Tender For Repair Maintenance Of Dg Security Lights Building Lights Servo Stabilizer Vcbs Post Top Lantern Garden Lights And Repair Maintenance Of Water Supply Installation Including Em Infrastructure And Allied Works At Adrde Agra Under Ge I Rnd Del, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance Of Dg Security Lights Building Lights Servo Stabilizer Vcbs Post Top Lantern Garden Lights And Repair Maintenance Of Water Supply Installation Including Em Infrastructure And Allied Works At Adrde Agra Under Ge I Rnd Del. Submission Date for this Tender is 13-05-2024. Tube Light Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43065567
Corrigendum : Tender For Repair Maintenance Of Dg Security Lights Building Lights Servo Stabilizer Vcbs Post Top Lantern Garden Lights And Repair Maintenance Of Water Supply Installation Including Em Infrastructure And Allied Works At Adrde Agra Under Ge I Rnd Del
Open Tender
Indian
Uttar Pradesh
agra
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Maintenance Of Dg Security Lights Building Lights Servo Stabilizer Vcbs Post Top Lantern Garden Lights And Repair Maintenance Of Water Supply Installation Including Em Infrastructure And Allied Works At Adrde Agra Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Apr-2024 corrigendum01 Date 04-05-2024
2 26-Apr-2024 corrigendum02 Date 13-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 48.96 Lakhs /-

Attachment

FileName File Description File Size
bf7b3d8b-6afa-43cb-93d0-b00315ea5f9b.html Tender Notice 0 KB
BOQ_725650.xls Tender Document 0 KB
TDR.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK : REPAIR/MAINTENANCE OF DG, SECURITY LIGHTS, BUILDING LIGHTS, SERVO STABILIZER, VCBS, POST TOP LANTERN, GARDEN LIGHTS AND REPAIR/MAINTENANCE OF WATER SUPPLY INSTALLATION INCLUDING E/M INFRASTRUCTURE AND ALLIED WORKS AT ADRDE AGRA UNDER GE (I) R&D DELHI
Sl. No. Item Description
1Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
2M&L for brick work with modular size full bricksubclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
3M & L for repairing of 300 KVA servo voltage stablizer in following manner Iincluding testing and commissioning with full satisfaction of Engr in Charge- (1)Disconnecting the LT electrical connection from stabilizer and main panel and drain outthe insulating/transformer Oil. (2) Opening of servo stabilizer & taking out the unserviceable core,widing,synchrous motor, variac andCarbon bush and motherboard cards etc refixing the same after cleaning. (3)Rewinding of variac(rehostat) Coil with suitable size of copper conductor as per existing gauge -02 Nos (4) Labour charges for complete repairing and assembling of stabilizer (5) Charges for lifting the variac using suitable size crane. (6) Installing and testing and commissioning after all electrical connection (7) All other minor spares as requiredfor repair the stablizer deened to be included in quoted rate.
4M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 35 KV at 4 mm gap complete all as specified and as directed. Note :- (a) New transformer oil to be bought in company sealed ISI marked container with or original test certificate (b) Filtration /dehydration of transformer oil shall be carried out at the location where servo stabilizer is installed and necessary filter/dehydration plant having pressure gauge, hour meter, temperature gauge to be brought at site by contractor
5Supply and fixing LT panel board indoor type, cubical compartmentpedestal mounting type fabricated CRCA sheet of 2.00 mm thick with both side open type, suitable for 3 phase 4 wire system, 415 volt with insulted Copper bus bar of size suitable to carry 1.5 times current of main MCCB incomershould be provided to length/width of the panel for free and smooth connection of the cable for MCCB, finished with powder coated, dust vermin proof, ventilated compartment door and necessary including arrangement for fixing on wall indoor with the following itemsincluding connection with suitable capacity of copper wire for internal wiring and connecting to LT UG cable using suitable size of lugs and testing and commissioning with foundation, including taking out the old U/S panel board from position and removing from site and make all electrical connection with existing outgoing/incoming cableto the new panel with suitable size lugs complete all as directed:- a)MCCB 125 Amps ,25 kA, TPN415 Volt ,Thermally adjustable - 02Nos( 1 Nos Spare ) b) Copper Bus bar chamber strip size mmsuitable for 250 Amps including insulator , hylem sheet , cable connection etc c) Indicator lamp LED type (RYB) –01 Set. Make- Seimens d) Volt meter Digital type 0-500V with selector switch. One set. e) Amps meter Digital type 0-500 A with CT & selector switch. 01 No. One set Outgoing: a)MCCB 63 Amps ,25 kA, TPN415 Volt ,Thermally adjustable - 05Nos b) star delta starter suitable for 15 HP motors -01 Nos c)MCC DP 32 Amps -01 Nos d)All interconnections between the main bus bar as well as outgoing MCCB shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of outgoing individual MCCB Note :(i)Panel should be manafactured from CPRI approved firm only. (ii) Panel platform should be 1.5 ft hight from ground level (iii) conecting of existing UG cable as per site requirement
6Supply and fixing LT panel board indoor type, cubical compartmentpedestal mounting type fabricated CRCA sheet of 2.00 mm thick with both side open type, suitable for 3 phase 4 wire system, 415 volt with insulted Copper bus bar of size suitable to carry 1.5 times current of main MCCB incomershould be provided to length/width of the panel for free and smooth connection of the cable for MCCB, finished with powder coated, dust vermin proof, ventilated compartment door and necessary including arrangement for fixing on wall indoor with the following itemsincluding connection with suitable capacity of copper wire for internal wiring and connecting to LT UG cable using suitable size of lugs and testing and commissioning with foundation, including taking out the old U/S panel board from position and removing from site and make all electrical connection with existing outgoing/incoming cableto the new panel with suitable size lugs complete all as directed:- Incoming: a)MCCB 125 Amps ,25 kA, TPN415 Volt ,Thermally adjustable - 01Nos b) Copper Bus bar chamber strip size mmsuitable for 250 Amps including insulator , hylem sheet , cable connection etc c) Indicator lamp LED type (RYB) –01 Set. Make- Seimens d) Volt meter Digital type 0-500V with selector switch. One set. e) Amps meter Digital type 0-500 A with CT & selector switch. 01 No. One set Outgoing: a)MCCB 63 Amps ,25 kA, TPN415 Volt ,Thermally adjustable - 5Nos b)MCC DP 32 Amps -01 Nos c)All interconnections between the main bus bar as well as outgoing MCCB shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of outgoing individual MCCB Note :(i)Panel should be manafactured from CPRI approved firm only. (ii) Panel platform should be 1.5 ft hight from ground level (iii) conecting of existing UG cable as per site requirement
7M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and RCC cover of size54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in drawingNote - Cost of GI stripand GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items.
8M&L in repair for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
9M&L for moorum filling floors or pavings laid in layers n exc 15 cm thick ,spread, levelled, and blind earth and rammed in cluding watering all as specified and directed by Engr -In- Charge.
10Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and getting out in soft/loose Soil complete all as specified and directed.
11S&F in repair Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
12S&F in repair Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
13M&L for Painting of steel surfaceof any description, over 10cm in width or girth apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
14S&F 3 mm dia galvanised steel wire chain link fencing(wire mesh size100x100mm)incl line wire (stiffness 10 mm MS round bar/tor bar) 3 Nos horizontally all as specified and directed
15S&F in repair joist, chanel, MS pipe, angle or tee sections as in post and structs in fencing incl cutting of to shape as directed drilling holes knotching for wire etc, flat iron fillete (for securing wire mesh/chain-link fencing etc) incl all necessary drilling, riveting,nut bolt etc and similar work confirming to Gde-Fe-410-0 or Fe-310-0.
16Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
17Taking down cement/ lime plaster of any description on brick work or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as spfd directed.
18M&L for 15mm thick plaster on surfaces of brick work or stone walling in CM 1:6 finishingthe surface even & fair complete all as spfd and directed.
19M&L for valve chamber of size 1500mm x 1500mm x 860mm (internal dimention) with brick masonty valve chamber, 100mm thich PCC (1:4:8) type D2 as in foundation, 200mm thick brick wall built in CM (1:6), 50mm thich coping of PCC (1:3:6) type C1, 15mm thick plastering in CM (1:4) to all internal and exposed surface including necessary excavation and earth work in soft/loose soil, MS sheet cover 6mm thickness along with angle iron frame of size 40 x 40 x 5mm with locking arrangement with necessary fixing materials like hinges, nut bolts etc (valve chamber cover shall be opened in two valves) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc with and including dismantling and taking out existing damaged/ rusted valve pit cover of any size from valve pit chamber complete all as specified and directed.
20Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
21M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick CM 1:4 for laying floor finishescomplete all as specified and directed.
22S&F in repair angle iron frame work as in sign board using GI pipe,MS plates,nut,bolts etc including welding and painting using two coats of blue colour over a coat of red oxide primarcomplete all as specified and directed.
23M&L forwritingletters or figures onrising /distribution/overflow pipe of any sizefor OH tank, glow sign board,pannel , transformer ,wall etc with one coat ofsynthetic black enameled paintafter neccessaery preparation of surfaces completesame colouras per existing complete all as specified and directed .
24M&L for preparing old decorated plastered or unplastered surface of wall by brooming down or steel wire brushing ,scrapping down smoke soot ,moulds,moss and efforescent salts and trading oil and greasy spot and applying one coat of white wash complete all as specified and directed.
