 no 30,000ltr R.C.C. Sump (6.00x2.50x3.00)
558Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge.
559Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in chargewith 1st extra lift of 1.50 m over initial laft.
560Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
561Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge
562Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
563Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge.
564Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,bindingand tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge.
565Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as perspecification and direction of the Engineer-in-charge
566RCC floor, roof slab chhaja up to 4.430 m height
567Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
568Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as perspecification and direction of the Engineer-in-charge
569Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
570Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge
571Construction of 2 Nos. Production tube well by ODEX,Rotary
572Supplying all materials, labour, T&P and Drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plants and consumable etc. for lowering of 200mm/150mm dia G.I/P.V.C./M.S. casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/P.V.C./M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only.
573Drilling for 200mm dia bore
57400mtr to 20 mtr
57521mtr to 43 mtr
576Drilling for 150mm dia bore
57743mtr to above
578Lowering the following size of G.I. / PVC / M.S. housing pipe with or without slotted pipe as per the necessity for ground level upto 45 mtr depth and fitted and fixed up perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plants etc all complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
579Lowering 200mm dia M.S.ERW pipe casing pipe
58000mtr to 43 mtr
581cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge in obtained from the tube well including supply and use of all necessary equipment and labour as per direction of Engineer-in-charge.
582By DTH / Rotary
583Supplying all labour, materials and T&P for providing sanitary sealing by cement concrete grouting of annular space around M.S. casing pipe uptp 5 mtr below groun dlevel to plug the bore hole excluding cost of cement etc all complete as per direction of EIC.
584Cost of cement for sanitary sealing
585Supplying all materials, labour, T&P and providing , fitting and fixing of submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/ 1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with G.I/P.V.C/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc. all complete as per specification and direction of the Engineer in charge.(Texmo/Crompton Greaves/Kirloskar make).
5862HP single phase 3 stage vertical / horizontal submersible pump set at head range 20 to 35 meters discharge 145 to 110 LPM with outlet dia of 25mm
587DOL control panel
58832mm dia steel short piece
589Well cap
59050mm size C.I. Bracket
5912.50 sqmm flat cable
59220mm dia rigid U-PVC pipe
593Steel rope with cover
594Labour charges for lowering including transportation.
595Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes, and pipe fittings confoming toI.S.4985/2000 (10 kgf/sqcm) of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.
59632mm dia HDPE pipes(Finolex/Supreme make)
597RAIN WATER HARVESTING SYSTEM(PIT)(2 nos)
598Earth work in hard soil or gravelly soilwithin 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge.
599Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
600Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
601Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
602Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
603Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
604R.C.C floor and roof slabs, landings, balconies, projecting sunshades and
605Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
606In ground floor
607Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
608In ground floorSlab
609providing and filling filter media
61040mm Boulder-
61120mm washed gravel--
612Course sand-
613Providingfitting& fixing M.S.grill cover over the harvesty pindi
614Sinking of tube well(200) for PIT
615Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
616Drilling of 200mm dia bore
61700 mtr to 25mtr
618Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
619200mm dia PVCpipe
620cost of 200mm pvc pipe
621Cutting slot in casing pipe for recharge of rain water
622labour for packing gravel outside the tube well
623Cost of washed gravel
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail