Tender For Replacement/ Repair/ Conversion Of Lt Overhead Line Into Under Ground System Of Electric Supply And Connected Accessories Of Electric Supply Under Ge Clement Town, Dehradun, Dehradun-Uttarakhand

Military Engineer Services-MES has published Tender For Replacement/ Repair/ Conversion Of Lt Overhead Line Into Under Ground System Of Electric Supply And Connected Accessories Of Electric Supply Under Ge Clement Town, Dehradun. Submission Date for this Tender is 08-05-2024. Overhead Line Tenders in Dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

43063914
Corrigendum : Tender For Replacement/ Repair/ Conversion Of Lt Overhead Line Into Under Ground System Of Electric Supply And Connected Accessories Of Electric Supply Under Ge Clement Town, Dehradun
Open Tender
Indian
Uttarakhand
Dehradun
08-05-2024

Tender Details

Replacement/ Repair/ Conversion Of Lt Overhead Line Into Under Ground System Of Electric Supply And Connected Accessories Of Electric Supply Under Ge Clement Town, Dehradun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work:REPLACEMENT/ REPAIR/ CONVERSION OF LT OVERHEAD LINE INTO UNDER GROUND SYSTEM OF ELECTRIC SUPPLY AND CONNECTED ACCESSORIES OF ELECTRIC SUPPLY UNDER GE CLEMENT TOWN, DEHRADUN.
Sl. No. Item Description
1M & L for dismantlingUNSV/rusted cross arms of MS channel or angle/flat iron sections, nuts bolts etc from LT poles complete all as specified and as directed.
2M & L forDismantling Old UNSV insulators any type and size from RCC/PCC poles complete of 9 mtr long from ground level complete all as specified and as directed.
3Distmantling Old UNSV/rusted stay assembly set somplete demolition of concrete etc complete all as specified and as directed.
4M & L for dismantling of Old UNSV ACSR or AAC conductor or jumpers from pole/ LT over head line of 9 mtr long pole from ground level complete all as specified and as directed.
5M & L for dismantling of old UNSV/broken house service bracket of any type and size from CGI sheet roof of maximum 5 mtr from ground level all as specified and making good the distrubed surface complete all as specified and as directed.
6Dismantling & Removing carefully Old unserviceble LT cables/ Service cable of size 16 sqmm to 35 sqmm ( 2/3/3.5/4 core ) from LT Pole to MCB DB complete all as specified and as directed.
7Dismantling of steel poles/struts any size complete and transporting to store yard complete all as specified and as directed.
8Supplying, laying, jointing testing and connecting in replacenentofXLPE insulated, screened, PVCbedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors,IS 7098marked, suitable for LT 1100 Voltsystem, laid in trenchesfixed to pole, including jointing & testing complete all as specified and directed of following sizes complete all as specified and as directed. Note :-Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
9Cross sectional area 16 sqmm 4 Core
10Cross sectional area 35 sqmm 3.5 Core
11Cross sectional area 50 sqmm 3.5 Core
12Cross sectional area 70 sqmm 3.5 Core
13Cross sectional area 95 sqmm 3.5 Core
14Cross sectional area 120 sqmm 3.5 Core
15Excavation in trenches soft/loosesoil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depthfor foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10 sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed.
16Excavation in trenches soft/loosesoil not exceeding 1.5 mtr wide in exceeding 1.5mtr in depthfor foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10 sqmm on plan and not exceeding 3mtr in depth and getting out complete all as specified and as directed.
17Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
18Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed.
19M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and as directed.
20Supplying and layingcommon burnt bricks, clay building, sub class "B" desingation 75 in trenches for cable protection complete all as specified and as directed.
21M & L for plastic emulsion painting with two coaton concrete/ plaster sufraces (Pole coping) of any description over 10 Cm girth or width complete all as specified and as directed.
22M/L for HDPE pipe suitable for 5/6 kgf/cm square working pressurewith all fitting , laid in trenchesfor protection of cable in road /drain crossing complete all as specified and as directed of following sizes :-
2332 mm dia
2463 mm dia
2590 mm dia
26110 mm dia
27M & L for supply, erection and commissioning ofsteel tubular swaged poles with top mounted bracket complete with cast iron base plate, finial taper plug, bolts, nuts and screwes as specified type LT type 410 SP-22, (8.5m long)including placing at new location complete withexcavation, earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation and coping of poles with PCC 1:3:6 type C1 (using 20mm graded stone aggregate) complete all as specified and as directed. (Note :- Excavation, earth work and concrete work complete not included in unit item of the rate quoted by the Contractor nd the same will be paid seperately).
28Dismantling and taking down carefully old bracket from the existing 9 mtr long LT swaged pole,M & L for necessary aluminium paint of two coat and fixingthe same on new pole pole at another location complete all as specified and as directed.
29Dismantling and taking down old serviceable LED street light fitting of any wattage, necessary cleaning/servicing and M & L for fixing the same on newLT swaged pole 9 mtr long complete making necessary connection complete all as specified and as directed.
30Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
31M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directlyin ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including GI Strip of size 25x4 mm and light grade protection pipeof 40 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valuecomplete including testing on completion all as specified and directed. (GI strip upto 7.5m including testing consider in this item).
32M&L for Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) or any description and any positioncomplete all as specified and as directed.
33Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling for poles complete all as specified and as directed.
34Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and as directed.
35M & L for MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and as directed.
36Supply, installing, testing and commissioning LT Outdoor floor mounted Panel board, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 1200X1200X500 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus barsinstalled on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54)in accordance with IS-2147. b) and made of 3.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 50 mm x 50 mmx 6 mm thick and 900 mm long), front & rearopening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrumen chamber with digital Voltmeter and Ammeter of suitable rating as per the Incoming MCCB/load rating with selector switch and RYB indicator LED lamps. The scope of work also comprising of the following:- (A) Aluminium Bus bar chamber rating :300 Amps, TPN, 415V (B) Incoming MCCB rating : 250 Amps, 4P, 36 KA - 01(C)Outgoing MCCBs rating :100 Amps, 4P, 25 KA - 02 (D) Outgoing MCCBs rating : 63 Amps, 4P, 25KA - 02(E) Outgoing MCB SPN 32 Amps, 10 KA : 01 NOTE : (i) All the MCCB with Rotary Mechanism Handle and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Panel wiring for control circuit with copper flexible 1.5 Sq mm& powerwiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box. (iii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor. (iv) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
37Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 900X900X500 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus barsinstalled on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54)in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 50 mm x 50 mmx 6 mm thick and 900 mm long), front & rearopening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrumen chamber withRYB indicator LED lamps. The scope of work also comprising of the following:- (A) Aluminium Bus bar chamber rating :2x100 Amps (Double bus bar), TPN, 415V (B) Incoming MCCB rating : 125 Amps, 4P, 25 KA - 01(C)Outgoing MCCBs rating :100 Amps, 4P, 25 KA - 02 NOTE :(i) Panel wiring for control circuit with copper flexible 1.5 Sq mm& powerwiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors.(ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor.(iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
38Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 750X750X300 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus barsinstalled on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54)in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mmx 5mm thick and 450 mm long), front & rearopening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrumen chamber withRYB indicator LED lamps. The scope of work also comprising of the following:- (A) Aluminium Bus bar chamber rating :100 Amps, TPN, 415V (B) Incoming MCCB rating : 63 Amps, 4P, 10 KA - 01 NOTE :(i)Panel wiring for control circuit with copper flexible 1.5 Sq mm& powerwiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in uit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
39Supply and fixing Polycabonate fabricated, outdoor type, cubical, sloping canopy top roof, pole mounted, hinged single door with locking arrangement, front side openable box suitable for three pahse, 415 volts, AC supply with 04 Nos Aluminium bus bar rating 32 amps(R.N) with one NoMCB 06 Amps, SP having size 250x200x120 mm complete including making fixing arrangement with LT poleswaged type with flat iron clamp complete all as specified and as directed.
40Supplying and fixing 1100 Volts grade heavy dutycable PVC insulated copper conductor FR roundflexible in street light connection from pole junction box at bottom to street light fixed on LT pole swaged type by making two holes with welding machine for inserting cable of 8.5/9 mtr long swaged polecable of size 1.0 Sqmm 3 core multistranded including making all necessary connection complete all as specified and as directed.
41Supply, fabricated and and fixing of street light bracket made out of GI pipe 1.2 Mtr long, 32mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer complete all as specified and as directed.
42Boaring holes horizontally under Road/Path/Pavement/drain or any other situation by mannual meanswithout damaging the surface of road (minimum 1.0 Mtr bellow the road surface) suitable for passing of HDPE pipe 63 to 90 mm bore and making good both ends complete all as specified and as directed. (HDPE pipe of 63 to 90 mm bore laid in boring section shall be measured and paid seperately)
43Supply and fix cable jointing kit on existing underground laid cablefor 1.1 KV grade cable for straight through joint Tubular sleeve version, complete with jointing materialand accessories suitable forXLPE, armoured, Aluminium conductor cable followingsizes complete. (Note- Rate quoted is deemed to be included for Cable jointing with existing serviceable UG cable laid under trench and providing new UG cable of approprite size upto LT feeder pillar boxand necessary testing.(ii) New cable of any size from straight throught joint to feeder pillar box will be measured and paid seperately under relevant items of schedule)
44Cable size 10-16 Sqmm 2 Core
45Cable size 10-16 Sqmm 3.5/4 Core
46Cable size 25-50 Sqmm 3.5/4 Core
47Cable size 70-150 Sqmm 3.5/4 Core
48M & L for taking down old serviceable street light bracket fixed on pole of 9 mtr long at any height, removing all MS work/GI pipes of any dia andpreparation of old painted surface of steel tubuler pole of 9 mtr long swaged pole by removing all dirt, dust, corrosion etc and apply two coats of aluminium paint on steel surface of complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on pole including black and yellow strips with two coats of synthetic enamel painting upto 1.5 metre height and writing of identification Nos,etc and re-fixing the street light bracket with street light fitting ofany wattage and testing complete all as specified and as directed. Note- (i) Taking out allold MS work & making good to steel tubular pole if any required at site is deemed to be included in quoted rate.(ii) Taking down old serviceable street light with bracket and refixing the same at a height 7.0 meter from the ground level is also deemed to be included in quoted rate).
49NOTES :- 1.For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Disclaimer :