Tender For Additional/Alternator And Special Repair To Cook House And Dining Hall Of B Coy Of No I Trg Bn Aoc Centre Under Ge (South) Secunderabad, secunderabad-Telangana

Military Engineer Services-MES has published Tender For Additional/Alternator And Special Repair To Cook House And Dining Hall Of B Coy Of No I Trg Bn Aoc Centre Under Ge (South) Secunderabad. Submission Date for this Tender is 11-04-2024. Mobile Generator Tenders in secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

43010217
Tender For Additional/Alternator And Special Repair To Cook House And Dining Hall Of B Coy Of No I Trg Bn Aoc Centre Under Ge (South) Secunderabad
Open Tender
Indian
Telangana
secunderabad
11-04-2024

Tender Details

Additional / Alternator And Special Repair To Cook House And Dining Hall Of B Coy Of No I Trg Bn Aoc Centre Under Ge ( South ) Secunderabad

Key Value

Document Fees
INR 500 /-
EMD
INR 87500.0 /-
Tender Value
INR 43.58 Lakhs /-

BOQ Items

Name of Work: ADDN ALTN AND SPECIAL REPAIR TO COOK HOUSE AND DINING HALL OF B COY NO 1 TRG BN, AOC CENTREUNDER GE (SOUTH) SECUNDERABAD.
Sl. No. Item Description
1Demolition of cement concrete in roofincluding existing roof treatement(other than ground floor) and removing debris to a distance of n.exc 100M away from the bldg complete all as specified andas directed.
2M & L for25 mm average thick PCC (1:2:4) Type B0 by using12.50 mm graded crushed stone aggregate as in roofwhere required over slabsand finishing the exposed surfaces faireven without using extra cement complete all as specified and as directed.
3M&L for removal of old treatment of any description and removing the debris roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
4M & L for 10mm thick rendering in CM 1:4 using water proofing compound at the rate of 3% weight of cementor as per manufacutures instruction over concrete surfacescomplete all as specified and as directed. Note : WPCwill be measured and paid separately under relevant item)
5M&L for priming the plastered roof surfaces with bitumenous primer @ 0.30 Kg per sqm and applying APP based polymeric membrane minimum weighing 3 Kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms/per Sqm) and on primed surface by forced applicationover apply bitumen base aluminium paint@ 0.20 Kg/Sqm complete all as specified and as directed.
6Supply only water proofing compound complete all as specified and as directed.
7M & L forcutting grooves in brick wall/roof slab of size 75mm wide 65mm deep and shapping to horizontal face of the groove with cement mortar 1:3 complete all as specified and as directed.
8Taking down rain water pipes of any description any pattern incl all fittings heads, shoes bends etc complete all as specified and as directed.
9S&F PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls or in floors complete all as specified and as directed.
10Dismanting asbests cement ( corrugated, semi-currugated etc.) sheets in roof covering complete all as specified and as directed.
11S & F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPAas in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
12S&F pre painted gal valume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour haing tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
13Dismantlingframed wooden purlin/Rafterwork of any descriptionsectional area exc 40 Sqcm not other wise provided for, complete all as specified and as directed.
14Dismantling wrought iron or mild steel work of any description not other wise provided for. complete all as specified and as directed.
15S & F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A.
16M & L for providing cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed.
17M&L for Preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer complete all as specified and as directed.
18M&L for Preparatioin of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed.
19Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets. complete all as specified and as directed.
20M&L for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mmand aluminium wall angle size 25x25x1.8 mmfixed to wall hanging from soffits\trusses\bracking using adjustable supportinghanger compressing of GI wire 4mm thick with locking clip complete all as sepcified and as directed
21M&L for Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap gridas per manufacturers instructions complete all as sepcified and directed
22Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and as directed.
23M & L for brick work with flyash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
24Taking down plastering on brick walls etc including racking out joints, hacking for key, scrabing down with water etc.complete all as specified and as directed.
25M & L for 15 mm thick rendering in Cement Mortar 1:4 on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cementincl scaffolding if necessary complete all as specified and as directed
26M & L for 15 mm thick rendering in Cement Mortar 1:6 on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement. complete all as specified and as directed.
27M&L forpreprationof newly plastered surface of wall and applying twocoats of cement base paint over a coat of primer complete all as specified and as directed.
28M&L as above for two coats of oil bound distemper over a coat of cement primer cementcomplete all as specified and as directed.
29M&Lfor Preparation of plastered or unplastered old decorated surfaces of wall and applying two coats of oil bound distemper. complete all as specified and as directed.
30M&LPreparation of plastered or unplastered old decorated surfaces and applying two coats of cement base paint on walls. complete all as specified and as directed.
31Taking down chowkat with frame (without taking off shutter from the frame) n exc 1.50 Sqm each complete all as specified and as directed.
32All as per item No 31 above but areaexc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed.
33Taking down shutter of any description not exc 1 Sqm each complete all as specified and as directed.
34Taking down shutter of any description exc 1 Sqm & n exc 2 Sqm each complete all as specified and as directed.
35M & L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
36M & L for 2nd classhard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
37S&F in frame at siteFactory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2, raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face,as per specification & drawing complete all as specified and as directed.
38S&F for 35mm thick factory made plain framed panelled shutter of 2nd class HW (any Number of panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm th venered particle board with veneering on both face kiln seasoned & chemically treated complete all as specified and as directed.
39S & F 35mm thick 2nd class hard wood glazed skeleton shutters open rebated and prepared to receive glass and divided into square with plain, rounded, chamfered, mitred and rebated sash bars.complete all as specified and as directed.
40S & F 30mm thick 2nd class hard wood glazed skeleton shutters open rebated and prepared to receive glass and divided into square with plain, rounded, chamfered, mitred and rebated sash bars.complete all as specified and as directed.
41S & F 100mm long Stainless steelbutt hinges with galvanised aluminium pin.complete all as specified and as directed.
42S & F 100mm butt hinges medium weight cold rolled mild steel complete all as specified and as directed.
43S & F Aluminium handle 150mm fabricated type complete all as specified and as directed.
44S & FAluminium anodised barrel tower bolts 150mmof extrded section complete all as specified and as directed.
45S & F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
46S&F 300 mm long helical door springs including roller plate complete all as specified and as directed.
47S& F for 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor
48S & F in repairs 100mm butt hinges medium weight cold rolled mild steel complete all as specified and as directed.
49S & F in repairs Aluminium handle 150mm fabricated type complete all as specified and as directed.
50S & F in repairs Aluminium anodised barrel tower bolts 150mmof extrded section complete all as specified and as directed.
51S & F Aluminium powder coated frame work for door / windows / ventilators with one or more rebates including joining heat for fixing etc complete all as specified and as directed.
52S & F Aluminium powder coated door shutters, aliminium section weighting 0.55 Kg/M including necessary joinging cleats, galzing clips, ruber neoprene pakcing handles 2 Nos in each door, hinges anodised aliminium snap beading screws etc complete all as specified andas directed.
53S & F galvanized mild steel wire cloth 0.56mm nominal dia of wire with avg 1.18mm width of aperture and fixed with tinned tacks. complete all as specified and as directed.
54All as per item No 53 above but fixed in repairs complete all as specified and as directed.
55S & F 2nd classhardwod in fillets, square, rectanglar in section wrought, secrred with nails sectional area exc 3 sqcmand n exc 6 sqcm fixedin repairs complete all as specified andas directed.
56S & F 2nd classhardwod in fillets, square, rectanglar in section wrought, secrred with nails sectional area exc 13 sqcmand n exc 25 sqcm fixedin repairs complete all as specified andas directed.
57S &Ffor framed work such as grills, grating etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars(for windows); barred iron doors; ladders; framed balusters; walk ways; railings; framework of watertanks and similar work conforming to Fe 290. Gde E-165 complete all as specified andas directed.
58Hacking out old broken glass any description & size from wooden/steel window and removal of rubbish from work site complete all as specified andas directed.
59S & F 3mm th sheet glass ordinary quality and fixed with oil putty in square not exc 0.5 sqm in each panecomplete all as specified and as directed.
60S & F 3mm th figured glass ordinary quality and fixed with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and as directed.
61S&F in repairs 19mm thick block board grade 2 quality, interior grade, commercial type on both faces fixed as in shutter/shelves of cup boards etc complete all as specified and as directed.
62S&F in rep door closure hydraulically regulated disignatin No 3 universal type suitablefor door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
63M & S for preparation of new wooden surface and applying 2 coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified and as directed.
64M & L for preparation of old wooden surface and applying 2 coats of synthetic enamel paint over 10cm width or girth complete all as specified and as directed.
65Demolition of cement concrete(unreinforced) in ground floors and pavingnexc 15 cm thickness (below and above ground level) complete all as specified and as directed.
66M&L for cement concrete 40mm thick type B- 1, 1:2:4 (using 20mm graded crushed stone aggregates) as in floor finishing cement concrete surface even and smoothwithout using extra cement complete all as specified andas directed.
67M&L for forming 38mm wide construction joints Glass dividing strips, 3 mm thick complete all as specified andas directed.
68M & L for 75mm thickPCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and as directed.
69M & Lfor 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed.
70M&L for chequered cement concrete tiles with grey cement and pigments of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified and as directed.
71Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and as directed.
72M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) finished fair & even as in Sub base flooring complete all as specified and as directed.
73M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm , as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
74M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
75M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exc 0.06 and not exceeding 0.11 Sqmin floors surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
76M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile exceeding 0.42 but n exc 1.00 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6.complete all as specified and as directed.
77M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile exceeding 0.42 but n exc 1.00 sqmin skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl10mm thick rendereringin CM 1:4.mm complete all as specified and as directed.
78S&F in repair rotational moulded polyethylene water storage tanks 1000 ltrs(cylindlerical vertical with closed top) hoisted and fixed in position all as specified in SSR part I inclding dismantaling of existing damaged water tanks complete all as specified and as directed.
79S&F 20 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified and as directed.
80S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) 20mm bore complete all as specified and as directed.
81S&F 15 mm bore tubes medium grade, galvanized with all fittings and fixed complete to walls and ceiling or laid in floors includingtaking down complete all as specified and as directed
82S&F 20mm bore tubes medium grade, galvanized with all fittings and fixed complete to walls and ceiling or laid in floors includingtaking down complete all as specified andas directed.
83S&F 15mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screweddown, screwed foriron pipe or for brass ferrule and fixedin repairs complete all as specified andas directed.
84S&F in repair 15mm bore pillar tap cast copper alloy with capstan head ,chromium plated screwed down high presure with or with out lettered fixed with iron pipe complete all as specified andas directed.
85S&F in repairs Bib taps 15mm standard of PTMT and any colour screwed for iron pipe complete all as specified andas directed.
86S&F in repairs stop cock 15mm dia cast copper alloy with crutch or butterfly handle, screweddown, screwed foriron pipe or for brass ferrule and fixedin repairs complete all as specified andas directed.
87S&Fin repairWHB vitreous china (flat back or angle back type ) ,including cutting for pinning in ends size 550x400 mm including brackets ,waste pipe ,coupling ,PVC connection, wastepipe and CP piller tap complete. complete all as specified andas directed.
88S&F in repair 600mmx450mm belvelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood with pvc / alluminium frame and fixed to wooden plugs with chromum plated brass screws cup washers. complete all as specified and as directed.
89S & F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
90Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified andas directed.
91Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified andas directed.
92Removing the excavated soil to a distanceexc 250.0 m and n.exc 500 .0m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified andas directed.
93M&L for cement concrete in foundation filling and mass concrete type D2 1:4:8 (using 40mm graded crushed stone aggregate) complete all as specified andas directed.
94Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)
95M&L for Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate ) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4) complete all as specified andas directed. Note:- Reinforcement will be measured and paid separately
96S & F MS TMT bars 10 mmdia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
97Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
98Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
99M & L for Concealed Conduit Point wiring with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1 mm thick MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc complete all as specified and as directed. (a) One light point controlled by one, one way switch 5A, SP
100(b) One ceiling / exhaust fan point controlled by one, one way switch complete all as specified and as directed.
101(c)One 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
102(d) One 3 Pin 5 Amps switch socket Independt board complete all as specified and as directed.
103Description all as per item No 3 here-in-before but using 4 Sq mm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 5/15 Amps switch socket combination point including running of 4 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
104S & F Switch pianotype single pole one way flush type 5 Amps capacity 230 volts complete all as specified and as directed.
105Supply and fix switch socket combination flush type multipurpose 2/3 pin5 Amps, 230 Volts complete all as specified and as directed.
106Supply and fix socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts complete all as specified and as directed.
107Supply and fix switch socket combination flush type multipurpose 5 in 1,5/16 Amps, 230 Volts complete all as specified and as directed.
108S & Fix ceilingfan regulator step socket type AC 240 voltsuitable for 1200 mm sweep complete all as specified and as directed.
109S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed.
110S & F Vertical loadline type TPN DB 4 way double door with fixed magnetic setting of suitable current rating of(MCCB 100 A TP volts AC 3 phase50 Hz ) confirming to IS specification made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed.
111S & F Horizontal type TPN DB 4 way double door made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed. .
112S and F sheet metal enclosure MCBDB SPN 8 way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed.
113S & F MCB SP230V suitable for fixing on MCB DB of capacity 6 to 32 Amps complete all as specifiedand as directed
114S & F MCB SPN230Vsuitable for fixing on MCB DB of capacity 63 Amps complete all as specified and as directed.
115S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and as directed
116S & F Triple pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps (AC Box) complete all as specified and as directed
117M & L for Submain wiring with two single core 6 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through andincluding rigidPVC conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly completeincludingremovingtheexistingunserviceablesubmain wiringandmakinggood thedisturbed surfaceto match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length.
118M & L for Submain wiring with two single core 4 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through andincluding rigidPVC conduit and conduit accessories of 25 mm dia medium grade including running up of 4Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly completeincludingremovingtheexistingunserviceablesubmain wiringandmakinggood thedisturbed surfaceto match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length.
119M & L for Submain wiring with 4 runs of single core 6sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed. Note :Four runs of cable,one run of earth wire in existing conduit will be measured as one unit .
120M & L for Submain wiring with 4 runs of single core 10sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 10 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note Four runs of cable,one run of earth wire in existing conduit will be measured as one unit complete all as specified and as directed.
121S & F wall mounted box type LED of 18/22 watt with LED Lamp,with 2 Nos round blocks with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor multistranded three core of suitable length & size from fitting to the ceiling rose complete all as specified and as directed.
122S & F 36 watt recess softline luminaire (2x2) suitable for armstrong/grid ceiling with high brightnesswhite LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal and all including taking down a complete all as specified and as directed.
123S & F wall mounted LED batten of 09 watt with LED Lamp,complete all as specified and as directed.
124S & F 9 Watt LED Bulb with lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and as directed.
125Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth earth lead 4 mm dia, by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe med grade 15mm bore from earth elelctrode to test pointincl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipemed grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade.
126Disconnecting and removingceiling fan of 1200/1400 mm sweepany height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants includingreassembling, includingreplacement of wornout/defective parts, capacitor 2.5 mfd capacity 240 volts, sealed ball bearing, rubber bushes and refixing in original position includingminor repairs,for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan includingpainting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc & testing complete and following items changed in place of unservericeable parts including Material and labour for rewinding of the ceiling fan complete with equivalent new super enamelled copper wire of existing gauge and weight as per manufacturer"s design and instructions including varnishing for ceiling fan of any make and any sweep complete all as specified and as directed. including taking out burnt copper wire. Note: old winding material is property of the contractor complete all as specified andas directed.
127Supply & fix Exhaustfan of metal body450 mm sweep with metallic louver includingconnecting up ofPVC insulated copper conductor multi stranded cable of suitable size as recommended by the manufacturer from ceiling rose to connector complete including provision of HDPE high grade plastic net 800 GSM,hole size one inch,thickness 3mm green colour on the outside wall complete all as specified and as directed.
128M&L for cutting of wall in round shape irrespective of height of building using machine cutting only and making opening suitable for mounting of 450 mm dia exhaust fan and making good disturbed surfacesmatching with existing colour including grouting of nuts and bolts and clearing the debris and making the work area clean complete all as specified andas directed. Note: Contractor to check the site requirement.
129S&Fcable TV co-axial socket outlet point including conduit 20mm dia upto 15m long to reach out the intake point complete all as specified and as directed
130S&Fcable Telephone socket outlet point including conduit 20mm dia upto 15m long to reach out the intake point complete all as specified and as directed
131Supply and fixing metal type vertical mounted electric water heater , storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 stars rated complete with all accessories such as safety valve, vaccum and pressure release valve and snap action thermostst , thermal cutout , non return devices, 240 volts with plug top, confirming to IS complete all as specified and as directed.
132Supply and laying steel water tubing , medium grade, galvanised of size 15 mm bore , ISI marked including all ISI marked fittings such as tees, bends, elbow, reducers, unions etc fixed complete to walls and ceilings or laid in floors complete including cutting the existing pipe of any size complete all as specified and as directed.
133Supply and fix gun metal gate valve ISI marked cast copper alloy screwed down high pressure with crutch or butter handle screwed both ends for iron pipe or for union and fixed suitable for pipe 15 mm bore complete all as specified and as directed.
134S & F PVC connecting pipe 45 cm long with two no.s brass check nuts and rubber washers suitable for 15 mm dia GI pipe for hot/cold water connection for geysers complete all as specified and as directed.
135S &F Bib taps chromium plated with crutch or butter fly handle 15 mm dia screwed for iron pipe or for brass ferrule and fixed including cutting of GI pipe complete all as specified andas directed.
136S & F Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail