Tender For Rewiring Of Bsnl Staff Quarters Under Bhubaneswar Ba, bhubaneswar-Odisha

Bharat Sanchar Nigam Limited-BSNL has published Tender For Rewiring Of Bsnl Staff Quarters Under Bhubaneswar Ba. Submission Date for this Tender is 02-04-2024. Electrification Work Tenders in bhubaneswar Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

43027078
Tender For Rewiring Of Bsnl Staff Quarters Under Bhubaneswar Ba
Open Tender
Indian
Odisha
bhubaneswar
02-04-2024

Tender Details

Tender For Rewiring Of Bsnl Staff Quarters Under Bhubaneswar Ba

Key Value

Document Fees
INR 590 /-
EMD
INR 11631.0 /-
Tender Value
INR 5.81 Lakhs /-

BOQ Items

Name of Work:Rewiring of BSNL Staff Quarters under Bhubaneswar BA
Sl. No. Item Description
1Dismantling the old and damaged wirings and cleaning the rooms i/c removal of surplus materials etc. complete as required.
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
3Group-A
4Group-B
5Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
6Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
7Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
82 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
92 X 6 sq. mm + 1 X 6 sq. mm earth wire
104X 10 sq. mm + 2 X 6 sq. mm earth wire
11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
121 x 1.5 sq. mm
132 x 1.5 sq. mm
143 x 1.5 sq. mm
156 x 1.5 sq. mm
162 x 4 sq. mm
173 x 4 sq. mm
184 x 4 sq. mm
192 x 6 sq. mm
203 x 6 sq. mm
21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2220mm
2325mm
2432mm
25Supplying and fixing following size/ modules, GI box (at least 1.2mm thick) along with modular base & cover plate for modular switches in recess etc. as required.
261 or 2 Module (75 mmX75 mm)
273 Module (100 mmX75 mm)
284 Module (125 mmX75 mm)
296 Module (200 mmX75 mm)
308 Module (125 mmX125 mm)
3112 Module (200 mmX150 mm)
32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
33Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
34Supplying and fixing following modular / Piano typeswitch/ socket on the existing modular plate/switch box including connections but excluding modular plate etc. as required.
356/10 A One way Modular switch
363 pin 6/10 A Modular socket
3716/20A Modular switch
386 pin 16/20A Modular socket
39Modular type Bell push
40Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
41Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
42Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
43Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.
44Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.
45Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)
462.25 mfd 440 volts Capacitor for Ceiling Fan
47Bearings forCeilingfans (6201 & 6202) etc. as required. (Make: SKF/SS)
48Ceiling Fan hanging Clamp with nuts and bolts
49Providing 1200 Ceiling Fans for the Officers Quarters i/c installation, connection and testing etc. as required. (Havells Elegant White Or Equivalent of Usha/Bajaj/Crompton)
50Providing 200 polycarbonateExhaust Fans for the Officers Quarters i/c installation, connection and testing etc. as required. (Havells Veltil Air DX HS Or Equivalent make of Usha/Bajaj/Crompton)
51Supplying and fixing ofof factory tested, direct connected type 1 phase 2 wire Digital energy meter of rating 10-60 amp, accuracy class-1.0, suitable for operation on 230/240V (P-N),50 Hz+5% AC supply, operating temperature range from+55 deg C to -10 Deg C, protection class of IP-51 compliance to IS-13779, IEC-62052-11 and IEC-62053-21 with engineering plastic enclosure and provision for sealing of mains and terminal covers, etc.as reqd. (Make L&T EM101/equivalent model of Secure/Siemens)
52Supply and fixing of 32 Amps 240 volts SPN main switch on existing angle frame/surface of wall/board i/c connection etc. as required.
53Replacement of faulty and damaged FTL fittings by new one of following ratings,65000K LED Batten suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells/Phillips / Surya / Polycab / Crompton)
5420/22 watt65000K LED Batten Polycarbonate/Aluminiumbody
5518 watt 6500KLEDpanel (Round/Square) (Trim Clipon LED panel of Havells/SS)
56Polycarbonate Bulk head fitting with 6.5 watt 6000KLED lamp
5715 wattBC LED Lamp
58Angle/batten Holder
59Ceiling Rose
60Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). (Make-Legrand/L&T/Siemens/Schneider)
614 way (4 + 12), Double door
62Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider)
638 way, Double door
6412 way, Double door
65Supplying and fixing 6A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)
66Single pole
67Double pole
68Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6940 A
7063 A
71Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)
7263 A
73100 A
74Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
75Providing and fixing 25 mm X 5 mmG.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with brassnut, bolt, spring, washer excavation and re-filling etc. as required.
76Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
77Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
78Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
79Supply and fixing of following watt LED street light fitting made up of pressure diecast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08. (Make:Havells / Phillips/Crompton/Bajaj)
8030 watt
8145 watt
82Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS)
83Supplying and fixing of 32 mm dia X 1.5metres long G.I. pipe (medium class) bracket along with 2 nos. 40 mm X 3 mm flat iron clamps with nuts, bolts and washers for mounting of street light fitting on pole including bending the pipe to the required shape, painting the clamps with primer and finish paint etc. including cost of all materials as required; complete all as directed by Engineer-in-charge.
84Supply and laying ofService connection cables of 2 core X4sqmm size PVC insulated and PVC sheathed Aluminium conductor weather proof cableetc. as required.
85Supply of the following sizesPVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables.
862 core 6 sqmm
874 core 10 sqmm
884 core 16 sqmm
894 core 25 sqmm
903.5 core 50sqmm
91Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
92Up to 35sqmm
93Above 35 sq. mm and up to 95 sq. mm
94Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
95Up to 35sqmm
96Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
97Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
98Up to 35sqmm
99Above 35 sq. mm and up to 95 sq. mm
100Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmmin the existing Duct/Air as required.
101Up to 35sqmm
102Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
103Replacement of damaged MV cable end terminationswith brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1042 X 6 sq. mm (19mm)
1054 X 16 sq. mm (28mm)
1064 X 25 sq. mm (28mm)
1073½ X 50 sq. mm (35mm)
Disclaimer :