Tender For Repair Maintenance Building Security Light Fittings Lightening Conductors, Obstruction Light And Maintenance Of Summer Winter Appliances And Connected Works At Jak Li Rc Under Ge 970 Ews, Budgam-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair Maintenance Building Security Light Fittings Lightening Conductors, Obstruction Light And Maintenance Of Summer Winter Appliances And Connected Works At Jak Li Rc Under Ge 970 Ews. Submission Date for this Tender is 18-04-2024. Electrical Maintenance Tenders in Budgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43010437
Corrigendum : Tender For Repair Maintenance Building Security Light Fittings Lightening Conductors, Obstruction Light And Maintenance Of Summer Winter Appliances And Connected Works At Jak Li Rc Under Ge 970 Ews
Open Tender
Indian
Jammu And Kashmir
Budgam
18-04-2024

Tender Details

Repair Maintenance Building Security Light Fittings Lightening Conductors, Obstruction Light And Maintenance Of Summer Winter Appliances And Connected Works At Jak Li Rc Under Ge 970 Ews ; 1 Supply, Laying, Jointing And Testing Of Xlpe Under Groundinsulated, Armoured, Heavy Duty Lt 1100 Volts 4 Sqmm 2 Core Grade Cable With Aluminium Conductor Isi Marked, Laid In Trenches / Pipes, Fixed Topoles / Walls With Suitable Saddle & Glands With And Incl Taking Out The Old Burnt Out Cables Complete All As Specified And Directed. ( Note - Excavation, Earthwork, Sand Cushioning , Protection Pipeand Brick Protection Shall Be Measured Andpaid For Separately ) 2 Description All As Per Item No 1 Above But Of Size 2 Core 6 Sqmm . 3 Description All As Per Item No 1 Above But Of Size 2 Core 10 Sqmm . 4 Description All As Per Item No 1 Above But Of Size 4 Core 10 Sqmm . 5 Description All As Per Item No 1 Above But Of Size 4 Core 16 Sqmm . 6 Description All As Per Item No 1 Above But Of Size 3.5 Core 25 Sqmm . 7 Description All As Per Item No 1 Above But Of Size 3.5 Core 35 Sqmm . 8 Excavationintrenchesnotexc 1.5 M Wideandnotexc1.5 M Indepth Fortakingout Orlaying Ofcable In Soft / Loose Soil Andgettingout Competeallasspecifiedanddirected. 9 Excavationintrenchesexc 1.5 M Wideandexc1.5 M And Not Exc. 3.0M Indepth Fortakingout Orlaying Ofcable In Soft / Loose Soil Andgettingout Competeallasspecifiedanddirected. 10 Returning, Filling Inincludingspreading, Levelling, Wateringandwellramminginlayersnotexceeding25 Cm Complete Allasspecifiedanddirected. 11 Removal Of Surplus Soil To A Distance Not Exceeding50m Where Directed At A Level Not Exc. 1.5M Above The Starting Point Complete Allasspecifiedanddirected 12 Sand Cushioning To Underground Cable Withclean Drysand Locally Available 8Cm Thick Before Laying The Cable And 15Cm Above The Cable, Stretchingand Testing Of Cable Lcomplete Allasspecifiedanddirected. Note : For Payment Purpose , Punned Thickness Shall Be Measured And Paid. 13 Brick Protection With Brickwell Burntlocallyavailablesubclass B Laid Over Sand Cushioningtocableintrenches Withwidthofbrickparalleltothelengthofcable Complete Allasspecifiedanddirected. 14 Supply & Fixing In Repair Cable Junction Box / Distribution Board Ip 65 With Metric Knockouts For Cable Entry Of Size 10 To 25 Sq Mm X 2 Core Including Fastening Clamp With Lt Pole, Box Size : 333 X 233 X 120 Mm ( Or Nearest Higher Size ) Hinged Cover With Locking Arrangements Including With Terminals Tpnstripwith 01 No Mcb Sp 6A Complete Allasspecifiedanddirected. 15 Gi Tubelightgrade Galvanisedwithallfittingsfor Cable Protection50mmbore Including Fixed With Poles Complete Allasspecifiedanddirected. 16 Gi Pipe Bracket Made Out Of Galvanised Iron Tubing 32 / 40Mm Bore ( Dia ) , Light Grade, 1.20 Metre Long Bent To Shape As Per Specified For Fixing Street Light Fitting Including Suitable Size Of Clamps And Applying Two Coats Of Aluminium Paint Over A Coat Of Aluminium Primer Including Taking Down Old Unserviceable Gi Pipe Bracket With Clamps Complete All As Specified And As Directed. 17 Material And Labourin Replacementearthing Complete With Gi Earth Plate 60X60cmx6mm Thick, Burried Directly In Ground ( Earth Pit Not Less Then 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Less Then 1.5 Metre Below Normal Ground Level, Connected Togalvanised Earth Lead Wire 4.0 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Ironas Earthing Lead Or Steel All As Shown In Electrical Plate No.5 And Incl Earth Work, Pcc Pit And Rcc Cover, Watering Pipe 20Mm Dia Medium Grade, Funnel, Wiremesh, Charcoal Dust, 15 Mm Dia Light Grade Protection Pipe And Salt Etc And Connected To Earthing Test Point Incl Necessary Earth Work, Testing Complete All As Specified And As Directed. 18 Supply And Fixing In Replacement Pvc Insulated, Pvc Sheathed Flat Twin Core Cable With Stranded Aluminium Conductor Of Size 2.5 Sqmm 2 Corecomplete All As Specified And Directed. 19 Supply And Fixing In Replacement Pvc Insulated, Pvc Sheathed Flat Twin Core Cable With Stranded Aluminium Conductor Of Size 1.5 Sqmm 2 Corecomplete All As Specified And Directed. 20 Supply And Fixing In Replacement Led Street Light Fitting 45 Watts With High Efficiency Long Life Leds In-Built Replaceable Electronic Driver Complete Housed In Pressure Die-Cast Aluminium Alloy Covered With Polycarbonate Cover With Ip65 Degree Of Protection And Fixing On Existing Bracket Complete All As Specified And Directed. 21 Description All As Per Ser Item No.20 Here-In-Before But Of 60 Watts 22 Description All As Per Ser Item No.20 Here-In-Before But Of 70 Watts 23 Supply And Fixing In Replacement Integral Led Aviation Light Luminaire Comprising Of Yellow Painted Lm6 Aluminium Alloy Housing Polycarbonate Enclosure Complete All As Specified And Directed.Make: Bajaj / Crompton Greaves / Havells / Wipro 24 Taking Down Of Old Unserviceable Street Light Timer Switch Board Of Any Type And Supply, Fixing, Testing And Commissioning Of Street Light Distribution Boards Max Load 6 Kw, Digital 24 Hour Capacity, 230 Volt, Made Out Of Crca Sheet Steel With Front Openable Door Fitted With Necessary Hinges, Door Locking By Panel Lock And Provision For Pad Locking Duly Phosphatized And Powder Coatedand Conforming To Ip 54 Degree Of Protection, Complete Suitable For Wall Mounting / Pole Mounting With Suitable Clamps, Nuts & Bolts Etc, Internally Pre-Wired With Suitable Guage Of Copper Wires And Connecting Up All Incoming And Outgoing Cables With Suitable Cable Glands, Lugs, Nuts, Bolts And Washers Complete Suitable For Accommodating And Including Provision Of Following Switchgears / Components :-A ) Incoming Mcb 40 Amp Spn- 01 No.B ) 3 Pole Contactor 32 Amp - 01 No.D ) Timer Switch Digital Type, 24 Hour- 01 No.E ) Auto / Manual Selector Switch - 01 No. 25 Supply And Fix In Replacement Mild Steel Cross Arms Channel, Bracing, Support, Clamps Etc Fabricated Structured Steel, Sections, Including Nuts, Bolts, Washers Etc And Cutting To Required Length Beat To Any Shape Drilling Holes, Fixed On Poles Or Jointed By Means Of Elect Welding Complete Including Painting With 2 Coats Of Alumunium Paint Over A Coat Of Red Oxide Primer After Preparation Of Surfaces Icomplete All As Specified And Directed. 26 Material & Labour In Replacement Acsr Conductor Any Size From Poles Including Stringing On Lt Poles Complete Including Aluminium Binding Wires, Jumpering, Bindings At Insulators Etc Complete All As Specified And Dirceted. 