Tender For Special Repair Works To 1 No. Of Ins, 3 Nos. Of Si And 36 Nos. Of Pc And Hc Quarters At Jolarpet In Tirupathur District., tirupathur-Tamil Nadu

Tamil Nadu Police Housing Corporation Limited-TNPHC has published Tender For Special Repair Works To 1 No. Of Ins, 3 Nos. Of Si And 36 Nos. Of Pc And Hc Quarters At Jolarpet In Tirupathur District.. Submission Date for this Tender is 15-04-2024. Personal Computers Tenders in tirupathur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

43061796
Tender For Special Repair Works To 1 No. Of Ins, 3 Nos. Of Si And 36 Nos. Of Pc And Hc Quarters At Jolarpet In Tirupathur District.
Open Tender
Indian
Tamil Nadu
tirupathur
15-04-2024

Tender Details

Special Repair Works To 1 No. Of Ins, 3 Nos. Of Si And 36 Nos. Of Pc And Hc Quarters At Jolarpet In Tirupathur District.

Key Value

Document Fees
Refer document
EMD
INR 24300.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Special repair works to 1 No. of INS, 3 Nos. of SI and 36 Nos. of PC/HC Quarters at Jolarpet in Tirupathur District.
Sl. No. Item Description
1WATER SUPPLY ARRANGEMENTS 51.1: Supply and erection of Rotational Moulded Polyethylenewater storage tanks (HDPE Cylinderical vertical type) for outdoor use having capacity of 700 litres (excluding free board)of approved brand (superior variety) withISI Mark
252 : PVC Water supply (ASTM) a. 32 mm dia
3b. 25 mm dia
4Electrical arrangements 74 : Charges for fixing of "Fan"
5ANNEXURE-I 10.5.1: Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") 110 mm tk (B.P.) (using crushed stone sand) a. In Foundation and basement
614.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
723.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
829.9.1 : Floor ceramic tilesusing Grout (Tile Joint Filler)(antiskid) (using crushed stone sand)
932.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx23cmx20mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
1033.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) including plasticizer
1138.7.1 : Two coats of Plastic Exterior Emulsion PAINT including primer for outer walls
1243.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
1344.6 : PVC SWR 110 mm dia with ISI marktype- A for Rain water down fall pipe
1450.6.1 : Precast slab 50 mm tk.in C.C. 1:3:6 with fibre (using crushed stone sand)
1554.1.1 : S & F of 15mm dia half turn CP long body tap
1654.2.1 : S & F of 15mm dia half turn CP short body tap
1756.3.1: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P" or "S" trap -In G.F.(using crushed stone sand)
1856.4.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P" or "S" trap -Other than G.F.(using crushed stone sand)
1957.1.2 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap (using crushed stone sand)
2058.3 : PVC SWR pipe (Soil line) with ISI mark - type "B". a. 110 mm dia.
21b. 75 mm dia.
2261.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
2375.1.2 : Supply and delivery of48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
24211.2: Clean removal of the old cement plastering both inside and outside from the existing walls of brick masonrywithout damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant and necessary scaffolding if necessary etc., all complete in all respect and as directed by the departmental officers.
25214: Dismantling the old damaged brick work in Cement mortar and clearing away from the work site, including labour charges etc all complete and as directed by the departmental officers a) upto 3m height.
26218: Dismantling the damaged pressed tiles in cement mortar without affecting the adjacent structures in all floors including the cost of required tools and plants and clearing the debris away from the site etc., all complete and as directed by the departmental officers.
27384 : S&F of PVC flushing cistern 10 litres capacity
28ANNEXURE - II A1: Painting the old walls with two coats of approved Exterior Emulsion Paint of first class quality paintincluding cost of paint, putty, brushes, watering, curing, thorough scrapping, labour charges etc., etc., complying with relevant standard specification. The paint should be supplied by the contractors at his own cost. (The quality and shade of the paint should be got approved by theExecutive engineer before use)
29A2: Painting the old walls with one coat of ready mixed plastic emulsion paint of first class quality paint of approved colour and shade over a priming coat on cement plastered/concrete wall surfaces and thorough scrapping including cost of necessary brushes, labour charges, patty etc., complying with relevant standard specification. The paint should be supplied by the contractors at his own cost. (The quality and shade of the paint should be got approved by theExecutive engineer before use)
30A3: Painting the old Iron work and other similar works such as steel windows ventilators and grills with one coat of approved Ist class synthetic enamel ready mixed paint of approved quality and brand, thorough scrapping including cost of paint, brushes labour charges etc., complete.(The quality and the brand of paint should be got approved by the Executive Engineer before use) complyingwith relevant Standard specifications.
31A4: Painting the old wood work with one coat of approved Istclass synthetic enamel paint including clean removal of old paint using sand sand paper as required by the departmental officers including cost of paint, brushes labour charges etc., all complete as directed by the departmental officers. (The quality and the shade of paint should be got approved by the Executive Engineer before use) complying with relevant standard specifications.
32A5: White washing one coat for old walls using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding, thorough scrapping and washing with soap, soda water etc., all complete and complying with relevant standard specifications.
33A6: Plastering in C.M. 1:5, 20mm tk. for old walls finished with neat cement (using crushed stone sand) including plasticizer
34A7: Pointing the top of Pressed tile roof withCM 1:3,12mm thick with waterproof compound 2% of cement to the existing roof including cost of all necessary groove cutting and finishing etc, complete.
35A8: Removal of Cut Stone Slabs / RCC Cover Slabs without damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant and necessary scaffolding if necessary etc., all complete in all respect and as directed by the departmental officers.
36A9: Dismantling of existing damaged IWC without damaging the existing structure and surroundings and clearing the debris away from the site including cost of required tools and plant etc., all complete in all respect and as directed by the departmental officers.
37A10: Supplying, laying, fixing and jointing the followingDia GI, GM, CI, PVCandMSSpecIalsof bestandapprovedqualityhavingISImarkincludingcostofspecialsanddeliveryatsite of work etc., all complete and as directed by thedepartmentalofficers. a) 32mm dia GM gate valve
38b) 25mm dia GM gate valve
39c) 32mm dia UPVC Union
40d) 25mm dia UPVC Union
41e) 32mm dia UPVC Elbow
42f) 25mm dia UPVC Elbow
43A11: Supplying and fixing of Aluminium Door Stopper with Rubber Bush with required screws incluidng cost of materials anad labour charges for fixing etc., all complete and as directed by the departmental officers.
44A12: Supply and fixing the following electrical items with ISI mark and approved make including cost of materials and labour charges for fixing etc., all complete and as directed by the departmental officers. a) Stepped Electronic 300W / 450W Square Type Fan Regulator
45b) 5 Amps Switch (Flush type)
46c) 5 Amps 3 Pin & 2 Pin Combined Flush Type Wall Socket only
47d) 5 Amps / 15 Amps 3 Pin Flush Type Wall Socket only
48A13: Supplying & fixing of 15mm dia CP Pillar tap (Heavy type) for wash basin etc., all complete and as directed by the departmental officers.
49A14: Supplying & fixing of 15mm dia CP Angle valve for wash basin etc., all complete and as directed by the departmental officers.
50A15: Cleaning the existing Inspection chamber such as sewage water and liquid using 5000 litres capacity vehicles and depositing in same away from the site including cleaning tank with water after disposal, hire and conveyance charges for the vehicles, labours all tools and plants employed there of as directed by the departmental officers.
51A16: Cleaning the sludges in existing drain of size (10.00x0.20x0.45m) etc., all complete.
52A17: Supplying and fixing of LED blubs suitable for fixing it to pendent / bakelite battern holder of best approved variety b) 12 watts LED bulb for bulk head fittings
53A18: Supplying and fixing of 18W LED TUBE LIGHTS 4" long with necessary fittings and charges for assembling and fixing
54A19: Supplying and fixing of water tight bulk head fitting with guard suitable for 12W LED lamp
55A20: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings
56A21: Run of main with 2 wires of 1.5 sq.mm. copper PVC insulated unsheathed single core 1.1 kv grade cable with continuous earth by means of 1.5 sqm copper PVC insulated unsheathed single core1.1. kv. grade cable (open wiring)
57A22: Run of main with 2 wires of 2.5 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming to IS: 694/1990, (Open Wiring)
58A23: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (open wiring) a. Light Point with ceiling rose.
59b) Light Point without ceiling rose.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail