Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : |
| 2 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 3 | Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:4:8 (1 Cement : 4 coarse sand(zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 8 | 1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 10 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.. |
| 11 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 13 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 16 | Suspended floors, roofs, landings, balconies and access platform |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 21 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 23 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 24 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in : |
| 25 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 26 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finishedsmooth. |
| 27 | White Agaria Marble Stone |
| 28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 30 | Kiln seasoned and chemically treated hollock wood. |
| 31 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) -Kiln seasoned and chemically treated hollock wood |
| 32 | 35 mm thick shutters |
| 33 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 34 | Kiln seasoned and chemically treated hollock wood. |
| 35 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 36 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 38 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 39 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 40 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : |
| 41 | 100x58x1.90 mm |
| 42 | 75x47x1.70 mm |
| 43 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. |
| 44 | 300 mm weighing not less than 200 gms. |
| 45 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 46 | 125x64x1.90 mm |
| 47 | 100X58X1.90 mm |
| 48 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 49 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 50 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 51 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 52 | 300x16 mm |
| 53 | 250x16 mm |
| 54 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 55 | 300x10 mm |
| 56 | 250x10 mm |
| 57 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 58 | 125 mm |
| 59 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame. |
| 60 | Providing and fixing to existing door frames. |
| 61 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 62 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 63 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover. |
| 64 | Providing and fixing ball bearing for rolling shutters. |
| 65 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 66 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 67 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 68 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 69 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 70 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 71 | 40 mm thick with 20 mm nominal size stone aggregate |
| 72 | Painting top of roofs with bitumen of approved quality @ 17 kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : |
| 73 | With residual type petroleum bitumen of grade VG - 10 |
| 74 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design |
| 75 | In 75x75 mm deep chase |
| 76 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 77 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 78 | 110 mm diameter |
| 79 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion-Single tee with door |
| 80 | 110x110x110 mm |
| 81 | Bend 87.5° -110 mm bend |
| 82 | Shoe (Plain) -110 mm Shoe |
| 83 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 84 | 110 mm |
| 85 | Providing and fixing Mild Steel pipe clamps of approved design to unplasticised - PVC rain water pipes or S.C.I pipe by means of fasters or 50x50x50mm hardwood plugs, screwed with M. S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 86 | MS clamp for 100mm nominal dia SCI or PVC pipe |
| 87 | MS clamp for 150mm nominal dia SCI or PVC pipe |
| 88 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 89 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: |
| 90 | Gutter (600 mm over all girth) |
| 91 | 12 mm cement plaster of mix : |
| 92 | 1:6 (1 cement: 6 fine sand) |
| 93 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 94 | 1:6 (1 cement: 6 fine sand) |
| 95 | Neat cement punning |
| 96 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 97 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 98 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 99 | Water thinnable cement primer. |
| 100 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 101 | New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 102 | Applying priming coat : |
| 103 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 104 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 105 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 106 | 100 mm diameter pipes |
| 107 | 150 mm diameter pipes |
| 108 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 109 | Two or more coats on new work. |
| 110 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 111 | Two or more coats on new work. |
| 112 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : |
| 113 | New work |
| 114 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 115 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 116 | Two coats. |
| 117 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 118 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 119 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 120 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 121 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 122 | Renewal of old putty of glass panes (length) . |
| 123 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 124 | Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 125 | Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 126 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 127 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. |
| 128 | (a) Internal Work- Exposed on wall |
| 129 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 130 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 131 | 3 mm thick |
| 132 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 133 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 134 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 135 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 136 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 137 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 138 | In cement mortar |
| 139 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 140 | From brick work in cement mortar |
| 141 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 142 | Of area 3 sq. metres and below |
| 143 | Of area beyond 3 sq. metres |
| 144 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: |
| 145 | R.S. Joists |
| 146 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 147 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 148 | For thickness of tiles 10 mm to 25 mm |
| 149 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 150 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 151 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 152 | 100 mm dia pipe |
| 153 | 150-160 mm dia pipe |
| 154 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 155 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 156 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 157 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 158 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 159 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : |
| 160 | Orissa pattern W.C. pan of size 580x440 mm |
| 161 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 162 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 163 | 10 litre capacity - White |
| 164 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : |
| 165 | White solid plastic seat with lid |
| 166 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 167 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 168 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 169 | Flat back wash basin of size 550x400 mm. |
| 170 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete-Flexible pipe |
| 171 | 32 mm dia |
| 172 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 173 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 174 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 175 | Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms. |
| 176 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 177 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 178 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes, weighing not less than 60 gms. |
| 179 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 180 | 20 mm nominal outer dia. Pipes. |
| 181 | 25 mm nominal outer dia .Pipes. |
| 182 | 32 mm nominal outer dia. Pipes. |
| 183 | 40 mm nominal outer dia. Pipes. |
| 184 | 50 mm nominal outer dia. Pipes. |
| 185 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 186 | 40 mm nominal bore |
| 187 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 188 | 45 cm length -15 mm nominal bore |
| 189 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 190 | 40 mm nominal bore. |
| 191 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 192 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 193 | With common burnt clay F.P.S. (non modular) bricks. |
| 194 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 195 | Providing and fixing brass C. P. bib cock of approved quality : |
| 196 | (a) 15 mm nominal bore |
| 197 | Providing and fixing C. P. brass stop cock of approved quality : |
| 198 | (a) 15 mm nominal bore |
| 199 | Providing and fixing C.P. brass health faucet with 1m long hose of approved brand and manufacture and of approved shade |
| 200 | (a) 15 mm nominal bore |
| 201 | Providing and fixing C.P. brass two way bib cock of approved brand and manufacture and of approved shade |
| 202 | (a) 15 mm nominal bore |
| 203 | Providing and fixing C. P. Brass angle stop cock of approved quality. |
| 204 | (a) 15 mm nominal bore |
| 205 | Periodic cleaning of sewer line, sewer manhole, sewer gully chamber and storm water underground line, storm water line inspection pits, storm water road side gully pits etc. by using bamboo/rod for clearing the sewer/storm water line,taking out sludge, debris, rubbish and other waste materials, if any, from the sewer/storm water line and flooding/flushing with sufficient quantity of water with pressure to ascertain through cleaning of drainage system for smooth and proper functioning of sewer/storm water line including disposal of the all waste material outside the municipal limit or burried into pits at safe available distance as directed all complete. (Note-The operation includes cost of all and nothing shall be paid extra on any account). |
| 206 | Underground Sewer line/Storm water drainage line upto 150mm dia |
| 207 | Sewer line/Storm water inspection Pit. |
| 208 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion |
| 209 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 210 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 211 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 212 | Pre-laminated particle board with decorative lamination on both sides. |
| 213 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 214 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 215 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 216 | Grading roof for water proofing treatment with |
| 217 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 218 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 219 | 75 mm average thickness |
| 220 | 50 mm average thickness |
| 221 | 25 mm average thickness |
| 222 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 223 | Bars upto 12 mm diameter |
| 224 | Bars above 12 mm diameter |
| 225 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. |
| 226 | Upto and including 12mm dia. |
| 227 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 228 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 229 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 230 | 25 mm average thickness in 2 layers. |
| 231 | 50 mm average thickness in 3 layers. |
| 232 | Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge. |
| 233 | Wooven PVC cloth |
| 234 | Replacement of sufficiently damaged reinforcements or providing additional reinforcements with the damaged reinforcement by welding etc. including cost of reinforcement(TMT bar of required dia) complete as per direction of the Engineer-in-charge. (Work is to be executed upto 50 m heights above G.L) |
| 235 | Application of SIKA TOP ARMATEK 108 or equivalent@ 0.70kg/sqm(single coat) as approved by the engineer-in-charge and as per manufacture specification for anti corrosion of reinforcement all complete as per direction of Engineer-In-Charge. |
| 236 | Bars upto 12 mm diameter |
| 237 | Bars above 12 mm diameter |
| 238 | Easing door, window shutters with / without removing and refixing the same as per direction of the Engineer - in - charge. |
| 239 | Repairing of damaged door, window shutter i/c dismembering the parts & refixing the same after repairing with same/new screws all complete as per direction by the engineer-in charge (payment of new panels, styles, rails hinges shall be paid in respective item). |
| 240 | Dismantling, removing Chockage & refixing of G.I Pipes up to 50 mm dia and stacked in position as directed. |
| 241 | Providing and fixing oxidised M. S. casement handle for steel window fastener with necessary screws etc. complete. |
| 242 | Easing, oiling and cleaning collapsible gate |
| 243 | Renewing hinge of steel shutter including taking out old one by cutting and fixing new hinges by welding and mending good complete. |
| 244 | Renewing M.S Members of steel shutter by Welding including taking out old ,mending good damages complete, including taking out and refixing glass panes. |
| 245 | Labour for taking out steel windows and refixing the same after replacement of damaged members, hinges etc. including necessary welding etc. Complete after carefully taking out existing glass panes (Payment for new members will be paid for separately). (a). For windows upto an area of 4.00 Square meter and upto floor V level |
| 246 | Supplying of MS steel window members for repairing of damaged steel window as per direction of the Engineer-in-Charge. |
| 247 | Easing, oiling and adjusting i/c scrapping or chiselling which ever is required as per site condition to steel window shutter and fitting so as to make the shutter easily operable for steel window as per direction of the Engineer-in-Charge. |
| 248 | Providing and fixing single scaffolding system on the exterior side of building/structure, upto 20 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 10 cm dia. bamboo ties @0.90 metre apart fitting and fixing with necessary coir,nails etc. horizontal & vertical with working platform etc. and maintaining it in a serviceable condition for execution of work of uprooting plant,other building repairing works etc..of building for external works. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. The scaffolding will be reusable for 19 times and then new scaffolding of similar one will be made. Payment is considered for all the sides of building of first scaffolding used for 19 times and then all new scaffoldings made for the purpose. |
| 249 | Uprooting & removal wild growth & vegetation plants upto girth 100 mm on bldg at any level upto 15m by necessary scaoffolding and swing and providing and applying dilute Hydrochloric Acid on the root all complete as per direction of Engineer in Charge . |
| 250 | Providing and fixing high pressure PVC ball valve (Solvent Weld) of make Supreme or equivalent with pressure class SCH:80 of approved quality including the cost of necessary uPVC socket, pieces of pipes etc. required for the work complete as per direction of Engineer-in-Charge : |
| 251 | 20 mm dia. nominal bore |
| 252 | 40 mm dia. nominal bore |
| 253 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i)Single socketed pipes. |
| 254 | 160 mm diameter |
| 255 | Providing and fixing on wall face unplasticised Rigid PVC pipes of Supreme or equivalent conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 256 | 110 mm diameter |
| 257 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 258 | Plain Bend-160 mm diameter |
| 259 | Shoe (Plain) -160 mm diameter |
| 260 | Door Tee -160 mm diametre |
| 261 | Bend 45° -110 mm bend |
| 262 | Door Bend -110 mm bend |
| 263 | Door Bend -160 mm bend |
| 264 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 265 | 160 mm diameter |
| 266 | Providing and making the joints between PVC pipes & S.C.I./ C.I. Pipes with PVC coupler adhesive/ tapes etc. complete : 110/100 mm dia pipe |
| 267 | Taking out old damage terfelt from existing roof surface without damaging the roof slab and disposal of rubbish witin a lead of 50m and preparation of roof surface with 6mm thick cement morter at damage portion to receive new Tarfelt as per the direction of Engineer in charge. |
| 268 | Cleaning of roof by sweeping all dust, dirt, scrapping the moss and uprooting small plants etc. complete as per direction of Engineer -in- charge. |
| 269 | Removal of telephone cable, furniture and other garbage material stacked adjacent to Main TE building and which is making hinderance to external repair and painting at location shown by authority and as per direction of Engineer in charge. |
| 270 | Credit value for dismantled unserviceable/ serviceable departmental materials: |
| 271 | Style, rail, panel, panelling of wooden door, window etc. |
| 272 | Iron/Steel materials (Flat, Angle, Tee, Channel, Joist, Plate, Sheet, Reinforcement etc.) |
| 273 | 100mm nominal dia cast iron pipe. |
| 274 | Old F.P.S brick |
| 275 | Iron/Steel materials (Flat, Angle, Tee, Channel, Joist, Plate, Sheet, Reinforcement etc.) |
| 276 | Aluminium hydraulic door closer. |