Tender For E-Tender For The Electrification Work Of Heat Treatment Plant At Sidco Pressure Die Casting Unit Pappanamcode, thiruvananthapuram-Kerala

Kerala Small Industries Development Corporation Limited has published Tender For E-Tender For The Electrification Work Of Heat Treatment Plant At Sidco Pressure Die Casting Unit Pappanamcode. Submission Date for this Tender is 30-03-2024. Electrification Work Tenders in thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

43033100
Tender For E-Tender For The Electrification Work Of Heat Treatment Plant At Sidco Pressure Die Casting Unit Pappanamcode
Open Tender
Indian
Kerala
thiruvananthapuram
30-03-2024

Tender Details

E-Tender For The Electrification Work Of Heat Treatment Plant At Sidco Pressure Die Casting Unit Pappanamcode , Wiring Of Light, Fan, Exhaust Fan &6A / 16A Sockets , 90.2.1.1 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) . , 90.2.1.4 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) . , 90.2.1.6 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A, Switch In The Same Switch Board As That Of Light Points , 1.7.1 : Wiring For Circuit / Sub Main Wiring Alongwith Earth Wirewith The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 1.7.2 : Wiring For Circuit / Sub Main Wiring Alongwith Earth Wirewith The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2x2.5 Sq.Mm+1X2.5 Sq.Mm Earth Wire , 1.15.3 : Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.Group C , 1.21.1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm , 1.23.4 : Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , 1.27.4 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module ( 200Mmx75mm ) , 1.27.5 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.8 Module ( 125Mmx125mm ) , Earthing , 5.4 : Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , 5.16 : Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. , 90.16.5.6 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. , Supply Of Materials , 2.4.5 : Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 6 Way ( 4+18 ) , Double Door , 2.10.1 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , 2.13.3 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.100 Amps , 2.2.2 : Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125 Amp, 16 Ka, Tpmccb , 90.3.19.2 : Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories Andlamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copperconductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required , 90.3.20.1 : Supply & Installation Of Light Fittings On Tw Round Block <Br> Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required. , Od352275 / 2023_2024 : Supply , Testing, Fixing And Commissioning Of Fire Extinguisher 5 Kg Type , Od352284 / 2023_2024 : Preparation Of Electrical Layout / Drawing For Necessary Approvals From The Eb, Liasoning With These Authorities ( Charges Should Include All Miscellaneous And Sundries, Only Statutory Charges Will Be Reimbursed. ) , Od352285 / 2023_2024 : Labour Charges For Dismantling Of Existing Panel Board, Distribution Boards, Ug Cable, Wires, Conduits, Ceiling Fans, Tube Lights, Switch Box, Down Rods, Meter Board Panels, Other Electrical Accessories Etc. , Od352348 / 2023_2024 : 300 Mm Sweep Wall Mounting Fan , Od352360 / 2023_2024 : Supply & Fixing The Following Power Capacitors Duty Contactor In Position And Giving Connection.&Lt;Br&Gt;5 Kvar, 3 Phase, 415 V , Od352363 / 2023_2024 : Supply Of Exhaust Fan 450Mm Sweep , Od352373 / 2023_2024 : Provision For Kseb Load Enhancement , 90.12.6.30 : Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. , 2.3.1 : Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator6 Way, Double Door , 2.5.2 : Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 8 Way ( 4 + 24 ) , Double Door , 2.13.1 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.13.2 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 2.14.1 : Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps , 2.24.1 : Supplying And Fixing Cable End Box ( Loose Wire Box ) ( Ip 43 ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required.For 4 Way, Double Door Tpn Mcbdb , 1.27.4 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module ( 200Mmx75mm ) , 1.27.5 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.8 Module ( 125Mmx125mm ) , 90.10.3.14 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) , 90.10.3.15 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) , 2.7.4 : Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+4 Way, Double Door , 90.14.24.51 : Supply & Fixingthe Following Power Capacitors 3 Phase Delta Connected In Positon And Giving Connection. , Shiftng Of Connections , Od348603 / 2023_2024 : Dismantling The Existing Multiway - Single Phase / Three Phase Distribution Board Along&Lt;Br&Gt;With The Mcbs, Isolators Etc At The Existing Site And Installation Of The Same At The New&Lt;Br&Gt;Site Including The Mcbs, Isolator Etc And Giving All Connections Properly As Per The&Lt;Br&Gt;Directions Of The Engineer In Charge , Od348619 / 2023_2024 : Table Fan - 100% Copper Motor Designed For Indian Conditions Consumes Only 55W. Sweep 400 Mm&Lt;Br&Gt;Uniform And Jerk Free Oscillation And Easy Tilting Mechanism To Set The Air Flow As Required&Lt;Br&Gt;Sturdy And Safe: With A Wide Base And A Resettable Fuse To Protect From Thermal Overload&Lt;Br&Gt;Easy Assembly : Follow Step By Step Instruction As Per Manual&Lt;Br&Gt;Air Delivery: 67 Cubic Meter Per Minute And Speed: 1280 Rpm , Cable Laying , 90.10.3.14 : Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) , 90.12.1.18 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . , 90.12.1.28 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . , 90.12.1.41 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . , 90.12.1.3 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . , Extra Civil Items For Fixing Tubelight , 10.31 : Providing And Fixing Angle Iron Frames For Doors, Windows And Ventilators Of Mild Steel Angle Sections Of Size 35X35x5 Mm, Joints Mitred And Welded By Angle Iron 35X35x5 Mm Or 35X 5 Mm Flat Pieces To The Existing T-Iron Frame Or To The Wall With Dash Fastener, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer, All Complete As Per The Direction Of Engineer In Charge.

Key Value

Document Fees
INR 861 /-
EMD
INR 9129.0 /-
Tender Value
INR 3.65 Lakhs /-