|
| 1 | ARC OF WHRU for 1st year |
| 2 | O/H Diverter Damper seal Air Fan |
| 3 | Attending Gland Leakage in Chemical PP |
| 4 | Preparation HRSG Annual Hydraulic Test |
| 5 | Manhole opening / closing of HRSG |
| 6 | Blr Drum Manhole opening / closing of HR |
| 7 | HRSG Tube leakage |
| 8 | Attending Header Leakage |
| 9 | Clng CBD & IBD Tank |
| 10 | Clng Deaerator Strainer |
| 11 | Servicing Deaerator Spray Device |
| 12 | Servicing/ Replt Eco-SRV |
| 13 | Servicing / Replt of valve upto 2\" |
| 14 | Servicing / Replt of valve > 2\"to4\" |
| 15 | Servicing / Replt of valve >4 to 8\" |
| 16 | Servicing / Replt of valve > 8\"to 12\" |
| 17 | Servicing turbine barring gear |
| 18 | Servicing servomtr turbine contrl v/v |
| 19 | Servicing servomtr ESV of turbine |
| 20 | Replt turbine exhaust diaphragm |
| 21 | Hydraulic Oil filter Cleaning/Replt |
| 22 | Clng Main oil tank turbine |
| 23 | Replacing Lub Oil filter Cartridges ST |
| 24 | Cleaning of Lube Oil Cooler |
| 25 | Preventive maintenance of Oil Purifire |
| 26 | Servicing booster PP |
| 27 | Attending leakage ejector shell flange |
| 28 | Attending leakge flange/line water/steam |
| 29 | Clng condenser Hotwell |
| 30 | Ser of Cond Butterfly valve GB |
| 31 | Back Washing of Half Condenser |
| 32 | Fill Test of Condenser |
| 33 | Replt rubber expansion below stean cond |
| 34 | Clng condensate Extraction PP suction |
| 35 | Clng generator air cooler tubes |
| 36 | Decoupling/Coupling of Pump |
| 37 | Preventive Mtc of LLVT Dtain Pump |
| 38 | Replt of BRG |
| 39 | Replt/ servicing mechanical seal |
| 40 | Servicing/Replt of Jacking oil Pump |
| 41 | Preventive Mtc of CEP |
| 42 | Changing BRG |
| 43 | Replt/ servicing mechanical seal |
| 44 | Preventive maintenance of Gland steam ex |
| 45 | Oil topping in main oil tank |
| 46 | Greasing upto 2\" |
| 47 | Greasing > 2\" to 4\" |
| 48 | Greasing > 4\" to 8\" |
| 49 | Greasing > 8\" to 12\" |
| 50 | Welding of Joints upto 2\" |
| 51 | Welding of Joints > 2\" to 4\" |
| 52 | Welding of Joints > 4\" to 8\" |
| 53 | Welding of Joints > 8\" to 12\" |
| 54 | Removal of AOP/EOP |
| 55 | Installation of AOP/EOP |
| 56 | Gland Leakage upto 2\" |
| 57 | Gland Leakage>2\" to 4\" |
| 58 | Gland Leakage>4\" to 8\" |
| 59 | Gland Leakage>8\" to 12\" |
| 60 | Bonnet Leakage upto 2\" |
| 61 | Bonnet Leakage > 2\" to 4\" |
| 62 | Bonnet Leakage >4\" to 8\" |
| 63 | Bonnet Leakage >8\" to 12\" |
| 64 | Replt BFP MechSeals |
| 65 | Replt BFP Thrust Bearing |
| 66 | Inspection/ Adjustment/ Replt BFP BRG |
| 67 | Replt Blr Feed PP |
| 68 | Clng Oil Filters Blr Feed PP |
| 69 | Clng Lube Oil Coolers Blr Feed PP |
| 70 | Oil topping in Blr Feed PP |
| 71 | Alignment Blr Feed PP with mtr |
| 72 | Replt Oil Seal Labyrinth of BFP |
| 73 | Clng Blr Feed PP Oil Tank |
| 74 | Rpr & Servicing AOP BFP |
| 75 | Rpr & Servicing MOP BFP |
| 76 | Clng Suction v/v Strainer BFP |
| 77 | Up to 2” |
| 78 | >2” to 4” |
| 79 | >4” to 8” |
| 80 | >8” to 12” |
| 81 | ARC OF WHRU for 2nd year |