25M&L for preparing old decorated plastered or unplastered surface of wall by brooming down or steel wire brushing ,scrapping down smoke soot ,moulds,moss and efforescent salts and trading oil and greasy spot and applying one coat of colourwash was complete all as specified and directed.
26Dismantling and taking down unserviceable street light / security light fitting/bulkhead light/garden light/bollard light of 30/45/48/60/70/90/120 watt from existing Bldgor Street light pole after disconnecting all electrical connections andreplacement ofthe sameand including all electrical connections complete all as specified and directed.
27Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 including mounting bracket of 1.5 mtr GI pipe light grade bended at 120 degree in 1:2 ratio, protectioncomplete all as specified and directed.
28Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 including mounting bracket , protection 70/150/250 watt complete all as specified and directed.
29Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 including mounting bracket of 1.5 mtr GI pipe light grade bended at 120 degree in 1:2 ratio, protection 70/150/250 watt complete all as specified and directed.
30Supply and fixing post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampincluding taking down old conventional post top light fitting 40/60 watt, complete all as specified and directed by Engr-in-Charge.
31S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmmas current carrying conductor and one run of 2.5 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and includingPVC conduit ISI marked of dia not less than 25 mm with standard accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 2.5 sqmm all as specified and directedincluding taking down old unserviceable complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
32S& F forcast iron /pressed steel terminalrectangular box 60mm deep and 150x75 mm of size for mounting switches,sockets ,regulator etc. with 3mm thick plastic laminated sheet cover of size rectangular complete including taking down old one.
33S&F in repairswitch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old unserviceable complete all as specified and directed.
34S & Fceiling rose, surface Bakelite,isolated bodythree terminals including taking down old unserviceable complete all as specified and directed..
35S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used singlepole and neutral 4 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing specified and directedincluding taking down old unserviceable complete all as specified and directed.
36S&F MCB’s single pole and neutal,32 Amp to 40 Amp 240 Volts,and of ""B"" series with required wiring connections and lugs etcincluding taking down old unserviceable complete all as specified and directed.
37Supplying, laying, jointing & testing, in replacementof 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,4 Core 25 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole orunder floor /roador laid in trenches including taking out old unserviceable cable complete all as specified and as directed.
38Supplying, laying, jointing & testing, in replacementof 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,2 Core, 10 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole orunder floor /roador laid in trenches including taking out old unserviceable cable complete all as specified and as directed.
39Supply and spread clean dry sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I complete all as specified and as directed. Note :-Punned thickness os sand shall be measuired & paid.
40M&L for brick, subclass "B" well burnt, laid dry flatin trenches for protection of cable with a maximum gap of 10 mm between two consecutive brick over LT cable, complete all as specified and as directed.
41Excavation in trenches not exceeding 1.5 min deep & not exceeding 1.5 mwideand getting out in soft / loose soil including leveling and ramming complete all as specified and as directed.
42Excavation in trenchesexceeding 1.5 min deep & not exceeding 3 mwideand getting out in soft / loose soil including leveling and ramming complete all as specified and as directed.
43Returning, refilling in trenches exvcavated soils, including spreading leveling & well ramming in layers not exceeding 25 cmthick complete all as specified and directed.
44Removal of excavated surplus soil to a distance n.exceeding50 m and depositing where directed at a level not exceeding1.5 metre above the starting point complete all as specified and directed.
45Maintenance /repair of DG set of capacity 400/40/20 KVA on every month including checking, cleaning, adjusting/tightening, oiling, greasing and reseting of existing part decarbonising of battery terminals of DG set at different location of installation and keep ready to set for proper functioning of valve "V" belts pulleys, fan hub, idler, water pump, fiters engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, springs, AVRs exhause pipes etc of following capacity of DG sets :- Note : 1.Spares part will be measured and paid separetely under respective item of BOQ/ Sch "A" 2. Each DG set repared per month shall be considered as Each Job. 3.If any DG Set has to be reparred once a month, the rates are deemed to be included in qouted rates..
46Disconnecting connection of radiator and taking down for servicing and cleaning and refix the same complete all as specified and directed.
47Supply only Air Filter suitable for 400 KVA DG Set.
48Supply only Oil Filter suitable for 400 KVA DG Set.
49Supply only diesel filter suitable for 400 KVA DG Set
50Supply only Water separator suitable for 400 KVA DG
51Supply only Air Filter suitable for 20/40 KVA DG Set.
52Supply only Oil Filter suitable for 20/40 KVA DG Set.
53Supply only deisel filter suitable for 20/40 KVA DG Set
54Supply only Coolant complete all as specified and directed.
