Tender For Replacement And Maintenance Of Lt Feeder Pillar Boxes, Ug Cables, Earthings And Allied Electrical Works Under Ge Clement Town, Dehradun-Uttarakhand

Military Engineer Services-MES has published Tender For Replacement And Maintenance Of Lt Feeder Pillar Boxes, Ug Cables, Earthings And Allied Electrical Works Under Ge Clement Town. Submission Date for this Tender is 15-05-2024. Electrical Maintenance Tenders in Dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

43063726
Corrigendum : Tender For Replacement And Maintenance Of Lt Feeder Pillar Boxes, Ug Cables, Earthings And Allied Electrical Works Under Ge Clement Town
Open Tender
Indian
Uttarakhand
Dehradun
15-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Replacement And Maintenance Of Lt Feeder Pillar Boxes, Ug Cables, Earthings And Allied Electrical Works Under Ge Clement Town

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Apr-2024 Date Extnd Date 08-05-2024
2 27-Apr-2024 AmendBOQ BOQ 08-05-2024
3 08-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
6ad120fe-8363-4c4e-8f3c-065563b7e5ce.html Tender Notice 0 KB
BOQ_725750.xls Tender Document 0 KB
Tender8148.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:REPLACEMENT AND MAINTENANCE OF LT FEEDER PILLAR BOXES, UG CABLES, EARTHINGS AND ALLIED ELECTRICAL WORKS UNDER GE CLEMENT TOWN.
Sl. No. Item Description
1Taking down old U/S LT Panel/Feeder Piller Box/ Busbar Chamberexcluding serviceable MCCB"s complete all as specified and directed. (Note: serviceable MCCB"s of any cap shold be deposited in MES store yard)
2M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of old steel surface over 10cm width or girth, spray painting of approved quality / Shade including preparation of existing old painted surfaceof feeder pillar box/LT panel/any steelor iron surface as directed by Engr-in-charge of any description and indoor/outdoor type complete all as specified and directed.
3Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 1000X1000X500 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus barsinstalled on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54)in accordance with IS-2147 and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 50 mm x 50 mmx 6 mm thick and 900 mm long), front & rearopening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrumen chamber withRYB indicator LED lamps. The scope of work also comprising of the following:-(A) Aluminium Bus bar chamber rating :2x250 Amps (Double bus bar), TPN, 415V (B) Incoming MCCB rating : 160 Amps, 4P, 25 KA - 01(C)Outgoing MCCBs rating :100 Amps, 4P, 25 KA - 02 Nos NOTE :(i) Panel wiring for control circuit with copper flexible 1.5 Sq mm& powerwiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors.(ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor.(iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
4Supplying, laying, jointing testing and connecting in replacementofXLPE insulated, screened, PVCbedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) of cross sectional area 16 sqmm 4 Core with multistranded aluminum conductors,IS 7098marked, suitable for LT 1100 Voltsystem, laid in trenches,fixed to pole, including jointing & testing including taking out old UNSV cable of any size complete all as specified and directed. Note :-Excavation, earth work ,cable protection, sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
5All as per item No.04 above but25 Sqmm 3.5 core.
6All as per item No.04 above but35 Sqmm 3.5 core.
7All as per item No.04above but 50 Sqmm 3.5 core.
8All as per item No.04above but 70 Sqmm 3.5 core.
9All as per item No.04above but 95 Sqmm 3.5 core.
10All as per item No.04above but 120 Sqmm 3.5 core.
11All as per item No.04above but 240 Sqmm 3.5 core.
12Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
13Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
14Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
15M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thickness of sand will be measured and paid.
16Supply and laying , un-reinforced precast concrete cable cover ,class LV,Type I,flat,size 250mmX150mmX40mm with breaking load capacity 200 Kg complete all as specified and directed.
17Supply and laying in replacement GI tube light grade in trenches/wall for Cable Protection of 100 mm dia in size including all required fittings complete all as specified and directed.
18Supply and laying in replacement GI tube light grade in trenches/wall for Cable Protection of 80 mm dia in size including all required fittings complete all as specified and directed.
19Supply and laying in replacement GI tube light grade in trenches/wall for Cable Protection of 50 mm dia in size including all required fittings complete all as specified and directed.
20Supply and laying in replacement GI tube light grade in trenches/wall for Cable Protection of 40 mm dia in size including all required fittings complete all as specified and directed.
21Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1400X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.15mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -a)Busbarchamber :Electrically grade Aluminiumbus bar of capacity 500 Amps for each phase andNeutral , fixed on DMC insulators and provision of extension. Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work-INCOMER :(i) MCCB 350Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set.(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three). (vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set.Outgoing:Outgoing with one compartment each comparment witll consist the following :(i) MCCB 100 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 04 Nos(ii)MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 03 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos
22Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1200X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -a)Busbarchamber :Electrically aluminium bus bar of capacity 400 Amps for each phase and 400 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension. Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work- INCOMER :(i) MCCB 250Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set.(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three). (vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. Outgoing:Outgoing with one compartment each comparment witll consist the following :(i) MCCB 100 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 03 Nos(ii)MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos
23Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1800X1300X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -(a)Busbarchamber :Electrically grade aluminiumbus bar of capacity 600 Amps for each phase and 300 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension. Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work- INCOMER :(i) MCCB 400Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set.(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three). (vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. Outgoing:Outgoing with one compartment each comparment witll consist the following :(i) MCCB 125 amps, 415Volts, 4 pole 50 Hz, 35 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos(ii)MCCB 100 amps, 415Volts, 4 pole 50 Hz, 25 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 04 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos
24Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1400X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -(a)Busbarchamber :Electrically grade aluminium bus bar of capacity 500 Amps for each phase and 250 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension.Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work- INCOMER :(i) MCCB 320Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set.(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three). (vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. Outgoing:Outgoing with one compartment each comparment witll consist the following :(i) MCCB 125 amps, 415Volts, 4 pole 50 Hz, 25 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 01 Nos(ii) MCCB 100 amps, 415Volts, 4 pole 50 Hz, 16KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos (iii) MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 03 Nos (iv) MCB SP 20 Amps10 KA- 01 Nos
25Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1400X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -(a)Busbarchamber :Electrically grade aluminium bus bar of capacity 400 Amps for each phase and 200 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension.Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work- INCOMER :(i) MCCB 250Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set.(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three). (vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. Outgoing:Outgoing with one compartment each comparment witll consist the following : (i) MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 06 Nos (iv) MCB SP20 Amps10 KA- 01 Nos
26Notes for Item No 21 to 25 :- 1. Panel manufacturers should have in house powder coating plant with minimum 8 tank pretreatment of MS sheet facilities, dust free spray paint booth.(8 tanks pretreatment process includes: degreasing/water rinsing/de-dusting/water rinsing/activation/phosphating water rinsing/passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel 3. The panel manufacturer should have following certification: (i) CPRI certification degree of protection IP-54 ( should have IEC:61439-1-2 & IEC:60529 tests) (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA (iii) CPRI certification rated current for short circuit not less than 5000A 4. All the electricals switch gear like MCCBs, MCB should be of same make 5. Drawing of panel board should be got approved from GE before fabrication. 6. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
27Supply, fixing and testing MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete with all connected accessories including taking out old UNSV MCCB from the existing panel after disconnecting all incoming and out going UG cable cannections etc complete all as specified and directed by Engr-in-charge. Note -rate quoted is deemed to be included for any alteration or fabrication work required to be carried out for fixingn of MCCB at exisiting feeder pillar).
28Supply, fixing and testing MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete with all connected accessories including taking out old UNSV MCCB from the existing panel after disconnecting all incoming and out going UG cable cannections etc complete all as specified and directed by Engr-in-charge. Note -rate quoted is deemed to be included for any alteration or fabrication work required to be carried out for fixingn of MCCB at exisiting feeder pillar).
29Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by GI strip 25x4 mm as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
30NOTES :- 1.For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Disclaimer :