27 Disconnecting The Buildings Of Loose Overhead Conductors Of Lt Lines From Insulators And Restringing The Same For Proper Sag And Rewinding Including Aluminium Winding Wires, Tapes Etc And Jumpering For Any Type Of Conductor Complete All As Specified And Directed. ( Each Lt Line Oh Conductor Shall Be Measured As Unit Length. ) 28 Supply And Fixing In Replacement Of Insulator Pin Type Porccelain Viterious, White Brown Or Green Insulator Including One Galvanised Mild Steel Spindle, Two Galvinised Washers And One Gi Nut 100 Mm Hight And 65 Mm Dia For 1100 Volt Grade Complete All As Specified And Directed. 29 Supply And Fixing In Replacement Ofinsulator Shackletype Porcelain Viterious, White Brown Or Green Insulator Including One Galvanised Mild Steel Strap, Washers, Insulator Bolts, Washers And Nuts For Working Preasure 100 Mm Hight And 65 Mm Dia For 1100 Volt 115 Mm Dia, Section Of Strap ( 31 X5 ) Mm Dia Of Bolt 14Mm Complete All As Specified And Directed. 30 Supply And Fixing In Replacement Inclerrection Of Steel Tubuler Swage Poles Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts, Screws As Specified Type 410 Sp-31 ( 9.0 Mtr Long ) And Shifting Of Conductors And Insulators Etc Including Painting The Exposed Portion Of The Pole With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer And Interally Through Out Plus Embedded Portion With Two Coats Of Black Bituminous Paint Over A Coat Of Red Oxide Primer. Marking Of Pole Number With Black Paint In Yellow Circle Complete All As Specified And Directed. 31 Material & Labour For Pcc 1:4:8 Type D2 Using 40Mm Stone Aggregate For Pole Foundation Complete All As Specified And Directed. 32 Material & Labour For Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate Including Use And Waste Of Form Work For Pole Coping / Any Description Complete All As Specified And Directed. 33 Material & Labour For Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate Including Use And Waste Of Form Work For Pole Coping / Any Description Complete All As Specified And Directed. 34 Taking Down Aluminum Strip Of Size 20 X 3Mm With Saddles And Fixing Screws Etc. For Roof Conductors And Down Conductors Above Ground And Refixing In The Same Location With New Nuts And Bolts, Screws Of Suitable Size And Length And Connected To Air Termination Rod On Top Of The Over Head Water Tank Of Height Not More Than 30 Metre From Ground Level Complete All As Specified And Directed. 35 S & F In Replacement Copper Strip 20 X 3.15 Mm Having Pure Copper With Saddles Andfixing Screws Etc. For Roof Conductors And Down Conductors Above Groundfor Over Head Water Tank Of Height Not More Than 30 Mtr From Ground Level Complete All As Specified And Directed. 36 S & F In Replacement Air Termination, Single Pointed Copper Rod 12 Mm Dia And 300 Mm Long For Oh Water Tank Of Height Not More Than 30 Mtr From Ground Level Complete All As Specified And Directed. 37 S & F In Replacementtest Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25mm Drilled And Screwed Including 3 Nos.8 Mm Dia 25Mm Long Hex.Head Screw Complete All As Specified And Directed. 38 S & F In Replacement Pvc Conduit Of Any Size From Poles / Wall / Surface Etc And Supply And Fixing Of Pvc Conduit Of Min 20 Mm Dia As Per Is With Connected Supporting Brackets / Clamps For Fixing / Laying On Poles, Floor, Wall Suitable Withexisting Fixtures Etc Complete All As Specified And Directed Complete All As Specified And Directed. 39 M&L For Opening The Unserviceable / Burnt Ceiling Fan 1200 / 1400 Mm Sweep And Cutting Of Old Burnt Copper Windingand Rewinding The Same With Super Enamelled Copper Winding Wire Of Suitable Gauge Including Insulating Material Such As Paper Cotton Sleeves, Varnish, Reassembling, Testing And Connecting For Satisfactory Run, Complete All As Specified And Directed ( Note:- Taking Down / Dismantling Of Ceiling Fan And Refixing After Repair Shall Deemed To Be Include In This Unit Rate. ) 40 Supply And Fixing In Replacement Of Ball Bearing Of The Ceiling Fan ( Any Sweep ) As Per Existing Size Incl Greasing / Oiling, Complete All As Specified And Directed By Engr-In-Charge. Make:- Skf / Nbc 41 Supply And Fixing In Replacement Of Gun Metal Bushes Of Suitable Size For Ceiling Fan Incl Necessary Mechanical Work, Complete All As Specified And Directed By Engr-In-Charge. 42 Supply And Fixing In Replacement Of Flexible Cable, Three Core 0.5 Sqmmpvc Insulated Copper Conductor Cable For Connecting Ceiling Fan, Complete All As Specified And Directed. 43 S & F In Replacement Stepped Type Electronic Fan Regulator Flush Type As Per Exisitng Model On The Existing Board All As Directed. 44 Supply And Fixing In Replacement Capacitor Of Of 2.5 Mfd For Ceiling Fan, Complete All As Specified And Directed. 45 Supply And Fixing In Replacement Capacitor Of 4 Mfd For Exhaust Fan, Complete All As Specified And Directed. 46 Supply And Fixing In Replacement Of Ceiling Fan Blade Set Of Three, Heavy Duty Suitable For 1200 / 1400Mm Sweep Of As Per Existing Make As Direcetd. 47 Supply And Fixing In Replacement Of Pvc Canopy For Ceiling Fan 1200 / 1400Mm Sweep Complete For Existing Various Makes / Model Of Fan, Complete All As Specified And Directed By Engr-In-Charge. 48 M&L In Repair For Opening And Cutting Of Old Burnt Copper Winding Of Exhaust Fan And Rewinding Of Exhaust Fan Motor Of Sweep 450Mm With Super Enamelled Copper Winding Wire Of Suitable Gauge Including Insulating Material Such As Paper Cotton Sleeves, Varnish, Re-Assembling, Testing And Connecting For Satisfactory Run, Complete All As Specified And Directed As Specified And Directed. ( Note:- Taking Down / Dismantling Of Exhaust Fan And Refixing After Repair Shall Deemed To Be Include In This Unit Rate. ) 49 Description All As Per Srl Item No. 48 Here-In-Before, But 300Mm Sweep -Ditto- 50 Supply And Fixing In Replacement Ball Bearing Of Exhaust Fan Of Any Size / Make As Per The Existing, Complete All As Specified And Directed. Make: Skf / Nbc 51 M&L For Painting The Exhaust Fan Including Louvers Of Size 300 / 450Mm Sweep With Two Coats Of Synthetic Enamel Paint After Cleaning And Making The Surface Of Oil / Dust Free, Complete All Asspecified And Directed. 52 M&L For Servicing Of Geyser By Disconnecting The Electric And Water Supply Connections, Dismantling The Geysers Of Any Size, Type & Capacity And Opening The Top And Bottom Cover, Thermostat, Heating Element, Safety Valve, Vent Pipe, Separating Inner & Outer Tank, Removing Glass Wool Insulation Complete And Keeping Aside For Re-Use After De-Scaling Of Inner Tank By Liquid Chemical And With Pressure Water Jet And Assembling Back The Geyser Including Re-Installation On Wall With Studs, Nuts & Bolts Complete And Testing After Reconnecting Electric And Water Connections, Complete All As Specified And Directed. 53 Supply And Fixing In Replacement Heating Element For Geyser Of Capacity 1.5Kw, Ac 230 Volts, 50 Hz ( As Per Sample ) , Complete All As Specified And Directed. Make:-Usha / Bajaj / Havells 54 Supply And Fixing In Replacement Heating Element For Geyser Of Capacity 2.0Kw, Ac 230 Volts, 50 Hz ( As Per Sample ) , Complete All As Specified And Directed. Make:-Usha / Bajaj / Havells 55 Supply And Fixing In Replacement Thermostat For Geyser Of Capacity 25 / 35 / 50 / 100 Ltr ( Long Size ) With Temperature Setting Adjustment Range From 40 To 85°C, Isi Marked, Complete All As Specified And Directed. Make:- Philips / Bajaj / Venus 56 Supply And Fixing In Replacement Geyser Syphon Assembly Set Suitable For 25 Ltr Capacity Geyser, Fixed In Replacement, As Per Existing Complete All As Specified And Directed By Engr-In-Charge. 57 Description Allas Per Item Srl No. 56 Above Butfor 35 Ltr Capacity -Ditto- 58 Description All As Per Item Srl No. 56 Above Butfor 50 / 100 Ltr Capacity -Ditto- 59 Supply And Fixing In Replacement Rubber Gasket For Water Heater Storage Type Of Any Capacity And Suitable As Per The Existing, Complete All As Specified And Directed 60 Supply And Fixing In Replacement Plug Top 15 / 16 Amps For Geyser, Complete All As Specified And Directed. 61 Supply And Fixing In Replacement Pvc Sheathed Three Core Copper Conductor Flexible Wire Of Size 2.5 Sqmm For Connecting Geyser, Complete All As Specified And Directed. 62 S & F In Replacement Sheet Metal Enclosure Spn With A Two Pin And Earth Plug And Socket Complete With One Sp Mcb 20 Amps Complete All As Specified. 63 Supply And Fixing In Replacement Of Safety Valve For Geyser Of 25 / 35 / 50 Litre Capacity, As Per Existing Make Complete All As Specified And Directed 64 Supply And Fixing In Replacement Of Non Return Valve 15Mm Dia For Geyser Of 25 / 50 Litre Capacity, Complete All As Specified And Directed. 65 Supply And Fixing In Replacement Heavy Duty Pvc Connector 600Mm Long 15Mm Dia With Ptmt Nut For Geyser Of 25 / 50 Litre Capacity, Complete All As Specified And Directed. 66 Supply And Fixing In Replacement Copper Inner Tank Of Geyser Capacity 15 / 25 Litre And Refilling Of Glass Wool, Refixing, Connecting And Testing, Complete All As Specified And Directed. 67 Description All As Per Item Srl No. 66 Above Butfor 35 Ltr Capacity -Ditto- 68 Description Allas Per Item Srl No. 66 Above Butfor 50 Ltr Capacity -Ditto- 69 Supply & Fixing In Replacement Stop Cock Brass 15Mm Dia, Complete All As Specified And Directed. 70 M&L For Preparation Of Surface Of Geyser Of Capacity 25 / 35 / 50 Ltr By Scraping, Removing Old Paint Etc And Applying Two Coats Of Synthetic Enamel Paint Complete All As Specified And Directed. 71 Supply And Fixing In Replacement Of Compressor Fo Refrigerator Of 165 To 200 Ltr Capacity As Per The Existingcomplete All As Specified And Directed. 72 Supply And Fixing In Replacement Of Thermostatfor Refrigerator Of 165 To 200 Ltr Capacity. 73 Supply And Fixing In Replacement Of Thermal Relay For Refrigerator Of 165 To 200 Ltr Capacity. 74 M&L For Charging Refrigerant R134a And Testing For Proper Cooling And Leakage Complete For Refrigerator Of 165 To 200 Ltr Capacity All As Specified And Directed. 75 Supply And Fixing In Replacement Of Compressor For Refrigerator Of 210 To 335 Ltr Capacity As Per The Existingcomplete All As Specified And Directed. 76 Supply And Fixing In Replacement Of Thermostatfor Refrigerator Of 210 To 335 Litre Capacity. 77 Supply And Fixing In Replacement Of Thermal Relay For Refrigerator Of 210 To 335 Litre Capacity. 78 Supply And Fixing In Replacement Of Compressor For Deep Freezer Of 210 To 400 Ltr Capacity As Per The Existingcomplete All As Specified And Directed. 79 Supply And Fixing In Replacement Of Thermostatfor Deep Freezer Of 210 To 335 Litre Capacity. 80 Supply And Fixing In Replacement Of Thermal Relay For Deep Freezer Of 210 To 335 Litre Capacity. 81 Taking Out Unserviceable / Burnt Stabilizer Of 3 Kva To 5 Kva Capacity, Rewinding The Same With Super Enamelled Copper Winding Wire Of Suitable Gauge Including Insulating Material Such As Paper Cotton Sleeves, Varnish, Reassembling, Replacement Of Knobs, LedS Etc. And Making Fully Functional On Load As Connected To Refrigerator / Deep Freezer / Ac Complete All Directed. 82 All As Per Item Srl No. 81 Above Butforcapacity 0.25 To 1 Kva-Ditto-

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-