55Supply only Engine oil complete all as specified and directed.
56Taking out old unserviciable battery from DG Set including supply, fixing and testing of maint free battary 12 Volts 180 AH complete all as specified and directed. Make : Exide, Amaron, luminous, Amara Raja.
57Taking down old unserviciable Automatic voltage regulator from DG Set and supply, fixing including testing of new Automatic voltage regulator suitable DG Sets of capacity 400 KVA complete all as specified and directed.
58Taking down old unserviciable Automatic voltage regulator from DG Set and supply, fixing including testing of new Automatic voltage regulator suitable DG Sets of capacity 40/20 KVA complete all as specified and directed.
59S&F in replacement flexible rubber coupling of engine and alternater with bolts and nuts etc of suitable size for 400 KVA capacity complete all as specified and directed.
60Taking out FIP from DG set for 400 KVA Capacity and transporting up to nearest workshop for calibration including calibration of FIP from authorised workshop, transporting back, refixing the same in DG Set including testing for smoth functioning complete all as specified and directed.
61Taking out FIP from DG set for 40/20 KVA capacity and transporting up to nearest workshop for calibration including calibration of FIP from auth workshop, transporting back, refixing the same in DG Set including testing for smoth functioning complete all as specified and directed.
62Supply and erecting in true vertical position steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate pole cap,finial taper plug,bolts, nuts, washersetc including painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking out old unserviceable pole complete all as specified and directed. Note: (i)The portion above coping shall be painted in alternative bands of black & white colours starting with black colour (each band of 30 Cm wide) by two coats of Synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the rate quoted. (ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the rate quoted. (iii) PCC and and exavation shall be measured and paid seperately. (iv)The rates alsoincludedrilling of holesinsteel tubular poles for continuous G.I. earth wire etc. to the required size and number.
63Supply and erecting in true vertical position steel tubular swan necked 9 mtr long complete with CI base plate pole cap,finial taper plug,bolts, nuts, washersetc including painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed. Note: (i)The portion above coping shall be painted in alternative bands of black & white colours starting with black colour (each band of 30 Cm wide) by two coats of Synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the rate quoted. (ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the rate quoted. (iii) PCC and and exavation shall be measured and paid seperately. (iv)The rates alsoincludedrilling of holesinsteel tubular poles for continuous G.I. earth wire etc. to the required size and number.
64M& L in replacement for fixingjunction boxmade of plastic material of size 239X328X129 mm withopaque cover ,conical cable gland aluminium lugs, Protection Class IP 65,04 nos aluminium bus bar of size 25x3 mm for three phase and neutral including 01 nos 06 Amps MCB SP for controlling street light and2 Nos MS clamp of size 30x5 mm complete with nut, bolt and washers for mounting the junction box on street light pole complete all as specified and directed Make: SINTEX RAL7035 SIL-EV322 or equivalent as approved by GE.
65M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in flooring on existing sub base surfaces of OH tank,pump houses finished cement concrete surface even and smooth without using extra cement including necessary form work and concrete (PCC) to be cast in alternate bays including demolition of old PCC complete all as specified and directed.
66M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in pole foundation including necessary form work and concrete (PCC) to be cast in alternate bays including demolition of old PCC complete all as specified and directed.
67M&L for GI pipe (light grade) with all fittings laid in trenches/wall/floors complete for protection UG cable when crossing the road for fixing post top lentern of size 40 mm bore complete all as specified and directed.
68M&L for boring of holes by manually / machine under road, pavement, hard standing by trenches for laying of 40 mm GI pipe for cable laying, complete all as specified and directed..
69Supply & fixing PVC insulated aluminium conductor 2.5 Sqmm 2 Core cable with 1x2.5 sqmm PVC instulated aluminium conductor asearth wire for service connection of street light from junction box of LTelectric pole complete all as specified and directed.
70Supply installation testing and commissioning of street lightpanel three phase suitable for max load of 5 KW with natureswitch sensor and hensel enclosure conforming to IP 66,25 amp per phase MCB suitable and including mounting on wall/pole for control street light/aviation light including connections with the cable gland aluminium lug, MS FIixing clamp ,cutting the hole in wall of suitable size including taking out the old main panel complete all as specified and directed. Make - SWADEEP-66-5KW3P or equivalent as approved by GE.
71Supply installation testing and commissioning of street lightpanel single phase suitable for max load of 3 KW with natureswitch sensor and hensel enclosure conforming to IP 66,25 amp MCB suitable and including mounting on wall/pole for control street light/aviation light including connections with the cable gland aluminium lug, MS FIixing clamp ,cutting the hole in wall of suitable size including taking out the old main panel complete all as specified and directed. Make - SWADEEP-66-3KW1P or equivalent as approved by GE.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail