}

Tender For Repair/Maintenance Of Ac Plant And Dg Sets And Its Connected Items At Old Cantt Under Ge (East) Prayagraj., prayagraj-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Ac Plant And Dg Sets And Its Connected Items At Old Cantt Under Ge (East) Prayagraj.. Submission Date for this Tender is 04-05-2024. Electrical Maintenance Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43044214
Corrigendum : Tender For Repair/Maintenance Of Ac Plant And Dg Sets And Its Connected Items At Old Cantt Under Ge (East) Prayagraj.
Open Tender
Indian
Uttar Pradesh
prayagraj
04-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair / Maintenance Of Ac Plant And Dg Sets And Its Connected Items At Old Cantt Under Ge ( East ) Prayagraj.- 1 M&L For Checking The Leakage In Both Low And High Side Of The System By Feeding Dry Nitrogen Upto 300 Psi To Maintain Adequate Pressure In The System, Plugging The Leaks Including S&F In Replacement Of Teflon Sealing Of All Refrigerant Line Valves Like Liquid Lines Valves / Suction / Discharge Valves Of Compressors, Gland Packages Of All Angle Valves Flaring Of All Connections Framing Welding Etc Complete For Ac Plant Of Capacity 3X11tr-Plant For For Signal Centre, Complete All As Specified And Directed By Engr-In-Charge. 2 All As Per Srl Item No.1 Here-In-Before But For Ac Plant Of Capacity 2X25tr-Plant For 804 Fd Workshop, Complete All As Specified And Directed By Engr-In-Charge. 3 M&L For Opening The Upper Sheet And Side Sheet Of Ahu For Access To Cooling Coil Including For Washing / Cleaning Of Cooling Coil Externally With Mild Acid ( Or Caustic Soda Hot Water Solution ) Followed By Water Jet Including Cleaning / Washing Of Air Filters And Re-Fixing And Changing Of V Belt Both Set With Necessary Fitting And T&P For Mounting For Ac Plant Of Capacity 3X11tr-Plant For For Signal Centre , Complete All As Specified And Directed By Engr-In-Charge. 4 All As Per Srl Item No. 3 Here-In-Before But For Ac Plant Of Capacity 2X25tr-Plant For 804 Fd Workshop, Complete All As Specified And Directed By Engr-In-Charge. 5 M&Lpcbpackage Ac Plant Of Capacity 11 Tr Includingin Replacement Ofnut, Bolt And Other Packing Material Etc; Checking The Proper Electric Connection, Testing And Commissioning For Smooth Operation At Optimum Efficiency For 804 Fd Workshop, Complete All As Specified And Directed By Engr-In-Charge. 6 Taking Out The Existing Unserviceable The Item Of Package Type Ac Plant Of Capacity 3X11 Tr Capacity, Item Including Cooling Coil , Air Filters, Plasma Filters Etc ( Indoor Uint ) , Condenser, Condenser , Fan Motor Etc Electrical / Electonic Circuits Relays, Wiring Kit, Thermostats, Swiches, Knobs, Remort Control Unit, Including Pcb , Fan Blower And Refixing The Samein Ex Position Complete After Replacement Wiht Supply Only Material From Item No 7 To 17 All As Specified And Directed 7 Supply And Fixingcooling Coil Of Any Size And Rows Suitable For 11 Tr 8 Supply And Fixingof Indoor Air Blower Motor 11 Tr Capacity Complete All As Specified And Directed. 9 Supply And Fixing Cooper Wounded Condensor Fan Motor Packege Type Ac Of 11 Tr Capacity Out Door Unit Complete All As Specified And Directed. 10 Disconnecting The Mains And Taking Out The Unsv Condensor Coil Of Packege Type Ac Capacity Of 11 Tr Any Make Form Any Location And Supply Fixing And Testing New Condenser Coil As Per Exiting Size And Patterns For Complete All As Specified And Directed. 11 S&F Condensor Fan Blade Of Alluminium For Package Type Acof Capacity 11 Tras Per Existing Size As Specified And Directed 12 S & F In Repair Ofexpansion Valve For Package Type Ac Of Capacity Of 11 Tr Complete All As Specified And Directed By Engr-In-Charge. Make :- Danfos / Emerson / Temsuch 13 S&F For Thermostate Of Package Type Ac Capacity Of 11 Tr All As Per Existing, Complete All As Specified And Directed By Engr-In-Charge 14 S&F In Replacement Of Suction Valve Set Of Suitable Size For Package Type Ac Capacity 11 Tr All As Specified And Directed By Engr-In-Charge ( Note:- Supply And Filling Of Refigerant Gas Shall Be Measured And Paid Under Relevent Items ) 15 S&F In Replacement Of Discharge Valve Set Of Suitable Size For Package Type Ac Capacity Of 11 Tr All As Specified And Directed By Engr-In-Charge. Make :- Lg / Voltas / Blue Star / Hittachi 16 S&F For Cooling Coil Package Type Ac Capacity 11 Tr Including Cheking Leakingwelding Andother Packing Material Etc, Testing And Commissioning For Smooth Operationcomplete All As Specified And Directed By Engr-In-Charge. 17 Removing Burnt / Defective Sealed Compressor Unit Of Any Make From Any Type Of Package Type Accapacity 11 Tr By Cutting Of Suction And Discharge Lines Unscrewing The Foundation Nuts, Bolts Etc, Supply And Fixing Of New Sealed Compressor Unit Of Suitable Make As Existing By Connecting Suction And Discharge Lines With Gas Welding / Brazing Work And Tightening Foundation Nuts & Bolts Etc All As Directed 18 Removing Burnt / Defective Sealed Compressor Unit Of Any Make From Any Type Of Central Type Ac Plant Capacity 12.5 Tr By Cutting Of Suction And Discharge Lines Unscrewing The Foundation Nuts, Bolts Etc, Supply And Fixing Of New Sealed Compressor Scrol Type Unit Of Suitable Make As Existing By Connecting Suction And Discharge Lines With Gas Welding / Brazing Work And Tightening Foundation Nuts & Bolts Etc All As Directed 19 M&L For Dismantling Of Electric Driven Horizontal Induction Motor Of Capacity 10 / 12.5 Hp Of Any Type And Make, By Engaging Sufficient Man Power And Suitable T&P To Ensure Safety Of Motor Including Disconnecting Of Electric Connections, Dismantling Of Motor, Taking Out The Burnt Windings, Cleaning And Washing Of Slots And Rewinding The Same With Copper Winding Wire Of Existing Gauge And Quantity ( As Per Original Manufacturer Design ) Including Replacement Of All Damaged Parts I. E. Bearings, Bush, Thrust Plate, Thrust Bearing, Connector Plate, Insulating Materials Such As Insulating Sheets Insulating Paper ( Class F ) , Sealing Compounds Etc And Reassembling The Motor After Varnishing, Heating / Drying, Greasing Of Moving Parts Etc And Reinstallation Of The Motor In Original Location, Checking The Alignment, Making Proper Electric Connection, Testing For Smooth Operation, Complete All As Directed.Note : ( I ) The Cost Of Winding Wire And All Replaced Defective Parts Are Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor In This Effect. ( Ii ) Thecost Of Transportation ( To And Fro ) And Other Necessary Equipment Shall Be Arranged / Brought By Contractor To Complete The Job At Site Or At Repair Shop And No Extra Cost Shall Be Paid To The Contractor In This Effect. 20 All As Per Srl Item No 19 Here-In-Above But For 5 / 7.5 Hp Capacity. 21 All As Per Srl Item No 19 Here-In-Above But For 3 / 2 Hp Capacity. 22 M&L For Complete Overhauling Of Condenser / Chiller Centrifugal Pumpset Of 10 / 12.5 Hp By Engaging Sufficient Man Power And Suitable T&P To Ensure Safety Of Pump-Motor As Well As Working Persons Including Disconnecting Suction & Discharge Water Lines And Removing Of Electric Connection, Dismantling The U / S Pumpset From Ms Foundation, Detaching The Pump, Opening The Pump, Remelting The Shaft And Filling Of Metal At Decayed Portions Including All Kind Of Machine Works I.E. Welding, Turning, Polishing Etc As Required To Make The Shaft Of Required Shape And Size, As Original, Balancing The Shaft And Refitting In Pump Body Complete Incl Carrying Out Complete Repair / Replacement Of Damaged Parts I.E. Bearings, Bush, Gland Plate, Gland Packing, Coupling Assembly Etc And Reassembling The Pump After Greasing Of Moving Parts And Reinstallation Of The Pump With Motor In Original Location Using New Ms Stud, Nut, Bolt, Washer And Other Packing Material Etc; Checking The Alignment; Reconnecting The Suction And Delivery Pipes, Making Proper Electric Connection, Testing And Commissioning For Smooth Operation At Optimum Efficiency, Complete All As Directed. 23 All As Per Srl Item No 22 Here-In-Above But For 5 / 7.5 Hp Capacity. 24 All As Per Srl Item No 22 Here-In-Above But For 3 / 2 Hp Capacity. 25 M&L In Replacement Y-Type Strainer Flanged Type As Per Existing 50 / 80Mm Dia, Complete All As Specified And Directed By Engineer-In-Charge.Make : Zoloto / Leader / Zenith / Crescent 26 M&L In Replacement Sluice Valve Flanged Type As Per Existing 50 / 80Mm Dia, Complete All As Specified And Directed By Engineer-In-Charge.Make : Zoloto / Leader / Zenith / Crescent 27 M&L In Replacement Sluice Valve Flanged Type As Per Existing 100 Mm Dia, Complete All As Specified And Directed By Engineer-In-Charge.Make : Zoloto / Leader / Zenith / Crescent 28 M&L In Replacement Nrv Flanged Type As Per Existing 50 / 80Mm Dia, Complete All As Specified And Directed By Engineer-In-Charge.Make : Zoloto / Leader / Zenith / Crescent 29 M&L For Cleaning Of All Condensor Tubes Of Central Ac Plant By Disconnecting The Condensors -02 Nos From The System, Cleaning By Descaling Pump Using Descaling Solution Of Make:-Maic / Hibird Or Hydrochloric Acid 20%, Cleaning The System Through Cooling Tower By Using Descaling Solution, Cleaning Condensor Tubes By Nylon Brushes & Mild Steel Rods Of Suitable Size, Renewal Of Suction Water Filter For 2X25 Tr Capacity Plant At Sce. Complete All As Specified And Directed By Engr-In-Charge. ( Note:- T&P Such As Pumps, Tube Etc & Descaling Solution Etc Shall Be Arranged By The Contractor At His Own Cost. ) 30 Taking Out Old Pvc / Hdpe Fins Cooling Tower, Cleaning Inside And Outside , Refixing Pvc / Hdpe Fins For Proper Cooling , Any Size Of Cooling Tower , Including Replacement Of Nozzel, Complete All Including Testing Complete All As Specified And Directed. 31 Quarterly Periodical, Preventive & Comprehensive Maintenance By Dis-Assembly, Repairing, Overhauling, Servicing & Testing Of Complete Inner Tank, Elements, Inlet And Out Let Pipe, Valves Of Hot Water Generator Installed At Ac Plantincluding Descaling, Replacement Of Gaskets Complete Incl Painting With Two Coat Of Heat Resistant Paint Of Smoke Grey Colour Complete. 32 S&F In Replacement, Of Three Phase Heating Element Capacity 30Kw ( Set Of 06 Nos ) Capacity, Isi Marked Of Existing Shape And Size Suitable For Hot Water Generator And Making Electric Connections And Taking Down Old Unserviceable Heating Elements, Complete All As Directed. Make : Daspass / Theata / Rapid Cool 33 M&Lof Indoor Type Lt Panel Board And Replacement Of Unserviceable Switch / Control Gears And Meters, Selector Switches, Indicator Lamps Etc Including Rewiring And Extension Of Incoming And Outgoing Cables By Opening Of Loops And Provisioning Of Cable Lugs / Thimbles As Required And Replacement Of Rusted Sheet Metal With Existing Size Ms Sheets By Necessary Arc / Gas Welding ( Approx Sheet 1 Sqmtrs ) Including Two Coats Of Synthetic Enamel Spray Painting Over A Coat Of Red Oxide Primer Both Inside And Outside Surfaces Of Panel Board Including Rewriting Of Identification For Controls, Complete All As Specified And Directed By Engineer - In - Charge.Note: Mccb, Contactors, Relay, Single Phase Preventer, Timer, Change Over, Indicator Lamp, Selector Switch, Ammeter, Voltmeter Etc Given Below Will Be Measured And Paid In Respective Items. 34 Supply Only Single Phase Preventer With Auto Switch . Type- Cat No 2.Bsp-2, Complete All As Specified And Directed By Engineer - In - Charge.Make- Bentex / Minilec 35 Supply Onlymccb ( Ac 415 V ) With Adjustable Thermal & Adjustable Magnetic Setting Four Pole 400 Amp 36 Ka, Complete All As Specified And Directed By Engineer - In - Charge.Make : Ge Or Equivalent C &S / Legrand 36 Supply Onlymccb ( Ac 415 V ) With Adjustable Thermal & Adjustable Magnetic Setting Four Pole 320 Amp 36 Ka, Complete All As Specified And Directed By Engineer - In - Charge.Make :Ge Or Equivalent C &S / Legrand 37 Supply Onlymccb Of Capacity , 250Amps , 04Pole , 415 V, 36 Ka Breaking Capacity With Fixed Thermal Magnetic Release, Complete All As Specified And Directed By Engineer - In - Charge.Make- Ge Or Equivalent C &S / Legrand 38 Supply Only Mccb 200 A, 4 Pole, 415 V, 36 Ka Breaking Capacity, With Fixed Thermal Magnetic Release, Complete All As Specified And Directed By Engineer - In - Charge. Make-Ge Or Equivalent C &S / Legrand 39 Supply Onlymccb 100 A, 3 Pole, 415 V, 35 Ka Breaking Capacity, With Fixed Thermal Magnetic Release, Complete All As Specified And Directed By Engineer - In - Charge. Make- Ge Or Equivalent C &S / Legrand 40 Supply Onlymoulded Case Circuit Breaker ( Mccb ) ( Ac 415 V ) With Adjustable Thermal & Adjustable Magnetic Setting Three Pole 63 Amp 25 Ka , Complete All As Specified And Directed By Engineer-In-Charge.Make : Ge Or Equivalent C &S / Legrand 41 Supply Onlymoulded Case Circuit Breaker ( Mccb ) ( Ac 415 V ) With Adjustable Thermal & Adjustable Magnetic Setting Three Pole 40 Amp 25 Ka , Complete All As Specified And Directed By Engineer-In-Charge.Make : Ge Or Equivalent C &S / Legrand 42 Supply Only Motor Protection Circuit Breaker Thermal Overload Relays Suitable For Ml Contactors Relay Range 10-16A, Complete All As Specified And Directed By Engineer-In-Charge. Make-Havells / L&T / Legrand 43 Supply Only Power Contactor 3 Pole Type Mnx 18 Ac 3 Rating 18 A With Auxiliary Contact 2 No + 2 Nc , Complete All As Specified And Directed By Engineer-In-Charge.Make- L&T / Legrand 44 Supply Only Power Contactor 3 Pole Type Mnx 70 Ac 3 Rating 70 A With Auxiliary Contact 2 No + 2 Nc , Complete All As Specified And Directed By Engineer-In-Charge. Make- L&T Cat Part No. St19002 Or Equivalent In Legrand 45 Supply Only Power Contactor 3 Pole Type 3 Ml Ac 3 Rating 40 A With Auxiliary Contact 2No + 2Nc, Complete All As Specified And Directed By Engineer-In-Charge. Make- L&T Cat Part No - Ss90721 Or Equivalent In Legrand 46 Supply Only Power Contactor 3 Pole Type Mnx 25 A Ac 3 Rating 25 A With Auxiliary Contact 2No + 2Nc, Complete All As Specified And Directed By Engineer-In-Charge. Make- L&Tcat Part No - Ss90921 Or Equivalent In Legrand 47 Supply Only Power Contactor 3 Pole Type 1.5 Ml Ac 3 Rating 25 A With Auxiliary Contact 2 No + 2 Nc, Cat No - Ss91851 Make- L&T / Legrand 48 Supply And Replacement Of Return Air Grill Aluminium With Powder Coated White Collers Of Any Sizecomplete All As Specified And Directed. 49 Supply And Replacement Of Supply Air Grill Ms Air Control Damperof Any Size Complete All As Specified And Directed. 50 S&F Fan Belt Suitable For Ahu Fan As Existing Type And Model Complete All As Specified And Directed 51 M&Lforscraping Down, Cleaning And Preparation Of Old Painted Surface, Applying One Coat Of Synthetic Enamelled Paintto Ac Installation Central Type Ac Plant 2X25 Tr All As Per Existing Colour Code Including Sign Writing As Directed. ( Ac Installation Comprising Of Compressor, Motor Condenser, Pipe Line, Panel Board, Valves, Ahu Cooling Tower, Chillar Pipe And Display Board ) Marking Direction Of Flow And Writing Sm Nos And Mes Nos Of Size Not Less Than One Inch Complete All As Specified And Directed. 52 M&Lforscraping Down, Cleaning And Preparation Of Old Painted Surface, Applying One Coat Of Synthetic Enamelled Paintto Ac Installation Pakage Type Ac Plant 3X11 Tr All As Per Existing Colour Code Including Sign Writing As Directed. ( Ac Installation Comprising Of Compressor, Motor Condenser, Pipe Line, Panel Board, Valves, Ahu Cooling Tower, Chillar Pipe And Display Board ) Marking Direction Of Flow And Writing Sm Nos And Mes Nos Of Size Not Less Than One Inch Complete All As Specified And Directed. 