Tender For Augmentation Of The Electrical Installation By Sitc Of Transformer Ht Lt Panels And Allied Works At Incubation Centre Iit Patna, patna-Bihar

Indian Institute Of Technology-IITB has published Tender For Augmentation Of The Electrical Installation By Sitc Of Transformer Ht Lt Panels And Allied Works At Incubation Centre Iit Patna. Submission Date for this Tender is 04-04-2024. Electrical Maintenance Tenders in patna Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

43017215
Tender For Augmentation Of The Electrical Installation By Sitc Of Transformer Ht Lt Panels And Allied Works At Incubation Centre Iit Patna
Open Tender
Indian
Bihar
patna
04-04-2024

Tender Details

Augmentation Of The Electrical Installation By Sitc Of Transformer Ht Lt Panels And Allied Works At Incubation Centre Iit Patna

Key Value

Document Fees
Refer document
EMD
INR 157000.0 /-
Tender Value
INR 78.50 Lakhs /-

BOQ Items

Name of Work: Augmentation of the Electrical installation by SITC of Transformer, HT/LT Panels and allied works at Incubation Centre, IIT Patna.
Sl. No. Item Description
1Incubation Centre Electrical work
2Supply, installation, testing and commissioning of 800 kVA 11/0.433kV Transformer (at notmal tap) with OLTC, Vector group Dyn-11, Copper Wound, Out door type, Frequency-50 Hz (+/- 5%), 3 phase, Type of cooling- ONAN, Core material CRGO and other criteria like, various indicators, % impedance, tap changer, cable end box, and other accessories shall be as per tender document and conforming to IS: 11171: 1985, CPWD Specification and latest ECBC code. NOTE : - Technical data sheet shall be got approved from Eng-in-charge before manufacturing.
3Design, Supply, erection, testing and commissioning of HT Panel with vacuum switchgear unit with Numerical relayeach panel should have 11kV, 3 pole, 50Hz, 630 amps,metal clad, drawout type vaccum circuit breaker withsingle phase motor operated & also manual spring charging system with Power pack and MFM with RS 485 communication facilities for VCB unitas per specification, drawing , tender document and CPWD Specification. ( Location- SS#2 -01 No, and Incubation centre SS -01 NoNOTE : - Technical data sheet shall be got approved from Eng-in-charge before manufacturing.
4Supply of 11kV, 3 core,stranded 3 core95 sq mm aluminium conductor XLPE insulated,A2XFY, PVC bedded, galvanized flat steel/strip armoured and overall XLPE sheathed screened cable conforming to IS:7098 part II with latest amendments.
5Laying of one number following size PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Cable Upto 3Core 120 sq. mm.
6Laying of one no,11kV, 3 core up to 120 sq mm PVC insulated and PVC sheathed / XLPEpower cable of 11 KV gradein the existing RCC/HUME/ METAL pipe as required.
7Providing and making indoor type end termination for 11kV 3 core aluminium conductor XLPEinsulated cable with supply and using ofHeat Shrinkable type end termination Kits, 11kV insulation tape, Terminal connection earthing, identification tags and making connection to Switchgears, Transformers, Bus bars etc inclusive all hardware as required for the following cables. 3 core 50 sq mm to 95 sq mm
8L.T cable Supply of 1.1 kV grade XLPE insulated, overall sheathed stranded aluminum conductor flat steel strip armoured cable conforming to IS: 7098 Part-1with latest amendments. 3.5 core 400sq mm
9Laying of one no MV cable Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering andrefilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
10Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
11Supply and laying of 100mm dia GI pipe Medium class through road after rilling/boring/ cutting the road 2.5 to 3 mts depth from road surface without damaging the upper portion of road and menking good the damaged areas including supply of pipe.
12Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 Core X 400 sq. mm
13Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. (For Transformer Neutral)
14Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.(For Transformer Body -02Nos +Panel Body -02Nos +PCC panel Body 02No)
15Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
16Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
17Design, Supply, erection, testing and commissioning of LT PCC PANEL withIncomer- ACB 1600 AMP,4P,50KA -02 nos ( with mechanical and electrical interlock facility) Outgoing----i)MCCB 630A,4P,36KA -12 No ii) MCCB 400 A,4P,36KA-2 Nos, iii)160A MCCB,4P,25KA -02 Nos, This panel comprising with BUSBAR -1600 A ACB,4P,50KA, MFM ( Incommer) , Digital Ammeter (All O/G) and indication lamp for each ACB& MCCBs. .The I/C unit should also have Digital type Voltmeter, Ammeter &, C.T with selector switches apart from MFM. All C.Ts should be cast resin type as per specification, drawing , tender document and CPWD Specification. NOTE : - Technical data sheet shall be got approved from Eng-in-charge before manufacturing.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail