Tender For Repair / Maintenance Of Centrifugal, Monoblock And Submersible Pump Set In Kwc Lab Area And Day To Day Repair / Maint Complaints For Water Supply Lines Inkwcarea And Certain Allied Worksunder Ge ( I ) R&D Delhi, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Centrifugal, Monoblock And Submersible Pump Set In Kwc Lab Area And Day To Day Repair / Maint Complaints For Water Supply Lines Inkwcarea And Certain Allied Worksunder Ge ( I ) R&D Delhi. Submission Date for this Tender is 20-05-2024. Submersible Pump Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43032626
Corrigendum : Tender For Repair / Maintenance Of Centrifugal, Monoblock And Submersible Pump Set In Kwc Lab Area And Day To Day Repair / Maint Complaints For Water Supply Lines Inkwcarea And Certain Allied Worksunder Ge ( I ) R&D Delhi
Open Tender
Indian
Delhi
delhi
20-05-2024

Tender Details

Repair / Maintenance Of Centrifugal, Monoblock And Submersible Pump Set In Kwc Lab Area And Day To Day Repair / Maint Complaints For Water Supply Lines Inkwcarea And Certain Allied Worksunder Ge ( I ) R&D Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Mar-2024 Corrigendum01 Date 13-04-2024
2 03-Apr-2024 Corrigendum02 Date 23-04-2024
3 12-Apr-2024 Corrigendum03 Date 04-05-2024
4 26-Apr-2024 corrigendum04 Date 13-05-2024
5 04-May-2024 corrigendum05 Date 20-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 46.98 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR / MAINT OF CENTRIFUGAL, MONOBLOCK AND SUBMERSIBLE PUMP SET IN KWC LAB AREA AND DAY TO DAY REPAIR/MAINT COMPLAINTS FOR WATER SUPPLY LINES INKWCAREA AND CERTAIN ALLIED WORKSUNDER GE(I) R&D DELHI
Sl. No. Item Description
1Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor ofcapacities5-15 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
2All as per item No 1.00 above but of capacity 20-30 HP
3All as per item No 1.00 abovebut of capacity 40-50 HP
4All as per item No 1.00 above but of capacity 60-100 HP
5Opening the electric induction motor ofcapacity 5-15 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material to make it functionalcomplete all as specified and as directed . Note:- Copper winding wire of approprioate guage will be measured in supply only
6All as per item No 5.00 abovebut of capacity 20-30 HP
7All as per item No 5.00 above but of capacity 40-50 HP
8All as per item No 5.00 above but of capacity 60-100 HP
9Disconnecting and De-coupling the Centrifugal pump ofcapacity 5-15 HP from foundation after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for repairand back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed.
10All as per item No 9.00 above but of capacity 20-30 HP
11All as per item No 9.00 abovebut of capacity 40-50 HP
12All as per item No 9.00 above but of capacity 60-100 HP
13Opening the centrifugal pump/monoblock ofcapacity, 5-15 HP repairing the same by replacing the unserviceable spare parts like gasket, glands, any type/size nut, bolt, washer, front / rear end bearing, ball bearing, key, ring, cable seal, shaft, water seal, etc including machining work and re-assembling the same in original position complete all as specified and as directed. Note:- AllSpare Parts required for smooth functioning of the pump will be replaced with new one except impeller and rates for the same are inclusive in the EachJob.
14All as per item No 13.00 above but of capacity 20-30 HP
15All as per item No 13.00 above but of capacity 40-50 HP
16All as per item No 13.00 above but of capacity 60-100 HP
17Supplyonly in repair CI impeller along with lock key for centrifugal pump / monoblock / split casing pumps as per existing suitable for under mentioned pumps complete all as spd and directed.
185 to 15HP
1920 to 30HP
2040 to 50HP
2160 to 100 HP
22S&F in repair Terminal Connection Plate ofcapacity 5-15 HP Complete all as specified & directed.
23S&F in repair Terminal Connection Plate ofcapacity 20-30 HP Complete all as specified & directed.
24S&F repair Terminal Connection Plate ofcapacity 40-50 HP Complete all as specified & directed.
25S&F in repair Terminal Connection Plate ofcapacity 60-100 HP Complete all as specified & directed.
26S&Fin repair spare tyre for couplingtype TC/P/011 complete all as specified & directed.
27S&F in repair spare tyre for couplingtype TC/P/013 complete all as specified & directed.
28S&F in repair spare tyre for couplingtype TC/P/014 complete all as specified & directed.
29S&F in repair spare tyre for couplingtype TC/P/015 complete all as specified & directed.
30S&F in repair spare tyre for couplingtype TC/P/019 complete all as specified & directed.
31S&F in repair 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed.
32S&F in repair 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
33S&F in repair 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
34S&F in repair 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
35S&F in repair 3 pole power contactor type ML-6,110 Amps,415 Volts, 50 HZ complete all as specified and as directed.
36S&F in repair Bimetal over load relay type ML 1.5, starter type MNX, relay range 14-23 Amp complete all as specified and as directed.
37S&F in repair Bimetal over load relay typeML 2, starter type MNX, relay range 20-32 Amps complete all as specified and as directed.
38S&F in repair Bimetal over load relay typeML 3, starter type MNX, relay range 28-42 Amps complete all as specified and as directed.
39S&F in repair Bimetal over load relay typeML 4/6, starter type MNX, relay range 45-75 Amps complete all as specified and as directed.
40S&F in repair Bimetal over load relay typeML 5, starter type MN, relay range 66-110 Amps CT operated.
41S&F in repair automatic star - delta starter with sheet enclosor pump controller with type MUG ML 1.5 , 415 volt complete all as specified and as directed.
42S&F in repair automatic star - delta starter with sheet enclosor pump controller with type MUG ML2 ,415 volt complete all as specified and as directed.
43S&F in repair automatic star - delta starterwith sheet enclosor pump controller with type MUGML 3, 415 volt complete all as specified and as directed.
44S&F in repair automatic star - delta starter with sheet enclosor pump controller with type MUG ML4, 415 volt complete all as specified and as directed.
45S&F in repair PVC insulated multistranded copper conductor wire of size 2.5 sqmm, single core, 1100 volts complete all as specified and as directed.
46S&F in repair PVC insulated multistranded copper conductor wire of size 4 sqmm, single core, 1100 volts complete all as specified and as directed.
47S&F in repair PVC insulated multistranded copper conductor wire of size 6 sqmm, single core, 1100 volts complete all as specified and as directed.
48S&F in repair PVC insulated multistranded copper conductor wire of size10 sqmm, single core, 1100 volts complete all as specified and as directed.
49S&F in repair PVC insulated multistranded copper conductor wire of size 16 sqmm, single core, 1100 volts complete all as specified and as directed.
50S&F in repair PVC insulated multistranded copper conductor wire of size 25 sqmm, single core, 1100 volts complete all as specified and as directed.
51S&F in repair Amp Meter Digital type 0 to 100 Amp of size 96 x 96 mm complete all as specified and as directed.
52S&F in repair Amp Meter Digital type 0 to 200 Amp of size 96 x 96 mm complete all as specified and as directed.
53S&F in repairAmp Meter Digital type 0 to 400 Amp of size 96 x 96 mm complete all as specified and as directed.
54S&F in repair Indicating light RYG LED type complete all as specified and as directed.
55S&F in repair current transformer ratio 100/5 complete all as specified and as directed.
56S&F in repair current transformer ratio 200/5 complete all as specified and as directed.
57S&F in repair current transformer ratio 400/5 complete all as specified and as directed.
58S&F in repair Amp meter selector switch complete all as specified and as directed.
59S&F in repair Volt meter selector switch complete all as specified and as directed.
60S&F in repair MS foundation bolts with nuts and washers, size 20mm dia , 450 mm long complete all as specified and as directed.(including breaking of hard standing foundation)
61S&F in repair Vibration Pad with nuts, bolts and washers, for existing capacity of 20-30 HP complete all as specified and as directed.
62S&F in repair Vibration Pad with nuts, bolts and washers, for existing capacity of 40-60 HP complete all as specified and as directed.
63S&F in repair Vibration Pad with nuts, bolts and washers, for existing capacity of 60-100 HP complete all as specified and as directed.
64Disconnecting water pipe line , electric connection and taking out submersible pump set of any capacity alongwith column pipe and submersible cable and re-lowering the same after repairing of submersible pump setincluding replacement of rubber gasket , nuts,bolts and washer where ever required complete all as specified and directed. Note:- AllSpare Parts like Rubber gasket , nuts,bolts and washers etc required for smooth functioning of the pump setwill be replaced with new one except repairing / winding of submersible pump set and rates for the same are deemed to be inclusive in the qouted rates.
65Supplying , fixing & testing in replacement water proof submersible copper conductor cable of size, 4 sqmm, 3 core ,1100 Volts, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints after taking down/out old unserviceable submersible cable complete all as specified and as directed .
66S&F in repair MS tubing heavy duty,Class -C, column pipe,size 50 mm bore, 3 meter long, Conforming to IS-1239, coupled with heavy dutysuitable size MS flanges 12mm thick duly welded on both sides with and including necessary nuts, bolts , washers , rubber packing etc and lowered into the bore well after taking down/out old unserviceable column pipe complete all as specified and as directed . Notes: - (i)Length of Eachcolumn pipe shall be 3 Mtrs. (ii) Taking down/out and Lowering of Submersible pump set shall be measured and paid separately.
67S&F in repair MS tubing heavy duty,Class -C, column pipe,size 80 mm bore, 3 meter long, Conforming to IS-1239, coupled with heavy dutysuitable size MS flanges 12mm thick duly welded on both sides with and including necessary nuts, bolts , washers , rubber packing etc and lowered into the bore well after taking down/out old unserviceable column pipe complete all as specified and as directed . Notes: - (i)Length of Eachcolumn pipe shall be 3 Mtrs. (ii) Taking down/out and Lowering of Submersible pump set shall be measured and paid separately.
68S&F in repair CI Non return Valve of dia 50 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and boltsISI Marked, as per IS:5312 complete all as specified & directed.
69S&F in repair CI Non return Valve of dia 80 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and bolts ISI Marked, as per IS:5312 complete all as specified & directed.
70S&F in repair cast iron Sluice Valveof dia 50 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
71S&F in repair cast iron Sluice Valveof dia 80 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
72S&F in repair cast iron Sluice Valveof dia 100 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
73S&F in repair cast iron Sluice Valveof dia 150 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
74M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for Providing, cement concrete in roof kerbs or mud stops, copying of valve pit chamber etc rounded or chamfered on edges complete inculding demolition of existing unserviceable PCC all as specified & directed
75M&L for PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) for Cement concrete in foundations, filling and mass concrete, pits etc complete including demolition existing unserviceable PCC allas specified & directed.
76Supply, laying and testing in repair cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) inculding disconnecting and taking out old cable 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core including disconnecting and taking out old cable complete all as specified & directed
77Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittingsin trenches/ wall/ floor as directedof size 20 mm borecomplete all as specified & directed
78Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittingsin trenches/ wall/ floor as directedof size 25 mm borecomplete all as specified & directed
79Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittings in trenches/ wall/ floor as directedof size 40 mm bore complete all as specified & directed
80Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittings in trenches/ wall/ floor as directedof size 50 mm bore complete all as specified & directed
81Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittings in trenches/ wall/ floor as directedof size 80 mm bore complete all as specified & directed
82Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor as directedof size 100 mm borecomplete all as specified & directed
83Opening the submersible pump set of capacity upto 7.5 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. ,repairing the same by replacing the unserviceable spare parts like GM bearing, cable seal, motor base, any type of housing, bearing, water seal,O ring, nut bolt, coupling , impeller, key, shaft etc including machining work and re-assembling the pump set in original position with required insulating material to make it functionalcomplete all as specified and as directed . Note:- AllSpare Parts l like GM bearing, cable seal, motor base, any type of housing, bearing, water seal,O ring, nut bolt, coupling , impeller, key, shaft etc including machining work and re-assembling the pump set in original position with required insulating material to make it functionalcomplete required for smooth functioning of the pump setwill be replaced with new one and rates for the same are deemed to be inclusive in the qouted rates.
84Supplying and assembling in repair super enamelled copper winding wire of appropriate gauge suitable for upto any capacitysubmersible pump sets/mono block pump/centrifugal pump complete all as specified and as directed.
85Supply and fixing in repair mild steel casing cover, heavy duty made out of Mild Steel sheet not less than 6mm thick suitable for upto 200 mm bore pipe after taking down/out cap as existing at site complete all as specified and as directed .
86Supply and fixing in repair MS clamps for upto80mm bore column pipe made out of Mild steel flat of size 80mm x 6 mm with two Nos of Mild steel nuts ,bolts etc. complete all as specified and as directed .
87Supply and fixing in repair DOL starter for 7.5 HP complete all as specified & directed
88Supply and fixing in repair DOL starter for 5 HP complete all as specified & directed
89S&F in repair dial type 2400 hours timer, 16 Amps, SP, after taking down/out starter as existing at site complete all as specified and as directed .
90Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out completeall as specified and as directed
91All as per item ser No 86 above but in hard/dense soil.
92All as per item ser No 86 above but in soft/disintigerated rocks.
93Returning,filling in and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm thick in any type of soil/rock to achieve desired thickness complete all as specified & directed.
94Removing surplus soil to a distance exceeding 1.5Km and depositing where directed at a level and not exceeding 5Km above the starting point complete all as specified and as directed.
95M&L for Sub class"B" brick, old size as cable protection cover, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to the length of the brick, completeall as specified and directed.
96Supply and spread clean dry river sand in trenches including leveling, punning for cushioning of cables complete all as specified & directed. Note : Punned thickness of sand cushioning shall be measured.
97S&F in repair Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) supply and Install complete upto 5 HP inclusive of 40 metre long submersible cable and starter complete all as specified & directed.
98S&F MS sheet/angle/flat/bars etc for fabrication of vaslve pit chamber, ladder, sump manhole, steps, covers, frame work etc inculding cutting to repaired shapes size including dismantling of old unserviceable complete all as specified & directed.
99M&L for bocky system under path/road to pass the GI/CI/DI Pipes upto 100 mm dia manually as directed.
100S&F in repair WOLTMAN typewater meter with removable mechanism CLASS-B Confirming to ISO: 4064/1 of dia 50 mm complete all as specified & directed.
101S&F in repair WOLTMAN typewater meter with removable mechanism CLASS-B Confirming to ISO: 4064/1 of dia 80 mm complete all as specified & directed.
102S&F in repair WOLTMAN typewater meter with removable mechanism CLASS-B Confirming to ISO: 4064/1 of dia 100 mm complete all as specified & directed.
103M&L for Rendering 10 mm thick plaster on brick work/concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified & directed.
104Supply and fix in repair Strainer Y type conforming to IS, size 80 mm (3”) dia complete all as specified & directed.
105Supply and fix in repair Strainer Y type conforming to IS, size 100 mm (4”) dia complete all as specified & directed.
106Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron 4mm dia wire by means of GI nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI wire 4mm dia (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
107S&F in replacement Earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried in ground or drawn in coduit/ pipe or any other indicated situation for loop earthing etc. as required 4 mm dia gavanised iron or steel wire complete all as specified.
108Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connectedwith GI strip 32x6 mm by means of nuts, bolts and washers.GI Wirelaid in 15mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:- (a)GI strip 32x6mm (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
109M&L Earth continuity conductor or main earthing lead fixed to wall or on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles with 32X6 mm GI strip including dismantling old unserviceable GI wire complete all as specified and directed.
110Dewatering, cleaning of 25000 gallons capacity reservoirs with high pressure jet incl lime wash on internal surfaces complete incl Writting the date of cleaning of water tank complete all as directed with the following process:- (i)Dewatering the tank with portable submersible pump set. (ii)Removal of left over dirty water and sludge with special sludge removal pump set . (iii) Cleaning of wall ceiling and floor by high pressure rotary water jet . (iv)Removing of remaining sludge from the floor with the help of industrial vacuum cleaner. (v)Spraying of non toxic biodegraded eco friendly anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful bacteria. (vi) Weather proof exterior emulsion paint two coats on externalsurfaces after removing/ scraping old painted surfaces complete.
111All as per ser item No. 106above but 50,000 gallons capacity.
112All as per ser item No. 106 above but 35,000 gallons capacity.
113All as per ser item No. 106above but service tank of capacity 1,00,000 Ltrs (RCC)
114All as per ser item No. 106 above but service tank of capacity 40,000 Ltrs (RCC)
115All asper ser item No. 106 above but 10,000 Gallons Semi UG sump.
116All as per ser item No. 106above but service tank of capacity 20,000 Ltrs (RCC).
117All as per ser item No. 106 above but service tank of capacity 10,000 Ltrs (RCC).
118M&L dewatering, cleaning of Service tank capacity 10000 ltrs (PVC) with high pressure jet including lime wash internally and clunted Writing of the date of cleaning of the water tank using synthetic enamel paint complete all as specified and directed.
119All as per ser item No. 114 above but Service tank of 5000 Ltrs (PVC).
120All asper ser item No. 114 above butService tank of 2000 Ltrs(PVC).
121All as per ser item No. 114 above butService tank of 1000 Ltrs (PVC).
122All as per ser item No. 114above but Service tank of 500 Ltrs(PVC).
123M&L for applying two coats of synthetic enamel paint over one coat of red oxide primer inculding prepartion of new steel surface complete all as specified & directed.
124Taking up or down carefully steel water tubing and connection from trenches, wall & floorincluding cleaning of serviceable pipes for refixing complete all as spd and directed of following sizes:-
12520 mm bore.
12625 mm bore.
12740 mm bore.
12850 mm bore.
12980 mm bore.
130100 mm bore.
131Refixing of old steel water tubing and connections in new or old position (wall/floor/ceilling/trecheh etc) complete all as spd and directed of following sizes:-
13220 mm bore.
13325 mm bore.
13440 mm bore.
13550 mm bore.
13680 mm bore.
137100 mm bore.
138M&L for cutting existing GI tubing for alteration or addition of sizes including screwing existing GI tubing for tapping & making new connection etc complete all as specified & directed of the following sizes :-
13920 mm bore.
14025 mm bore.
14140 mm bore.
14250 mm bore.
14380 mm bore.
144100 mm bore
145S&F in repairs gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified & directed of the following sizes :-
14620 mm bore.
14725 mm bore.
14840 mm bore.
14950 mm bore.
15080 mm bore.
151Drilling and tapping cast iron /DI water main ( in position ) for branch connection complete all as specified and directed.
15280 mm bore.
153100 mm bore.
154150 mm bore.
155200 mm bore.
156M & L for taking out sluice valves refacing , grinding, packing glands in stuffing box for prevention of leakage from valve and refixingcomplete all as specified and directed for following size.
15780 mm bore.
158100 mm bore.
159150 mm bore.
160S & F in replacement MS sheet cover for valve pit made out of 3.15 mm thick MS sheet with handle and locking arrangement, duly painted both sides with synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. .
161Construction of valve chamber of size 1200 x 1200 x 900 mm (internal dimensions) with the following specifications :- (i) 15cm thick PCC 1:4:8 type D-2 (using stone aggregate) as in foundation concrete. (ii) PCC solid block masonry 200 mm thick using grade C-5 block in CM 1:6 (iii) Rendering 15mm thick in CM 1:4 finished even and fair. (iv) PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping. (v) 3 mm thick MS sheet cover alongwith MS angle iron frame 40 x40 x6mm duly embedded incoping concrete with necessary lockingarrangement. (vi)Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer. (NOTE : Excavation and earthworkshall be measured and paid seperately under respective items of BOQ)
162All as per srl item No. 127 above but of internal dimension1200 x 1200 x 1000 mm.
163M & L for painting of valve pit covers on both sides after preparing of old painted surfaces and painting with one coat black paint all as specified and directed.
164S & F in repairs foot valve brass assembly 50 mm dia complete .
165S & F in repairs foot valve brass assembly 80 mm dia complete .
166Cleaning of pump house/sub station,surrounding area by surface excavation upto 10 cm depth incl removing shrubs,grass,miniplants and other unwanted materials and levelling complete in soft/loose soil all as specified and directed.
167Supply and fix in replacement rotational moulded polyethylene water storage tanks (vertical cylindricalwith closed top) double layered with ISI marked with existing inlet, outlets and provision of washouts (vent pipe all as directed of capacity ) are mentioned below : -
168500 ltrs
1691000 ltrs
1702000 ltrs
1715000 ltrs
17210000 ltrs
173Supply and fix in replacement ball valves high pressuremade out of PTMTMake- Prayag/Symet complete with epoxy coated Aluminium rod, high density ball etc of size :-
17415 mm bore.
17520 mm bore.
17625 mm bore.
17740 mm bore.
17850 mm bore.
179Supply and fix in replacement tank cover PVC suitable for tanks of any capacity with locking arrangement device. Make- Sintex / Polycon/Sheetal.
180Attending URGENT COMPLAINT by mechanic cum plumber for fault in theany type pump motor of centrifugal, monoblock, submersible etc nature complaints like motor sound, star delta connection issues, any type of cable burntMCCB / MCB tripping, No water supply, water leakage, air lock, low pressure, over flow etc. complain includes forcarrying out the minor repairs to make it functional by replacing necessary petty items like copper wires, rubber gasket, grease, screws, GI tees, band, elbow etc, complete all as spd and directed by engr in charge. Note- Rates for petty items as mentioned above are deemed to be inclusive in qouted rates.
181Supply only calcium hypchlorite granules ALTOCH-GP in air tight containersall as specified and directed.
182Supply and fix in repair Air release valve 25 mm dia, CI body with single air outlet confirming to IS-14845 all as specified and directed.
183Supply and fix in repair Air release valve 50 mm dia, CI body with single air outlet confirming to IS-14845 all as specified and directed.
184Supplying,laying jointing testing in replaement MS pipe, of dia 200mm Heavy duty clas "C" confirming to IS - 139, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, including welded flange complete all as specified and directed.
185Supplying,laying jointing testing in replaement MS pipe, of dia 150mm Heavy duty clas "C" confirming to IS - 139, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, including welded flange complete all as specified and directed.
186Supplying,laying jointing testing in replaement MS pipe, of dia 80mm Heavy duty clas "C" confirming to IS - 139, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, including welded flange complete all as specified and directed.
187Taking up carefully from trenches CI /DI water mains incl all fittings with spigot and socket ends and lead joints incl burning out lead joint and recovering lead for the complete all as specified and directed.
18880 mm bore.
189100 mm bore.
190150 mm bore.
191Laying only CI /DI pipes taken out from trench for repairscomplete all as specified and directed.
19280 mm bore.
193100 mm bore.
194150 mm bore.
195S&F in replacement mechanical joints ISI marked with nut bolts washers rubber gaskets etc of following sizes :-
19680 mm bore.
197100 mm bore.
198150 mm bore.
199S & F in repairs stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of following size complete all as specified :-
20020 mm bore.
20125 mm bore.
20240 mm bore.
20350 mm bore.
204Supply , laying and testing ductile iron pipe with internal cement mortar lining and external zink pipes confirming to IS : 18329 - 2000 with class of pipe K-7 of size 80 mm complete all as spd and directed
205Supply , laying and testing ductile iron pipe with internal cement mortar lining and external zink pipes confirming to IS : 18329 - 2000 with class of pipe K-7 of size 100 mm complete all as spd and directed
206Supply , laying and testing ductile iron pipe with internal cement mortar lining and external zink pipes confirming to IS : 18329 - 2000 with class of pipe K-7 of size 150 mm complete all as spd and directed
207M & Lfor cuttingCI/DI pipe to required length in position for insertion of new tee"s branches etc for the pipe of 80 mm bore complete all as spd and directed
208M & Lfor cuttingCI/DI pipe to required length in position for insertion of new tee"s branches etc for the pipe of 100 mm bore complete all as spd and directed
209M & Lfor cuttingCI/DI pipe to required length in position for insertion of new tee"s branches etc for the pipe of 150 mm bore complete all as spd and directed
210S&F in replacement CI/DI specials such as bends sockets tee"s for spigot and socketed pipes upto 250mm dia bore complete all as specified and directed.
211S&F in replacement cast iron non return (reflux) valve flanged ends in swing type design as per IS 5312 Part-1, PN-1.0, with gun metal sheet complete all as specified and directed of following sizes.:-
212100 mm bore
213150 mm bore
214S&F in repairGI Socket medium Grade, ISI marked of Size 15 mm to 25 mm complete all as specified and directed.
215S&F in repairGI Socket medium Grade, ISI marked of Size 40 mm to 80 mm complete all as specified and directed.
216S&F in repairGI Elbow medium Grade, ISI marked ofSize 15 mm to 25 mm complete all as specified and directed.
217S&F in repairGI Elbow medium Grade, ISI marked ofSize 40 mm to 80 mm complete all as specified and directed.
218S&F in repairGI Union medium Grade, ISI marked ofSize 15 mm to 25 mm complete all as specified and directed.
219S&F in repairGI Union medium Grade, ISI marked ofSize 40 mm to 80 mm complete all as specified and directed.
220S&F in repairGI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of Size 15 mm to 25 mm complete all as specified and directed.
221S&F in repairGI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of Size 40 mm to 80 mm complete all as specified and directed.
222S&F in repairGI Reducing socket mediumgrade ISI marked of Size 25 mmx20 mm complete all as specified and directed.
223S&F in repairGI Reducing socket mediumgrade ISI marked of Size 50 mmx 40mm complete all as specified and directed.
224S&F in repairGI solid plugheavy dutyISI marked of Size 15 mm to 25 mm complete all as specified and directed.
225S&F in repairGI solid plugheavy dutyISI marked of Size 40 mm to 50 mm complete all as specified and directed.
226Testing of drinking water being collected from local source (bore wells/sump /shallow wells) of KWC Area & Metcalfe House Area underGE(I) R&D Delhi and submission of detailed test report to the office of Engr-in-Charge. (a) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in GOVT Approved laboratory as mentioned in specification. (b )Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, PH valve TDS total hardness iron, chloride, fluride and residual free chlorine and Bacteriological total coil from organisms per 100 ml (MPN) and E coli in 100 ml) and to this office with specific recommendation regarding suitabiulity of water for drinking purpose. Note:- Rate Quoated shall deemed to be included for :- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) (iii) Testing should be carried out from Govt approved lab.
227BLANK
228Cleaning of UG sumps by scraping the inner walls of sumps with suitable chemicals & cleaning with wire brush , taking out all dirt , scales etc and white washing the wall with two coats of lime after cleaning walls from inside by chlorine for disinfection for the capacities 25,000 Ltrs & above upto 1.0 Lakh Ltrs for complelte all as specified and directed.
229All as per item srl No. 169 above but for capacities upto 25,000 ltrs. Note - Tanks will be cleaned in 6 stages as given below :- (a) Mechanical dewatering from tank shall be done. (b) Entire sludge in the tank shall be removed. (c) High pressure cleaning of inner surfaces of tanks. (d) Vacuum cleaning of inner surfaces of tanks. (e) Safe effective & eco friendly antibacterial spray (certified by National Toxicology centres) shall be used for spraying on the inner sides of the walls of the tanks. (f) Ultra violate radiation for effective disinfection of inner tank surfaces.
230M & L for painting of valve pit covers on both sides after preparing of old painted surfaces and painting with one coat black paint all as specified and directed.
231S & F in repairs foot valve brass assembly 100 mm dia complete .
232S & F in repairs of Ball type check valve (NRV ) with cast iron body, stainer, nitrile rubber coated ball with Tin bronze seat ring suitable of size 100 mm dia complete.
233S & F in repairs of Ball type check valve (NRV ) with cast iron body, stainer, nitrile rubber coated ball with Tin bronze seat ring suitable of size 150 mm dia complete.
234Dismantling of existing unserviceable motor of following capacitycentrifugal pump set /open well submersible pump set from foundation/inside of sump, split opening into the parts at work shop and repair the motor by rewinding of motor with supper enamelled copper winding wire of suitable gauge/size as exists by replacing paper insulation of class F and fire proof sleeves and varnishing by cleaning of stator slots, assembling complete motor, oiling, greasing,reinstalling and testing complete at site on full load all as directed by Engr-in-Charge.
2353 to 7.5HP motor
23610 to 15HP motor
23720 to 30HP motor
238S&F Lubricated and graphited general purpose asbestos packing on glands of pumpsets of diameter upto 12.5 mm completeall as directed by Engr-in-Charge.
239Dismantling of existing unserviceable motor of followingcentrifugal pump set from foundation painting by synthetic enameled paint one coat after cleaning and preparing surface for painting, reinstalling and testing complete at site on full load all as directed by Engr-in-Charge.
2403 to 7.5HP motor
24110 to 15HP motor
24220 to 30HP motor+B253
243S&F in repair complete set ofpump gasket fitting of suitable sizecomplete all as spd and directed.
244S&F in repairs front ends bearing of same size as existing suitable for pump & motor complete all as spd and directed of following sizes :-
2453 to 7.5HP motor
24610 to 15HP motor
24720 to 30HP motor
248S&F in reparis rear ends bearing of same size as existing suitable complete all as spd and directed of following sizes :-
2493 to 7.5HP motor
25010 to 15HP motor
25120 to 30HP motor
252S&F in repair CI impeller along with lock key for centrifugal monoblock / split casing pumps as per existing suitable for under mentioned pumps complete all as spd and directed.
2533 to 7.5HP motor
25410 to 15HP motor
25520 to 30HP motor
256S&F in repair DOL starter in existing panel suitable for 10 HP to 15 HP 415 volts as per existingincluding wiring from motor to DOL starter with suitable size copper conductor cable complete all as spd and directed. Make-L&T/Siemens/BCH/Havells
257S&F in repair DOL starter in existing panel suitable for 3 HP to 7.5 HP 415 volts as per existingincluding wiring from motor to DOL starter with suitable size copper conductor cable complete all as spd and directed. Make-L&T/Siemens/BCH/Havells
258S&F inreplacement in existing panelautomatic star delta starter suitable for 7.5 to15 HP415 Voltswith relay range upto 15 Amps complete all as specified & directed.
259S&F in repair automatic star-delta motor starter in sheet metal enclosure type ML suitable for 3 phase electric motor of capacity upto 30 HP, 3 phase 415V with relay range 16-25 Amps complete all as specified & directed.
260S&F in repairpower contactor ofcurrent rating upto 60 amps and standard coil voltage240v, 50Hz type ML-3of aux contact (2 NO + 2 NC) including reconnection of cable complete all as specified & directed.
261All as above but ofcurrent rating upto 125 Amps and standard coil voltage240v, 50Hz type ML-6of aux contact (2 NO + 2 NC) including reconnection of cable. complete all as specified & directed.
262S&F in repair General Purpose Load Changeover Switch Confirms to IS:13947 (Part I & III) Onload Changeover Switch - AC 23 (side handle) in sheet enclosure, 415V.4 pole of capacity 400 Amps complete all as specified & directed.
263S&F in repair General Purpose Load Changeover Switch Confirms to IS:13947 (Part I & III) Onload Changeover Switch - AC 23 (side handle) in sheet enclosure, 415V.4 pole of capacity 250 Amps complete all as specified & directed.
264S&F in repair General Purpose Load Changeover Switch Confirms to IS:13947 (Part I & III) Onload Changeover Switch - AC 23 (side handle) in sheet enclosure, 415V.4 pole of capacity 160 Amps complete all as specified & directed.
265S&F MCB TP 16 to 40 Amps, 415 volts complete all as specified and as directed
266S&F in replacement of MCCB 63 Amps to 100 Amps,16 KA,4 Pole,415Vcomplete all as specified and directed. Make - Legrand/L&T/Siemens
267S&F in repair 3 Pole Power Contactors (2NO +2NC) MNX TYPE upto 400Amps complete all as directed.
268S&F in repair 4 Pole Power Contactors upto 100Amps complete all as directed by Engineer-in-Charge.
269S&F in repairs digital voltmeter 0-500 volts square type complete with necessary fixing and 3 nos of CTs all as specified and as directed by Engr-in-charge. Make: L&T/Siemens/Schneider
270S&F in repairs digital ammeter 0-100 amps square type complete with necessary fixing and 3 nos of CTs all as specified and as directed by Engr-in-charge. Make: L&T/Siemens/Schneider
271S&F in repairs Single Phase Preventor complete all as specified and directed.
272M&L rubber gasket joints (Tyton joint)and fittings complete all as specified and directed for thesizes 80/100/150/200/250 mm bore complete all as directed by engr in charge.
273S & F in repairs brass type patti valve ISI marked of following size:-
27415 mm bore.
27520 mm bore.
27625 mm bore.
27740 mm bore.
27850 mm bore.
279Labour only for attending the defect for checking of any type of water supply complaints like No water supply, water leakage, air lock, low pressure, over flow etc. complain including carrying out minor repairs etc as required to make it functional by replacing necessary petty items like rubber gasket, gland, grease, screws, GI tees, band, elbow, nipple and all types / size of CPVC connections etc, complete all as spd and directed by engr in charge. Note:- (i) Attending four number of complaints by plumber and attendant shall be measured as one job. (ii) New materails required to be fixed against old unsv GI fitting shall be measured and paid seperatly. (iii) New materails required to repair/replace against old unsv CPVCfittings of any size shall be deemed to be included in the rate. (iv) One plumbershould be present in complaint cellevery day from 0900 hrs to 1700 hrs.from Monday to saturday (v) failing which will beRs 1000 per day will be levied. Attendence of plumberwill be recorded daily as per direction ofEngr in charge .
280S&F in repairElectronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 20 HP capacity complete all as specified & directed.
281S&F in repairRelay of current range 10 to 16amps, 415 volts suitable for mounted on ML-1.5 and ML-3 Contactors complete all as specified & directed.
282S&F in repairRelay of current range 28 to 42amps, 415 volts suitable for mounted on ML-2 and ML-3 Contactors complete all as specified & directed.
283M&L for servicing/maintenance of air blower machine upto capacity 515/600 M³ per hour with 3 phase upto 20HP 415 volts 50 Hz motor complete with cleaning of air tank including replacement of all defective parts and lubricating oil complete all as specified and directed.
284M&L for cleaning and desilting the sewage lift well of capacity 50 to 100 Cum. Dewatering the complete well, removing All the deposited sludge, soil and other material from the well including balling/ pumping out muddy water from the well by manually or by providing sutiable pump sets from bottom level of well, scrapping out the scales/ deposits from inner surface of the well throughly, washing with bleaching powder and soda ash, cleaning /balling out settled materials completely by any means and removing sludge to a distance up to 3 Km out side of defence land limit and dispose off in low lying area including dewatening as required including whitewash the inner side of sump, painting with synthetic enamel paint colour existing color on outside & writing "Tank cleaned on with 15 cm size white letter on black surface by engaging skilled artist in DD/MM/YYYY format complete all as specified and directed.
285All asser item No 205 above but MBBR tank.
286All as per Ser item No. 205 but STP secondary type settler tank of volume not more than 50 Cum.
287All as per Ser item No. 205 above but STP CC tank/(Chlorine Contact) & Treated water tank. Note for item - Contractor shall arrange his own diesel pump, T&P etc for cleaning purpose and minor spares and consumables like small screws, washers, grease, deemed to be included in the cost. The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc. The unit rate quoted deemed to be include all safety precautions which shall be taken while working in STP tank/ under ground sump. Making good to the damages during the cleaning of the tank is sole responsibilty of the contractor.
288S&F in repairmembrane of size 80 mmx 40 mm complete all as specified and as directed.
289Supply, install test and commissioning of LT distribution panel board suitable for pump &motor compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 2 mm thick with MS angle iron of size 50x50x6 mmto be mounted on floorsuitable to accommodate common bus bar and the following accessories: (a) Onload Changeover Switch -400 Amps, 415V.4 pole-01 No. (b) MCCB TPN 400 Amp 36 KA 415 Volt - 2 Nos (c) Copper bus bar 600 Amps. 4 runs duly coloured PVC sleeve (d) Fully automatic star delta starter suitable for 70 HP pump set 440 V Model MK-1with electric connection - 02 Nos. (e) Fully automatic star delta starter suitable for 15 HP pump set 440 V Model MK-1with electric connection - 01 No (f) Fully automatic star delta starter suitable for 7.5HP pump set 440 V Model MK-1with electric connection - 02 Nos (g) MCCB TP 25 KA200 Amp - 02 Nos (h) MCCB TP 16 KA100 Amp - 01 Nos (j) MCCB TP 16 KA63 Amp - 02 Nos (k) Digital Ammeter 0-600 amps with CT & selector switch - 01 No (l) Digital Voltmeter 0-500 V with selector switch - 01 No (m) RYB lndicating lamp LED type - 01 Set
290S&F in repairfor armoured copper conductor with six core 6 sqmm ,1100 volts grade, PVC insulated, strandedcopper conductor cable suitable for star delta connection with lugs, ferrules etc.complete all as specified and as directed.
291S&F in repair for armoured copper conductor with six core 10 sqmm ,1100 volts grade, PVC insulated, strandedcopper conductor cable suitable for star delta connection with lugs, ferrules etc.complete all as specified and as directed.
292S&F in repair for armoured copper conductor with six core 16 sqmm ,1100 volts grade, PVC insulated, strandedcopper conductor cable suitable for star delta connection with lugs, ferrules etc.complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail