Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #43060620

Tender For Repair Maintenance Cleaning Of Sewer Lines Man Holes And Covers And Certain Sanitary Fittings And Periodical Services To Buildings At Varunapuri I Ii And Uwr Under Age Br Ii Of Ge Nw Vasco

Issued by Statutory Bodies & Commissions/Committees · vasco, Goa
Tender Value
45.50 Lakhs
Estimated cost
Bid Submission
08 Apr 2024
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vasco → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair Maintenance Cleaning Of Sewer Lines Man Holes And Covers And Certain Sanitary Fittings And Periodical Services To Buildings At Varunapuri I Ii And Uwr Under Age Br Ii Of Ge Nw Vasco

BOQ

NAME OF WORK : REPAIR / MAINTENANCE / CLEANING OF SEWER LINES, MAN HOLES AND COVERS AND CERTAIN SANITARY FITTINGS AND PERIODICAL SERVICES TO BUILDINGS AT VARUNAPURI – I, II AND UWR UNDER AGE B/R – II OF GE (NW) VASCO. (Tender ID NO. 2024_MES_646958_1)
Sl. No. Item Description
1REPAIR / MAINTENANCE / CLEANING OF SEWER LINES, MAN HOLES AND COVERS AND CERTAIN SANITARY FITTINGS AT VARUNAPURI – I, II AND UWR UNDER AGE B/R – II
2Cleaning of blockage in sewer line of 100 mm dia by rodding from one MH to next MH and washing through infresh water including removing all sludge fromthe sewage line and man hole including removing existing MH cover and Refixing properly after cleaning and disposed off sludge properly outside MD land all as directed (cleaning of manhole will be measured and paid separately.
3All as per item No. 1.01 above but sewage line of 150 mm dia.
4All as per item No. 1.01 above but sewage line of 200 mm dia.
5All as per item No. 1.01 above but sewage line of 300 mm dia.
6Cleaning of manhole of any description of size n. exc 1.5 M indepth including lifting up and removing sludge and accumulated/ semi solid sludge and other foreign material with trailor mounted sewage cleaning pumps/mechanical devices and removing to a distance n. exc 250 m where directed by Engineer-in-Charge & washing down with water for smooth function of sewage incl removal and refixing of manhole cover .
7All as per item No. 1.05 above but man hole exc 1.5 M depth & n. exc 2 M .
8All as per item No. 1.05 above but manhole exc 2 M depth & n. exc 4 M and -do-.
9Cleaningof septic tanks of 500 users capacity by bailing out water, removing sludge dust mud & other accumulated solids, semi solids etc including cleaning& sewage sludge and other materials deposited outside the MD land.
10All as per item No. 1.08 above butseptic tank of 250 user Capacity.
11All as per item No. 1.08 above but septictank of 150 user capacity
12Demolition of reinforced cement concrete cover slab for MH/Septic tank and removing the debris to a distance not exc 500 M as directed.
13M&L precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregatefor cover slab for MH/Septic tank set in CM 1:4 including formwork.
14M&L for 8 mm dia TMT bar cut to length, bend to shape required incl cranking bending & hooking ends & binding with MS wire annealedn. less 0.9mm dia.
15M&L for removal of blockage from WC by using rubber cup 125mm dia with wooden handle and clearing the blockage upto manhole with cleaning rod including removal of all materials from P trap of WC .
16M&L for removal of blockage from kitchen/bathroom /WHB by using rubber cup 125mm dia and clearing the blockage upto gully trapswith cleaning rod including removal of all materials from floortrap including dismantling and refixing of gratings.
17Demolition of laterite stone masonary walls built in CM and removing the debries to a distancenot exc 500 M as directed.
18Pre - cast cement concrete 1:3:6 masonry with Grade C-5.0, (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6
19M&Lrendering 10 mm thick inCM 1:4 on concrete surfaces finished evenand smooth without using extra cement.
20Excavation in trenches n. exc 1.5 M wide & n. exc 1.5 M in depth for foundation in soft/disintegrated rock and getting out.
21All as per item No. 1.19 above but depth exc 1.5M and n.exc 3M.
22All as per item No. 1.19 but in hard / dense soil.
23Demolition and breaking up of SGSW pipes set in cement mortar 200 mm dia
24All as per item No. 1.22 but 150 mm dia pipe.
25All as per item No. 1.22 but 100 mm dia pipe.
26Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for
27M & L concrete bed to drain pipe and including packing under haunching against the sides & pipe and after they laid and tested incement concrete 1:4:8 type D2 bore of pipe 200 mm dia.
28M & L concrete bed to drain pipe and including packing under haunching against the sides & pipe and after they laid and tested incement concrete 1:4:8 type D2 bore of pipe 150 mm dia.
29All as per item No. 1.27 above but for 100 mm bore.
30M&L for 200mm dia reinforced concrete pipes, class NP-2, laid and jointed complete with collars
31M&L for 150mm dia reinforced concrete pipes, class NP-2, laid and jointed complete with collars
32M & L PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in trenches or in floors and jointed as specified.
33Returning filling inincluding spreading levelling watering and wellramming in layers n.exc 25 Cmthick inhard/dense soil.
34Removal of excavatedrock/soil to a distance n. exc 50M and deposited where directed at a level n. exc 1.5 M above the starting point.
35DismantlingCI / PVC drain pipe 75/110 mm diaand taking out from walls/ trenches if required.
36S & F PVC (SWR) pipe 110 mm dia single socketed inany length with rubber ring jointed, fixed to wall with necessary clamping.
37S & F PVC (SWR) pipe 75 mm dia single socketed inany length with rubber ring jointed, fixed to wall.
38S & F PVC (SWR) pipe 110 mm dia single socketed inany length with rubber ring jointed, fixed to wall with necessary clamping in High rise bldg above 4 storey.
39S & F PVC (SWR) pipe 75 mm dia single socketed inany length with rubber ring jointed, fixed to wall in High rise bldg above 4 storey.
40M & L PVC (SWR) bends any radious 110 mm bore
41M & L PVC (SWR) bends any radious 75 mm bore
42M & L PVC (SWR) branch piece, single (Single Y) equal or unequal, 110 mm bore
43M&L PVC (SWR) branch piece, single (Single Y) equal or unequal, 75 mm bore
44M&L PVC (SWR) vent cowl 110mm bore
45S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement diametr of outlet 75mm
46S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
47M&L taking up or down old covers and setting in cement mortar 1:3 and flaunching with cement concrete 1:2:4 type B1 cast iron/RCC manhole covers and frames medium duty all as directed
48S&F in repair waste fittings 40mm, brass, chromium plated for glazed ware sinks /stainless steel sinks/ WHB with long screwed shanks and flynuts, flange end bedded in red lead cement concrete
49S&F in repair vitreous chine wash basin flat back size 550 x 400 mm white, excluding taps waste, chain and plug and porcelain stopper but including brackets
50S&F waste fittings 40mm, brass, chromium plated for glazed ware sinks/stainless steel sinks/WHB with long screwed shanks and flynuts, flange end bedded in red lead cement concrete
51S&F in repair plastic water closset seat cover for EWC, black closed pattern with flat bottom,and cover and mild steel chromium plated or aluminised hinging device
52S&F stainless steel gratings in repair 125mm dia with cement mortar 1:2 and matching with existing floor
53Supply & Fix WC of size 580 x 440 mm vitreous china squatting pan, Orissa pattern white with \"P\" or \"S\" trap front or back inlet and integrated foot rest including provn of lime concrete bedding etc fixed in repairs.
54S & F in repair PVC high level /low level flushing cistern, 10 Ltrs capacity including float valve , chain, PVC pipe including dismantling of old unserviceable flush tank.
55Supply only flush pipeofpolythelene of low or high density or PVC 32 mm dia for high level flushing cistern, fixed in repairs, including all joints and making good existing floor surface.
56S & F 15mm dia bib tapsstandard of PTMT any colour high pressure screwed for iron pipe (min weight 90 gms) fixed in repairs.
57S & F 15mm stop valves PTMT any colour high pressure screwed for iron pipe (min weight 90 gms) fixed in repairs .
58S&F Vitreous china wash down water closet (Pedestal pattern) (EWC) white, including fixing complete with ‘P’ or ‘S’ trap, fixed as in repairs complete all as specified and as directed.
59S&F PVC connection, 450mm long with brass CP check nuts suitable for connecting 15mm dia pipes, superior quality fixed in repairs, complete all as specified.
60Supply onlypillar tap PTMT of any colour high pressure screwed for iron pipe and fixed 15mm dia (minimum weight 110 gms)
61S&F in repairs pillar tap PTMT of any colour high pressure screwed for iron pipe and fixed 15mm dia (minimum weight 110 gms)
62Treating and finishing the sunken portion of WC area n.exc1.2 sqm each by sealing the edge of hole through which pipes are entering the sunken portion, using seal tape and grout the gapes using a non-shrink cementitious grout (Dr fixit, /STP / Krishna conchem) providing 10 mm thick rendering in CM 1:3 with and including water proofing compund.Apply first two coat ofWPC (cementitious products with acrylic emulsion polymer as binder using Dr fixit pidifin 2 K of pidilite industries or equivalent of Focrock / Krishna conchem) in the sunken portion and extended up to 15cm on the wall above the FFL.Immediately cover all the angle fillets with a 150 mm wide strip of ope woven glass fiber mesh of 2mm x 2mm.Apply the second coat of WPC after the first coat dry completely, providing necessary connection items suitable for wc, providing lime concrete complete all as specified as per manufacture instruction and as directed by Engineer-in-Charge. (WC measured separately)
63As per item No. 1.65 above but for bath/lobby without any PVC connection, fitting for area exceeding 1.2 Sqm and not exc 2 sqm each
64Taking up or down steel water tubing 15mm bore and connections.
65Taking up or downsteel water tubing20mm bore and connections.
66M&L CPVC pipes SDR 11 Class 1 laid in walls/ceiling or laying in floors outer dia 20mm dia including all fittings (Rates incl for making hole groves as applicable)
67M&L CPVC pipes SDR 11 Class 1 laid in walls/ceiling or laying in floors outer dia 25mm dia including all fittings (Rates incl for making hole groves as applicable)
68M&L CPVC pipes SDR 11 Class 1 laid in walls/ceiling or laying in floors outer dia 20mm dia including all fittings in High rise bldgs above 4 storey (Rates incl for making hole groves as applicable)
69M & L CPVC pipes SDR 11 Class 1 laid in walls/ceiling or laying in floors outer dia 25mm dia including all fittings in High rise bldgs above 4 storey (Rates incl for making hole groves as applicable)
70Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
71S & F Non skid coloured tiles of size 400 x 400 x 7 mm thick in floors etc, set and jointed in neat cement slurry and pointed in / hite / coloured cement to match all as specified.
72S & Fglazed ceramic tiles, coloured of size 450 x 300 x 7 mm thick with on vertical surfaces such as dado, skirting etc, set and jointed in neat cement slurry and pointed in white cement to match all as specified.
73M&L screed bed or bedding layer of mortar 15mm thick to receive floor tiles in cement plaster 1:4
74M&L rendering 10mm thick in CM 1:4 on brick work / concrete surface to receive tiles
75S&F Health faucet (ABS Body) mild steel cp suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook incl making connections and fixed in position complete in all respect as specified
76PERIODICAL SERVICES TO BUILDINGS AT VARUNAPURI – I, II AND UWR UNDER AGE B/R – II
77M & L brooming down or steel wire brushing scrapping down, smoke, moulds, moss and efflorescent salts, trading oiletc from old surfaces of wall plastered or unplastered including cornices andpilasters etc and applying one coat of white wash complete all as specified.
78M&L for preparation of old surface and applying one coat of oil bound distemper on ceiling
79M&L forpreparation of old surface and applying one coats of white wash on ceiling
80M&L forpreparation of old surfaceand applyingone coat of colour wash on old walls
81M&L forpreparation of old surfaceand apply one coat of cement base paint on oldwalls
82M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint (Ist quality)
83M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint
84M&L for preparation of old painted surfaces of wall and applying one coat of oil bound distemper
85M&L for writing letters/ bldg Nos on walls 7.5 cm high using synthetic enmel paint white over circular/ rectangular shaped black painted back ground (20 to 30 cm dia/long) complete all as specified.
86Taking down cement plaster of any description on brick or stone walls including racking ouit joint hacking for key, scrubbing down with water etc.
87Rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement.
88Rendering 10 mm thick on wall in cement mortar 1:6 on stone/masnory surfaces finished even and smooth without using extra cement.
89Rendering 15mm thick plaster in cement mortar 1:4 in two coats (10 mm thick backing coat + 5mm thick finishing coat) finished even and smooth without using extra cement includingwater proofing compound (Dr. fixit LW or equivalent 200ML per bag of cement) etc complete all as specified and directed.
90M&L for 3mm thick wall care putty on wall
91Preparing newly plastered surface of ceiling and applying two coats of oil bond distemper over a coat of alkali resistant primer.
92Preparing newly plastered surfaces of wall and applying two coats of OBD over a coat of alkali resisant primer
93M&L for preparation of old painted surfaces of wall and applying one coat of synthetic enemal paint over plastered surfaces
94Supply only Liquid water proofing compound all as specified.
95M & L preparing the old treated surfaces of wall and applying one coat of exterior grade weather proof antifungal paint complete all as per manufacturers instructions and as directed
96M&L removing peepul trees or any type of trees/vegitations with root from wall, roof slab, over head tank portions, shafts, rain water pipe portions etc,and applying acid or suitable chemical to the affected area to arrest further growth and making good damaged portions with PCC 1:2:4 all as directed by Engineer-in-Charge. (Safety precautions like rope, safety belts, helmets, ladder etc will be the responsibility of contractor)
97M&L complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint.
98Complete removal of existing treatment of plastered surface of external wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
99M & L preparation of newlyplastered surface and applying two coat of raincoat. Prime the surface with a coat ofPRIMESEAL diluted with potable water in ration 2:1 by volume prior to application of raincoat and allow it to dry for 2 to 3 hrs. Apply firstcoat of raincoat. Apply second coat of raincoatwith an interval of 5 to 6 hrs and allow to cure for 7 days all as directed and as per manufactures instruction. Make: M/S Pidilite Industries Ltd or Equivalent in M/S Krishana conchen product/STP Ltd (Note:- Priming coat and raincoat used shall be same Make/Manufactures)
100Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required, reconnecting and refixing in position upto 1000 Ltr capacity complete all as specified and as directed

AI Tender Summary

OUR REF NO 43060620
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.50 Lakhs
LAST DATE 08-04-2024
Authority
Authority Name Military Engineer Services
Work Description Repair Maintenance Cleaning Of Sewer Lines Man Holes And Covers And Certain Sanitary Fittings And Periodical Services To Buildings At Varunapuri I Ii And Uwr Under Age Br Ii Of Ge Nw Vasco
Basic Detail
Tender No 8591/E8
Bidding Type Tender
Location
City vasco
State Goa
Key Dates
Publish Date 28 Mar 2024
Submission Date 08 Apr 2024
Open Date 10 Apr 2024
Finance
Tender Value 45.50 Lakhs
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
317ad7b4-a9da-4bc3-9579-441b519398a3.html
8591TenderDocumentsSewage_1.pdf
BOQ_725541.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 28, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 08, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 10, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

317ad7b4-a9da-4bc3-9579-441b519398a3.html

pdf

8591TenderDocumentsSewage_1.pdf

xls

BOQ_725541.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender