Visakhapatnam Port Trust has published Tender For Providing Of Facade Lighting To The Wall Paintings Along Grade Separation Bridge Wall To Aob Jn Via Fire Station Road Including Strengthening Of Existing Incoming Power Supply Cables To Cater The Additional Loads. Submission Date for this Tender is 18-04-2024. Electrification Work Tenders in Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply of 3 ½C x 50 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed, PVC overall sheathed, armoured, multi stranded Alluminiumconductor cable of approved brand conforming to IS 7098/I. Makes: Torent / Universal / Unicab / Havells / Gloster/ Polycab |
2 | Supply of 3 ½C x 25 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed, PVC overall sheathed, armoured, multi stranded Alluminiumconductor cable of approved brand conforming to IS 7098/I. Makes: Torent / Universal / Unicab / Havells / Gloster/ Polycab |
3 | Supply of 4C X 6 Sq mm 1.1 KV grade XLPE insulated & PVC sheathed, unarmoured, PVC overall sheathed multi stranded copper conductor Cable , in existing trench/to the pole with existing clamps / through pipe Make: Torrent / Universal / Unicab / Havells / KEI / KSP / Polycab / Gloster |
4 | Supply laying of 3C X 1.5 Sq.mm 1.1 KV grade XLPE insulated & PVC sheathed, armoured PVC overall sheathed multi stranded copper conductor Cable confg.to IS1554 from existing street lighting /to the FRP box in existing pole MAKES CABLE:Universal / Unicab / Havells / Polycab / Gloster / Finecab / Finolex. |
5 | Laying / clamping / drawing and connecting 4C x 6/25/50 Sq.mm cable 1.1 KV grade XLPE insulated & PVC sheathed, PVC overall sheathed, armoured, multi stranded Alluminium / copper conductor cable. In the existing trench through the existing pipe / to the pole including termination with suitable lugs complete as directed by Engineer-in-charge including all labour, tools and tackles. (Cable will be supplied by VPA) |
6 | Supply & Laying of 75 mm dia PE 80 grade10Kg/cm2 HDPE pipe in the existing trench with all materials labour tools and tackles as directed by Engineer in charge.Make: Sudhakar / KSP / Tulasi |
7 | Supply & Laying of 40/50 mm dia PE 80 grade10Kg/cm2 HDPE pipe in the existing trench with all materials labour tools and tackles as directed by Engineer in charge.Make: Sudhakar / KSP / Tulasi |
8 | Supply fabrication and fixing of suitable bracket to fix LED flood light50 mm dia, Heavy gradeG.I Pipeto the column or to the pole with all materials, nut & bolts labour tools and tackles as directed by Engineer in charge.Make: Tata or Zenith make or equivalent. |
9 | Supply of 150 watts LED flood light fittings warm white light surface / pole mounting extended pressure die cast aluminium enclosure IP65 protection input voltage:100-277V AC, 50Hz frequency LED efficiency of > 120 Lumens/watt with beam angle of >120 degrees with 03 years warranty. Make: Crompton / Bajaj / Havells / Halonix / Philips / GE / Wipro / Syska / KSP/K-Lite |
10 | Fixing, connection and commissioning of 150 watts LED flood light fittings warm white light on the wall / to the pole / enclosure box complete with all accessories as directed by Engineer in charge including all labour, tools & tackles (LED flood light fittings will be supplied by VPT at free of cost) |
11 | Supply & Fixing of 210 x 155 x 92 mm(approx.) thermo plastic cable junction box with IP 66/67weather proofprotection with knockouts for cable entry including terminal block of 16A/500V hinged door and locking arrangement as directed by Engr I/c complete with all materials,cable termination, labour tools and tackles. Make: Hensel/ELM/Sintex or any approved |
12 | Providing, earth station using 3.0 meters long, 40 mm medium grade G.I. pipe in a masonry enclosure duly filling with alternate 26layers of salt and charcoal complete with GI funnel and covering with RCC cover conforming to IS as directed by Engineer in charge including all labour and material. |
13 | Supply and laying 25 mm X 6 mm G.I strip as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as directed by engineer in charge |
14 | Supply, fixing connecting and commissioning of LT 3 phase and neutral, floor mounted, outdoor type Double door feeder pillar panel of size 1.0mtr. x 1.0 mtr x 0.6 mtr.(approx), made of 14 SWG sheet steel, with dust and various proof IP 55 protection with 2 coats ofapproved shade of enamel paint over one coat of red-oxide, thickness of 14 SWG comprising of following switch gear and metering devices of approved brands with suitable bus bar arrangement for 3 phase and neutral (200A rating for each phase and 100A for neutral) complete as directed by Engineer in charge including all labour tools and material. 1) Incomer: 4 pole 415 V, 35/36 KA, 250A, MCCB changeover switch with Thermostatic setting- 1 No 2) Incomer: 4 pole 415 V, 35/36 KA, 250A, MCCBwith Thermostatic setting- 2 Nos 2)Out goings: 1 pole, 415V, 16 KA 63A, MCCB-12Nos 3a) Panel mountedDigital Voltmeter, Ammeter 3b) LED pilot lamps 230V, 5 Nos SWITCH GEAR BRANDS : ABB/SIEMENS/ HAVELLS/ L&T / C&S/ GE/ |
15 | Excavation of Trenches of required width for laying of GI pipes, cables etc., including dressing of sides, ramming of bottoms, suitable depth including getting out the excavated soil and the returning the soil including consolidatingdepositinglayer as directed by Engineer in charge with all labour tools and tackles Hard / Dense soil |
16 | Breaking of PCC and removing of debris as directed by Engineer in charge including all labour tools and tackles |
17 | Supply and providing of P.C.C. 1:3:6 with 20 mm graded granite as coarse aggregate and river sand as fine aggregate (220 Kgs of cement per M3 of finished concrete) including mixing, depositing in position, tamping, finishing and curing for base concreting, road cutting etc. as directed by Engineer in charge including all labour and tools |
18 | Supply and fabrication of steel by using suitable flats, angles, heavy gauge mesh, sheets, channels of required sizes to provide suitable enclosure box with stand to safe guard flood light fitting, back clamps, including cutting, bolting, riveting, drilling, welding etc. including providing one coat of zinc rich epoxy paint primer and high quality enamel paint finish coat complete as directed by Engineer in charge |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy