}

Tender For Proper Arrangement Of Cables And Wires Of Indira Bhawan Basement Upper Basement Ground Floor Market Commercial Area With Strengthening And Ducting Of Cable Wires, prayagraj-Uttar Pradesh

Allahabad Development Authority-ADA has published Tender For Proper Arrangement Of Cables And Wires Of Indira Bhawan Basement Upper Basement Ground Floor Market Commercial Area With Strengthening And Ducting Of Cable Wires. Submission Date for this Tender is 15-04-2024. Couplers Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43001126
Tender For Proper Arrangement Of Cables And Wires Of Indira Bhawan Basement Upper Basement Ground Floor Market Commercial Area With Strengthening And Ducting Of Cable Wires
Open Tender
Indian
Uttar Pradesh
prayagraj
15-04-2024

Tender Details

Tender For Proper Arrangement Of Cables And Wires Of Indira Bhawan Basement Upper Basement Ground Floor Market Commercial Area With Strengthening And Ducting Of Cable Wires- 1 Based Rates Uppwd Sor 18 ( Electrical ) / Sor 22 ( Civil ) S / L Of 1100 V Xlpe Insulated Armoured Served Sheathed 400 Sqmm 3.5 Core Lt Cable At A Depth Of 750 Mm Below Ground Level Over A Cusion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And Top, On Surface Shall Be Fixed With Clamps Completeas Direction Of E / I. Sor18 / 501 2 S / L Of 1100 V Xlpe Insulated Armoured Served Sheathed 240 Sqmm 3.5 Core Lt Cable At A Depth Of 750 Mm Below Ground Level Over A Cusion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And Top, On Surface Shall Be Fixed With Clamps Completeas Direction Of E / I. Sor18 / 501 3 S / L Of 1100 V Xlpe Insulated Armoured Served Sheathed 35 Sqmm 3.5 Core Lt Cable At A Depth Of 750 Mm Below Ground Level Over A Cusion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And Top, On Surface Shall Be Fixed With Clamps Completeas Direction Of E / I. Sor18 / 501 4 S / L Of 1100 V Xlpe Insulated Armoured Served Sheathed 16 Sqmm 4 Core Lt Cable At A Depth Of 750 Mm Below Ground Level Over A Cusion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And Top, On Surface Shall Be Fixed With Clamps Completeas Direction Of E / I. Sor18 / 501 5 S / L Of 1100 V Xlpe Insulated Armoured Served Sheathed 10 Sqmm 4 Core Lt Cable At A Depth Of 750 Mm Below Ground Level Over A Cusion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And Top, On Surface Shall Be Fixed With Clamps Completeas Direction Of E / I. Sor18 / 501 6 S / L Of 1100 V Xlpe Insulated Armoured Served Sheathed 10 Sqmm 2 Core Lt Cable At A Depth Of 750 Mm Below Ground Level Over A Cusion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And Top, On Surface Shall Be Fixed With Clamps Completeas Direction Of E / I. Sor18 / 501 7 S / Burying Of 40 Mm Dia 4.5 Mtr Long Gi Pipe Vertically For Earthings Having 12 Mm Dia Holes Spaced 75 Mm Apart Drilled Upto 2 Mtr From The Bottom Complete With Alternate Layer Of Charcoal And Salt As Of E / I. Rate Sor-18 / S.N. 701 8 S / F Of Cable Lugs For 400 Sqmm 3.5 Core Lt Cable Completeas Direction Of E / I. Sor18 / 504 9 S / F Of Cable Lugs For 240 Sqmm 3.5 Core Lt Cable Completeas Direction Of E / I. Sor18 / 504 10 S / F Of Cable Lugs For 35 Sqmm 3.5 Core Lt Cable Completeas Direction Of E / I. Sor18 / 504 11 S / F Of Cable Lugs For 16 Sqmm 3.5 Core Lt Cable Completeas Direction Of E / I. Sor18 / 504 12 S / F Of Cable Lugs For 10 Sqmm 3.5 Core Lt Cable Completeas Direction Of E / I. Sor18 / 504 13 Deductin Item No 501 ( I To T ) , And 506 When Cables Is Passed Through Gi / Ms / Hume Pipe / Duct, The Cost Of Pipe Is To Be Extra When And Where Required.Sor18 / 507 14 Removalof Old Cables / Wires With Cartage Loading Unloading With Making Proper Coiling & Deposite To Store As Direction Of Pda / Uppcl Complete. Based Sor 501 ( 185 / 2 ) 15 Removal & Relaying Of 150-400 Sqmm Old Cableswith Proper Dressing Clamping & Making Connectionscomplete Rate Based Sor 501 ( 215+107 ) 16 Removal & Refixing Of 1 To 3 Phase Kwh Multifunctional Electronic Energy 10-60 Amp Capacity Meterfixed In Integral Box Complete.Rate Based Sor 1209 ( 134 / 2 ) 17 S / L Of 32X6mm Gi Strip With 150 Mm Long Gi Bolts And Nuts Complete In All Respect.Sor 18 / 719 18 S / Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt . Rate Sor-18 / 701 19 Rcc Work With Cement Approved Coarse Sand And 2 Cm Gauge Approved Stone Grit In The Proportion 1:1.5:3 In Slab And Rcc Wallincluding All Material, Labour T&P Etc Complete Rate Sor-22 / S.N. 284 20 12 Mm Thick Cement Plaster In 1:4 Cement And Fine Sand Mortar In Single Coat On Fair Side Of Single Or Half Brick Wall For Interior Plastreing Including All Material, Labour T&P Etc Complete Rate Sor-22 / S.N. 597 ( C ) 21 Ms Or Iron Work For Ms Grill For Railing Including Supplyincluding All Material, Labour T&P Etc Sor-22 / S.N. 502A 22 Based Rates Dsr 2022 Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts& Nuts, Etc. As Required. 225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness As Dsr 22 / 4.6.3 23 450 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness As Dsr 22 / 4.6.10 24 600 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness As Dsr 22 / 4.6.11 25 900 Mm Width X 75 Mm Depth X 2.0 Mm Thickness As Dsr 22 / 4.6.16 26 Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts& Nuts, Etc. As Required. 225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness As Dsr 22 / 4.7.3 27 450 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness As Dsr 22 / 4.7.10 28 600 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness As Dsr 22 / 4.7.11 29 900 Mm Width X 75 Mm Depth X 2.0 Mm Thickness As Dsr 22 / 4.7.16 30 Based Rates Psr In Pda Prayagraj S / L Of 90 Mmdwc Hdpe Pipe 6 Kg Isi Marked Alongwith All Accessories Like Socket, Bend Couplers Etc. Conforming To Is 14930, Part Ii With Fitting And Cutting. Jointing, Clamping, Fastners Nuts & Bolts As Required Etc, Rate Psr In Pda 31 Removal And Refixing Of Service Connections Complete As Required Etc, Rate Psr In Pda 32 Based Rates Market ( Mr ) Supply Of Factory Fabricatedmetal Clad Dust And Vermin Proofmade Of 1.6 / 2 Mm Crca Sheatpanel Tpn Switch Board Complete With 1000 Amp. Air Circuit Breaker With Fuses And Instrument Chamber, The Chambershall Comprise Of Flush Type Ammeter, Voltmeter, Ass, Vss, Ct Etc With Suitable Capacity Electrolytic Al 1200 Amp Busbars As Per Is 8623 Insulated With Heat Shrink Sleeving And Mounting Cmc / Dmc Support With Detachable Side Cover And Suitable End Boxes For Cable, Sockets, Glands And Indicating Lamps. Incoming 1000 Amp Acb-1 Nos And Outgoing 72 Nos. Single Phase Space Meter Including Incoming 800 Amp Acb-1 Nos And Outgoing 3 Phase 8 Nos. Space Meter Including 100 Amp Tp Isolator Attecheble At Site As Per Requirement With Packing, Loading, Unloading, Assembling And Errection Including Grouting Testing & Commisioning, Insurance, Contractor Profit With Labour T&P Complete 33 Supply Of Factory Fabricatedmetal Clad Dust And Vermin Proofmade Of 1.6 / 2 Mm Crca Sheatpanel Tpn Switch Board Complete With 630 Amp. Air Circuit Breaker With Fuses And Instrument Chamber, The Chambershall Comprise Of Flush Type Ammeter, Voltmeter, Ass, Vss, Ct Etc With Suitable Capacity Electrolytic Al 800 Amp Busbars As Per Is 8623 Insulated With Heat Shrink Sleeving And Mounting Cmc / Dmc Support With Detachable Side Cover And Suitable End Boxes For Cable, Sockets, Glands And Indicating Lamps. Incoming 630 Amp Acb-1 Nos And Outgoing 60 Nos. Single Phase Space Meter Including 32 Amp Dp Isolator Attecheble At Site As Per Requirement Complete With Packing, Loading, Unloading, Assembling And Errection Including Grouting Testing & Commisioning, Insurance, Contractor Profit With Labour T&P Complete

Key Value

Document Fees
INR 4720 /-
EMD
INR 287000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail