Indian Institute Of Technology-IITB has published Tender For Construction Of Food Outlets Including Development Of Surrounding Area & Drainage System Behind Zanskar Hostel In West Campus At Iit Delhi Sub Head: - Civil And Electrical Works. Submission Date for this Tender is 01-04-2024. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanicalmeans (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
2 | All kinds of soil. |
3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, by mechinical / manual means ramming of bottoms, for all depth, including getting out the excavated soil, and then returning thesoilasrequired,inlayersnotexceeding 20cmindepth,including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: |
4 | All kinds of soil |
5 | Pipes, cables etc, not exceeding 80 mm dia. But not exceeding 300mm dia |
6 | Fillingavailableexcavatedearth (excludingrock)intrenches,plinth.sidesof foundationsetc.inlayersnotexceeding 20cmindepth,consolidatingeach deposited layer by ramming and watering, lead up to 50 m and for all lift |
7 | Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. |
8 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
9 | Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce- ment : 2 coarse sand) to the full depth of the hole : |
10 | With Chlorpyriphos E.C. 20% with 1% concentration |
11 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
12 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
13 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
14 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
15 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
16 | Foundations, footings, bases for columns |
17 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
18 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
19 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
20 | Centering and shuttering including strutting, propping etc. and removal of form for |
21 | Foundations, footings, bases of columns, etc. for mass concrete. |
22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
24 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
26 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth levelup to floor V level in all shapes and sizes in : |
28 | Cement mortar 1:6(1 cement: 6 coarse sand) |
29 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
30 | cement mortar 1:4 (1 cement : 4 coarse sand) |
31 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
32 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters,windowsills,faciasandsimilarlocationsof required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
33 | Granite stone slab of colour black, Cherry/Ruby red |
34 | Area of slab over 0.50 sqm |
35 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
36 | Granite work |
37 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
38 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
39 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
41 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
42 | 125x64x1.90 mm |
43 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
44 | 300x16 mm |
45 | 250x16 mm |
46 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
47 | 300x10 mm |
48 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
49 | 125 mm |
50 | 100 mm |
51 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
52 | Twin rubber stopper |
53 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
54 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. |
55 | With 12 mm mild steel U beading |
56 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
57 | 125 mm |
58 | 100mm |
59 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
60 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
61 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. |
62 | Exceeding 10.00 sqm and upto 16.80 sqm in the area |
63 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured). |
64 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
65 | Hot finished welded type tubes |
66 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
67 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
68 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
69 | 25 mm thick |
70 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
71 | Double charge vitrified tile polished finish of size |
72 | Size of Tile 600 x 600 mm |
73 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
74 | Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
75 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
76 | 110 mm diameter |
77 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitchof corrugationasapprovedbyEngineer-in-Charge)of totalcoated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns.Sheet shouldhave protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
78 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner withsuitably spacedjoints to get requiredlengthandof size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross *T" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for serviceslike diffusers, grills,light fittings, fixtures, smoke detectors etc.Main"1-u runners to besuspended from ceiling using GI slotted cleats of size 27 x 37 x 25 xI.6 mm fixed to ceiling with 12.5 mm die and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
79 | GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
80 | 12 mm cement plaster of mix : |
81 | 1:6 (1 cement: 6 fine sand) |
82 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
83 | 1:6 (1 cement: 6 fine sand) |
84 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
85 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. |
86 | New work (Two or more coats applied @ 1.43 litre) 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
87 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
88 | Two or more coats on new work |
89 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
90 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
91 | Two coats |
92 | Applying priming coats with primer of approved brand and manufacture, having tow VOC (Volatile Organic Compound) content. |
93 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
94 | Demolishing cement concretemanually/ bymechanicalmeans includingdisposalofmaterialwithin 50metresleadasper direction of Engineer - in - charge. |
95 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
96 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
97 | In cement mortar |
98 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
99 | G.S. Sheet |
100 | Disposalofbuildingrubbish /malba /similarunserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond SO m initial lead, for all leads including all lifts involved. |
101 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. |
102 | bituminous portion |
103 | Welded steel wire fabric fencing with posts of specified material andof standard design placed and embedded in cement concrete blocks45x45x 60 cm of mix 1:5:10 (1 cement:5 fine sand : 10 graded stoneaggregate 40 mm nominal size), every 15th post, last but one endpost and corner post shall be strutted on both sides and end post onone side only and struts embedded in cement concrete blocks70x45x50 cm of the same mix, provided with welded steel wire fabricfixed between the posts fitted and fixed with G.I. staples on woodenplugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts,welded steel wire fabric, painting, earth work in excavation andconcrete to be paid for separately). |
104 | Providing and fixing G.I. chain link fabric fencing of required width inmesh size 25x25 mm made of G.I. wire of dia 3 mm includingstrengthening with 2 mm dia wire or nuts, bolts and washers asrequired complete as per the direction of Engineer-in-charge. |
105 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required : |
106 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
107 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink asper IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making goodthe walls wherever required : |
108 | Kitchen sink without drain board |
109 | 610x510 mm bowl depth 200 mm |
110 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. |
111 | Flexible pipe |
112 | 32 mm dia |
113 | Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing : |
114 | Rectangular shape 1500x450 mm |
115 | Providing and fixing toilet paper holder: |
116 | C.P. brass |
117 | Providing and fixing soil, waste and vent pipes : |
118 | 100 mm dia |
119 | Centrifugally cast (spun) iron socket &spigot (S&S) pipe as per IS: 3989 |
120 | Providing and fixing bend of required degree with access door, insertionrubber washer 3 mm thick, bolts and nuts complete. |
121 | 100 mm dia |
122 | Sand cast iron S&S as per IS - 3989 |
123 | Providing and fixing plain bend of required degree. |
124 | 100 mm dia |
125 | Sand cast iron S&S as per IS : 3989 |
126 | Providing and fixing single equal plain junction of required degreewith access door, insertion rubber washer 3 mm thick, bolts andnuts complete. |
127 | 100x100x100 mm |
128 | Sand cast iron S&S as per IS - 3989 |
129 | Providing and fixing terminal guard : |
130 | 100 mm |
131 | Sand cast iron S&S as per IS - 3989 |
132 | Providing lead caulked joints to sand cast iron/centrifugally cast(spun) iron pipes and fittings of diameter : |
133 | 100 mm |
134 | Providingandfixing trapof self cleansingdesign with screwed down or hinged grating with or without vent arm. complete, including cost of cutting and making good the walls and floors: |
135 | 100 mm inlet and 100 mm outlet |
136 | Sand cast iron S&S as per IS: 3989 |
137 | Providing and fixing floor mounted, white vitreous china single piece,double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern ofcapacity 10 litres with dual flushing system, including all fittings andfixtures with seat cover, cistern fittings, nuts, bolts and gasket etcincluding making connection with the existing P/S trap, complete inall respect as per directions of Engineer-in-Charge. |
138 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings withonestep CPVCsolvent cementandthe cost of cutting chasesandmaking good thesame including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
139 | 15 mm nominal dia Pipes |
140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
141 | 20 mm nominal dia Pipes |
142 | 25 mm nominal dia Pipes |
143 | 32 mm nominal dia Pipes |
144 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work |
145 | 40 mm dia nominal bore |
146 | Making connection of G.I. distribution branch with Cl. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: |
147 | 25 to 40 mm nominal bore |
148 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
149 | 45 cm length |
150 | 15 mm nominal bore |
151 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): |
152 | 15 mm nominal bore |
153 | 20 mm nominal bore |
154 | 25 mm nominal bore |
155 | 32 mm nominal bore |
156 | 40 mm nominal bore |
157 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
158 | 15 mm nominal bore |
159 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
160 | 15 mm nominal bore |
161 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
162 | 15mm nominal bore |
163 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
164 | DismantlingoldC.I.pipesincludingexcavationandrefilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead andmaking into blocks,including stacking of pipes at site lead up to 50 metre: |
165 | 1011 mm diameter C.I. pipe |
166 | Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. |
167 | 15 mm nominal bore |
168 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
169 | 250 mm dia. R.C.C. pipe |
170 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement:3coarsesand)finishedwithfloating coat of neat cement and making channels in cement concrete 1:2:4(1 cement 7 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design 7 |
171 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
172 | With common burntclay F.P.S. (non modular)bricks of Class designation 7.5 |
173 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
174 | For pipes 100 to 250 mm diameter |
175 | Dismantling of manhole including R.C.C. top slab, C.I. cover with frame,including stacking of usefulmaterials near the site and disposalofunserviceablematerialswithin 50mleadasper direction of Engineer-in-charge: |
176 | Rectangular manhole 90x80 cm and 45 cm deep |
177 | Constructing brickmasonry road gully chamber 50x45x60 cm withbricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mmpre-cast R.C.C.horizontalgrating with frame complete as per standard design : |
178 | With common burnt clay F.P.S. (nonmodular)bricks of class designation 7.5 |
179 | Providing and fxing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottomandsideswithrequiredEPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
180 | For fixed portion |
181 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
182 | Forshuttersof doors,windows&ventilatorsincluding providing and fxing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
183 | Anodisedaluminium (anodisedtransparentordyedto required shade according to IS:1868, Minimum anodic coating of grade AC 15) |
184 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
185 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
186 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
187 | Upto 5mm depth and 5 mm width |
188 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer- in-charge complete. |
189 | 255 X 19 mm |
190 | Providing and fixing 50 mm thick sandwich roof puff panel (factory made only) as per specification as follow. A) trapezoidal steel sheet having minimum 30mm crest depth, polyester top coat & alkyd backer. Zinc coating shall be 120g/sqm as per IS-277. Top coat polyester 15-18 microns over 5-7 micron epoxy primer. b) Insulation: High density puff insulation. c) Inner sheet: Colour coated galvanized slightly ribbed. Thickness 0.50mm (TCT) minimum 15-18 micron top coat polester coation, zinc coating 120g/sqm as per IS-277 Grade of steel: Minimum 240 Mpa(both sheets). sheet should have protective guard film of 25 micron minimum to avoid scretches during transportations and should be supplied in single lenght upto 12 meter or as desired by Engineer-In Charge. the sheet shall be fixed using self drilling/self tapping screws with EPDM seal, completed upto any pitch in horizontal/ vertical or curved surfaces exccludingthe cost purlins, rafters and trusses and including cutting to size and shape wherever required. work to be executed as per the instructions of Engineer-In- Charge. |
191 | Providing and fixing factory made hot pressed both side laminated flush door ready made shutter with one mm thick decorative laminate on both side confirming to IS:2202 (Part) non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veeneering with vertical grain or cross bands and face veneer on both face of shutters. 35mm thick including ISI marked stainless steel butt hinges with necessary screws. |
192 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, withmodular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
193 | Group A |
194 | Wiringfortwincontrollightpointwith 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required. |
195 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessedsteel conduitalongwith 1No. 4sq.mmFRLSPVCinsulatedcopper conductor single core cable for loop earthing as required. |
196 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessedsteel conduit alongwith 2Nos.4 sq.mmFRLSPVCinsulated copper conductor single core cable for loop earthing as required. |
197 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single core cable in surface/ recessed steel conduit as required. |
198 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
199 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
200 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
201 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
202 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wireinexistingsurface/recessedsteel/PVC conduit including dismantling as required. |
203 | Group A |
204 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required. |
205 | 3 x 2.5 sq. mm |
206 | 3 x 4 sq. mm |
207 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
208 | 20 mm |
209 | 25 mm |
210 | 32 mm |
211 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
212 | 25 mm |
213 | 32 mm |
214 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
215 | 5/6 A switch |
216 | 2 way 5/6 A switch |
217 | 15/16 A switch |
218 | 3 pin 5/6 A socket outlet |
219 | 6 pin 15/16 A socket outlet |
220 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
221 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
222 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. |
223 | 3 Module (100mmX75mm) |
224 | 6 Module (200mmX75mm) |
225 | 12 Module (200mmX150nnm) |
226 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
227 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
228 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
229 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
230 | Group A |
231 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socketoutletand 25 A modularSPMCB,"C"curveincluding connections, painting etc. as required. |
232 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
233 | 100 A, 16 KA,TPMCCB |
234 | 125 A, 16 KA,TPMCCB |
235 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
236 | 12 way , Double door |
237 | 16 way, Double door |
238 | Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) |
239 | 12 way (4 + 36), Double door |
240 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
241 | Single pole |
242 | Double pole |
243 | Triple pole |
244 | Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required. |
245 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB),having a sensitivity current 30mA inthe existingMCBDBcomplete with connections, testing and commissioning etc. as required. |
246 | 63A |
247 | Supplying and fixing followingrating, four pole, (threephase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existingMCBDB complete with connections, testing and commissioning etc. as required. |
248 | 63A |
249 | Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240V"C"curveDPMCBcompletewith connections, testing and commissioning etc. as required. |
250 | Supplying and fixing TP sheet steel enclosure on surface/ recess alongwith 16/25/32 A 415 V"C"curveTPMCBcomplete with connections, testing and commissioning etc. as required. |
251 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
252 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc. as required. |
253 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate havinglocking arrangement and wateringpipe etc. with charcoal/ coke and salt as required. |
254 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
255 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundas strip earthelectrode,includingconnection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
256 | Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. |
257 | Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing as required. |
258 | Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. |
259 | 3.5 X 35 sq. mm (32mm) |
260 | 3.5 X 70 sq. mm (38mm) |
261 | 3.5 X 150 sq. mm (50mm) |
262 | Supplying,installation,testingandcommissioning ofPassive Infrared(PIR)technologybasedoccupancysensorhavinghigh preformance, nonregulatingprogrammabletype,suitablefor connected load upto 10Annp , formountingheightup to 2.8 nntr and for 5 m diameter coverage area alongwith necessary fixing arrangementsi/cprogramming at site etc.complete as required. |
263 | Supplying,installation,testingandcommissioningofmicro processorbasedintelligentaddressablemainfirealarmpanel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries withautomatic charger.Thepanelshallhave facility to connectprintertoprintoutlogandfacilitytohaveseamless integration with analog/digital voice evacuation system (which is part ofthescheduleofworkunderSH:PASystem) andshallbe complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
264 | Two Loop Panel. |
265 | Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetector complete withmountingbase complete as required. |
266 | Supplying,installation,testing& commissioning of response indicator onsurface/recessedMSBoxhavingtwoLED,metallic cover complete with all connections etc as required. |
267 | Supplying, installation,testing&commisssioningofintelligent addressable programmable sounder complete as required. |
268 | Supplying,installation,testing&commissioningoffaultisolator complete with base as required. |
269 | Supplying,installation, testing & commissioning of intelligent addressable thermaldetectorwithrateof risecum fixed tempreature thermistor complete with base as required. |
270 | Supplying,installation,testing&commissioningofaddressable manual call point complete as required. |
271 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
272 | LED Light Fixtures |
273 | Supplying and installation ofRecess/Surface mounting round LED luminaire equipped with die-cast aluminium / CRCAhousing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:-Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage not more than 12 Watts;Output lumens not less than 650 lm; CCT 6000K; Nominal surge protection 2.5 kV;Power factor not less than 0.9; Minimum IP protection54 |
274 | Supplying and installation ofSurface mounting LED Industrial Batten light with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage40 Watts; Length 1200mm;Nominal surge protection 2.5 kV; IP 66. THD<10 %; |
275 | Supplying and installation ofSurface mounting LED Batten light with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage20 Watts; Length 1100-1200mm;Nominal surge protection 2.5 kV; IP 54.; |
276 | Supplying and installation ofSurface mounting Mirror light with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage10 Watts; Length 450-600mm;Nominal surge protection 2.5 kV; IP 54.; |
277 | Supplying and installation ofSurface wall mounting bracketLED bulk head with energy efficient electronic driver with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage10 Watts;Output lumens not less than 1000 lm; CCT 6500K; Nominal surge protection 2.5 kV;Power factor not less than 0.9, IP 66. |
278 | Supplying and installation ofLED flood lightwith energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66, suitable for highlighting architectural facade and general purpose lighting with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage100 Watts; Nominal surge protection 2.5 kV; IP 66. THD<10 % |
279 | Supplying and installation ofLED flood lightRBG with energy saving, environmental friendly, long life, one design for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highlighting architectural facade features or Area lighting and also suitable to rough services/installations, long life, IP66, with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage50 Watts; Nominal surge protection 2.5 kV; IP 66. THD<10 %; |
280 | Supplying and installation ofFlexi LED strip tricolor rope light with high brightness IP65 LED along with uniformity of light required for perfect outdoor application and also suitable to rough services/installations, long life with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage108 Watts; Length 18 mtr;Nominal surge protection 2.5 kV; IP 65. THD<10 %; |
281 | Supplying and installation of25W, LED Post Top fitting IP65 LED along with uniformity of light required for perfect outdoor application, long life, energy efficient, envirnment friendly, with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage25 Watts; Nominal surge protection 2.5 kV; IP 65. THD<10 % |
282 | Supplying and installation of Decorative 8W LED Bollard, Cylinderical / Triangular shape with opel acrylic, minimum 600mm length complete with LED electronic driver with IP65 LED along with uniformity of light required for perfect outdoor application, long life, energy efficient, envirnment friendly, with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage8 Watts; Nominal surge protection 2.5 kV; IP 65. THD<10 % |
283 | Making RCC foundation of size 250mmx250mmx600mm with 1:2:4 (1cement,2coarse,4stone aggregate) complete with 8mm dia MS bar for reinforcement along with centering & shuttering ,3/4 no. suitable dia G.I coated bolt with double nuts, 65mm dia 45cm lengthflexible pvc pipe with excavation the soil & refilling, ramming, curring etc as required. |
284 | Supply & fixing of 65 mm dia."B" class GI pole 3.5 mtr. Long for post top lantern with weather proof box i/c bas plate 300 x 300 x 3mm GI reducer & nipple for mounting the fitting with painting etc. grounting in cement concrete 1: 3: 6 (1 cement : 3 coarse sand : 6 grade stone aggregate 40mm complete as reqd. |
285 | Supplying and installation ofLED High baylightwith energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65, suitable for ceiling mounted( Surface/ suspended) Lighting with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage100 Watts; Nominal surge protection 2.5 kV; IP 65. THD<10 % |
286 | Supplying, installation DLP mini- trunking 32mm x 20mm with independent cover etc. complete as reqd.[Make Legrand] |
287 | PVC mini trunking with independent cover of size 32mm x 20mmsize. |
288 | PVC mini trunking End cap left or right. |
289 | PVC mini trunking Internal/ External angle from 60°-120° |
290 | PVC mini trunking Flat angle from 85°-95° |
291 | PVC mini trunking Flat junction |
292 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. etc. as required [conforming to I.S-1554/1/8] |
293 | 4 X 16 sq. mm |
294 | 3½ X 35 sq. mm |
295 | 3½ X 70 sq. mm |
296 | 3½ X 150 sq. mm |
297 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade in the existing RCC/ HUME/ METAL pipe as required. [conforming to I.S-1554/1/8]. |
298 | 3½ X 35 sq. mm |
299 | 3½ X 70 sq. mm |
300 | 3½ X 150 sq. mm |
301 | supplying and laying and Fixing of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade on wall surface as required.Upto 35 sq. mm (clamped with 1 mm thick saddle)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm [conforming to I.S-1554/1/8]. |
302 | 4 X 16 sq. mm |
303 | 3½ X 35 sq. mm |
304 | 3½ X 70 sq. mm |
305 | 3½ X 150 sq. mm |
306 | Fans. |
307 | Supplying and fixingof 450mm Wall mount fan complete with all accessories for use on 220/240 volts 50 HZ, single phase A/C Supply including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor single/ multi core cable etc as reqd |
308 | Supplying and fixing of250 mm size exhaust fan complete with suitable size louvers with all accessories suitable for use on 230 V , 50 Hz supply in the existing opening, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor single/ multi core cable and making good the damage , testing and commissioning etc.as required. |
309 | Supplying and fixing of300 mm size heavy duty exhaust fan complete with suitable size louvers with all accessories suitable for use on 230 V , 50 Hz supply in the existing opening, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor single/ multi core cable and making good the damage , testing and commissioning etc.as required. |
310 | Supplying and fixing of450 mm size heavy duty exhaust fan complete with suitable size louvers with all accessories suitable for use on 230 V , 50 Hz supply in the existing opening, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor single/ multi core cable and making good the damage , testing and commissioning etc.as required. |
311 | Supplying and fixing fan hook incuding making the arrangement in slab structure to hanging the fan hook including fabrication, welding, painting etc. complete as reqd. |
312 | Supply and installation of SS enclosure duly powder Coated paint for housing incomming MCCB 4P, of appropiate size with incomming and outgoing opening, suitable to accommodate upto 70sqmm, 3.5 core aluminium armoured cable,with louvers for heat dissipation and mounting hole for easy wall mounting. (matter: AC / Normal / Emergency Power) etc. as required |