| 1 | fo|qr uxjh; forj.k e.My&f}rh;] xkft;kckn ds dk;Z{ks= esa fctusl Iyku 2024&25 en esa lseh&VuZdh ds v/kkj ij 11@0-4 dsoh midsUnzksa dk fuekZ.k ,oa {kerko`f} vkfn dk;Z bZ&fufonk }kjk okg~; ,tsUlh ds ek/;e ls djkus gsrqA |
| 2 | Construction of plinth of size 2MX2MX1.5M above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly after that a retaining wall of 9” width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled upto one ft. below the top of the plinth. After this brick ballast shall be provided upto 6” from the earth level and froperrammering shall be done. One no. jaal of 12mm MS Tor shall be fixed in the hollow of the plinth and one ft. thick RCC in 1:2:4 ratio of cement , sand and stone ballast shall be laid on the top of the plinth. The 12mm thick plastering shall be done all around the plinth in ratio 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of the work (This material will be provided by the Contactor). |
| 3 | Fabrication of wire mesh fencing frames of different size fabricate out of MS angle iron of size 3x3x2 Meter. Each frame duly welded and fixing with wire mesh of size 25x25x10 SWG hot dipped galvanized iron within the frame pressed under MS flats of size 40x5mm inside the angle on all four side with help of approx. 20No. Bolts & Nuts of 10mm diameter 45cm legs of frame will be grouted in 1:2:4 cement coarse sand and 20mm gauge stone blast in the size of 0.22x0.22x0.45meter. Each will be painted with one coat of red oxide and two coat of Alluminium paint of approved mark after proper cleaning. Fixing of wire mess fencing around on plinth of T/F with wire gauge 25x25mm, MS Angle 35x35x5mm with gate. |
| 4 | Safe Carriage of 69 No. ST Pole 11 Mtrs. Long, 6 No. ST Pole 9 Meter Long & 114 No. PCC Pole 8.5 Meter Long from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side. |
| 5 | Safe Carriage of 01 No. 100 KVA Transformer & 36 No. 250 KVA Transformer from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side. |
| 6 | Carriage of LT XPLE Cable 1x240 Sq.mm. fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 7 | Carriage of LT XPLE Cable 1x400 Sq.mm. fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 8 | Carriage of ALL XPLE Cable 3.5x240 Sq.mm. fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 9 | Carriage of LT ABC Cable 3x120+1x95+1x16 Sq.mm. fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 10 | Carriage of HT XLPE 11 KV Cable 3x120 Sq.mm. fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 11 | Carriage of ACSR Dog Conductor fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 12 | Carriage of ACSR Weasel Conductor fromPVVNL Store Sahibabad/ Ghaziabad/ Noida to site of work including loading & unloading at both side. |
| 13 | Carriage of line accessories such as 04 No. Cable Box O/D 11 KV 3x120 Sq.mm., 450 Meter LT XPLE Cable 1x35 Sq.mm., 315 No. 11 KV Composite Polymeric PIN Insulatgor, 87 No. 11 KV Composite Polymeric Disc Insulator, 300 No. LT Shackle Insulator with clamp, 35 No. DO Fuse Set 11 KV and 40 No. Earth Rod (2540x20mm), 07 No. LT TVM Meter 5A, 07 No. LT ACB for Transformer and 50 No. Disc Fitting 45KN from PVVNL Store Sahibabad/ Ghaziabad/Noida to site of work including loading & unloading at both side. |
| 14 | Erection, Grouting, concreting & Installation of Double Pole Structure including all the accessories to be mounted on pole and proper completion of work as per requirement of site. |
| 15 | Erection, Grouting, concreting& Installation of Single Pole Structure including all the accessories to be mounted on pole and proper completion of work as per requirement of site. |
| 16 | Earthing work of pole. Complete work as per requirement of site and as per RESPO Norms. |
| 17 | Laying of LT XPLE Cable 1x240 Sq.mm. Proper completion of work as per requirement of site and as per RESPO Norms. |
| 18 | Laying of LT XPLE Cable 1x400 Sq.mm. Proper completion of work as per requirement of site and as per RESPO Norms. |
| 19 | Laying of LT XPLE Cable 3.5x240 Sq.mm. Proper completion of work as per requirement of site and as per RESPO Norms. |
| 20 | Laying of LT AB Cable 3x120+1x95+1x16 Sq.mm. Proper completion of work as per requirement of site and as per RESPO Norms. |
| 21 | Laying of HT XLPE 11 KV Cable 3x120 Sq.mm. Proper completion of work as per requirement of site and as per RESPO Norms. |
| 22 | Laying of ACSR Dog Conductor Proper completion of work as per requirement of site and as per RESPO Norms. |
| 23 | Laying of ACSR Weasel Conductor Proper completion of work as per requirement of site and as per RESPO Norms. |
| 24 | Installation of DO Fuse Set as per RESPO Norms. Complete work as per requirement of site. |
| 25 | Installation of LT TVM Meter 5A as per RESPO Norms. Complete work as per requirement of site. |
| 26 | Installation of LT ACB of Transformer as per RESPO Norms. Complete work as per requirement of site. |
| 27 | Fixing of Cable Box O/D 11 KV 3x120 Sq.mm as per RESPO norms. |
| 28 | PROVINDING AND FIXING Earth Rod size 2540x20 mm |
| 29 | PROVINDING AND FIXING MS Channel 100x50x5 MM. |
| 30 | PROVINDING AND FIXING MS Channel Angle 75x75x6 MM. |
| 31 | PROVINDING AND FIXING Danger Board with Clamp for 11 KV |
| 32 | PROVINDING AND FIXING G.I. Barbed Wire. |
| 33 | PROVINDING AND FIXING G.I. Wire 6 SWQ. |
| 34 | PROVINDING AND FIXING G.I. Wire 8 SWQ. |
| 35 | PROVINDING AND FIXING G.I. Strip of size 25x3 mm |
| 36 | PROVINDING AND FIXING G.I. Strip of size 50x6 mm for Earthing Connection of Transformer. |
| 37 | PROVIDING AND FIXING Nut & Bolt with washer off Size as per RESPO. |
| 38 | PROVIDING AND FIXING ALL. Crimping Lug 240 Sq.mm. |
| 39 | PROVIDING AND FIXING ALL. Lug 70 Sq.mm. |
| 40 | PROVIDING AND FIXING ALL. Lug 400 Sq.mm. |
| 41 | PROVIDING AND FIXING Copper L-Piece 400 Sq.mm. for 250 KVA TF |
| 42 | PROVIDING AND FIXING Tailness Fuse Unit 300 Amp. With complete fitting as per RESPO Norms. |
| 43 | Providing and FIXING Chemical Earthing with Terminal Hole. 8mm. Service Life-Up to 12 Years. Terminal Size. 50mm x 6mm Earthing work upto 10 Feet depth. 90mm Galvanized Iron (GI) Chemical Earthing Electrode. |
| 44 | PROVIDING AND FIXING 11 KV V-Type Steel Cross Arm 65x65x6mm |
| 45 | PROVIDING AND FIXING P.G. Clamps. |
| 46 | PROVIDING AND FIXING M.S. Holding Clamps. |
| 47 | PROVIDING AND FIXING LT Insulating Piercing Clamps 120 Sq.mm. |
| 48 | PROVIDING AND FIXING LT Suspension Clamp with Eye Hook. |
| 49 | PROVIDING AND FIXING Dead End Clamp with Eye Hook. |
| 50 | PROVIDING AND FIXING Stone Pad. |
| 51 | PROVIDING AND FIXING LT Stay Assembly Complete. |
| 52 | PROVIDING AND FIXING 11 KV TPMO with Jaw and Blades. Complete the fitting as per RESPO Norms. |