| 82 | O/H Diverter Damper seal Air Fan |
| 83 | Attending Gland Leakage in Chemical PP |
| 84 | Preparation HRSG Annual Hydraulic Test |
| 85 | Manhole opening / closing of HRSG |
| 86 | Blr Drum Manhole opening / closing of HR |
| 87 | HRSG Tube leakage |
| 88 | Attending Header Leakage |
| 89 | Clng CBD & IBD Tank |
| 90 | Clng Deaerator Strainer |
| 91 | Servicing Deaerator Spray Device |
| 92 | Servicing/ Replt Eco-SRV |
| 93 | Servicing / Replt of valve upto 2\" |
| 94 | Servicing / Replt of valve > 2\"to4\" |
| 95 | Servicing / Replt of valve >4 to 8\" |
| 96 | Servicing / Replt of valve > 8\"to 12\" |
| 97 | Servicing turbine barring gear |
| 98 | Servicing servomtr turbine contrl v/v |
| 99 | Servicing servomtr ESV of turbine |
| 100 | Replt turbine exhaust diaphragm |
| 101 | Hydraulic Oil filter Cleaning/Replt |
| 102 | Clng Main oil tank turbine |
| 103 | Replacing Lub Oil filter Cartridges ST |
| 104 | Cleaning of Lube Oil Cooler |
| 105 | Preventive maintenance of Oil Purifire |
| 106 | Servicing booster PP |
| 107 | Attending leakage ejector shell flange |
| 108 | Attending leakge flange/line water/steam |
| 109 | Clng condenser Hotwell |
| 110 | Ser of Cond Butterfly valve GB |
| 111 | Back Washing of Half Condenser |
| 112 | Fill Test of Condenser |
| 113 | Replt rubber expansion below stean cond |
| 114 | Clng condensate Extraction PP suction |
| 115 | Clng generator air cooler tubes |
| 116 | Decoupling/Coupling of Pump |
| 117 | Preventive Mtc of LLVT Dtain Pump |
| 118 | Replt of BRG |
| 119 | Replt/ servicing mechanical seal |
| 120 | Servicing/Replt of Jacking oil Pump |
| 121 | Preventive Mtc of CEP |
| 122 | Changing BRG |
| 123 | Replt/ servicing mechanical seal |
| 124 | Preventive maintenance of Gland steam ex |
| 125 | Oil topping in main oil tank |
| 126 | Greasing upto 2\" |
| 127 | Greasing > 2\" to 4\" |
| 128 | Greasing > 4\" to 8\" |
| 129 | Greasing > 8\" to 12\" |
| 130 | Welding of Joints upto 2\" |
| 131 | Welding of Joints > 2\" to 4\" |
| 132 | Welding of Joints > 4\" to 8\" |
| 133 | Welding of Joints > 8\" to 12\" |
| 134 | Removal of AOP/EOP |
| 135 | Installation of AOP/EOP |
| 136 | Gland Leakage upto 2\" |
| 137 | Gland Leakage>2\" to 4\" |
| 138 | Gland Leakage>4\" to 8\" |
| 139 | Gland Leakage>8\" to 12\" |
| 140 | Bonnet Leakage upto 2\" |
| 141 | Bonnet Leakage > 2\" to 4\" |
| 142 | Bonnet Leakage >4\" to 8\" |
| 143 | Bonnet Leakage >8\" to 12\" |
| 144 | Replt BFP MechSeals |
| 145 | Replt BFP Thrust Bearing |
| 146 | Inspection/ Adjustment/ Replt BFP BRG |
| 147 | Replt Blr Feed PP |
| 148 | Clng Oil Filters Blr Feed PP |
| 149 | Clng Lube Oil Coolers Blr Feed PP |
| 150 | Oil topping in Blr Feed PP |
| 151 | Alignment Blr Feed PP with mtr |
| 152 | Replt Oil Seal Labyrinth of BFP |
| 153 | Clng Blr Feed PP Oil Tank |
| 154 | Rpr & Servicing AOP BFP |
| 155 | Rpr & Servicing MOP BFP |
| 156 | Clng Suction v/v Strainer BFP |
| 157 | Up to 2” |
| 158 | >2” to 4” |
| 159 | >4” to 8” |
| 160 | >8” to 12” |