53 Supply &Fixingrotational Moulded ( 3 Layered As Per Is 12701 ) Polythylene Water Storage Tank Cylindrical Vertical With Closed Top Hoisted Capacity Upto 2000Ltrs Isi Marked With Valid Cmlno And Fixed In Positionall As Specified And Directed By Engr-In-Charge 54 S&F Sub Main Wiring With Two Single Core Pvc Insulated & Unsheathed Cable 6.0 Sqmm ( Nominal Area ) Frls Typemulti Stranded Copper Conductor Drawn In And Including Not Less Than 20Mm Dia Rigid Pvc Conduit Medium Grade Isi Marked Including All Conduit Accessories For Concealedwiring With And Including Cutting Chases And Making Good Of Disturbed Surfaces & Applying Finishes& Including 6 Sqmm Frls Typepvc Insulated Unsheathedcable Multistrandedcopper Conductor As Earth Wire Connected To Common Earth As Per Is Including Taking Down Existing Complete Wiring Complete All As Specified & Directed.Note :Note:- ( I ) Two Runs Of 6 Sq.Mm Copper Conductor, One Run Of 6 Sq.Mm Copper Earth Continuity Conductor And One Run Of Pvc Conduit And With Accessories Shall Be Measured As One Unit Length. ( Ii ) Extra Length Of Cable / Wire Required For Connection To Mcbs Shall Not Be Measured And The Rate Quoted Per Unit Shall Deemed To Be Inclusive Of The Same Accordingly. 55 M & L Sub Main Wiring Complete With 2 Runs Of 6 Sq.Mm Pvc Insulated And Unsheathed 1100V Grade Multistranded Frls Grade Copper Conductor Cable Drawn Through And Including Provision Of Pvc Casing / Caping 25Mm Dia And Connecting Terminal Ends To DbS Including Providing 1 Run Of 6 Sq.Mm Pvc Insulated Unsheathed Multistranded Frls Grade Copper Cable As Earth Continuity Conductor And Connecting To Common Earth Dolly And Making Good Disturbed Surfaces To Match With Existing, Complete All As Specified And Directed.Note:- ( I ) Two Runs Of 6 Sq.Mm Copper Conductor, One Run Of 6 Sq.Mm Copper Earth Continuity Conductor And One Run Of Pvc Casing / Caping Shall Be Measured As One Unit Length. ( Ii ) Extra Length Of Cable / Wire Required For Connection To Mcbs Shall Not Be Measured And The Rate Quoted Per Unit Shall Deemed To Be Inclusive Of The Same Accordingly. 56 M&L For Onsite Disconnection Of Servo Voltage Stablizer Of Capacity 25 Kva Three Phase Unbalanced Type From Load And Transporting To Factory And Testing, Replacement Of Transformer Oil Painting, Servicing And Replacement Of Worn Out Parts And Transportation Back Refixing In The Original Position And On Load Testing Complete All As Specified And Directred By Engr In Charge. ( Note Parts Will Be Measeured Separately ) 57 Supply Only Following Parts 58 Dimmer 59 Motor 10 Kg.Cm Torque Motor 60 Micro Switch 61 Potentiometers 62 Relays 63 Contactor 64 Sensing Trigger Transformer 65 Transformer Oil 66 Electronic Cards 67 Carbon Brush 68 Neon Indicators 69 Electro-Mechanical Time Switch To Accommodate In The Sheet Metal Enclosure Factory Made With Synthetic Enamel Paintingcomplete And Fixed To The Lt Poleswithfi Clamps Made Ofms Flat 40X6mm, 02 Nos With The Following Accessories And All As Directed :- ( I ) Timer Switch Maxi Rex 4Qwbwith 24 Hours Back Up 230 V, 45 – 60 Hz. - 01 Nos. ( Ii ) Contactor 63 Amps, 3 Pole 415 Volts- 01 Nos. ( Iii ) Toggle Switch With Manual, Timer And Off Position And All As Directed. ( Iv ) Mccb 100 Amps, 15 / 16 Ka, Tp, 415 Volts, Fixed & Thermal Magnetic Release Type -01 Nos ( V ) Internal Wirings Complete With 2.5 Sqmm For Timer Circuits / And 10 Sqmm Copper Wires For Out Going Circuits And Termination With Copper Thimbles. - 01 Job ( Vi ) Mcb Sp 0.5 Amps For The Control Of The Timer - 01 Nos 70 Supply And Fix In Repair Of Post Top Lantern Led Light Fitting 35 Watt 5700K Energy Saving Environmental Friendly , Spun Aluminium Landscape Luminaire With High Power Led As Light Source , Complete All As Specified And Directed. Make : Havells Model Ruby Clear Ip 65 Cat Part No Coralpt35wled757psymtopc Or In Equivalant In Philips & Crompton Greaves. 71 S&F In Repair Of Cast Aluminium Designer Bollardast With Polyurethane Paint ( With Prior Treatment ) With Clear Acrylic Diffuser Having 5 Duly Stack Lowers B-22 Porcelain Holder Provided Suitable For 12 To 20 Watt Led Bulb Incl 20 Watt Led Bulb Andas Per Is 10322 Part 5 Section-1 Latest 2017 All As Specified And Directed. Make :Mepro Cat Part No Mbl-Br-23 / Bajaj / Cg / Havells.Note : ( I ) Total Length Of Bolard 37 Inch. Base Diameter 9.1 Inches. Breadth Of Bollard Will Be 6.3 Inches. ( Ii ) Rate Of 20 Watt Led Bulb Are Included In Unit Rates. 72 M&L Periodicalservicing Of Diesel Engine Driven Gen Set 3 Phase 415 Volts 50 C / S Ac Supply By Cleaning Thoroughly And Replacing Fuel Filters , Air Filters, Oil Filtersdraining Out Engine Oil Etc. And Replacing With New Oil, Tightening Of All Gaskets , Connection Of Battery Terminals, Electric Cable Connections Foundation Bolts, Coupling Bolts Etc Includingtest Running And Tappet Setting Of Alternator By Checking And Setting Of Voltage And Frequency All As Directed By Engr-In-Charge. Make Of Dg Set : Kirloskar / Crompton Greaves / Cummins.Make Of Filters : Kirloskar / Cg / Fleet Guard / Miconote:Engine Oil, Fuel Filters, Air Filters, Oil Filtersreplaced Will Be Measured And Paid Separately Under Respective Item Ofsch A . Forfollowingcapacities Of Dg Set 73 160Kva Dg Set 74 100 Kva Dg Set 75 63 / 62.5 Kva Dg Set 76 40 / 50 Kva Dg Set 77 25 / 30 Kva Dg Set 78 M&L For Coolant Radicool Sfo Premix Of Castrol Or Equivalent Of Tvs / Volvoline 79 M&L To Drain Out The Old Used Engine Oil From Sump Of Dg Sets& Cleaning & Refilling With New Engine Oil 15 W 40 Up To Required Level Including Topup Make : Castrol / Hp Or Equivalent Of Servo 80 Supply Only Diesel Filter Suitable For 25 Kva To 100 Kva Dg Set 81 Supply Only Diesel Filter Suitable For 160Kva Dg Set 82 Supply Onlylub Oil Filter Suitable For 25 Kva To 100 Kva Dg Set 83 Supply Only Lub Oil Filter Suitable For 160Kva Dg Set 84 Supply Onlyairfilter Suitable For 25 Kva To 100 Kva Dg Set 85 Supply Only Air Filter Suitable For 160Kva Dg Set 86 Supply And Fixing In Replacement Of Maintenance Free Batterywith Initiallychargedcapacity 180 Ah , 12 Volt Complete All As Specified And As Directed. Make :- Exide / Amron 87 Supply And Fixing In Replacement Of Maintenance Free Batterywith Initiallychargedcapacity 150 Ah , 12 Volt Complete All As Specified And As Directed. Make :- Exide / Amron 88 Supply And Fixing In Replacement Of Maintenance Free Batterywith Initiallychargedcapacity90 Ah , 12 Volt Complete All As Specified And As Directed Make :- Exide / Amron 89 M&L For Replacement Of Unsv Radiatorhose Pipeset Complete As Per Sample Of D G Set Of Following Capacity 90 160Kva Dg Set . 91 100 Kva Dg Set . 92 63 / 62.5 Kva Dg Set . 93 40 / 50 Kva Dg Set . 94 25 / 30 Kva Dg Set . 95 M & L For Replacement Of Unsv Fan Belts As Per Sample For Dg Sets Of Following Capacity. Make: Fenner / Grip / Dunlop / Kiloskar 96 Fan Belt For 160Kva Dgset . 97 Fan Belt For 100 Kva Dgset . 98 Fan Belt For 63 / 62.5 Kva Dgset . 99 Fan Belt For 40 / 50Kva Dgset . 100 Fan Belt For 25 / 30Kva Dgset . Make: Fenner Cat Part No. 02.542.02.00 101 M&L In Replacement Of Stranded Copper Conductor Battery Lead For 24 Volts D C Grade Red For ( + ) Ve Terminal And Black For ( - ) Ve Terminal Fitted With Battery Terminal At One End & Battery Lug At Other End Complete Length 1.5 Mtr. 102 M & L For Cleaning Of Radiator By Cleaning Agent / Radiwash ( Make:Fleetguard / Coolguard ) Including Removal / Dismantling Of Radiator From Engine Transporting To Work Shop Or Cleaned At Site , Soldering / Brazing, Testing For Any Leakage , Remounting To Its Original Position As Per Entire Satisfaction Of Engr - In-Charge For Following Capacity Of Dg Set. 103 Dg Set 160Kva Dgset 104 Dg Set 100 Kva Dgset 105 Dg Set 63 / 62.5 Kva Dgset 106 Dg Set40 / 50Kva Dgset 107 Dg Set 25 / 30Kva Dgset 108 M & L For Replacement Of Set Of Hose Clips For Dg Sets Of Following Capacity 109 Dg Set 160Kva Dgset 110 Dg Set 100 Kva Dgset 111 Dg Set 63 / 62.5 Kva Dgset 112 Dg Set40 / 50Kva Dgset 113 Dg Set 25 / 30Kva Dgset 114 M&L For Replacement Of Defective Self Starter Assembly By New Self Starter Assembly 12 / 24 Volts 115 M&L For Replacement Of Defective Alternator Assembly By New Alternator Assembly. 116 M&L In For Replacement Of Pcb Card Procom R E L-7-1.0 For 160 / 100 Kvaamf Pannel. 117 M&L In For Replacement Coil Relay-24 Volts, 5 Amp 240 Volt Ac 5Amp 30 Volts Dc Model Hjq 22 F –Vz 118 M&L In For Replacement Of Timer Switch0 To 80 Seconds Makeasian / Ticnner For160 / 100Kva Amf Pannel 119 M&L For Servicing Of Dg Set 160 Kva Amf Panel, Setting Of Time Delay Switch , Tightening Of All Electrical Incoming & Outgoingconnections Including Replacement Of Cable Lugs& Adjustment Of Solenoid Switches& Relays 120 M&L For Servicing Of Dg Set 100 Kva Amf Panel, Setting Of Time Delay Switch , Tightening Of All Electrical Incoming & Outgoingconnections Including Replacement Of Cable Lugs& Adjustment Of Solenoid Switches& Relays 121 Supplying, Installation, Testing And Commissioning Of Electronic Battery Charging Setsuitable For Charging Batteries12 / 24 V, 10 / 12Amps Complete With Meter Equipments, Selector Switch With Required Size Of Copper Wire Up To Required Lengthand 1No. 3 Pin Plug Top 5 Amps Complete All As Specified ( In Repairs ) . Make : Technica / Acn / Ae 122 Supply And Replacing In Repair Euroload Four Pole Change Over With Advance Neutral On Load Change Over Switch I-O-Ii , Current Rating 100 Amps, 415 Volts Complete All As Specified And Directed.Make Havells / Indoasian / C&S. 123 Supply And Replacing In Repair Euroload Four Pole Change Over With Advance Neutral On Load Change Over Switch I-O-Ii , Current Rating 200 Amps, 415 Volts Complete All As Specified And Directed.Make Havells / Indoasian / C&S. 124 Supply And Replacing In Repair Euroload Four Pole Change Over With Advance Neutral On Load Change Over Switch I-O-Ii , Current Rating 400 Amps, 415 Volts Complete All As Specified And Directed. Make Havells / Indoasian / C&S. 125 Supply & Fixingspare Parts & Accessories Of Original Make For Repair Of Dg Set Of Capacity 63 / 62.5 Kva All As Directed By Engr-In-Charge :- 03 Nos Dg Setsnotes :- All Spares & Accessories Shall Be Fixed In The Dg Set Only After Prior Inspection & Approval Of Engineer-In-Charge For Which These Shall Be Produced By The Contractor At Store Yard Of Age E / M Old Cantt 126 Kit Fuel Filter 127 Kitlub Oil Filter 128 Kit Bypass Filter 129 Kit Air Cleaner 130 Air Filter 131 Upper Gasket Set ( Cylinder Head ) 132 Valve Exhaust 133 Valve Inlet 134 Valve Seat Exhaust 135 Valve Seat Inlet 136 Guide Valve 137 Collet Volve 138 Spring Valve 139 Kit Turbo Charging 140 Collar Thrust 141 Kit Injector 142 Kit Piston And Ring Set 143 Kit Cylinder Liner 144 Kit Sump Gasket 145 Gear Pump Assembly ( Fuel Pump Fip ) 146 Weight & Carrier 147 Barrel Sleave 148 Gasket Set 149 Sexen Filter 150 Gear Assembly 151 Ball Bering 152 Head Gasket 153 Nozzle 154 Block 155 Liner 156 Battery Terminal 157 Packing Kit 158 Crank 159 Main Bearing 160 Cr Bearing 161 Came Bush 162 Connecting Rod 163 Rod Balancing 164 Bush 165 Third Washer 166 Valve Seal 167 Supply & Fixingspare Parts & Accessories Of Original Make For Repair Of Dg Set Of Capacity 40 / 50 Kva All As Directed By Engr-In-Charge :- 01 Nos Dg Setsnotes :- All Spares & Accessories Shall Be Fixed In The Dg Set Only After Prior Inspection & Approval Of Engineer-In-Charge For Which These Shall Be Produced By The Contractor At Store Yard Of Age E / M Old Cantt 168 Kit Fuel Filter 169 Kitlub Oil Filter 170 Kit Bypass Filter 171 Kit Air Cleaner 172 Air Filter 173 Upper Gasket Set ( Cylinder Head ) 174 Valve Exhaust 175 Valve Inlet 176 Valve Seat Exhaust 177 Valve Seat Inlet 178 Guide Valve 179 Collet Volve 180 Spring Valve 181 Kit Turbo Charging 182 Collar Thrust 183 Kit Injector Repair 184 Kit Piston And Ring Set 185 Kit Cylinder Liner 186 Kit Sump Gasket 187 Gear Pump Assembly ( Fuel Pump Fip ) 188 Weight & Carrier 189 Barrel Sleave 190 Gasket Set 191 Sexen Filter 192 Gear Assembly 193 Ball Bering 194 Dismantling Ofdg Set Alternator Of Cap 63 / 62.5 Kva Carefully And Carry To Authorised Workshop For Repair And Re-Fixing The Same In Its Original Position After Repair And Testing The Same Up To Satisfaction Of Age E / M Complete All As Direted. 195 Cutting Out Old Burnt Winding Of Alternator, Cleaning The Slot Of Stator And Rewinding The Same With Super Enamelled Copper Winding Wire Of Appropriate Gauge Complete With All Insulating Materials, Nomex Paper, Cotton Tape, Glass Sleeve, Soldering Rod, Grease Etc Complete. 196 Repairing Ofarmature Shaft Both Side By Depositing Metal On It, Grinding & Polishing To Make Appropriate Size Of The Shaft Complete. 197 Supply And Replacingball Bearing At De ( Driven End ) Side Of No.6310 198 Supply And Replacing Rectifier Diod. 199 Supply And Replacing Avr ( Automatic Voltage Regulaotr ) . 200 Supply And Replacing Connetion Plate Of Suitable Size. 201 Dismantling Ofdg Set Alternator Of Cap 100 / 160Kva Carefully And Carry To Authorised Workshop For Repair And Re-Fixing The Same In Its Original Position After Repair And Testing The Same Up To Satisfaction Of Age E / M Complete All As Direted. 202 Cutting Out Old Burnt Winding Of Alternator, Cleaning The Slot Of Stator And Rewinding The Same With Super Enamelled Copper Winding Wire Of Appropriate Gauge Complete With All Insulating Materials, Nomex Paper, Cotton Tape, Glass Sleeve, Soldering Rod, Grease Etc Complete. 203 Repairing Ofarmature Shaft Both Side By Depositing Metal On It, Grinding & Polishing To Make Appropriate Size Of The Shaft Complete. 204 Supply And Replacingball Bearing At De ( Driven End ) Side Of No.6310 / 6311 / 6312 / 6314. 205 Supply And Replacing Rectifier Diod. 206 Supply And Replacing Avr ( Automatic Voltage Regulaotr ) . Tvr-20 207 Supply And Replacing Connetion Plate Of Suitable Size. 208 Dismantling Ofdg Set Alternator Of Cap 25 / 30 / 40 Kva Carefully And Carry To Authorised Workshop For Repair And Re-Fixing The Same In Its Original Position After Repair And Testing The Same Up To Satisfaction Of Age E / M Complete All As Direted. 209 Cutting Out Old Burnt Winding Of Alternator, Cleaning The Slot Of Stator And Rewinding The Same With Super Enamelled Copper Winding Wire Of Appropriate Gauge Complete With All Insulating Materials, Nomex Paper, Cotton Tape, Glass Sleeve, Soldering Rod, Grease Etc Complete. 210 Repairing Ofarmature Shaft Both Side By Depositing Metal On It, Grinding & Polishing To Make Appropriate Size Of The Shaft Complete. 211 Supply And Replacingball Bearing At De ( Driven End ) Side Of No.6310 / 6311 / 6312 / 6314 Make-Nbc / Skf-01 No 212 Supply And Replacing Rectifier Diod. 213 Supply And Replacing Avr ( Automatic Voltage Regulaotr ) . 214 Supply And Replacing Connetion Plate Of Suitable Size. 215 Supply & Fix In Repairs Cable Looping Box Shock & Rust Proof Of External Dimension 230Mm X 170Mm X 105 Mmincluding Provision Of 4 Way Heavy Duty Pvc Insulated Connector Of Suitable Size Including Fixing Clamp, Nut Bolts , Washer And Mcb Of Suitable Capacityall As Directed By Engineer-In-Charge. Make: Sintex Cat No. Gsjb-2014 Or Equivalent Inlegrand / Havells / Hensel. 216 S&F In Replacement For Mccb , 4 Pole, 415 Volts, 160 Amps, Breaking Capacity 36Ka, Adjustable Thermal Magnetic Release Including Taking Outold / Unserviceble Mccb Complete All As Specified And Directed. 217 S&F In Replacement For Mccb , 4 Pole, 415 Volts, 250 Amps, Breaking Capacity 36Ka, Adjustable Thermal Magnetic Release Including Taking Outold / Unserviceble Mccb Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Apr-2024 Date Postponed Date 27-04-2024
2 18-Apr-2024 Date Extend Date 04-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 89700.0 /-
Tender Value
INR 44.85 Lakhs /-

Attachment

FileName File Description File Size
8275be0c-abad-4b50-bc20-b1669dc9e8ba.html Tender Notice 0 KB
BOQ_725188.xls Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail