Tender For Repair / Maintenance Of External Electric System, Lt Panels And Other Connected Works At Karcham And Poari In The Area Of Age E/M (We) Pooh Under Ge 863 Ews, karcham-Himachal Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance Of External Electric System, Lt Panels And Other Connected Works At Karcham And Poari In The Area Of Age E/M (We) Pooh Under Ge 863 Ews. Submission Date for this Tender is 19-04-2024. Electrical Panel Tenders in karcham Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43065560
Corrigendum : Tender For Repair / Maintenance Of External Electric System, Lt Panels And Other Connected Works At Karcham And Poari In The Area Of Age E/M (We) Pooh Under Ge 863 Ews
Open Tender
Indian
Himachal Pradesh
karcham
19-04-2024

Tender Details

Tender For Repair / Maintenance Of External Electric System, Lt Panels And Other Connected Works At Karcham And Poari In The Area Of Age E/M (We) Pooh Under Ge 863 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Apr-2024 Tender Date Postpone Date 19-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work : REPAIR / MAINTENANCE OF EXTERNAL ELECTRIC SYSTEM, LT PANELS AND OTHER CONNECTED WORKS AT KARCHAM AND POARI IN THE AREA OF AGE E/M (WE) POOH UNDER GE 863 EWS
Sl. No. Item Description
1Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles, complete, all as specified and directed
2Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm thick each layerin hard/dense soil,complete, all as specified and directed
3Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point, complete, all as specified and directed
4M & L for Sand cushioning on under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable, complete, all as specified and directed
5Supply and lay well burntclass ‘B’ bricks as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete, all as specified and directed
6Supply and laying in replacement ofGI pipe light grade 80mm bore, galvanizedwith all fittings laid in trenches for cable protection , complete, all as specified and directed
7Supply and laying in replacement ofGI pipe light grade 50mm bore, galvanizedwith all fittings laid in trenches for cable protection , complete, all as specified and directed
8Taking out faulty U/G cable of any size by removing PCC covers or bricks of any specification for replacingthe same withnewLT U/G cable, complete, all specified and as directed
9Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 120 sqmm ,3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
10Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 95 sqmm ,3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
11Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 50 sqmm ,3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
12Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 35 sqmm ,3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
13Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 25 sqmm ,04 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
14Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 16 sqmm ,04 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
15Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 10 sqmm ,02 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
16Supplying, laying in trenches /passing throughtubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts gradeXLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 06 sqmm ,02 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
17M&L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with topedge of the plate not less than 1.5m below normal ground level connected to GI earth strip25x4 mm dia up to 7.5 meter from earth pit, protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel , common salt, charcoal dust and connected to panel board by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I includingnecessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed.
18Supply, fix in replacement of MCCB, 400 Amps, 4 Pole, 415 V, Adjustable type with breaking capacity 36 KA with spreader links,etc complete all as specified and directed.
19Supply, fix in replacement of On load Change over100 Amps, 4 Pole 415 V,etc complete all as specified and directed
20Supply, fix in replacement of MCCB, 250 Amps, 4 Pole, 415 V, Adjustable type with breaking capacity 36 KA with spreader links,etc complete all as specified and directed.
21Supply, fix in replacement of MCCB, 200 Amps, 4 Pole, 415 V, Adjustable type with breaking capacity 36 KA with spreader links,etc complete all as specified and directed.
22Supply, fix and testing in replacement of MCCB 160 Amps, 4 Pole 415 V, Adjustable type with breaking capacity 25 KA with spreader links,etc complete, all as specified and directed.
23Supply, fix and testing in replacement of MCCB 100 Amps, 4 Pole 415 V, Fixed type with breaking capacity 25 KA with spreader links,etc complete, all as specified and directed.
24Supply, fix and testing in replacement of MCCB 63 Amps, 4 Pole 415 V, Fixed type with breaking capacity 16 KA with spreader links,etc complete, all as specified and directed.
25Supply and errection in replacement of steel tubular swaged pole ,09 M long, type 410-SP-31, complete with CI base plate, finial taper plug, bolts, nuts and screws etc including, complete, all as specified and directedNote : Necessary excavation and earth work, PCC foundation, coping, disposal of surplus soil, Painting inside with black bitumen paint and out side shall be measured and paid separately on relevant items of Sch "A"
26Restringing only ACSR conductor of any type/ size on existing LT poles, etc including binding on to insulators with and including aluminium wire, complete, all as specified and directed .
27M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts, washers, welding , bending cold or hot or hot drilling holes for bolts, washers in any shape or size as indicated or directed incl one primer coat, one under coat & one finishing coat, complete, all as specified and directed
28Supply, fixing and stringing in replacement of ACSR conductor of any type/ size on existing LT poles, etc including binding on to insulators with and including aluminium wire, complete, all as specified and directed.
29S & F in replacement of pin type, porcelain vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65mm dia for 1100 Volts grade, complete, all as specified and directed.
30S & F in replacement of shackletype porecelain vitreous white brown or green insulator for working pressure 1100 volts of 90mm dia and 75mm height incl galvanised steel straps of 31x3 mm size, insulator bolt 12 mm dia,washer & nuts, complete, all as specified and directed.
31S & F in replacement of PVC line phase separators for over headline LT conductor of any size suitable to withstand 1100 volts to maintain the required spacing between 5 conductors, complete, all as per site requirement and all asdirected
32S & F in replacement of Stay assembly Diameter ofstay rod of not less than 20 mm, 215cm long with threaded end with suitable size of nuts & washers complete with accessories including staybowswith nut bolt & washer of 14mm dia, 40cm long and stay grips & thimble of suitable sizeas shown in electrical plate No. 1 SSR Part-I, complete, all as specified and directed. Note:(i) Rate are deemed to be inclusive of streching, tieing and tightening of stay assembly for poles including tieing frame for stay wire. (ii) Exacavation, returning filling, removal for stay wire assembly upto 2.5 mtrs including Ropes are deemed to be included in quoted rates. (iii) Ladders of any size,T&P (any type), Labour Safety equipments as required at site for working on PCC pole of 9Mtrs height is deemed to be inclusive of quoted rates. (iv) Stay clamp/stay wire will be measured & paid saperately.
33M&L in replacement Loop type insulator, vitreous porcelain, white, brown or green of Large size, with overall dimensions 140mm, clearance of hole 25.5mm, including nut bolts & washers of suitable length and thickness, complete, all as specified and directed.
34M&L in repair galvanised stay wire 7/4mm for stay assembly to be fixed between stay assembly and stay clamp on PCC/MS steel pole, complete, all as specified and directed.
35M & L for Plain cement concrete (1:2:4) type B1 using 20mm well graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary,complete, all as specified and directed.
36M & L for PCC 1:3:6type C2 (using 40mm well graded stone aggregate) in foundation, filling and mass concrete,complete, all as specified and directed.
37M & L for Aluminium paintingto Steel tubular Street light pole for 5.5 mtr from top towards bottomand next 0.45 mtr Navy Blue and next 1.10 mtr white and 0.45 mtr Synthetic enameld paint yellow & black colour(Tiger cross) on Coping and writing pole No with white paint inside of black circle above the Navy blue painting and aluminium painting to GI bracket / pipe etc.and sticking of reflector stricker red in colour on the Poles at the height of 1.5metre above the copping, complete, all as specified and as directed.
38Supply and fixing in replacement ofBusbar chamber 100 Amp with suitable thickness aluminium busbars, 4 way, 415 volts, 50 Hz, Wall mounted type incliuding suitable fastners, etc complete all as specified and directedMake : Indoasian/Havells/L&T/Standard
39M&L for taking proper shut down and servicing the LT panel board of any type ( indoor/Out door) make complete with removal of dust reconnection of all incoming and outgoing cable with proper gland replacemnet of all nut, bolts and washers, repalcement of control wiring including insulation tapping with colour coding replacement of burned aluminium bus bars, fixing of LT panel front and back door covers on hinges complete with cutting, welding, grinding etc and providing porper locking arrangements etc all as speciified and directed by Engineer in - charge. Note : (a)Cost for replacement of minorspares like thimble, porcelain unsulator, busbar sleeve, cable sleeve, etc are deemed to be included in the quoted rates. (b)The rates shall be deemed to be included for replacement of worn out rusted, Channels, hinges, bolts, split pins and cable lugs, cable glands and neoprene gasket to all doors including raising of foundation to 300cmheight etc.
40M&L for Painting LT panel of any type or size with two coats ofsynthetic enamelled grey paintwith brush of suitable size including preparation of old painted surface after taking shut down of that panel complete all as specified and as directed.
41M&L for any type of road cutting upto 300mm deep & 300mm wide for laying GI pipe for protection cable complete all as specified and as directed.
42Net Contract Sum will be after deducting Sch Of Credit of Rs.74108.75.00