Food Corporation Of India-FCI has published Tender For Annual Repair And Maintenance Of Works At Bsc Cherlapally For The Year 2023-24 Sh. Providing Lighting Along Railway Track From G.No.18 And G.No.20 To Railway Entry Gate Ends. Submission Date for this Tender is 29-03-2024. Track Work Tenders in Medchal Malkajgiri Telangana. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required |
2 | 100 mm dia |
3 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
4 | 2 X 10 sq. mm (19mm) |
5 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. |
6 | upto 35 Sq.mm(Clamped with 1 mm thick saddle) |
7 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
8 | Upto 35 sq. mm |
9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
10 | Upto 35 sq. mm |
11 | Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. |
12 | Supplying of XLPE insulated and PVC sheathed cable of 1.1KV grade(as per IS 7098) Aluminium armoured underground cable confirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work. |
13 | 3 x 6.0 sqmm ug cable armoured |
14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
15 | 8 way , Double door |
16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
17 | Single pole |
18 | Single pole and Neutral |
19 | Erection of RCC/ PCC pole of following length in brick ballast and ramming thefoundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. |
20 | Above 6.5 metre and upto 8.0 metre |
21 | Supply of RCC/ PCC pole of 8 Mtr length at the site of Work as required. |
22 | Supply of 200 watt LED Flood light luminaries of Area lighting with energy saving Main Housing, Powder coatedpressure dia cast aluminium housing, Front Clear toughened glass, Suitable secondary lens for better light distribution Gear : Electronic constant current driver of min. 85 % effeciency Internal wiring : Teflon insulated Cu Conductor. LUMOS - 200, OperatingVoltage : 140 V - 270 V, Rated Voltage & Frequency : 240 V, 50 Hz, AC with IP 66 protection as reqd. |
23 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
24 | Group C |
25 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Feeder Pillar installed in Open Area with protection of Rain suitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade of size 900mm(W)X1100mm(H)X350mm (D) along with suitable M.S Angle Base Frame of 45mm X 45mm, interconnections control wiring as required & design approved by Engineer in-charge and comprising of the following : Main Incomer for Power: 4 pole MCCB, 125A, 25KA- 1 No with 200A Rating Aluminium bus bar for 3 phases and neutral Outgoing: 63A, TPNMCB, 10KA - 6 Nos Metering Panneling: Digital Ampere Meter with CTs with Selector Switch, Digital Voltmeter with Selector Switch, HRC Fuses, RYB Indication LED Lamps |
26 | Supplying, installation, testing and commissioning of 1200 mm 20W LED T8 tubelight with PC body (single side connection) with efficacy of 100 lumens/W along with Industrial batten suitable for single T8 LED tube and fixing on wall/truss by using necessary clamps at site of work etc., as required. (as per ISO/IEC Specification) |
27 | CREDIT ITEMS |
28 | Dismantled metal scrap such as GI Boxes etc., |
29 | Dismantled copper insulated wire |