Work For Increasing Capacity Of 33/11 Kv Substation Sarkadapuram (1X5 To 2X5mva), District-Moradabad, moradabad-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Work For Increasing Capacity Of 33/11 Kv Substation Sarkadapuram (1X5 To 2X5mva), District-Moradabad. Submission Date for this Tender is 25-04-2024. Civil Work Tenders in moradabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43062021
Corrigendum : Work For Increasing Capacity Of 33/11 Kv Substation Sarkadapuram (1X5 To 2X5mva), District-Moradabad
Open Tender
Indian
Uttar Pradesh
moradabad
25-04-2024

Tender Details

Work For Increasing Capacity Of 33 / 11 Kv Substation Sarkadapuram ( 1X5 To 2X5mva ) , District-Moradabad- 1 Supply Of Following Items :- ( By Contractor ) For Item No. 1.01 To 1.111.01 Stone Pad ( 300×300×75Mm ) 2 Pg Clamp For Of Required Size 3 Number Plate With Clamp & Nuts 4 Danger Board & Clamps With Bolts And Nuts 5 Ms Nut & Bolts 6 Barbed Wire Gi 7 G.I Pipe 150 Mm Dia, 3 Mtr Long 8 33Kv Ct Junction Box 9 Holding Clamp For Gi Pipe 10 Holding Clamp For Channel And Angle 11 M.S U-Type Holding Clamp For Earthing Of Neutral ( Delta ) 12 C.T Connector For Providing Input & Output Coneection 13 Safe Carriage Of Following With Loading & Unloading At Both Ends Respectively. ( Under Jurisdiction Of Pvvnl ) Or Item No. 2.01 To 2.311.01 33 Kv Bus Isolator 800 Amp / Line Isolator 14 33 Kv Fuse Set 15 33 Kv Lightening Arrestor 16 33 Kv Post Insulator 17 2X2.5 Mm2 Control Cable 18 4X2.5 Mm2 Control Cable 19 11 Kv 3×300Mm2 Xlpe Cable Jointing Kit ( Outdoor ) 20 11 Kv 3×300Mm2 Xlpe Cable Jointing Kit ( Indoor ) 21 11 Kv 3×185Mm2 Xlpe Cable Jointing Kit ( Outdoor ) / 11 Kv 3×50Mm2 Xlpe Cable Jointing Kit ( Outdoor ) 22 11 Kv 3×185Mm2 Xlpe Cable Jointing Kit ( Indoor ) / 11 Kv 3×50Mm2 Xlpe Cable Jointing Kit ( Indoor ) 23 11 Mtr. St Pole, Sp-55 Bottom Galvanized 24 11 Kv Disc Insulators T&C Type 45 Kn Polymeric 25 11 Kv Disc Fitting 45 Kn 26 11 Kv Polymeric Pin Insulator 27 M.S. Earthing Rod Of 20×2500Mm And 6 Swg Wire 28 Stay Complete ( Stay Rod 16×1800Mm, Stay Wire 5 Kg, Stay Insulators, Sty Clamps, Bolts & Nuts With Grouting ) 29 11 Kv Tpmo ( 3 Phase ) 30 11 Kv Fuse Set ( Drop Out ) ( 3 Phase ) 31 11 Kv Incoming Switch Gear 600 / 300 / 5A 350Mva 32 11 Kv Outgoing Switch Gear 200 / 100 / 5A 350Mva 33 11 Kv Bus Coupler Vcb, 350 Mva 34 33Kv Mocb / Vcb 800A750mva 35 33Kv Control Panel For Double T / F Without Differential Relay 36 33Kv Ct 200 / 100 / 1-1A 37 Acsr Dog Conductor 38 11Kv 3X300 Mm2xlpe Cable / 11Kv 3X185mm2 Xlpe Cable / 11Kv 3X50mm2 Xlpe Cable 39 33 / 11Kv 05Mva Power Transformer ( Safe Carriage From Any One Of The Pvvnl Store / 33 / 11Kv Subsation As Per Respo Norms To Working Place ) 40 M.S Channel 125X65x6mm 41 M.S Channel 100X50x6mm 42 M.S Angle 75X75x6mm 43 M.S Round 32Mm Dia 44 Safe Shifting Of 05Mva, 33 / 11 Kv, Power Transformer From Out Side Of Switchyard To Near Power Transformer Plinth In Switchyard. 45 Erection & Installation Of 05Mva Power Transformer On Power Transformer Plinth By Fixing All Accessories Like Radiators, Conservator Tank, Filling The Transformer Oil To Desired Level And Ensuring That There Is No Leakage After Providing New Radiator Seals Etc By The Contractor In Case Of 5Mva T / F Complete Job In All Respect. Reconnecting 2 Nos. Earthing Strip To Transformer Body. 46 Earthing Of Outdoor Equipments In Switchyard, As Per Site Requirement / As Per Pvvnl Guideline Details As Given Below:- For Item No. 4.01 To 4.034.01 Digging Of Trench Of Size-0.50X0.75X30m., For Laying Of Earthmat Throughout In Required Half Portion Of Switchyard And Refilling & Ramming Of The Same Earth Into The Trenches After Completion Of Earthmat Work, Laying Of 32Mm.Dia M.S.Bar In Trench, Properly In Alignment Along The Length And Width In Switchyard, Cutting Of 32Mm.Dia M.S.Bar-3M.Long And Making One End In Conical Shape, By Forging Process And Driving It Into The Earth, In Trench At Fixed Distance As Per Drawing And Properly Welding With M.S.Bar Earthmat, Proper Continuous Electric Welding Of Overlap Joints Of M.S.Bar Upto A Length Of 150Mm. On Both Sides, Along The Length Of M.S.Bar And An Extra Piece Of 12Mm M.S.Round-150Mm.Long, Providing On Both Sides Of Overlap Joints And Continuous Electric Welding On Both Side, Along The Length Of M.S.Bar. All Joints Shall Be Painted With Black Bituminous Paint, Proper Electric Welding At X-Joints Of M.S.Bar And Welding By Providing 25X6mm.”U” Type Clamp Of M.S.Flat, And Proper Continuous Electric Welding With M.S.Electrode And M.S.Bar At Each X-Joints. All Joints Shall Be Painted With Black Bituminous Paint And As Per Site Requirement. 47 Providing &Laying Of G.I.Strip Of Size 50X6mm For Connecting The Earthmat With Each Equipment ( Bus Isolators, 33Kv C.T., 33Kv V.C.B., L.As., Fuse Set, Post Insulators, T / F Body & Its Neutral And M.S.Frame Of Cabe Supporting Structure ) , Various Steel Structures. The Work Also Includes Cutting, Bending, Straightening, Over Laping And Welding The Earth Strip With Earth Mat And By Using High Quality Arc Welding In Already Digged Trenches, As Per Pvvnl Guidline And As Per Site Requirement. 48 Fixing M.S Round 32Mm Dia And Making Delta Earthing For Power T / F Neutral / L.A As Per Respo Norms. 49 Making Earthing Of All 11Kv Switchgears, P.T. And Other Outdoor Equipments On Both Earth Terminal Inside The Control Room By G.I.Strip In Size 50X6mm. With 32Mm. Dia M.S.Round Laid In Trench With Proper Electric Welding, As Per Pvvnl Guidline. 50 Supply & Erection Of Water Level Earthing By Boring And Lowering By Providing Of G.I.Pipe Size 40Mm Dia, Into The Ground Upto Water Level Or Minimum 20Mtr, Which Ever Is More, With The Lower End Of Solid Copper Cone Approx 224Mm Long And 750Gm In Weight Shall Be Provided And Screwed In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg, From The Cone Upto The Ground Surface Where It Will Be Bolted To The G.I. Strip For Transformer Neutral Connection, The G.I.Strip Will Be Connected To Star Point Through Providing Copper Bond Strip Of Size-35X6mm, As Per Pvvnl Guidline. 51 Construction Of 1No. Plinth For 5Mva / 10Mva, 33 / 11Kv T / F, In Size-3.46X4.46 Mtrs., As Per Drawing, As Per Pvvnl Guidline And Site Requirements, Details As Given Below:-For Item No. 7.01 To 7.037.01–Excavation Of Earth In Foundation. Cement Concrete In Foundation In Ratio 1:6:12, Cement, Sand & Brick Ballast., First Class Brick Work In Ratio 1:4 With Cement & Coarse Sand Mortar., Cement Concreting Inner Side Of Plinth In Ratio 1:4:8, Cement, Coarse Sand And Stone Shingle. M.S.Work For Re-Inforcement 12Mm. Tor At A Distance Of 15Cms. Apart, Including Cutting, Bending & Binding By Wire To Each Other For Making Jal In Two Layer, 12 To 15Cms. Apart. 52 Fixing Of 3.5Mtr.Long, 2No. Rail Pices, 90Lbs, On Top Of Plinth At Proper Distance In Alignment By C.C. 53 Cement Concrete In Ratio 1:2:4, Cement, Coarse Sand & Stone Shingle, On Top Of The Plinth, Including Fixing Of M.S.Tor Jal. 12Mm.Thick Cement Plaster In Ratio 1:4, Cement & Sand Mortar, On All Side Of Plinth, Neat Cement Coating 3Mm.Thick On Top Surface Of Plinth. 54 Installation Of 33Kv Bus Isolator / Line Isolator With Structure, Fabrication, Excavation, Erection, Grouting ( With Cement, Coarse Sand And Stone Shingle ) And Making Of Plinth Of Bus Isolator Structure As Per Respo Drawing, As Per Pvvnl Guidline And Site Requirements :For Item No. 8.01 To 8.028.01Fabrication Of Structure, Including Cutting, Straightening & Drilling Of Holes In Channel / Angle Including Supply Of Materials. 55 Excavation Of Earth, Grouting Of Structure In C.C. Ratio 1:4:8, Erection Of Line / Bus Isolator Structure In Proper Alighment., Making Plinth By C.C. Ratio 1:3:6 And 12Mm Thick Plastering On Plinth In Ratio 1:4 56 Excavation Of Earth In Size, Making Fabrication & Erection Of Structure By Making Plinth C.C Ratio 1:3:6, 12Mm Thick Plasting On Plinth In Ratio 1:4 :: For Item No. 9.01 To 9.04 As Per Respo Norms.9.01 – Post Insulator Structure 57 33Kv C.T Strucure 58 33Kv Fuse Set Structure 59 33Kv L.A Structure 60 Installation & Mounting Of Materials On Erected Structure ( The Work Also Includes Safe Removal Of Old Items & Height Incrasing Of Existing Structures By Providing M.S Channel / Angle As Per Site Requirement If Applicable ) : For Item No. 10.01 To 10.0510.01 Mounting Of 33Kv Post Insulator 61 33Kv C.T ( 200 / 100 / 1A, 400 / 100 / 1A ) 62 Mounting Of 33Kv Fuse Set 63 Mounting Of 33Kv L.A 64 33Kv Bus Isolator / Line Isolator 65 Construction Of Plinth For The Structure Of 33 Kv Vcb As Per Details : For Item No. 11.01 To 11.05.11.01 A ) Excavation Of Earth Of Size ( 2.4×1.5×1.0 ) M Pits For Construction Of Plinth. ( 3.6 Cum ) 66 B ) Brick Ballast Ratio ( 1:4:8 ) ( Cement, Sand & Brick Ballast ) For Foundation Work ( 2.4×1.5×0.15 ) M Plinth. ( 0.54 Cum ) 67 C ) C.C. Work In Ratio 1:2:4 ( Cement, Coarse Sand &Stone Grit ) Of 20Mm Size For Making Plinth Of Size ( 2.4×1.5×1.00 ) M And Grouting Of Foundation Bolts 04 Nos. For 33 Kv Vcb. ( 3.6 Cum ) 68 D ) 12 Mm Thick Plaster With Cement Mortar In Ratio 1:4 ( Cement & Fine Sand ) Of Plinth Of 0.15 M Above Ground Level Size ( 2.4×1.5 ) M. ( 4.77 Cum ) 69 E ) Assembling And Installation Of 33 Kv Vcb On The Vcb Out Door Structure On The Plinth.Adjustment Of Operating Mechanism In Proper Alignment For Smooth Operation Of The Same. The Work Also Includes Fabrication Of Addition Arrangement For Proper Fixing, If Required And Also Safe Removal Of Old 33Kv Vcb If Applicable. 70 Laying, Stringing & Sagging Of Acsr Dog Conductor From Main Bus Bar To Power T / F, Through Post Insulator, Bus Isolator, C.Ts, Vcb And L.As., Byproviding & Fixing P.G.Clamp / Connectors, Suitable For Dog / Panther. 71 Erection Of I / C Switchgear, Bus Coupler, O / G Switchgears & Double T / F Control Panel In Alignment, In Control Room, Including Safe Shifting, From Dump Place. The Work Also Includes Safe Removal Of Old Switch Gears To Safe Place If Applicable. Making 4No. Pockets For Each And Providing / Fixing Of Reg Bolt By Cc In Ratio 1:2:4, With Tightening Also. As Per Pvvnl Guidline. 72 Commissioning & Fixing Of Bus Bar ( Copper ) , Between Each Switchgear, Double T / F Control Panel Control Cable, By Bolt, Nut & Washers And Ht Compound And Providing & Tapping Ht Tape, Empire Tape & Pvc Tape, On Each Joint & Bus Coupler Connect Which Existing Bus-Bar. ( If Extra Fitting / Adjustment Or Suitable Copper Bus-Bar For Fitment Required Then Provided By The Contractor ) 73 Construction Of Double Pole Structure :- Erection For Double Pole Structure On Stp 11M.Long, With Fabrication Of All Accessories, Such As Channel / Angle, 11Kv Tpmo, Fuse Set, Disc Insulator & Pin Insulators Etc & Fixing Of All Accessories On Double Pole, By Providing &Fixing M.S.Clamp Withbolt, Nut&Washers. Earthing To Be On Each Supports By M.S.Earthing Rod And Connecting Between Rod &Supports, By G.I Wire Of 6 Swg As Per Respo Norms. 74 Grouting Of Stp 11M. Long, With Cc In Ratio 1:4:8, Complete In All Respect, As Per Respo Norms. 75 Fixing Of Stay Set-16X1800mm. On Double Pole, Including Digging Of Pits Of Size-0.75X0.75X1.5M. Grouting In Cc Ratio 1:4:8 Cement, Sand & Stone Shingle. Binding And Nozelling Of Stay Wire, Complete In All Respect, By Providing & Fixing Of Stay Clamp, As Per Respo Norms. 76 Preparation Of 11 Kv Power Cable Ends: As Per Respo Specification Of The Following : For Item No.18.01 To 18.02 18.01 Making Ofcable End Termination By Heat Shrinkable Out Door Jointing Kits Suitable For 11Kv, 3X300q.Mm Xlpe Cable. Providing, Fixing And Crimping Of Proper Size Good Quality Lugs Complete In All Respect. 77 Making Ofcable End Termination By Heat Shrinkable Indoor Jointing Kits Suitable For 11Kv, 3X300sq.Mm Xlpe Cable.Providing, Fixing And Crimping Of Proper Size Good Quality Lugs Complete In All Respect. 78 Preparation Of 11 Kv Power Cable Ends: As Per Respo Specification Of The Following : For Item No.19.01 To 19.0219.01 Making Ofcable End Termination By Heat Shrinkable Out Door Jointing Kits Suitable For 11Kv, 3X185q.Mm Xlpe Cable. Providing, Fixing And Crimping Of Proper Size Good Quality Lugs Complete In All Respect. 79 Making Ofcable End Termination By Heat Shrinkable Indoor Jointing Kits Suitable For 11Kv, 3X185sq.Mm Xlpe Cable.Providing, Fixing And Crimping Of Proper Size Good Quality Lugs Complete In All Respect. 80 Making, Fabrication And Erection Of Neutral Earthing L Type Support Made Of M.S. Channel Size 100×50Mm. Structure Shall Be 4 Mtr. Long With 1 Mtr. Arms. Structure Shall Be Grouted In Ratio 1:3:6 In Block Size 300×300×700Mm And Painted With One Coat Of Ready Mixed Primer And Two Coat Of Enamel Aluminium Paint Work Includes Connecting Neutral Bushing Rod Of Power Transformer And M.S. Earthing Strip With The Help Of Flexible Copper Bond Size 35X6mm ( By Providing ) M.S. Bolt And Washer. 81 Cable Support : For Item No. 21.01 To 21.0221.01 Making, Fabrication And Erection Of Cable Support Made Of Two Pieces Of M.S. Channel ( 100X50x6 ) Mm, Joined To Each Other By Means Of M.S. Channel Pieces Of Each By Welding At Equal Intervals And Grouting In A Block Of Size ( 300X1000x1000 ) Mm In C.C. 1:3:6 Complete With One Coat Of Ready Mixed Primer And Two Coats Of Al. Paint. Work Includes Providing Of Three Nos. M.S. Clamps Made Of ( 50X6 ) Mm M.S. Flat For Holding The Cable Including Nuts And Bolts With Stone Pad Of Size ( 300X300x75mm ) . 82 Providing & Fixing 110Mm Dia 2Mm Thick 2M Long G.I.Pipe Over 11Kv, 3X300sq.Mm Xlpe Cable Before Mounting The 2No. Cable On Cable Support Structure. Work Includes Fixing Of Clamp, Sealing Of Top And Bottom End Of The G.I.Pipe. One End Of G.I.Pipe Is To Be Buried Under Earth About 500Mm. 83 Copper Bus Bar Support T-Type M.S.Structure ( As Per Site Requirement ) : For Item No.22.01 To 22.02 22.01 Makingfabrication And Grouting Erection Of M.S. Frames For Support Of Copper Bus Bar In L.V. Side Of Power Transformer. The M.S. Frame Shall Be Made Of M.S. Channel ( 100X50 ) Mm In T Shape. Drilling Of 3 Nos. Hole On The Top Channel For Fixing Of 03No. 33 Kv Post Insulator. The M.S. Frame Shall Be Painted With One Coat Of Primer & Two Coat Of Aluminium Paint And Grouting The Frame In C.C. Ratio 1:3:6 In A Block Of Size ( 300X300x700 ) Mm With Stone Pad ( By Providing ) Of Size ( 300X300x75mm ) . The Work Also Includes The Fixing Of 33Kv Post Insulator By Aluminium Binding Wire In Complete With Nut & Bolts. 84 Supply & Fabrication Of Copper Bus Bar Of Size ( 2400X50x6 ) Mm In L.V. Side For 05Mva And ( 3000X65x8 ) Mm For 10Mva T / F As Per Requirementfor Power Transformer, Work Includes Connection Of Outside Bus Bar In L.V. Side Busing Rod Of Power Transformer And Other Side With Outdoor 11 Kv Cable Box As Well As Providing Empire Tape And H.T. Tape Etc. For Proper Insulation Work Covering Copper Bus-Bar In Complete. 85 Fixing Of Cable Box On 5Mva / 10Mva T / F, 11Kv Switchgears, By Bolt & Nuts And Tapping The Joints By Providing Ht / Empire / Pvc Tape. 86 Mounting Of 11Kv Cable Boxes On Double Pole, By Providing & Fixing Of M.S.Clamp, Made Of 65X6mm. M.S.Flat, With Bolts, Nuts & Washers, Including Providing & Fixing 3Mm. Thick 150Mm. Dia G.I.Pipe-3M.Long, With Pipe Supporting Clamp-2No. On Each, Made Of 65X6mm M.S.Flat. 87 H.T. Power Cable Laying : For Item No.28.01 To 28.0228.01 Laying And Dressing Of 11 Kv 3×300 Mm2 / 3×185 Mm2 Power Cable In Air / Trench. 88 Laying 11 Kv, 3×300Mm2 / 3×185Mm2 Xlpe, Power Cable From Power T / F To Incoming Switchgear / Outgoing Switch Gear To 11 Kv Double Poles In The Cable Trench 0.45M Wide, 0.90M Depth. Providing 150 Mm Thickness Local Sand For Cushion Beneath And 150 Mm Above The Cable ( Quantity Of Local Sand Required 0.375 Cubm / M In Length ) . The Cable Shall Be Duly Protected By Brick. On Both Side Of Cable By Laying Bricks Vertically And Bricks Would Also Be Laid Horizontally On Top Of Vertically Laid Bricks Along The Cable ( Minimum 18 Nos. Per Mtr. Length Are To Be Laid Top And Outer Side Along The Cable. The Work Includes Digging Of Trenches, Laying Of Cable In Under Ground Trenches, Joining Of TerminalS, Back Filling Of Earth And Testing And Commissioning Of Power Cables Etc. Spare Cable Shall Be Left Over And Laid In The Trenches In Shape Of 6M Rings At Both Ends. At The End Of Feeder Cables, Where The Cable Is To Be Laid Across Pucca / Main Road, 150 Mm Dia G.I. Pipe Will Be Weared Over The Cable In The Cable Trench For The Protection Of Cable. G.I Pipe 150Mm Dia Will Be Provided By Contractor. 89 Laying Of Control Cable In Packka Trench, From Vcb / Cts / T / F To 33Kv Control Panel And Making Connection For Operation & Protection Of Equipments, By Using Ferrules Including Commissioning Battery Charger With Battery By Providing Copper Lead With Lugs Etc & Dressing Of Control Cable And Making Arrangement For Testing In The Equipments. 90 Providing & Fixing 1 No. Mcb Box 63Amp. Tpn And 03 No. 32 Amp. Spn Box And Power Plug On Wall And It Is Proper Grouting Including It Is Connection With A / C Supply By Providing Proper Size Of Connection Wire As Per Pvvnl Guidline. 91 Construction Of Control Cable Trench In Switchyard : For Item No. 29.01 To 29.05 ( As Per Respo Norms ) 29.01 – Consstruction Of Control Cable Trench Of Size 30Cmx30cm With Trench Wall Thickness 23Cm After Exavation Of Earth By Using 1St Class Bricks Work In Cement Mortar In Ratio 1:4 With C.C Work Foundation In Ratio 1:4:8 ( Cement Sand & Brick Blast ) 92 Providing &Grouting Of M.S.Strip Of Size 25X6mm In Cable Trench 100Mm Above Floor Level And At Equal Space Distance 300Mm 93 Providing And Grouting Of M.S.Angle Iron Of Size 50X50x6mm In Upper Edge Of Trench. 94 C.C.Work On The Top In The Ratio 1:2:4 In The Grouting Of Edge Of The Trenches. & Plastring Of Trench. 95 Providing Fabrication And Fixing Cable Trench Cover Of Providing M.S.Angle Iron Size 40X40x6mm Of Size 0.3M Wide 0.5 To 1.0 Mtr Length. As Per Site Requirement. After Construction Of Cable Trench. 96 Construction Of Fire Wall, As Per Drawing, Made Of Cement, Sand, Concrete, Bricks, Etc., Which Will Be Arranged By The Contractor. ( Dimention-4.5X5mtr Or As Per Drawing / Site Requirement ) 97 Construction Of S.S.Os. Approach Road-1.2M Wide In Switch Yard By Laying Dry Brick-Ballast In 15Cm Layer, 115Mm Thick Brick Work 1:4 In Both Side Of Edge, Providing 10Cm Thick Cc In Ratio 1:2:4. The Work Includes Proper Plastering Top & Side Of Road And Making Groove, Leveling & Dressing Of Earth Beneath The Brick Work On Edge. As Per Site Requirement & Pvvnl Guidline. 98 Painting Of The Following Structure With One Coat Of Ready Mixed Primer And Two Coats Of Isi Mark Alumn. Paint After Rubbing With Sand Paper To The Surface Of The Structure Includidng Labour And T&P Complete In All Respect.:For Item No.32.01 To 32.0632.01 – Line Isolator Structure 99 Fuse Set Structure 100 Post Insulator, L.A.Structure 101 V.C.B.Structure, C.T.Structure 102 M.S.Frame For Cable, Neutral, Copper Bus Suppl 103 11Kv Double Pole Structure On Sp-55 Stp 104 Providing Of Chequerred Rubber Sheet Of Size-1800X900x10mm. In Control Room. 105 Hiring Of D / G Set, Including Carriage, Loading, Unloading & Operating Charges ( With Fuel ) At 33 / 11Kv Substation, :For Item No. 34.01 To 34.0234.01 – 20 Kva, 3 Phase D / G Set For Testing Of Power T / F & Equipments Installed At Sub-Station. 106 5 Kva, Single Phase D / G Set For Welding / Testing Of Equipments Installed At Sub-Station. 107 Providing Required No. Ofskilled Technicians For Testing & Commisning To Work On Power T / F, Ht / Lt Panels, During Testing As Assisting Technical Hands Of Test Team During Commissioning & Energisation. After Installation Of New Protection Equipments ( 33Kv Vcb, C.T & Double T / F, Single T / F Control Panel ) The Contractor Will Ensure Its Testing On His Own Expences.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Apr-2024 Date Extend Date 25-04-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 20000.0 /-
Tender Value
INR 20 Lakhs /-