Madhyanchal Vidut Vitran Nigam Limited has published Tender For Repairing And Maintenance Work At Sub Stations And Lines Under Edd-I, Bahraich. Submission Date for this Tender is 01-04-2024. Substation Tenders in bahraich Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Safe carriage, Loading unloading with proper stacking of following material from ESC Bahraich to Work site/Je-Dump Store |
2 | (a) PCC Pole 8.5 Mtr Long |
3 | (b) STP Pole 11 Mtr Long |
4 | (c) Different maintenance material cable, joint Kit, PC Cable ACSR Wire Insulators, Transforme Oil, ABC Cable etc. |
5 | (d) 11 KV HT XLE Cable 3X185 sq mm, 3X120 sq mm, 3X40 sq mm,etc |
6 | Supply and Erection of decentralized items like fuse unit, lugs fuse wire spring contact and other items related ot complete LT Fuse Unit. |
7 | Fabrication, Erection and repairing of damaged wiremess fencing 02 mtr. Height with gate and retaining wall including grouting of fabricatied MS angle 65X65X6 mmwq support and its painting as per specification |
8 | Repairing of damaged massonery transfomer plinth of size as per requirement at site to maintain the height of 1.5 mtr brick bllast, filling of sand in the hollow space, plastening of surface in ration 1:4:6 and top of plinth 4" thckness concealing (including all materials and labour and T&P). |
9 | Repairing of damaged/rusted steel tubular pole by digging of pit up to 2" for proper position putting 3 nos angle from of size 35x35x6 sqmm3 nos angle around the damaged part of pole and welding properly and also grouting and plastering 300 mm iwht cement concrets. |
10 | Erection of sub-station type Double pole on 8.5/11 meter long PCC/ ST Pole along with fixing of necessary clamp/accessories required including fixing of straight M.S 100x50 mm, Top channel 125X65X6 mm (2240 mm long) one no Dopper channel 100X50mm (2028 mmlong)/Angle 100x50 mm 02 nos with arrangement of fixing of 03 nso Pin insulator including sub statin base angle of 65x65x6mm (2250mm) channel 02 earthing is properly as per RESPO specification. |
11 | Laying of 11 KV 3X185, 3x120, 3x240 sq mm XLPE Cable with drlling machine as per norms of UPPCL |
12 | Eraction of single pole PCC Pole 11 Mtr long with all accessories |
13 | Eraction of single pole ST Pole 11 Mtr long with all accessories |
14 | Supply and repairing /replacement of damaged tailles fuse unit/materials of LT distribution piller box wht clamping lug of required size of LT PVC |
15 | (a) 500 Amp, 600 Volts |
16 | (a) 300 Amp, 600 Volts |
17 | Resagging of existing LT/HT line opening of ACB on service point and opening of consumers service cable after re-sagging of ABC re-connection of consumers service able with LT lien (In breakdown time man power has been provided 24 Hours) and cutting/chopping of tree branches and clear from existing LT/HT line to reduce the tripping/breakdown. |
18 | Providing chemical earthingof eisting 250/400/630 KVA transformer by boaring 7lowering 2" electrode and put chemical for improve earthing resistance below than 1 OHM and connectinof transformet body and neutrl with GL Stip. |
19 | Supply and errection tighting and replacing of damage LT lead Lugs and copper L-pies od D.T of capacity 250,400&630 KVA |
20 | Grouting and nozzeling of stay set complete 16x1800 mm.sp with cement concreat sand brick blast. |
21 | Re-grouting cable and laying cabnle during breakdown period/faults on main road etc |
22 | Top-up distilled water in battery bank time to time and maintain DC Supply for healthy tripping also maintained water dwnsity |
23 | Shifting of transformer from one plinth to another plinth and installed trolly with the help of crane during repairing of plith. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy