| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-04-2024 | Addendum-3 | Date | 06-05-2024 |
| 2 | 19-04-2024 | Addendum-2 | Date | 29-04-2024 |
| 3 | 10-04-2024 | Corrigendum-1 | BOQ | 18-04-2024 |
| Sl. No. | Item Description |
| 1 | GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. |
| 2 | Composite Works |
| 3 | Mechanical and Piping Works |
| 4 | SECTION-A SS TUBE and FITTING - SUPPLY, LAYING and TESTING |
| 5 | Laying, testing and commissioning of SS tubes along with fittings as per Technical Specification, Typical P and ID for type of CNG s tation and scope of work, handling, lifting, transportation from stores toCNG stations. |
| 6 | 3/4inchOD X 0.095inch min Wall thk.SS TubeReferTS Section III - A |
| 7 | 1/2inchOD X 0.083inch min Wall thk.SS TubeReferTS Section III - A |
| 8 | SUPPLY OF SS TUBES as per Technical Specification |
| 9 | 3/4inchOD X 0.095inch min Wall thk.,Material SS316SS TubeReferTS Section III - A |
| 10 | 1/2inchOD X 0.083inch min Wall thk.,Material SS316 SS TubeReferTS Section III - A |
| 11 | Supply of SS Fittings,ValvesQuick Connect Body and Stem |
| 12 | QRC of 3/8inch NPT , end connection 1/2inch Tube OD, for stem and 1/2inchNPTFfor body MaterialSS316Rated pressure 5000 PSIat 70degreeF Temperature0degreeF to 400degreeF |
| 13 | Plug |
| 14 | Size 1/2inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 15 | Size3/4inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 16 | Caps |
| 17 | Size 1/2inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 18 | Size3/4inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 19 | Union |
| 20 | Size3/4inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 21 | Size 1/2inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 22 | Reducing Union |
| 23 | Tube OD 3/4inch x Tube OD 1/2inch, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 24 | Equal Tee |
| 25 | Size 1/2inch OD x 1/2inch OD x 1/2inch OD, Material SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degre eF |
| 26 | Size3/4inch OD x3/4inch OD x3/4inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 40 0degreeF |
| 27 | Reducing Union Tee |
| 28 | 3/4inch OD x 1/2inch OD x3/4inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 29 | Tube End Connection |
| 30 | 1/2inch Tube End and3/4inch OD with Ferrule Fitting, SS316Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400de greeF |
| 31 | Nut |
| 32 | 3/4 inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 33 | 1/2inch OD, Material SS316 Rated pressure 6000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 34 | Front Ferrule |
| 35 | 3/4inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 36 | 1/2inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 37 | Back Ferrule |
| 38 | 3/4inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 39 | 1/2inch OD, Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 40 | Male Connector |
| 41 | Size1/4inch NPTMx 3/8inch OD, SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 42 | Size 1/2inch NPTMx 3/8inch OD, SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400degreeF |
| 43 | Cross |
| 44 | 3/4inch OD X 3/4inchX 3/4inch OD X3/4inch OD Material SS316 Rated pressure 5000 PSI at 70degreeF Temperature 0degreeF to 400 degreeF |
| 45 | SS Ball Valves, conforming to Technical Specification No. MEC/TS/05/62/048 for SS Ball Valves of following sizes, specifications as indicated below |
| 46 | 2-Way Floating Normal Bore Ball Valve3/4inch |
| 47 | 2-Way Floating Normal Bore Ball Valve 1/2inch |
| 48 | 3-Way Trunnion Mounted, Reducer BoreBall Valve 1/2inch OD end Connection and1/4inch NPTFbottom end connection |
| 49 | Conductive Core Thermoplastic Hose |
| 50 | 3/8inch ID Conductive Core Thermoplastic Hose for CNG Service with break away coupling 3 Meter |
| 51 | \"Supply , Laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers and fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of workincluding handling, storage,lifting, trans portation upto CNG stations. Note Total no.offerrule fittings may be considered as one jointing ferrule at every 5.0 m \" |
| 52 | 1/4inchOD X 0.035inch min Wall thk.SS TubeReferTS Section III - A |
| 53 | SECTION-B ERECTION OF MECH. EQUIPMENT |
| 54 | Handlingincluding lifting and transportation from Client\"s store within city toCNG stations and erecting in position, the foll owing equipmenteither on the foundation at Ground level or on roof at 3.5 m above ground level.Contractor\"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. |
| 55 | Cascade 4500/3000 L water capacity. Erection at + 4.0 M levelReferTS Section III - B |
| 56 | Cascade 4500/3000 L water capacity, Erection at + Ground levelRefer TS Section III - B |
| 57 | Dispenser Erection at + Ground Level |
| 58 | \"Note The quantities given above against individual items are indicative and shall not be considered to be binding.The quantities may in crease or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate sh all be operated to work out the final payment due to Contractor.\" |
| 59 | \"SECTION-B.1 ERECTION OF MECH. EQUIPMENT TRANSPORTATION NOT REQUIRED \" |
| 60 | Handlingincluding lifting within CNG stationsand erecting in position, the following equipmenteither on the foundation at Grou nd level or on roof at 3.5 m above ground level.Contractor\"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. |
| 61 | Cascade 4500/3000 L water capacity. Erection at + 4.0 M levelReferTS Section III - B |
| 62 | Cascade 4500/3000 L water capacity, Erection at + Ground levelRefer TS Section III - B |
| 63 | Dispenser Erection at + Ground Level |
| 64 | \"Note The quantities given above against individual items are indicative and shall not be considered to be binding.The quantities may in crease or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate sh all be operated to work out the final payment due to Contractor.\" |
| 65 | SECTION-C SUPPLY, ERECTION and COMMISSIONING OF MISCELLANEOUS ITEM |
| 66 | Supply, erection and commissioning of following miscellaneous items as per technical specification and at locationswithin the stat ionsas directed by EIC Fire fighting EquipmentsReferTS Section III - C |
| 67 | DCP -10 Kg |
| 68 | DCP -75 Kgtrolley mounted |
| 69 | CO2 – 4.5 Kgportable |
| 70 | Sand Bucket with stand and canopy4 Nos. on each stand |
| 71 | Wind Socks |
| 72 | SECTION-D SUPPLY AND INSTALLATION OF ABOVEGROUND STEEL PIPING AT CNG STATIONS. |
| 73 | SUPPLY OF ASSORTED PIPE, FITTINGS AND FLANGES |
| 74 | Complete work of supply of pipes, flanges and fittings including all taxes, duties, transportation and inspection charges but not li mited to, the following itemsin accordance with PMSpiping material specification , relevant specifications and drawings indicate d in scope of work indicated in SCC and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.Handli ng including lifting, transportation from Contractor Stores to CONTRACTOR\"s workshop for fabrication and/ or to work site for field fabrication and erection for all piping items supplied by Contractor. |
| 75 | Carbon Steel Pipe |
| 76 | Size Rating/ Schedule |
| 77 | 4inch NB, BEASTM A106, Gr. BCharpy , Seamless, BE S80 |
| 78 | 2inch NB, BE ASTM A106, Gr. BCharpy , Seamless, BEXSXS |
| 79 | 1inch NB, BE ASTM A106, Gr. B, Seamless, PEXSX S |
| 80 | 3/4inch NB, BE ASTM A106, Gr. B, Seamless, PE S160 XS |
| 81 | Flanges |
| 82 | \"Weld NeckB-16.5, A105 Charpy , 125 AARH, RFEnd Thickness to match pipe thickness \" |
| 83 | Size Rating/ Schedule |
| 84 | 4inch NB, RF 300 |
| 85 | 2inch NB, RF 300 |
| 86 | Socket WeldedB-16.5, A105, 125 AARH, SW end to B16.5 |
| 87 | 1inchNB,RF 300 |
| 88 | 3/4inch NB RF300 |
| 89 | Blind FlangesB-16.5, A105Charpy , 125 AARH, RF |
| 90 | Size Rating/ Schedule |
| 91 | 4inch NB, RF 300 |
| 92 | 2inch NB, RF 300 |
| 93 | Blind FlangesB-16.5, A105, 125 AARH, RF |
| 94 | 1inchNB,RF 300 |
| 95 | 3/4inch NB RF300 |
| 96 | Elbow |
| 97 | ELBOW, 90degree ElbowA234, Gr. WPBCharpy , B-16.9, 1.5D , BW |
| 98 | SizeRating/ Schedule |
| 99 | 4inch NB S80 |
| 100 | 2inch NBXS |
| 101 | ELBOW, 45degree ElbowA234, Gr. WPBCharpy , B-16.9, 1.5D , BW |
| 102 | Size Rating/ Schedule |
| 103 | 4inch NB S80 |
| 104 | 2inch NBXS |
| 105 | TeesSeamless |
| 106 | TEE, Equal / Reducing TeeA234, Gr. WPBCharpy , B-16.9, 1.5D , BW |
| 107 | Size Rating/ Schedule |
| 108 | 4inchNB S80 |
| 109 | 2inchNB XS |
| 110 | 4inchx 2inchNBS80 x XS |
| 111 | SockoletA105 ,SW,6000 ,MSS-SP 97 |
| 112 | Size Rating/ Schedule |
| 113 | 4inch x 1inchNBS40 x XS |
| 114 | 4inch x3/4inch NBS40 x S160 |
| 115 | 2inch x 1inchNB XS x XS |
| 116 | 2inch x3/4inch NBXS x S160 |
| 117 | End CapsA 234 Gr. WPBCharpy , BW |
| 118 | Size Rating/ Schedule |
| 119 | 4inch NBS80 |
| 120 | ReducerA234 Gr. WPB, B.16.9 |
| 121 | Size Rating/ Schedule |
| 122 | 4inch NB x 2inch NBS80 x XS |
| 123 | \"Note iThe quantities mentioned above are tentative. iiFor all the supply items mentioned above, procurement shall be made as per specification after due approval of Engineer-in-charg e. \" |
| 124 | Supply of valves |
| 125 | Complete work of supplyof valves including all taxes,duties,transportation and inspection charges but not limited to ,the followin g items in accordance with relevant Specifications and relevant Data Sheets indicated inscope of work indicated in SCC, drawings, specification and instructions of EIC and as perall provisions of the CONTRACT DOCUMENT. |
| 126 | Flanged/ Welded ValvesFull Bore/ Reduced Bore |
| 127 | Plug Valves BW |
| 128 | Size Rating/ Schedule |
| 129 | 2inch NBBW 300 |
| 130 | Ball |
| 131 | SizeRating/ Schedule |
| 132 | 4inch NBBW , FB300 |
| 133 | 2inch NBBW , FB300 |
| 134 | 2inch NBFE ,FB300 |
| 135 | Sockolet Welded ValveBall Valve |
| 136 | SizeRating/ Schedule |
| 137 | 1inch NB SW, FB 800 |
| 138 | 3/4inch NBSW, FB 800 |
| 139 | Complete Carbon Steel aboveground Piping Work with painting including all fittings, flanges and supply of all required gaskets, ventflappers, studs bolts and nuts etc. as described under item 1.0 above |
| 140 | Carbon Steel PipeA 106, Gr. B, Seamless, B-36.10 |
| 141 | Size Rating/ Schedule |
| 142 | 4inch NB, BEASTM A106, Gr. BCharpy , Seamless, BES80 |
| 143 | 2inch NB, BE ASTM A106, Gr. BCharpy , Seamless, BEXS XS |
| 144 | 1inch NB, BE ASTM A106, Gr. B , Seamless, PEXS XS |
| 145 | 3/4inch NB, BE ASTM A106, Gr. B, Seamless, PE S160 XS |
| 146 | \"Note 1Pipe Specification and thickness may vary depending upon availability of pipe.No extra payment shall be made for this. 2All butt welded fittings end shall generally match with connecting pipe wall thickness. However, in case of misalignment, Contrac tor shall have to do end preparation without any extra cost. 3All coupling, nipples stud, bolts, nuts, gaskets and vent flapper etc. as required shall be suplied by contractor but no separatepayments shall be made as it is covered under erection rate.\" |
| 147 | RADIOGRAPHY |
| 148 | Performance of radiographic inspection by gamma radiation as per scope of work and as per specifications in piping of all types and thickness including providing/hiring of all necessary equipments, supply of all consumables, and whatever else even though not expre ssely mentioned but required to perform the work as per specifications and instructions of Engineer-in-Chargefull circle re-radiog raphy of the repaired joint and additional radiography necessitated due to poor performance of contractor\"s welder shall be carried out by the Contractor at his own cost and shall not be paid extra by Company .Radiographs shall be submitted to the Engineer-in-Ch arge for acceptance, whose decision shall be final and binding. |
| 149 | Size |
| 150 | 4inch NB |
| 151 | 2inch NB |
| 152 | \"Note iThe quantities mentioned above are tentative.\" |
| 153 | Aboveground erection of Valves |
| 154 | Handling including lifting and transportation from COMPANY\"s warehouse to CONTRACTOR\"S Stores and/or work site and installation of a ll types of valves, insulating joint, flow tee including assembly of valve accessories,if anyby bolting, threading or welding, s upply and insertion of gaskets, nuts and bolts, nipples, etc. at all elevations of pipe sleepers, supports or overhead on racks, equ ipments nozzle, skid and painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scopeof work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valve wherever requried. |
| 155 | Flanged/ Welded ValvesFull Bore/ Reduced Bore |
| 156 | Plug Valves BW |
| 157 | SizeRating/ Schedule |
| 158 | 2inch NBBW 300 |
| 159 | Ball |
| 160 | SizeRating/ Schedule |
| 161 | 4inch NBBW , FB300 |
| 162 | 2inch NBBW , FB300 |
| 163 | 2inch NBFE ,FB300 |
| 164 | Sockolet Welded ValveBall Valve |
| 165 | SizeRating/ Schedule |
| 166 | 1inch NB SW, FB 800 |
| 167 | 3/4inch NBSW, FB 800 |
| 168 | PRESSURE GAUGES |
| 169 | Supply, installation and calibration of pressure Gauges and their accessories inclusive of supply of necessary piping materials/tubi ngs alongwith all necessary valves and fittings, fabrication and installation of impulse lines/manifolds as per D. S. No. MEC/23H7/0 5/E5/I/001/DS-PG. |
| 170 | STRUCTURAL WORKS |
| 171 | Pipe Supports and Other Structures |
| 172 | Supply, fabrication and erection of all types of pipe supports like clamps, saddle, guide stops, cradles, turn buckles, anchors, T-p ostsstockade/ trestle and pipe bridge for overhead pipingframes for canopy, approach ladders and platforms, crossover, cable tra y supports, etc. including painting suitable for highly corrosive area as per specificationlabour and supervision and complete wor k as per drawings, specifications and instruction of Engineer-in-charge.Bolts, nuts, washers, PVC coated U-clamps etc. for support ing shall be supplied by the Contractor within the rates quoted.These items will not be measured and paid seperately .The work i s to be completed in all respect as per scope of work and specification. |
| 173 | NotesThe quantities indicated above are tentative estimated values and hence are approximate. Final payment will be made based on actual quantities to be certified by the Owner/Owner representative. The cost of MS boltspermanent and service , washers, electrod es, putty, gases, cost of straightening the raw materials, cutting of flats from plates and providing splices, paints, tools, plantsetc., as required for the work shall be deemed to be included in the quoted rates. All handling and transport charges of raw materi als and fabricated structures including double handling, as required, for completion of work in accrodance with time schedule, are d eemed be included in the quoted rates. |
| 174 | PLAIN CEMENT CONCRETE |
| 175 | Providing, laying in position, construction and handing over of PCC in all types of concrete works including levelling courses belowfoundations, mass concrete works, chambers, cable trench, under floors and any other locations which are not covered as part of r espective items of SOR , at all levels and locationsetc complete in all respects as per scope of work, detailed construction dra wings, technical specifications and direction of Engineer-in-charge. |
| 176 | aPCC M-151 2 4 [ 1 Cement2 coarse sand 4 stone aggregate 20 mm nominal size] |
| 177 | Note 1. Rate to include cost of all labour, tools,tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, coarse sand and coarse aggregates, otherminor construction materials, shuttering, staging, shoring/strutting, finishing, etc. with all bye works and sundry works.2. To be read in conjunction with relevent clause of PJS. |
| 178 | Conversion of DBS to Online/Mother Station |
| 179 | Decommissioning of SS tubing, Dismentalling of SS tubing, providing connections with online compressor/cascade/dispenser as requiredincluding installation of fittings and relacement of damaged fittingssupply to be as per relevant SOR item, Retesting of alread y laid tubings, installation of valvessupply as per relevant SOR , providing as build PandID drawings, etc.completing all tubing /mechanical work to complete the conversion of DBS to Online station. Any fresh supply and laying of SS tubing to be paid separatelyas per relevant SOR item. |
| 180 | Disconnecting / reconnecting all air piping/tubing , loading, transportation and unloading of compressor at designated locaationwi thin GA boundary , |
| 181 | Disconnecting all electrical connections with booster compressor/panel/other equipment, relaying/testing of used cables if required,disconnection of earthing grid from compressor/panel/other equipment and recoonection with online compressor, repair of earth elecr odes etc. Any fresh supply and laying of cable/GI strip/earthing electrod to be paid as per relevant SOR |
| 182 | Architectural Works |
| 183 | Supplying and Installing Mandatory Sign made of 4mm thick. ACMAlstrong/ Aludecor/ Alucobondsheets cladded on structural framewor k. Matter/Logo in Retro Reflective SheetingAvery / 3M / equ. Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size and shape, all complete with by works, as approved. |
| 184 | 300mm X 600mm |
| 185 | ELECTRICAL WORKSSUPPLY |
| 186 | Design, engineering, manufacture, shop testing, supply includingpacking and forwarding, transportation, delivery at storage and fr om storage to site of power distribution boardPDBand Lighting Distribution BoardLDB |
| 187 | \"415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076. Dual Incomer 125 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt trip with Electrical inste rlock Auto/Mannualby Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 80 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE with U/V Protection for Booster feeder only Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 188 | \"415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076 . Dual Incomer 100 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt trip with Electrical inste rlock Auto/Mannualby Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 63 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE with U/V Protection for Booster feeder only Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 189 | \"415 V, 36 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076 . Dual Incomer of 400 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripand 63A 4P MCCBwi th Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripwith Electrical insterlock Auto/Mannualby Power Cont actors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 400 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB, 2 Nos 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 190 | \"415 V, 36 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076 . Dual Incomer of 315 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripand 63A 4P MCCBwi th Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripwith Electrical insterlock Auto/Mannualby Power Cont actors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 250 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB, 2 Nos 32 Amp TPN MCB Outgoing with HRC fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 191 | Floor mounted APFC panel of 40KVAR capacitor bank in steps of 4X2.5, 4X5, 10 and 20 capacitor of MIN 10 nos, consisting ofbus ba r chamber, cable alley, incoming FSU ,all outgoing feeder FSUsas specified in tender drg. no. MEC/-----/05/E9/E/1081B and as per s pecification no. MEC/TS/05/E9/076 |
| 192 | Floor mounted APFC panel of 50KVAR capacitor bank in steps of 4X2.5, 4X5, 10 and 20 capacitor of MIN 10 nos, consisting ofbus ba r chamber, cable alley, incoming FSU ,all outgoing feeder FSUsas specified in tender drg. no. MEC/-----/05/E9/E/1081B and as per s pecification no. MEC/TS/05/E9/076 |
| 193 | Floor mounted APFC panel of 10KVAR capacitor bank in steps of 4X2.5capacitor of 4 nos, consisting ofbus bar chamber, cable alley , incoming FSU ,all outgoing feeder FSUsas specified in tender drg. no. MEC/-----/05/E9/E/1081B and as per specification no. MEC/T S/05/E9/076 |
| 194 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 125 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgo ing terminals. |
| 195 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 315 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutg oing terminals. |
| 196 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 400 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 240/150 sq.mm A2XFY cable on incomer terminals andout going terminals. |
| 197 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 100 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgo ing terminals. |
| 198 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and ligh tning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instrum ents, process equipments and pipes/ flanges including all associated civil work with all materialLike Bitumen coatingand labour as per specification and drawings approved by the company in with IS 3043. |
| 199 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
| 200 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
| 201 | GI Strip50X6mm |
| 202 | GI Strip25X3mm |
| 203 | GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved draw ings, specifications and directions of Engineer-In-Charge. |
| 204 | Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon ba sed backfill compound as per IS 3043/IEEE-80. |
| 205 | 25 sq mm green fexible copper wire Approx 10mtrsalong with two nos Clamps harware etc shall be complete including mettalic cover b ox suitable for outdoor,size 400X400X200 in all respect to earthing/ground of LCV at two points. |
| 206 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated , PVC sheathed, FRLS power and control cablesconforming to IS 7098 and specificationof following sizes in trenches/ excavated un der ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
| 207 | 3.5x 150 mm2 A2XFY |
| 208 | 3.5x 120 mm2 A2XFY |
| 209 | 3.5x 50 mm2 A2XFY |
| 210 | 4x 25 mm2 A2XFY |
| 211 | 4x10 mm2 2XWY |
| 212 | 4x 6 mm2 2XWY |
| 213 | 4x 2.5 mm2 2XWY |
| 214 | 2x 1.5 mm2 2XWY |
| 215 | Supply includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, f lame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cable s and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to b e completed in all respects. |
| 216 | Street lighting, integral flame proof well glass fixtureCMIFR approved for Zone-1/2 gas group IIA and IIBwith 100 W LED luminair e with flame proof control gear Model no. FLPW-1095 of Baliga make or equivalent |
| 217 | Supply of Integral flame proof Flood Light fixtureCMIFR approved for Zone-1/2 gas group IIA and IIBwith 100 LED luminaire Baligamake or equivalent |
| 218 | Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head FittingBH/OA/ 124, 1 x LED, 150W of Sudhir make or equivalent, juction boxes etc. as requried. |
| 219 | Street lighting pole 6mtr high GI octagonal poleType BOP-6030 of Bajaj make or equivalentcomplete with bracket, GI clamps for fi xing flame proof control gear box as per standard drawingMEC/SD/05/E9/77/04and specificationMEC/TS/05/E9/077B . |
| 220 | Supply of point wiring as per details in construction drawing and specificationincludesPVC conduits in ceiling, complete wiring including flexible wireFR PVC , switch boxes and switchesANCHOR ROMA make or equivalent , Multi strand Flexible HR PVC insulatedcopper conductor wires/cables for following items- |
| 221 | Light Point |
| 222 | Surface/ recess mounted LED light fixrure with LED lamptype LCTL-18 -CDL of CG make or equivalent . |
| 223 | Industrial Flame proof fluorescent lamp/LED fitting with lamptype EXTL 240 of CG make or equivalent . |
| 224 | Flame ProofCMIFR approved12inch Exhaust Fan.0.25HP motor,1440 rpm.Preferred MakeBaliga, FCG, CGL, Prompt |
| 225 | Socket outlet5/15 Amp combinationof ANCHOR ROMA make or equivalent |
| 226 | Wall mounted fan with electronic regulator Energy efficent, 50W,etc complete in all respect for wall mounting |
| 227 | UPS SYSTEM |
| 228 | Design, supply, packing, forwarding, delivery by equipment supplier at site including commissioning spares as requiredof UPS syste ms as per specification, block diagram and following rating |
| 229 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V- TPN184-2 65V/Ph, output 230 V +/- 1 percent, AC with Bypass supply, Battery Bank ,ACDBIncomer 32A DP MCB and Outgoing 2 Nos. 6A DP MCB an d 6 nos.10A DP MCBand 4.0 hrs. Battery backupVRLA, 12Vand battery capacity shall not be less than 18 KVAhwhere KVAH = batter y AH x 12 V x No. of Batteries . Main input transformer rating Shall not be Less than 9 KVA,As per Block diagram, Specification and Data sheet and shall be complete in all respect. .All interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDBetc20mtr shall be considered between battery bank and UPS panel, 20 mtr cable shall be considered between ACDB and UPS panel and any oth er cable which is not defined here but necessary for satisfactory operation of the UPS system .MakeM/s Hirel, M/s Dubas and M/s Sy nergy Systems |
| 230 | Supply of following sizes ofHDPE Pipein required length ,supply of clamps, small iron structures, spacersplugs, sealent etc. a nd materials complete as per approved drawingsand directions of Engineer-In-Charge. |
| 231 | 50 mm NB |
| 232 | 100 mm NB |
| 233 | Supply of following Hot Dip Galvanized Ladder/Perforated Typecable traysas per IS 2629including bends, tee, crosses,horizontaland vertical splices along with cable tray cover Wherever required for Asthetic look etc. as required including supply of all G.Ihardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge. Perfor ated type, made from 50mm height and 2.5 mm thick sheet steel and galvanized86 micronsof following sizes. |
| 234 | 150mm wide |
| 235 | 300mm wide |
| 236 | Erection Material |
| 237 | Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS sectio n,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applyingone coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structur e as required including supply of all GI hardware materials including all labour and materials complete as required and the directio n of Engineer-in-charge. |
| 238 | For Mother Station Gas Engine |
| 239 | For Mother Station Motor |
| 240 | For ON-LINE Motor |
| 241 | For DBS Motor |
| 242 | Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if requir ed , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electr icity rules. |
| 243 | Shock hazard charts complete with frame and glass |
| 244 | First Aid Boxes |
| 245 | Carbon-di-oxide CO2type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS 3224 With ISI mark , Dis charge horn with bend and wall fixing Bracket With Mfg. Test certificate |
| 246 | Caution boardsDanger, High Volatageincluding supply of necessary clamps, bolts and other hardware. |
| 247 | Single Line Diagram complete in glass frame. Size 600X800mm |
| 248 | Supply ofInsulating Mats 11kV gradeas per IS 15652 - 2006of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete an d as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules. |
| 249 | Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double com pressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and mis c. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
| 250 | For Mother Station Gas Engine |
| 251 | For Mother Station Motor |
| 252 | For ON-LINE Motor |
| 253 | For DBS Motor |
| 254 | Telephone and LAN |
| 255 | Supply of telephone sockets Piano reed Typein recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc asrequired. |
| 256 | Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
| 257 | Supply of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required. |
| 258 | Supply of UTP cableCAT 6 , Make D Link/Amp/Lucent |
| 259 | ELECTRICAL WORKSERECTION |
| 260 | Erection, Testing and Commissioning of power distribution boardPDBand Lighting Distribution BoardLDB |
| 261 | \"415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076 . Dual Incomer 125 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt trip with Electrical inste rlock Auto/Mannualby Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 80 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE with U/V Protection for Booster feeder only Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 262 | \"415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076. Dual Incomer 100 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt trip with Electrical inste rlock Auto/Mannualby Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 63 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE with U/V Protection for Booster feeder only Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 263 | \"415 V, 36 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076 . Dual Incomer of 400 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripand 63A 4P MCCBwi th Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripwith Electrical insterlock Auto/Mannualby Power Cont actors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 400 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB, 2 Nos 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. \" |
| 264 | \"415 V, 36 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cablealley,complete with wiring, indication lamp, ammeter, voltmeter, MFMMulti Function Meteretc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specifie d in technical specification, data sheet and SLD no. MEC/--/05/E9/E/1081A and as per standard Specification No. MEC/TS/05/E9/076 . Dual Incomer of 315 Amp 4P MCCBwith Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripand 63A 4P MCCBwi th Micro processor and based O/C,S/C and E/F RELASE with LSIG and Shunt tripwith Electrical insterlock Auto/Mannualby Power Cont actors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 250 Amp TPN MCCBwith TM based O/C,S/C and E/F RELASE Outgoing with HRC Fuses -2 nos. 32 Amp TPN MCB, 2 Nos 32 Amp TPN MCB Outgoing with HRC fuse 3 Nos. DP MCB 10 Amp with Timer 24HrsAuto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.\" |
| 265 | Floor mounted APFC panel of 40KVAR capacitor bank in steps of 4X2.5, 4X5, 10 and 20 capacitor of MIN 10 nos, consisting ofbus ba r chamber, cable alley, incoming FSU ,all outgoing feeder FSUsas specified in tender drg. no. MEC/-----/05/E9/E/1081B and as per s pecification no. MEC/TS/05/E9/076 |
| 266 | Floor mounted APFC panel of 50KVAR capacitor bank in steps of 4X2.5, 4X5, 10 and 20 capacitor of MIN 10 nos, consisting ofbus ba r chamber, cable alley, incoming FSU ,all outgoing feeder FSUsas specified in tender drg. no. MEC/-----/05/E9/E/1081B and as per s pecification no. MEC/TS/05/E9/076 |
| 267 | Floor mounted APFC panel of 10KVAR capacitor bank in steps of 4X2.5capacitor of 4 nos, consisting ofbus bar chamber, cable alley , incoming FSU ,all outgoing feeder FSUsas specified in tender drg. no. MEC/-----/05/E9/E/1081B and as per specification no. MEC/T S/05/E9/076 |
| 268 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 125 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgo ing terminals. |
| 269 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 250 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutg oing terminals. |
| 270 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 400 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 240/150 sq.mm A2XFY cable on incomer terminals andout going terminals. |
| 271 | Outdoor type dust and weather proof sheet steel2 mm thickenclosed MCCB of following rating for mounting on wall or pedestal. 100 A, 415V, 3 Pole and Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgo ing terminals. |
| 272 | Erection, Testing and Commissioning of 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proofwith hi nged coversheet steel enclosure of approved make having 4 Pole MCCB LSIG /RCCBMCB + ELCBas incoming andSP/DP/TP MCB9KA typ efor out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification a nd the direction of Engineer-in-charge. |
| 273 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
| 274 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
| 275 | GI Strip50X6mm |
| 276 | GI Strip25X3mm |
| 277 | GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved draw ings, specifications and directions of Engineer-In-Charge. |
| 278 | Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon ba sed backfill compound as per IS 3043/IEEE-80. |
| 279 | 25 sq mm green fexible copper wire Approx 10mtrsalong with two nos Clamps harware etc shall be complete including mettalic cover b ox suitable for outdoor,size 400X400X200 in all respect to earthing/ground of LCV at two points. |
| 280 | Laying, termination,glanding, testing of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cablesconforming to IS 7098 and specificationof following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its prope r sealing, cutting of paved area, roads etc. |
| 281 | 3.5x 150 mm2 A2XFY |
| 282 | 3.5x 120 mm2 A2XFY |
| 283 | 3.5x 50 mm2 A2XFY |
| 284 | 4x 25 mm2 A2XFY |
| 285 | 4x10 mm2 2XWY |
| 286 | 4x 6 mm2 2XWY |
| 287 | 4x 2.5 mm2 2XWY |
| 288 | 2x 1.5 mm2 2XWY |
| 289 | Erection, Testing and Commissioning of lighting fixtures,Pole complete with mounting bracket, flame proof/non flame proof, control g ear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all mater ial and labour as per specifications, drawings and instruction of Engineer-in-charge.Work to be completed in all respects. |
| 290 | Street lighting, integral flame proof well glass fixtureCMIFR approved for Zone-1/2 gas group IIA and IIBwith 72 W LED luminairewith flame proof control gear Model no. FLPW-1095 of Baliga make or equivalent |
| 291 | Integral flame proof Flood Light fixtureCMIFR approved for Zone-1/2 gas group IIA and IIBwith 72 W LED luminaire Baliga make or equivalent |
| 292 | Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head FittingBH/OA/124, 1 x LED, 150W of Sudhir make or equivalent, juction boxes etc. as requried. |
| 293 | Street lighting pole 6mtr high GI octagonal poleType BOP-6030 of Bajaj make or equivalentcomplete with bracket, GI clamps for fi xing flame proof control gear box as per standard drawingMEC/SD/05/E9/77/04and specificationMEC/TS/05/E9/077B . |
| 294 | Erection, testing and Commissioning of point wiring as per details in construction drawing and specificationincludesPVC conduitsin ceiling, complete wiring including flexible wireFR PVC , switch boxes and switchesANCHOR ROMA make or equivalent , Multi str and Flexible HR PVC insulated copper conductor wires/cables for following items- |
| 295 | Light Point |
| 296 | Surface/ recess mounted LED light fixrure with LED lamptype LCTL-18 -CDL of CG make or equivalent . |
| 297 | Industrial Flame proof fluorescent lamp/LED fitting with lamptype EXTL 240 of CG make or equivalent . |
| 298 | Flame ProofCMIFR approved12inch Exhaust Fan.0.25HP motor,1440 rpm.Preferred MakeBaliga, FCG, CGL, Prompt |
| 299 | Socket outlet5/15 Amp combinationof ANCHOR ROMA make or equivalent |
| 300 | Wall mounted fan with electronic regulator Energy efficent, 50W,etc complete in all respect for wall mounting |
| 301 | UPS SYSTEM |
| 302 | Erection, Testing and Commissioning by equipment manufacturer at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating |
| 303 | \"3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V- TPN184- 265V/Ph, output 230 V +/- 1 percent, AC with Bypass supply, Battery Bank ,ACDBIncomer 32A DP MCB and Outgoing 2 Nos. 6A DP MCB a nd 6 nos.10A DP MCBand 4.0 hrs. Battery backupVRLA, 12Vand battery capacity shall not be less than 18 KVAhwhere KVAH = batte ry AH x 12 V x No. of Batteries . Main input transformer rating Shall not be Less than 9 KVA,As per Block diagram, Specification andData sheet and shall be complete in all respect. MakeM/s Hirel, M/s Dubas and M/s Synergy Systems.All interconnecting cables amon g UPS, Rectifier, battery stand, ACDB/DCDBetc20 mtr shall be considered between battery bank and UPS panel, 20 mtr cable shall b e considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system .\" |
| 304 | Erection of following sizes of HDPE Pipe including bend route as required length ,clamps, small iron structures, spacersplugs, sea lent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge. |
| 305 | 50 mm NB |
| 306 | 100 mm NB |
| 307 | Erection, Testing and Commissioning of following Hot Dip Galvanized Ladder/Perforated Typecable traysas per IS 2629including b ends, tee, crosses,horizontal and vertical splices along with cable tray cover Wherever required for Asthetic look etc. as require d including all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEnginee r-in-charge. Perforated type, made from 50mm height and 2.5 mm thick sheet steel and galvanized86 micronsof following sizes. |
| 308 | 150mm wide |
| 309 | 300mm wide |
| 310 | Erection Material |
| 311 | Erection, Fixing and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray su pport out of roled MS section,pipes,plates etc including welding, bolting, reveting, necessary anchor bolts and grouting etc paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
| 312 | For Mother Station Gas Engine |
| 313 | For Mother Station Motor |
| 314 | For ON-LINE Motor |
| 315 | For DBS Motor |
| 316 | Erection and Commissioning of the following including necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules. |
| 317 | Shock hazard charts complete with frame and glass |
| 318 | First Aid Boxes |
| 319 | Carbon-di-oxide CO2type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS 3224 With ISI mark , Dis charge horn with bend and wall fixing Bracket With Mfg. Test certificate |
| 320 | Caution boardsDanger, High Volatageincluding supply of necessary clamps, bolts and other hardware. |
| 321 | Single Line Diagram complete in glass frame. Size 600X800mm |
| 322 | Laying and pasting ofInsulating Mats 11kV gradeas per IS 15652 - 2006of 1000mm width, required for maintenance of electrical e quipment in substation as required including cutting to required shape in running length and including all labour and materials etc.complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rul es. |
| 323 | Erection,Commissioning and fixing of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, n ickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supp orting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
| 324 | For Mother Station |
| 325 | For Bus Depo |
| 326 | For DBS/RO/ONLINE |
| 327 | For DCU |
| 328 | Telephone and LAN |
| 329 | Installation,testing and commissioning of telephone sockets Piano reed Typein recess PVC conduit including PVC conduit,telephonesocket,cable,accessories etc as required. |
| 330 | Installation,testing and commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessoriesetc as required. |
| 331 | Installation,testing and commissioning of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required. |
| 332 | Installation,testing and commissioning of UTP cableCAT 6 , Make D Link/Amp/Lucent |
| 333 | All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to ob tain all necessary clearances for charging of installation as per relevant national standards for Mother CNG station. However the of ficial fees towards the approvals shall be reimbursed by the client. |