}

Provision Of Lightening Protection, Ac, Fire Fighting, Shed For Dg Set And Allied Electrical And Mechanical And B/R Work Services For Equipment Room And Radar Room For Ssr Tower At Shaheed Dweep (Neil Island) Under Ge (P) Central Port Blair, South Andamans-Andaman And Nicobar Islands

Military Engineer Services-MES has published Provision Of Lightening Protection, Ac, Fire Fighting, Shed For Dg Set And Allied Electrical And Mechanical And B/R Work Services For Equipment Room And Radar Room For Ssr Tower At Shaheed Dweep (Neil Island) Under Ge (P) Central Port Blair. Submission Date for this Tender is 20-04-2024. Paver Blocking Tenders in South Andamans Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

43044235
Corrigendum : Provision Of Lightening Protection, Ac, Fire Fighting, Shed For Dg Set And Allied Electrical And Mechanical And B/R Work Services For Equipment Room And Radar Room For Ssr Tower At Shaheed Dweep (Neil Island) Under Ge (P) Central Port Blair
Open Tender
Indian
Andaman And Nicobar Islands
South Andamans
20-04-2024

Tender Details

Provision Of Lightening Protection, Ac, Fire Fighting, Shed For Dg Set And Allied Electrical And Mechanical And B / R Work Services For Equipment Room And Radar Room For Ssr Tower At Shaheed Dweep ( Neil Island ) Under Ge ( P ) Central Port Blair- 1 Excavation In Trenches Nexc 1.5M Deep & 1.5M Wide And Getting Out In Soft Loose Soil 2 M&L For Pcc 1:4:8 Type D2 Using 40Mm Graded Stone Aggs As In Fdn Filling And Mass Concrete Sub Base Etc, Complete All As Specified And Directed. 3 M&L For Rcc M-30 Design Mix As In Foundation Including Rafts Footing, Basement Of Slab And Mass Conrete Etc Complete All As Specified And Directed. 4 M&L For Rcc M-30 Design Mix As Inretaining Wall Of Any Thicknessetc Complete All As Specified And Directed. 5 M&L For Use And Waste Of Form Work To Sides Of Concrete Foundation, Footing, Base Of Columns Rafts And Raft Beams Sides And Soffits ( If Any ) Of Foundation And Plinth Beams And Similar Work Verticale Or To Bater, Fair Finished Surfaces Of Concrete Complete All As Specified And Directed. 6 M&L For Use And Waste Of Form Work Toface Of Wall, Sides Of Retining Wall And Similar Work, Fair Finished Surfaces Of Concrete Flat Complete All As Specified And Directed. 7 S & F Mild Steel Tmt Bars 10Mm Dia, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 8 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated / Semicorrugated Sheet 0.50Mm Thick As Per Approved Profile, Coloured, Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws All As Specified And Directed 9 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Of Any Colour Having Tensile Strength Of 550Mpa As In Ridges / Framed Semi Circular Or Purpose Made Gutters Etc Complete Fixed With Self Tapping Screws Allas Specified And Directed At Site . 10 S & F Ms Steel Work In Roof Trusses ( Framed ) , Trussed, Purlins, Cranegantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc, Grade Fe-410- W ( GdeE-250 ) QualityB Including Notching, Drilling, Fitting, Riveting And / Or Welding Or Connecting With Bed Plate, Bolt And Nuts Complete All As Specified And As Directed 11 M&L For Mild Steel Work As Inwind Ties, Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required Hooks ( Stay ) , Heavy, For Large Gates, Hook And Pintle Hinges, Large Hasps And Staples, Chains, Hand Made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks Forhanging Fans, Plain Angle Cleats For Securing Purlins To Woodtrusses Or Rafters; Knee Pieceinserts, Two Way And Three Waystraps, Plate Washers And Similar Small Articles Conforming To Fe-290 Gde-E-165 Complete All As Specified And Directed. 12 M & L For Preparing To New Steel / Iron Surfaces Of Any Description Exc 10Cm Width Or Girth And Applying Two Coats Of Synthatic Enamel Paint Over One Coat Of Red Oxide Primer Complete All Specifiedcand Directed. 13 S&F 110 Mm Bore Pvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls Etc As Rain Water Pipes Complete All As Directed And Specified . 14 S&F 110 Mm Bore Pvc ( Swr ) Bends Any Radius Complete All As Specified And Direcded. 15 S&F Pvc ( Swr ) 100 Mm Pipes Single Socketed, In Any Length With Rubber Ring Joints Fixed On Walls As In Weep Holes Complete All As Specified And Direcded. 16 Returning Fillling In Including Spreading, Levelling, Watering And Well Ramming In Layers N Exc 25 Cm Thick In Hard Dense Soil Complete All As Specified And Directed. 17 Removal Of Surplussoil To A Distance Not Exc 50 Mtrs Anddepositing Where Directed At A Level N.Exc 1.5 Mtrs Above The Starting Point Complete All As Specified. 18 M&L For Approved Earthfilling Under Floorsbrought By Excavation From Near By Areas Lead Exc 500M But Nexc 1.0 Kmincl Watering And Well Ramming All As Directed. 19 M&L For Pre-Cast Cement Concrete Block Masonrywith Solid Blocks With 1:2:4 Mix, Exc. 10 Cm In Width And Setting In Cement Mortar1:4Complete All As Specified And Directed. 20 M&L For Pcc 1:2:4 Type B1 Using 20Mm Garded Stone Agg As In Coping Complete All As Specified And Directed . 21 M&L For 10Mm Thick Rendering In Cm 1:4 Finished Even And Smooth Using Extra Cement Complete All As Specified And Directed. 22 M&L For Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Agg As In Beds To Ductsetc Complete All As Specified And Directed. 23 M&L For Hardcore Of Guage Nexc 63Mm But N Exc. 100 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rolled / Rammed To A True Surface Complete All As Specified And Direcded. 24 M&L For 100 Mm Thick Pcc 1:2:4 Type B2 Using 40 Mm Graded Stone Agg As In Flooring Laid In Alternate Bays Complete All As Directed. 25 M&L For Drilling Holes In Pcc / Metallic Platesand Fixing 8 Mm Dia Metallic Fastners Incl Epoxy Grout For Securing Machinesetc All As Directed And Specified. 26 M&L For Anodised Aluminium Frame Work Using Anodised Aluminium Angles, Flats Ans Chequerred / Plain Aluminium Plates Incl Cutting To Shape And Jointingcomplete As In Foundation Work Of Machines, Radar Equipments. 27 S&F 8 Mm Dia Gi Wire Winch Cable Of Approved Pattern And Fixing To Hoist Tower Incl Clamping Etc And Nut Bolts Complete All As Directed 28 M&L For Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Including Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm ) , Including Making Drainage Opening Wherever Required Complete. 29 M&L For Providing And Laying 80 Mm Thickfactory Made Chamfered Edge M-30 Grade Cement Concrete Paver Block With Approved Colour, Design & Pattern As In Roads And Pavings Parking Etc. Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mmthick Compacted Bed Of Coarse Sand, Compacting And Proper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Fine Sand And Cutting Of Paver Block As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete. 30 Material And Labour For Air Termination, Single Pointed Aluminium Rod 12 Mm Dia 12 Mm Dia And 300 Mm Long. 31 Material And Labour Fortest Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75X75x25 Mm Drilled And Scued Incl 03 Nos 8 Mm Dia 25Mm Long Hex Head Screw. 32 Material And Labour For Aluminium Strip 25X3.15Mm With Saddles And Fixing Insulators At A Distance Of Half Meter Each, Screw Etc For Roof Conductors And Down Conductors Above Ground. 33 Material And Labour For Copper Strip 20X3.15 Mm With Saddles And Fixing Screw, Isulators At A Distance Of Half Meter Etc For Roof Conductors And Down Conductors Above Ground. 34 Supply & Fixing Sub Main Wiringfor Security Light Fittingwith Two Runs Of Single Core 4Sqmm Pvc Insulated , Unshethedmultistrandered Copper Conductor 1100 Volt Frls Cable , Including One Run Of 4 Sqmm Single Corepvc Insulated Unshetheredmultistranded Copper Comnductor 1100 Volts Frls Cable ( Make Poly Cabe / Havells / Finolex ) Earth Continiuty Conductor Drawn Through Pvc Conduit Pipe ( Make - Precision / Modi ) And Connecting To Common Earth Dolly For Sintax Boxcomplete All Specified And As Directed .Note :-Two Run Of Main Cable , One Run Of Earth Continuty Conductor Cable And One Run Of Medium Casing Capingwill Be Measured As One Unit For Payment Purpose . 35 Supply And Fix Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb 20 Amps. 36 Supply And Fix Mcb Db Spn 8 Wayd / Door, Ip54 Isolater Neutral Bar, Cement Spill Protector, Upto 250 A Completeall As Specified And Directed. Complete All As Specified And Directed. 37 Supply And Fix Mcb Db Tpn 4 Wayd / Door, Ip54 Isolater Neutral Bar, Cement Spill Protector, Mis Ik09 Suitable For Mccbs Upto 250 A Completeall As Specified And Directed. Complete All As Specified And Directed. 38 Supply And Fix On Load Change Over Switch 415 V In Sheet Metal Enclosers 4 Pole Of Capacity 100 Amps. 39 Material & Labour For Earthing Complete With Gi Earth Plate Electrode Of Size 60Cm X 60Cm X6 Mm Thick Burried Directly In Ground Vertically At A Depth Not Less Than 2.25 Mtr Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Mtr Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick And Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Gi Strip Of Size 32X6 Mm Means Of Bolts, Nuts, Check Nuts And Washers Made Of Gi And Protected By Medium Grade 40Mm Dia Galvanised Ironpipe Connected To Main Switch Board Or Main Control Board And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel, Wire Mesh, Rcc Pit Cover And Pcc Chamber Pit With Pcc 1:2:4 Type B-1 ( Including Necessary Excavation And Earth Work Disposal Of Surplus Soil To A Distance Not Exceeding 50 Mtr All As Specified And Shown On Plate No 3 Of Ssr Part-I 2009.Note : ( I ) The Unit Rate Shall Include For Earth Work And Protection Of Gipipe, Gi Water Pipe, Wire Mesh, Funnel, Excavation, Rcc Pit Cover, P.C.C Chamber Pit, . Test Point, 32X6mm Gi Strip Fromtop Of Earth Plate Upto 5 Metres Above Ground Level. ( Ii ) Pcc Pit Shall Be Provided At Least 500Mm Away From The Earth Pit And Not Just On The Earth Pit And Extra Cost Of Additional Length Of Water Pipes And Fitting Junctionetc Shall Be Deemed To Be Included In The Unit Rate. 40 Material & Labour For Earthing Complete With Gi Earth Plate Electrode Of Size 60Cm X 60Cm X 6 Mm Thick Burried Directly In Ground Vertically At A Depth Not Less Than 2.25 Mtr Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Mtr Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick And Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Gi Wire Of Size 4 Mm Dia Means Of Bolts, Nuts, Check Nuts And Washers Made Of Gi And Protected By Medium Grade 40Mm Dia Galvanised Ironpipe Connected To Main Switch Board Or Main Control Board And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel, Wire Mesh, Rcc Pit Cover And Pcc Chamber Pit With Pcc 1:2:4 Type B-1 ( Including Necessary Excavation And Earth Work Disposal Of Surplus Soil To A Distance Not Exceeding 50 Mtr All As Specified And Shown On Plate No 3 Of Ssr Part-I 2009.Note : ( I ) The Unit Rate Shall Include For Earth Work And Protection Of Gipipe, Gi Water Pipe, Wire Mesh, Funnel, Excavation, Rcc Pit Cover, P.C.C Chamber Pit, . Test Point, 4Mm Dia Gi Wire Fromtop Of Earth Plate Upto 5 Metres Above Ground Level. ( Ii ) Pcc Pit Shall Be Provided At Least 500Mm Away From The Earth Pit And Not Just On The Earth Pit And Extra Cost Of Additional Length Of Water Pipes And Fitting Junctionetc Shall Be Deemed To Be Included In The Unit Rate. 41 Material & Labour For Earthing Complete With Copper Plate Electrode Of Size 60Cm X 60Cm X 3.15 Mm Thick Burried Directly In Ground Vertically At A Depth Not Less Than 2.25 Mtr Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Mtr Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick And Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Copper Strips Of Size 20X3 Mm Means Of Bolts, Nuts, Check Nuts And Washers Made Of Gi And Protected By Medium Grade 40Mm Dia Galvanised Ironpipe Connected To Main Switch Board Or Main Control Board And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel, Wire Mesh, Rcc Pit Cover And Pcc Chamber Pit With Pcc 1:2:4 Type B-1 ( Including Necessary Excavation And Earth Work Disposal Of Surplus Soil To A Distance Not Exceeding 50 Mtr All As Specified And Shown On Plate No 3 Of Ssr Part-I 2009.Note : ( I ) The Unit Rate Shall Include For Earth Work And Protection Of Gipipe, Gi Water Pipe, Wire Mesh, Funnel, Excavation, Rcc Pit Cover, P.C.C Chamber Pit, . Test Point, 20X3mm Copper Strip Fromtop Of Earth Plate Upto 5 Metres Above Ground Level. ( Ii ) Pcc Pit Shall Be Provided At Least 500Mm Away From The Earth Pit And Not Just On The Earth Pit And Extra Cost Of Additional Length Of Water Pipes And Fitting Junctionetc Shall Be Deemed To Be Included In The Unit Rate. 42 Supply And Layingxlpe Insulated Heavy Dutyscreened Pvc Bedded, Galvanized Steel Strip Or Wire Armored, Electric Power Cables 1100 Volts Grade With Stranded Aluminum Conductor Confirming To Is 7098 All As Specified Of Size 10 Sqmm 4 Core 43 Supply And Layingxlpe Insulated Heavy Dutyscreened Pvc Bedded, Galvanized Steel Strip Or Wire Armored, Electric Power Cables 1100 Volts Grade With Stranded Aluminum Conductor Confirming To Is 7098 All As Specified Of Size 50 Sqmm 3.5 Core 44 Supply And Fix Led Aviation Light Of 5 Watt Capacity Of Input Voltage 230 Volt. 45 Supply And Fix Gi Pipe Light Grade For Cable Protection Of Size 40 Mm Dia 46 Supply, Laying & Fixing In Trenches Double Wall Corrugated ( Dwc ) Pipes Made Of High Density Polyethylene ( Hdpe ) With All Accessories I.E All Type Of Joints, Sockets, Elbows, Bends & End Caps Etc. Complete Of Internal Dia 50 Mm. 47 Supply And Fix Fire Extinguiser Co2 Type, Cap-03 Kg Isi Marked Including Clamp For Fixing On Wall. 48 Supply And Fix Fire Extinguiser Abc Type, Cap-06 Kg Isi Marked Including Clamp For Fixing On Wall. 49 Supply And Layingxlpe Insulated Heavy Dutyscreened Pvc Bedded, Galvanized Steel Strip Or Wire Armored, Electric Power Cables 1100 Volts Grade With Stranded Aluminum Conductor Confirming To Is 7098 All As Specifiedof Size 4 Sqmm 4 Core. 50 Supply & Fix Fire Alarm Control Panel Having Audio And Visual Type Signal Complying With Bs En 54, Single Loop Panel Of Capacity From 99 Detector 99 Module And Up To 200 Detector And 200 Module Per Loop. 51 Suply & Fix Fire Alarm Siren / Sounder Electronic Type Horizontal Single Stage Continuies Normal Operation For At Least 50 Minutes With Sound Level 65 Db To 120 Db Measured At 1.5 M With Sound Output Variation Of +5 Db 500 M Range 52 Supply & Fix Detector Complying With Any Type Certified En 45 Addresible Type Smoke Detector With Heat & Smoke Combination With Self Built Intelligence As Per Is 11360. 53 Supply & Fix Remote Response Indicators For Fire Alarm System 54 Supply & Fix Manual Addressablecall Pointbreak Glass Type With Alarm Led Complete 55 Material And Labour For Submain Wiring For Gate Light With Four Runs Of 2.5 Sqmm And One Run Of 2.5 Sqmm As Earth Continuity Conductor 1100 V Grade Pvc Insulated Unsheathed Frls Grade Copper Conductor Cable Single Core Multistranded Isi Marked ( Is-694 ) In Steel Conduits Including Accessories Such As Bends, Supports Etccomplete All As Specified And As Directed.Note :- 4 Runs Of 2.5Sqmm Cable And 1 Run Of 2.5Sqmm Earth Cable And One Run Of Pvc Conduit Along With Accessories Will Be Measured As One Unit. 56 Supply And Install Room Windows Type Ac Electric Driven ( Single Phase ) Cooling Capacity 4500K Cal Per Hour ( 1.5 Ton ) Bee 5-Strar Rated With Cordless Remote Control Unit And With Inbuilt Air Ioniser And Plasma Filter For Better Indoor Air Quality. 57 Supply And Fix Voltage Stabiliser For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type And Designed For Input Variation Between 170 To 250 Volt With Output Voltage Stabilized At 230 V With Accuracy Of + / - 2.5 % And Of Capacity 4 Kva.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Apr-2024 Revision of BOQ BOQ 13-04-2024
2 04-Apr-2024 Corrigendum 01 Other 13-04-2024
3 13-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 54620.0 /-
Tender Value
INR 27.31 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail